Emerson Epsilon EiDeviceNet Drive User manual

Category
Networking
Type
User manual

This manual is also suitable for

Reference Manual
P/N 400501-08
Revision A2
Date: March 20,2002
© 2001, 2002 Control Techniques Drives, Inc.
Epsilon Ei DeviceNet Drive
Information furnished by Control Techniques Drives Inc. (Control Techniques) is believed to be
accurate and reliable. However, no responsibility is assumed by Control Techniques for its use.
Control Techniques reserves the right to change the design or operation of the equipment described
herein and any associated motion products without notice. Control Techniques also assumes no
responsibility for any errors that may appear in this document. Information in this document is subject
to change without notice.
P/N 400501-08
Revision A2
Date: March 20, 2002
© 2001, 2002 Control Techniques Drives, Inc.
Epsilon Ei
DeviceNet Drive
Reference Manual
ii
© 2001, 2002 Control Techniques Drives, Inc.
Part Number: 400501-08
Revision A2
Date: March 2002
Printed in United States of America
Information in this document is subject to change without notice. No part of this document may be
reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose,
without the express written permission of Control Techniques.
The following are trademarks of Control Techniques and may not be reproduced in any fashion
without written approval of Control Techniques: EMERSON Motion Control, EMERSON Motion
Control PowerTools, AXIMA, “Motion Made Easy.”
Control Techniques is a division of EMERSON Co.
Control Techniques Drives, Inc. is not affiliated with Microsoft Corporation, owner of the Microsoft,
Windows, and Windows NT trademarks.
This product contains DeviceNet software that is licensed from SST, a Division of Woodhead Limited,
50 Northland Road, Waterloo, Ontario - Canada - N2V 1N3.
DeviceNet is a trademark of Open DeviceNet Vendor Association.
RS Networx and SLC 500 PLC are trademarks of Allen Bradley. Control Techniques Drives, Inc. is
not affiliated with Allen Bradley.
This document has been prepared to conform to the current released version of the product. Because
of our extensive development efforts and our desire to further improve and enhance the product,
inconsistencies may exist between the product and documentation in some instances. Call your
customer support representative if you encounter an inconsistency.
iii
Customer Support
Control Techniques
12005 Technology Drive
Eden Prairie, Minnesota 55344-3620
U.S.A.
Telephone: (952) 995-8000 or (800) 397-3786
It is Control Techniques’ goal to ensure your greatest possible satisfaction with the operation
of our products. We are dedicated to providing fast, friendly, and accurate assistance. That is
why we offer you so many ways to get the support you need. Whether it’s by phone, fax or
modem, you can access Control Techniques support information 24 hours a day, seven days
a week. Our wide range of services include:
FAX (952) 995-8099
You can FAX questions and comments to Control Techniques. Just send a FAX to the number
listed above.
Website and Email www.emersonct.com
Website: www.emersonct.com
If you have Internet capabilities, you also have access to technical support using our website.
The website includes technical notes, frequently asked questions, release notes and other
technical documentation. This direct technical support connection lets you request assistance
and exchange software files electronically.
Technical Support (952) 995-8033 or (800) 397-3786
Email: service@emersonct.com
Control Techniques’ “Motion Made Easy” products are backed by a team of professionals
who will service your installation. Our technical support center in Eden Prairie, Minnesota is
ready to help you solve those occasional problems over the telephone. Our technical support
center is available 24 hours a day for emergency service to help speed any problem solving.
Also, all hardware replacement parts, if needed, are available through our customer service
organization.
When you call, please be at your computer, with your documentation easily available, and be
prepared to provide the following information:
Product version number, found by choosing About from the Help menu
The type of controller or product you are using
iv
Exact wording of any messages that appear on your screen
What you were doing when the problem occurred
How you tried to solve the problem
Need on-site help? Control Techniques provides service, in most cases, the next day. Just call
Control Techniques’ technical support center when on-site service or maintenance is
required.
