AKF 597/IX PRODUCT DESCRIPTION SHEET
GB
5019 519 66002
Operation of burners with safety
device and electric ignition
To light one o the burners:
Press the relative knob and turn it anti-
clockwise to the large flame and star
setting .
At the same time, hold the knob down until
the burner ignites.
After the burner has ignited, keep the knob
pressed for about 10 seconds.
Release the knob.
If the burner does not ignite, repeat the operation.
Note:
Should particular local conditions of the
delivered gas make ignition of the burner
difficult, it is advisable to repeat the
operation with the knob turned to the small
flame setting .
The burner safety device shuts off the gas
supply to the burner if the flame goes out
accidentally (because of a sudden draught,
an interruption in the gas delivery, boiling
over of liquids, etc.).
The separator panel, positioned beneath the
cooktop at a minimum distance of 20 mm,
must be sealed.
1.
Removable grids
2-5.
Medium burners
3.
Large burner
4.
Auxiliary burner
6.
Triple crown burner
7.
Front left burner control knob
8.
Rear left burner control knob
9.
Central burner control knob
10.
Rear right burner control knob
11.
Front right burner control knob
Symbols
Shaded
circle
Tap closed
Large flame
and star
Maximum opening/delivery
and electric ignition
Small flame
Minimum opening or
reduced delivery
Insert a wooden panel at least
20 mm thick under the hob, at
a distance of at least 15 mm
from the cooking hob bottom.
5en66002.fm Page 1 Friday, October 24, 2003 3:17 PM
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTES: If the distance A between the wall cabinets is between 600 mm and 680 mm, the
height B must be at least 520 mm.
If the distance A between the wall cabinets is greater than the width of the hob,
the height B must be a minimum of 400 mm.
Before installing a hood above the hob please refer to the hood instructions, which
specify the correct distance.
INJECTORS TABLE CATEGORY II2H3+
Type of gas used Type of
burner
Injector
marking
100/mm
Rated heat
capacity
kW
Rated
consumption
Reduced
heat
capacity
kW
Gas pressure mbar
min. rat. max.
NATURAL GAS
(Methane) G20
triple crown
rapid
semi-rapid
auxiliary
135
130
105
83
3.50
3.00
1.75
1.00
333 l/h
286 l/h
167 l/h
95 l/h
1.50
0.80
0.50
0.50
17 20 25
LIQUID PETROLEUM
GAS
(Cylinder) G30
triple crown
rapid
semi-rapid
auxiliary
92
85
65
50
3.50
3.00
1.75
1.00
254 g/h
218 g/h
127 g/h
73 g/h
1.50
0.80
0.50
0.50
20 28-30 35
LIQUID PETROLEUM
GAS
(Cylinder) G31
triple crown
rapid
semi-rapid
auxiliary
92
85
65
50
3.50
3.00
1.75
1.00
254 g/h
218 g/h
127 g/h
73 g/h
1.50
0.80
0.50
0.50
25 37 45
Type of gas
used
Appliance model Total rated heat
capacity
kW
Total rated
consumption
Air required for
burning m
3
/h
G20 20 mbar 5 gas 11 1048 22
G30 28-30 mbar 5 gas 11 799 22
G31 37 mbar 5 gas 11 799 22