Avery Berkel FX220 User Instructions

  • Hello! I am an AI chatbot trained to assist you with the Avery Berkel FX220 User Instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
FX 220
User Instructions
Retail Price Computing Scale
Brisch number 76102-649 Issue 2 07/06/01
ENGLISH *76102-649*
Installation
Make sure that the work surface is firm, steady and free from vibration
and draughts.
To avoid the risk of RSI (Repetitive Strain Injury) it is important to
ensure that the machine is placed on a surface which is ergonomically
satisfactory to the user. In cases where usage is prolonged we
recommend frequent breaks for the user.
Warnings
Cleaning the scale
For your protection, all mains (110V or 230V) equipment used where
damp or wet conditions may occur, must be supplied from a correctly
fused source and protected by an approved RCD to BS7071 or BS7288
or IEC1008-2-2 BS EN 61008:1995. IF IN DOUBT SEEK ADVICE
FROM A QUALIFIED ELECTRICIAN.
To avoid the possibility of electric shock or damage to the machine,
always isolate from the mains power supply before carrying out any
routine maintenance.
Harsh abrasives, solvents, scouring cleaners and alkaline cleaning
solutions, such as washing soda, should not be used especially on the
display windows. Under no circumstances should you attempt to wipe
the inside of the machine.
The outside of the machine may be wiped down with a clean cloth
moistened with water containing a small amount of washing up liquid.
Product variations
Note: Depending on country, some functions may not be available; the
legend on some of the keys may also be different. For example:
Short press Short press
Short press Short press
Or Or
Error messages
If a persistent error message appears, disconnect then
reconnect the scale to the power supply. If the scale remains
inoperative, contact your authorised service agent.
E 5 Disconnect then reconnect the scale to the power supply.
E 10 Battery failure.
E 11 Power supply voltage is too high.
E 15 Contact your authorised service agent.
E 20 Weight error.
E 30 Invalid product configuration.
E35
E 100 Invalid PLU contents (try re-programming the PLU).
E 101 Transaction failed.
E 102 PLU write failed.
E 103 Tare failed.
E 151 Product configuration memory failed.
Error codes:
Contact your authorised service agent.
E 152 User does not have access to this item (in management mode).
E30
Temporary
error
Weight
unsteady
Balance
failed
Under
range
Over
range
Installing the head-up display option
Using a flat-bladed screwdriver, remove the blanking plate from the
back of the scale.
Carefully insert the plug from the display into the socket at the
back of the scale. Replace the blanking plate.
Do not lift the scale by the head-up display or the weighplate.
Attach the display to the scale using the two slotted
screws.
Caution:
Switching on the scale
Connecting to the mains
Warning:
- Plug in the mains cable, replace the
cover and weighplate then switch on using the mains ON/OFF switch.
Do not use the mains adaptor if it is damaged.
NiCad
Using batteries
Caution:
- Plug the battery pack into the scale and place the
pack into the recess. Replace the cover and weighplate.
To avoid damage to the scale caused by leaking batteries,
remove flat or damaged batteries immediately.
When you see the symbol flashing on the display, then you must
either replace the batteries (or recharge the rechargeable batteries).
Using a rechargeable battery pack
Recharging the battery pack
Note:
- Plug the rechargeable
battery pack into the scale and place the pack into the recess. Replace
the cover and weighplate.
- Plug in the mains cable to the
bottom of the scale, then switch on using the mains ON/OFF switch.
You can still use the scale while the battery is being charged.
Bleeps
Short press (Press once) Long press (Press and hold)
Using the Clear key
To clear the last number entered: To clear the entire entry:
Short press Long press
1,572
0,26
0,40
1,572
0,00
0,40
Selecting an alternate price base/Alternative units
00,000
0,00
0,00
Short press
Testing the display/Selecting sleep mode
Short press
1
101d
0-6-0
Short press
X2
Service
information =
Wake up:
Long press Short press
SLEEP
Using the scale
Zeroing the scale - Make sure that the scale is at zero before
weighing any goods.
Short press
00,000
0,00
0,00
Weighing goods - Place the goods onto the scale and enter the unit
price.
Unit price
Short press
1,572
0,26
0,40
Short press
Multiplying a unit price
Unit price
Short press
1,572
0,26
0,40
1,572
0,26
0,80
Short press Short press
Or
Retaining a unit price
To cancel a
unit price:
Unit price
Short press
Repeat until all the goods have been weighed
Short press
Short press
Long press
1,572
0,26
0,40
Item price
Short press
No of items
Short press
Short press
Multiplying non-weighed items
Repeat until all the goods have been weighed
5
0,36
Short press
Long press
Viewing the total Cancelng the total
5
1,80
Short press Short press
Item price
Short press
Unit price
Short press
Repeat until all the goods have been weighed
Using the add key
6
1,36
Short press
Or
Using tares
Semi-automatic tares
Retaining a tare
Cumulative tare
Keyboard entered tare
Proportional tare
For example, 33 = 3.3%, 205 = 20.5%
Short press
Unit price
Short press
1,572
0,26
0,40
Short press
Unit price
Short press
Repeat until all the goods have been weighed
1,572
0,26
0,40
Short press Unit price
Short press
% tare X10
Short press
1,572
0,26
0,40
Short press Unit price
Short press
Tare value
Short press
1,572
0,26
0,40
To cancel
a retained tare:
Short press
Unit price
Short press
1,572
0,26
0,40
Short press
Long press
Repeat until all the goods have been weighed
Short press
Programming a non-weighed PLU hot-key
Assign a unit price to the PLU
You will not be able to programme a PLU hot key if it has already
been changed in management mode.