Training Services (952) 995-8000 or (800) 397-3786
Control Techniques maintains a highly trained staff of instructors to familiarize customers
with Control Techniques’ “Motion Made Easy” products and their applications. A number of
courses are offered, many of which can be taught in your plant upon request.
Application Engineering (952) 995-8000 or (800) 397-3786
Email: applengr@emersonct.com
An experienced staff of factory application engineers provides complete customer support for
tough or complex applications. Our engineers offer you a broad base of experience and
knowledge of electronic motion control applications.
Customer Service (Sales) (952) 995-8000 or (800) 397-3786
Email: customer.service@emersonct.com
Authorized Control Techniques distributors may place orders directly with our Customer
Service department. Contact the Customer Service department at this number for the
distributor nearest you.
Document Conventions
Manual conventions have been established to help you learn to use this manual quickly and
easily. As much as possible, these conventions correspond to those found in other Microsoft®
Windows® compatible software documentation.
Menu names and options are printed in bold type: the File menu.
Dialog box names begin with uppercase letters: the Axis Limits dialog box.
Dialog box field names are in quotes: “Field Name.”
Button names are in italic: OK button.
Source code is printed in Courier font: Case ERMS.
v
In addition, you will find the following typographic conventions throughout this manual.
Note
For the purpose of this manual and product, “Note” indicates essential information about
the product or the respective part of the manual.
Throughout this manual, the word “drive” refers to an Epsilon drive.
“Warning” indicates a potentially hazardous situation that, if not avoided, could result in
death or serious injury.
“Caution” indicates a potentially hazardous situation that, if not avoided, may result in
minor or moderate injury.
“Caution” used without the safety alert symbol indicates a potentially hazardous situation
that, if not avoided, may result in property damage.
This Represents
bold
Characters that you must type exactly as they appear. For example, if you are directed to type
a:setup, you should type all the bold characters exactly as they are printed.
italic
Placeholders for information you must provide. For example, if you are directed to type
filename, you should type the actual name for a file instead of the word shown in italic type.
ALL CAPITALS Directory names, file names, key names, and acronyms.
SMALL CAPS Non-printable ASCII control characters.
KEY1+KEY2
example: (Alt+F)
A plus sign (+) between key names means to press and hold down the first key while you press
the second key.
KEY1,KEY2
example: (Alt,F)
A comma (,) between key names means to press and release the keys one after the other.
vi
Safety Instructions
General Warning
Failure to follow safe installation guidelines can cause death or serious injury. The voltages
used in the product can cause severe electric shock and/or burns and could be lethal. Extreme
care is necessary at all times when working with or adjacent to the product. The installation
must comply with all relevant safety legislation in the country of use.
Qualified Person
For the purpose of this manual and product, a “qualified person” is one who is familiar with
the installation, construction and operation of the equipment and the hazards involved. In
addition, this individual has the following qualifications:
Is trained and authorized to energize, de-energize, clear and ground and tag circuits and
equipment in accordance with established safety practices.
Is trained in the proper care and use of protective equipment in accordance with
established safety practices.
Is trained in rendering first aid.
Reference Materials
The following related reference and installation manuals may be useful with your particular
system.
Epsilon Ei Drive Installation Manual (P/N 400501-06)
Epsilon Ei and FM-2 Module Indexing Reference Manual (P/N 400507-01)
FM-3 & FM-4 DeviceNet Module Reference Manual (P/N 400508-03)
Epsilon and E Series Drive Parameters Reference Manual (P/N 400504-01)
ODVA Specification Volumes I and II, Release 2.0
vii
Safety Considerations
Safety Precautions
This product is intended for professional incorporation into a complete system. If you install
the product incorrectly, it may present a safety hazard. The product and system may use high
voltages and currents, carry a high level of stored electrical energy, or are used to control
mechanical equipment that can cause injury.
