REV0.1 11012023
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATIONS WITHOUT NOTICE
LLX18-RGBW 24V - Installation Instructions
Please read complete instruction prior to installation and keep for future reference!
Models LLX18-RGBW-, LLX18X2-RGBW- 7777 N. Merrimac Ave
Niles, IL 60714
T 224.333.6033
F 224.757.7557
www.luminii.com
1. Product should be installed by a qualified electrician.
2. Prior to installation ensure power is off at fuse box to prevent electrical shock.
3. Use only with Class 2 power unit. Utiliser seulement avec Classe 2 unite d’alimentation electrique.
4. Suitable for Damp Locations. Convient Aux Emplacements Humides.
5. For under-cabinet or shelf mount.
6. Conforms to UL STD 2108. Certified to CSA STD C22.2 No.250.0.
WIRING DIAGRAM
SR-DMX-SPI
Smart Pixel LineLED Decoder
24V-
24V+
PIXEL LED
In
Out
(-)
(+)
POWER SUPPLY
(N)
(L)
CONTROLLER WIRES
1000 ft max,
decoder to Controller
AC
input
output
24VDC
32 ft max, decoder to strip
Before wiring, ensure power is off to power
supply
Also, ensure that the correct power supply (voltage
and wattage) is used to power the LED strips
connected to the decoder. Follow illustrated wiring
diagram. Use screwdriver to open and close
connection slots.
24V-
24V+
24V-
24V+
NOTE: When connecting two or more LED strip lights or light fixtures, always make sure the signal direction arrows
are pointing to same direction
The signal direction arrow should appear on each section (cut increment) of LED strip
Signal direction arrow Signal direction arrow
NOTE: Must power from the opposite direction of the signal direction arrow
NOTE: Please make sure that
power is turned off before wiring.
Also, ensure that the correct power
supply (voltage and wattage)
is used to power the LED strips
connected to the decoder. Follow
illustrated wiring diagram. Use
screwdriver to open and close
connection slots.