Note:
Item price
Short press Long press
Programming a weighed goods PLU hot-key
Assign a tare to the PLU (if required)
Assign a unit price to the the PLU (if required) Select the PLU key:
Note: For some countries, the tare value canot be saved.
Short press
Or Or
% of tare
Short press Short press Short press
Tare value
Short press
Unit price
Short press Long press
Note: To programme
PLUs 10 - 20 refer to
management mode.
Short press
Using PLUs
Using the PLU hot keys - For example, PLU .
2
0,000
0,26
0,00
Short press
1,572
0,26
0,40
Short press
Short press Short press
1,572
0,26
0,40
Using PLUs1-9- For example, PLU 7.
Short press Short press
Short press
1,572
0,26
0,40
Using PLUs 10 - 20 - For example, PLU 12.
Navigating management mode
For example, turn the keyboard bleeper off and change the backlight
time to 5 seconds.
Note: Depending on country, some functions may not be available.
Branch Sub-branch
Value
19.00
1Branch ( )
19
For Example:
Branch ( )
20
Sub-branch ( )
00
Sub-branch ( )
01
Sub-branch ( )
00
0.00
0
19.01
1
19.00
1
19.01
0
20.00
4
20.00
0
20.00
1
Short press
Long press
Short pressShort press
Short pressShort press
Short press
Long press
Long press
Management mode
Entering management mode
Short press
Make a note of this
number, cut out and
keep in a safe place.
6231
Short press
Go to the next branch (long press)
Go to next sub-branch (short press)
Go to the previous branch (long press)
Go to previous sub-branch (short press)
CSelect value to be changed (short press)
Return to Branch 00 (Long press)
Increment the value (short press)
Increment the value X10 (long press)
Change the value (short press)
After changing a value, you must
go to the next branch to accept the value.
Note:
CExit management mode
Switching the keyboard bleeper on/off
Go to branch 19, sub-branch 01
0=Off
1=On
19.01
1
Error bleeper
Go to branch 19, sub-branch 03
0=Off
1=On
19.03
1
Target bleep
Branch 19, sub-branch 02 - Not applicable for this machine.
Changing the bleeper volume
Go to branch 19, sub-branch 04
0 = Quiet
1 = Loud
19.04
1
0 = always off
1 = 5 seconds
2 = 1 minute
3 = 5 minutes
4 = always on
20.00
1
Changing the backlight time
Go to branch 20, sub-branch 00
0 = none
1 = 1 minute
2 = 5 minutes
3 = 30 minutes
20.01
1
Changing the sleep time
Go to branch 20, sub-branch 01
0=Off
1=On
19.00
1
Switching the bleeper alarm on/off
Go to branch 19, Sub-branch 00
Changing the duration of a 'Long' press
Go to branch 29, sub-branch 00
29.00
200
Enter a value in units of 10 milliseconds (50 -255).
For example :
200 = 2 seconds
150 = 1½ seconds
100 = 1 second
Changing the default price base
Go to branch 61, sub-branch 00
0 = 100g
1 = kg (lb)
61.00
1
Changing a PLU unit price
Go to branch 100 + PLU number, sub-branch 00
You must now select the PLU price base.Note:
For example, PLU 05 Branch, 100+5=105
Unit price = 2.35
0 = No unit price
105.00
235
Short press
Changing a PLU tare
Go to branch 100 + PLU number, sub-branch 01
Weighed tare: Keyboard entered tare:
For example, PLU 05 Branch, 100+5=105
105.01
50
Short press
Or
Short press Short pressShort press
X2
Changing a PLU price base
Go to branch 100 + PLU number, sub-branch 03
For example, PLU 05 Branch, 100+5=105
4 = 100g
5 = kg (lb)
105.03
5
This document contains a general guide only of the product and shall not form any contract unless specifically agreed
by Avery Berkel in writing in each case on the Order Acknowledgment. The specification of the products described
herein may vary from time to time and may be altered without notice.
Internet: http://www.averyberkel.com
Changing a PLU proportional tare
Go to branch 100 + PLU number, sub-branch 02
For example, PLU 05 Branch, 100+5=105
% tare X10, for example:
33 = 3.3%
205 = 20.5%
105.02
33
/