You should give close attention to the electrical installation and system design to avoid
hazards either in normal operation or in the event of equipment malfunction. System design,
installation, commissioning and maintenance must be carried out by personnel who have the
necessary training and experience. Read and follow this safety information and instruction
manual carefully.
Enclosure
This product is intended to be mounted in an enclosure that prevents access except by trained
and authorized personnel and prevents the ingress of contamination. This product is designed
for use in an environment classified as pollution degree 2 in accordance with IEC664-1. This
means that only dry, non-conducting contamination is acceptable.
Setup, Commissioning and Maintenance
It is essential that you give careful consideration to changes to drive settings. Depending on
the application, a change could have an impact on safety. You must take appropriate
precautions against inadvertent changes or tampering. Restoring default parameters in certain
applications may cause unpredictable or hazardous operation.
viii
Safety of Machinery
Within the European Union all machinery in which this product is used must comply with
Directive 89/392/EEC, Safety of Machinery.
The product has been designed and tested to a high standard. However the level of integrity
offered by the product’s control function – for example stop/start, forward/reverse and
maximum speed – is not sufficient for use in safety-critical applications without additional
independent channels of protection. All applications where malfunction could cause injury or
loss of life must be subject to a risk assessment, and further protection must be provided
where needed.
General warning
Failure to follow safe installation guidelines can cause death or serious injury. The voltages used in
this unit can cause severe electric shock and/or burns, and could be lethal. Extreme care is necessary
at all times when working with or adjacent to this equipment. The installation must comply with all
relevant safety legislation in the country of use.
AC supply isolation device
The AC supply must be removed from the drive using an approved isolation device or disconnect
before any servicing work is performed, other than adjustments to the settings or parameters
specified in the manual. The drive contains capacitors which remain charged to a potentially lethal
voltage after the supply has been removed. Allow at least 6 minutes for the Epsilon 205, 3 minutes
for Epsilon 202/203 and 30 seconds for E Series drives after removing the supply before carrying
out any work which may involve contact with electrical connections to the drive.
Products connected by plug and socket
A special hazard may exist where the drive is incorporated into a product which is connected to the
AC supply by a plug and socket. When unplugged, the pins of the plug may be connected to the
drive input, which is only separated from the charge stored in the bus capacitor by semiconductor
devices. To avoid any possibility of electric shock from the pins, if they are accessible, a means
must be provided for automatically disconnecting the plug from the drive (e.g., a latching
contactor).
Grounding (Earthing, equipotential bonding)
The drive must be grounded by a conductor sufficient to carry all possible fault current in the event
of a fault. The ground connections shown in the manual must be followed.
Fuses
Fuses or over-current protection must be provided at the input in accordance with the instructions
in the manual.
Isolation of control circuits
The installer must ensure that the external control circuits are isolated from human contact by at
least one layer of insulation rated for use at the applied AC supply voltage.
