  • Hello! I've reviewed the Glass Backboard Installation Notice, which covers the installation of models 204, 205A, 206, and 208. This document highlights the importance of coplanar attachment points and using shims if needed to prevent glass breakage. I'm here to answer your questions about the installation process and other related details.
  • What should I do if the attachment points are not coplanar?
    What can happen if attachment points are not correctly aligned?
    What does coplanar mean in the installation context?
A
BACKBOARD
>1/16" GAP
DETAIL A
POSITION SHIMS BETWEEN
BACKBOARD MOUNTING
PLATE/S AND THE MOUNTING
PLATE/S OF THE STRUCTURE
DURING INSTALLATION
BACKBOARD
Whenever installing a glass backboard to a new or
existing structure with three or four attachment
points, attachment locations must always be
coplanar. If any attachment point is more than 1/16"
out of plumb from the other attachment points it is
recommended to make adjustments to the structure
before proceding with installing the backboard. If
adjustments can't be made to the structure, shim the
attachment point/s with washers provided to ensure
all attachment points are coplanar. Failure to correct
the attachment points can lead to strain on the
backboard resulting in breakage of the glass bank.