ix
Safety Considerations vii
Introduction 1
Purpose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
DeviceNet Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
DeviceNet Communications Link . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
DeviceNet Messaging and Communications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Master/Slave Relationship . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Installation 5
Mechanical Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
DeviceNet Hardware Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Electrical Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Physical Connections to the DeviceNet Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Configuring the DeviceNet Network 9
Connection Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Software Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
DeviceNet Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Data Processing/Order of Operations for Fixed Assembly Blocks . . . . . . . . . . . . . . . . . . . 17
DeviceNet Online Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Input and Output Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
DN Allocation Choice (Connections Established) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
DN Allocation Master MacID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
DN Baud Rate. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
DN Bus Off Counter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
DN Bus Off Fault Count. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
DN Bus Off Interrupt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
DN Comm Time-out Fault Count. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
DN Device Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
DN Duplicate MacID Fault Count . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
DN FAB Master Receive Block. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
DN FAB Master Send Block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
DN Host Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
DN MacID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
DN Master Receive Bitmap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
DN Master Receive FAB Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Table of Contents
x
DN Master Send Bitmap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
DN Master Send FAB Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
DN Module Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
DN Network Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
DN Receive Counter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
DN Status Major Recoverable Fault . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
DN Status Major Unrecoverable Fault. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
DN Status Minor Recoverable Fault . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
DN Status Minor Unrecoverable Fault . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
DN Transmit Counter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
DN Vendor ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Accessing the EDS File. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Hardware Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Module Status LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Network Status LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Setting the Baud Rate and MacID Externally (One Touch) . . . . . . . . . . . . . . . . . . . . . . . . 32
Network Configuration
Quick Start 35
Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Epsilon Ei DeviceNet Drive Configuration Quick Start Process . . . . . . . . . . . . . . . . . . . . . . . . 35
Polled I/O Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Master Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Explicit Messaging Quick Start 53
Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
How to Send Explicit Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Explicit Messaging Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Drive Parameters 61
By Name . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
By DeviceNet Class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Appendix 71
Glossary 75
Index 79
1
Introduction
Purpose
This manual describes the Epsilon Ei DeviceNet (Ei-DN) Servo Drive and gives examples for
connecting DeviceNet® with Epsilon Indexing drives. The reader should have knowledge of
basic DeviceNet concepts. In addition, the user should be familiar with the functionality of
the Epsilon Ei drive. The Ei-DN drive is capable of all functions of the Epsilon Ei, as
described in the Epsilon Ei Reference Manual (P/N 400507-01). The Quick Start chapters of
this manual offer specific examples of various messaging types as well as a programming
reference that lists functional requirements for the Epsilon Ei-DN drive. For a list of
definitions, consult the“Glossary” on page 75.
Figure 1: Epsilon Ei DeviceNet Drive - Ei-DN-205 Shown
Diagnostic Display
Reset Button
Network Status LED - See page 32
Module Status LED - See page 31
DeviceNet Connections -
See page 6
Epsilon Ei DeviceNet Drive Reference Manual
2
Epsilon Ei DeviceNet Drive Reference Manual
The Epsilon Ei-DN configuration is easily set within PowerTools FM software. In
PowerTools FM software, the user has the option to select between 8 predefined assembly
blocks to be transferred using polled data (8 bytes input, 8 bytes output polled data length per
drive). The Ei-DN additionally allows the master to set up an explicit messaging connection
to access all user accessible parameters within the Epsilon drive through PLC logic.
The Epsilon Ei-DN drive has passed internal tests for conformance as a group 2 DeviceNet
slave.
DeviceNet Overview
DeviceNet is a low-level network that provides connections between simple industrial
devices (sensors, actuators) and higher level devices (industrial PLC’s). DeviceNet standards
and specifications are managed by the Open DeviceNet Vendors Assoc. (ODVA) which is an
independent supplier organization that manages the DeviceNet specification and supports the
worldwide growth of DeviceNet and Ethernet IP.
DeviceNet Communications Link
DeviceNet has two primary purposes:
1. Transport of control-oriented information associated with low-level devices.
2. Transport of other information that is indirectly related to the system being controlled,
such as configuration parameters.
The list below presents a summary of the Physical/Media specific characteristics of
DeviceNet:
1. Trunk-line/drop-line configuration (See Figure 2, “Master/Slave Relationship” on
page 4.)
2. Support for up to 64 nodes
3. Node removal without severing the network
4. Simultaneous support for both network-powered (sensors) and self-powered (actuators)
devices
5. Use of sealed or open-style connectors
6. Protection from wiring errors
7. Selectable data rates of 125k baud, 250k baud, and 500k baud
8. High current capability (up to 16 amps per supply)
3
Introduction
9. Operation with off-the-shelf power supplies
10. Power taps that allow the connection of several power supplies from multiple vendors
that comply with DeviceNet standards
11. Built-in overload protection
12. Power available along the bus: both signal and power lines contained in the trunk line
DeviceNet Messaging and Communications
Master/Slave Relationship
ODVA defines a DeviceNet Master as:
The device that gathers and distributes I/O data for the process controller. A Master contains
a scan list it uses to poll slave devices.
ODVA defines a DeviceNet Slave as:
The slave returns I/O data to its Master when it is polled. With respect to the network, the
Slave is a Group 2 Server or a Group 2 Only Server.
4
Epsilon Ei DeviceNet Drive Reference Manual
Figure 2: Master/Slave Relationship
Trunk Line
Drop Line
Configure PLC
DeviceNet
DeviceNet Master
Scanner Card
Explicit Message Setup
RSLogix
RsLinx
Configure Master
RSNetworx
RsLinx
Slaves (Nodes)
DeviceNet
Configure Ei-DN
24VDC
Power Supply
5
Installation
Mechanical Installation
Follow the instructions for mechanical installation of an Epsilon Ei Drive as outlined in the
Epsilon Ei Installation Manual (P/N 400501-06).
DeviceNet Hardware Components
The following components are necessary to design a DeviceNet cable system:
•Cables
Nodes/Devices
Connectors
Power Supply
Terminating Resistors
Cables
These cables can be obtained from the supplier of the DeviceNet Network Master. (For more
details see the ODVA Specification Volumes I and II, Release 2.0.)
Thick Cable
The thick cable consists of two shielded pairs twisted on a common axis with a drain line in
the center covered with an overall braid. The shield is commonly used as a trunk line when
length is important.
Thin Cable
The thin cable is smaller and more flexible than the thick cable. It is commonly used for drop
lines but can be used for shorter distances as a trunk line.
Nodes/Devices
A DeviceNet slave is any device that is addressable through DeviceNet and contains
DeviceNet communications circuitry. DeviceNet Slaves must comply with the following:
A slave must be connected to the network by a tap and drop-line.
Slaves must be DeviceNet-compatible devices.
63 Slaves can be supported on one network.
Each Slave must be assigned a media access control identification number (MacID).
MacID’s on a single network must be unique.
Epsilon Ei DeviceNet Drive Reference Manual
6
Epsilon Ei DeviceNet Drive Reference Manual
Connectors
DeviceNet connectors can be either open-style (wires exposed) or sealed. These connectors
can be obtained from the supplier of the DeviceNet Network Master. (For more details see
the ODVA Specification Volumes I and II, Release 2.0.)
Power Supply Requirements
A separate 24 VDC power supply is needed for the DeviceNet network. The Ei-DN slave
interface is powered using this “network power.” Devices may take all of their required power
off of the network per ODVA specifications.
The Ei-DN draws 25 mAmps from the DeviceNet power supply.
The power supply must have its own current limit protection.
Fuse protection must be provided for each segment of the cable system.
The power supply must be correctly sized to provide each device with its required power.
Power supplies should be distributed throughout the DeviceNet network to maintain a
maximum of 4 Amps per trunk branch.
For more details, refer to the ODVA Specification Volumes I and II, Release 2.0.
Terminating Resistors
Terminating resistors are used to reduce the reflection of signals over the network. Each
terminator must be 121 ohms and installed on both ends of the network between CAN_L (pin
2) and CAN_H (pin 3).
Electrical Installation
Physical Connections to the DeviceNet Network
A standard five wire configuration is used to connect the Ei-DN to the DeviceNet Network.
A 24 Volt power supply should be connected between V+ and V-.
When multiple Ei-DN devices are present on the network, connection with all devices can be
accomplished by either daisy chaining or by using a multiple tap box.
Pin Number Name Insulation Color
1 V- Black
2 CAN_L Blue
3DrainNone
4 CAN_H White
5V+Red
7
Installation
The connector provided for the DeviceNet connection is keyed: VT (pin 5) and should be
wired to the keyed slot.
Figure 3: DeviceNet Wiring
Terminating
Resistor
8
Epsilon Ei DeviceNet Drive Reference Manual
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96

Emerson Epsilon EiDeviceNet Drive User manual

Category
Networking
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI