AXI 016 • Setup Guide
This guide provides basic instructions for an experienced technician to install the AXI 016 Audio Expansion Interface. The AXI016
is a pure breakout device that provides 16 line-level outputs for EXP-enabled devices. The AXI016 is simple to use with no DSP
processing hardware controls. For additional information and specications, see the AXI 016 product page at www.extron.com.
NOTES:
EXP-enabled devices are devices that contain an Extron EXP port for routing 16 bidirectional channels of digital audio.
In this guide, “EXP-enabled devices” and “EXP devices” are used interchangeably.
Disconnect Power and Mount the AXI 016
Disconnect power from the AXI 016 and power off all devices that will be connected to it. The AXI 016 is housed in a half-rack
width, 6-inch deep, 1U-high metal enclosure that can be rack mounted, set on a rack shelf, or placed on a table with the provided
rubber feet. Select a suitable mounting location, then choose an appropriate mounting option.
Rear Panel Connections
AXI 016
910
11 12
1
2
3
4
OUTPUTS
EXP INPUT
POWER
12V
0.7 A MAX
13
14
15 16
5
6
7
8
EXP THRU
PRIMARY
DEVICE
SECONDARY
DEVICE
INPUT THRU
EXP
AUDIO EXPANSION INTERFACE
AXI 016
CLIP
SIGNAL
1 2 3 4
5
6 7
8 9 10 11
12
OUTPUTS
13 14 15
16
A B D
C
A B
C
A
Power Inlet
C
EXP Input Port and LED
B
Analog Audio Outputs
D
EXP Thru Port and LED
Figure 1. AXI 016 Rear Panel Connections
A
12 VDC Power Inlet — Connect the 12 VDC power supply to the rear panel captive screw power inlet. Then, plug the power
cable into the IEC inlet on the external power supply (see figure 2 below and the Attention notices on the next page).
Rear Panel
Power Receptacle
DC Power Cord
Captive Screw
Connector
Ground
all devices.
External
Power Supply
12 VDC, 1.5 A max.
– Return
+12 VDC input
Ridged
Smooth
1A MAX
100-240V 50-60Hz
Figure 2. Connecting the External Power Supply
2
ATTENTION:
Always use a power supply provided by or specied by Extron. Use of an unauthorized power supply voids all regulatory
compliance certication and may cause damage to the supply and the end product.
Utilisez toujours une source d’alimentation fournie par Extron. L’utilisation d’une source d’alimentation non autorisée
annule toute conformité réglementaire et peut endommager la source d’alimentation ainsi que l’unité.
Unless otherwise stated, the AC/DC adapters are not suitable for use in air handling spaces or in wall cavities. The
power supply is to be located within the same vicinity as the Extron AV processing equipment in an ordinary location,
Pollution Degree2, secured to the equipment rack within the dedicated closet, podium, or desk.
Sauf mention contraire, les adaptateurs AC/DC ne sont pas appropriés pour une utilisation dans les espaces d’aération
ou dans les cavités murales. La source d’alimentation doit être située à proximité de l’équipement de traitement
audiovisuel dans un endroit ordinaire, avec un degré2 de pollution, fixé à un équipement de rack à l’intérieur d’un
placard, d’une estrade, ou d’un bureau.
The installation must always be in accordance with the applicable provisions of National Electrical Code ANSI/NFPA 70,
article 725 and the Canadian Electrical Code part 1, section 16. The power supply shall not be permanently xed to
building structure or similar structure.
Cette installation doit toujours être en accord avec les mesures qui s’applique au National Electrical Code
ANSI/NFPA70, article725, et au Canadian Electrical Code, partie1, section16. La source d’alimentation ne devra pas
être fixée de façon permanente à une structure de bâtiment ou à une structure similaire.
B
Analog Audio Outputs — Use 6-pole, 3.5 mm captive screw connectors to connect up to 16 balanced or unbalanced
line-level devices. Balanced or unbalanced mono devices can also be connected using 3-pole, 3.5 mm captive screw
connectors.
Tip
Sleeve
Tip
Sleeve
Tip
Slee
ve
Ring
Tip
Slee
ve
Ring
6-pole Audio OUTPUT Wiring
Balanced Output Unbalanced Output
NO Ground Here
NO Ground Here
3-pole Audio OUTPUT Wiring
Unbalanced Output
Tip
Sleeve
NO Ground Here
Balanced Output
Tip
Sleev
e
Ring
Figure 3. Audio Output Wiring
ATTENTION :
For unbalanced audio outputs, connect the sleeves to the ground contact. DO NOT connect the sleeves to the
negative (-) contacts.
Pour l’audio asymétrique, connectez les manchons au contact au sol. NE PAS connecter les manchons aux
contacts négatifs (–).
C
EXP Input Port and LED — This RJ-45 EXP port connects the AXI 016 to the EXP port of a primary EXP device. The
Expansion output channels of the primary EXP device are sent to the AXI016 line outputs (see Connecting a Primary
Device to the EXP Input Port on the next page). The LED to the right of the EXP INPUT port blinks to indicate a primary
EXP device is connected.
NOTE: A primary EXP device is a device that has been set as a Primary Unit in DSP Configurator (see the
DMP 128 Plus User Guide for more information regarding primary and secondary EXP devices). DMP 128 Plus units are
set to primary by default.
D
EXP Thru Port and LED — This RJ-45 EXP port connects the Expansion output channels of a secondary EXP device
to the AXI016. When a primary EXP device is connected to the EXP INPUT port, the Expansion output channels of the
secondary EXP device connected to the EXP THRU port are sent through the AXI016 to the Expansion input channels of the
primary device connected to the EXP INPUT port (see Connecting a Primary EXP Device and Secondary EXP Device on
page4). If no primary EXP device is connected to the EXP INPUT port, the Expansion output channels of the secondary
EXP device connected to the EXP THRU port are sent to the AXI016 line outputs (see Connecting a Secondary EXP Device
to the EXP Thru Port on page5). The LED to the right of the EXP THRU port lights solid to indicate a secondary EXP
device is connected.
NOTE: A secondary EXP device is a device that has been set as a Secondary Unit in DSP Configurator (see the
DMP 128 Plus User Guide for more information regarding primary and secondary EXP devices). DTP CrossPoint units
are set to secondary by default.
3
Front Panel Features
AXI 016
910
11 12
1
2
3
4
OUTPUTS
EXP INPUT
POWER
12V
0.7 A MAX
13
14
15 16
5
6
7
8
EXP THRU
PRIMARY
DEVICE
SECONDARY
DEVICE
INPUT THRU
EXP
AUDIO EXPANSION INTERFACE
AXI 016
CLIP
SIGNAL
1 2 3 4
5
6 7
8 9 10 11
12
OUTPUTS
13 14 15
16
A B D
C
A B
C
Figure 4. AXI 016 Front Panel Features
A
Power Indicator LED — This green LED lights solid when the AXI016 is powered and fully operational.
B
EXP Indicator LEDs — The green Input LED blinks to indicate a primary EXP device is connected to the rear-panel
EXP INPUT port. The green Thru LED lights solid to indicate a secondary EXP device is connected to the rear-panel
EXP THRU port.
C
Output Signal and Clip LEDs — Sixteen pairs of stacked green and red LEDs light steadily when signal is present and
increase in intensity from -60 dBFS (lowest intensity, signal presence indication) to -3 dBFS (full brightness). The red clip
LEDs light solid to indicate clipping when a signal exceeds -3 dBFS. The red clip LEDs stay lit for one second after clipping
ceases.
Application and Signal Flow Diagrams
The following diagrams display the different signal ows when primary and secondary EXP-enabled devices are connected to the
AXI 016.
NOTE: Daisy-chaining two or more AXI 016 units together is not supported.
Connecting a Primary Device to the EXP Input Port
The diagram below displays the AXI 016 signal ow when only a primary EXP device, such as the DMP128Plus, is connected to
the EXP INPUT port of the AXI016.
All 16 Expansion output channels of the primary device are routed to the line outputs of the AXI016 (see path A1 in gure 5).
Expansion output channel 1 of the primary device is routed to the AXI 016 line output 1, and so on.
AXI 016
910
11 12
1
2
3
4
OUTPUTS
EXP INPUT
POWER
12V
0.7 A MAX
13
14
15 16
5
6
7
8
EXP THRU
PRIMARY
DEVICE
SECONDARY
DEVICE
DMP 128 Plus (Primary Device)
AXI 016
LAN
DMP 128 Plus C
RxTx G
RS-232
+S+V -S G
G
4
O1 O2 GIN
5
O1 O2 GIN
6
O1 O2 GIN
7
O1 O2 GIN
8
O1 O2
56
78
11 12
12
3
4
910
4 5 6 7 8
OUTPUTS
DMP EXP
ACP
REMOTE
G
8
O1
2
8
R
x
x
G
RS
-232
A1
A1
NOTE: Dotted lines represent signal flows inside the AXI 016. Solid lines represent signal flows over CAT 6 cable.
Figure 5. Basic Signal Flow from Primary EXP Device to AXI 016
A
Power Indicator LED
B
EXP Indicator LEDs
C
Output Signal and Clip LEDs
4
Connecting a Primary EXP Device and Secondary EXP Device
The diagram below displays the signal ow when a primary EXP-enabled device is connected to the EXP INPUT port and a
secondary EXP-enabled device is connected to the EXP THRU port.
All 16 Expansion output channels of the secondary device are routed through the AXI 016 and into the primary EXP device
Expansion input channels (see path B in the gure below).
All 16 Expansion output channels of the primary EXP device are routed to the 16 analog line outputs of the AXI 016 (see path
A1 in the gure below). Expansion output channel 1 of the primary EXP device is routed to the AXI 016 line output 1, and so
on.
All 16 Expansion output channels of the primary EXP device are also routed to the Expansion input channels of the
secondary EXP device (see path A2 in the gure below). Expansion output channel 1 of the secondary EXP device is routed
to Expansion input channel 1 of the primary EXP device, and so on.
AXI 016
910
11 12
1
2
3
4
OUTPUTS
EXP INPUT
POWER
12V
0.7 A MAX
13
14
15 16
5
6
7
8
EXP THRU
PRIMARY
DEVICE
SECONDARY
DEVICE
DMP 128 Plus (Primary Device)
AXI 016
DTP CrossPoint 108 4K (Secondary Device)
LAN
DMP 128 Plus C
RxTx G
RS-232
+S+V -S G
G
4
O1 O2 GIN
5
O1 O2 GIN
6
O1 O2 GIN
7
O1 O2 GIN
8
O1 O2
56
78
11 12
12
3
4
910
4 5 6 7 8
OUTPUTS
DMP EXP
ACP
REMOTE
G
8
O1
O
2
8
Rx
x
G
RS
-232
50-60 Hz
100-240V ~
--A MAX
1 2 3 4 5A 6A
XTP
Tx Rx
RTS CTS
GTxRxG Tx Rx G
RS-232 IR
Tx Rx Tx RxG
XTP
DTP
EXP
LINK
LAN 2
LAN 1
LAN 3
DTP
HDBT
1234
57
6
P
CROSSPOINT 108 4K
R
OVER TP
SIG LINK
IN
AUDIO INPUTS
CONTROL
1234G
DIGITAL I/OCOM 3COM 2COM 1
S
DMP EXPANSION
SGG
1
1
2
2
C34C
INPUTS
-S G+S+V
PWR OUT = 6W
OUTPUTS
RS-232 IR
Tx Rx Tx RxG
1
LR
3
LR
5
L
2
LR
4
LR
6
L
IR/SERIAL eBUSRELAYS
SIG LINK
OUT
SIG LINK
OUT
5B 6B
RS-232 IR
Tx Rx Tx Rx
XTP
DTP
H
G
RS-232 IR
Tx Rx Tx RxG
OVER TP
1
1
CO O
INPUTS
OUTPUTS
I
NK
R
L
R
L
S
I
G
O
O
U
A1
B
B
A2
B
A1
A2
NOTE: Dotted lines represent signal flows inside the AXI 016. Solid lines represent signal flows over CAT 6 cable.
Figure 6. Advanced Signal Flow when Primary and Secondary EXP Devices are Connected
68-3069-50 Rev. A
10 17
Extron Headquarters
+800.633.9876 Inside USA/Canada Only
Extron USA - West Extron USA - East
+1.714.491.1500 +1.919.850.1000
+1.714.491.1517 FAX +1.919.850.1001 FAX
Extron Europe
+800.3987.6673
Inside Europe Only
+31.33.453.4040
+31.33.453.4050 FAX
Extron Asia
+65.6383.4400
+65.6383.4664 FAX
Extron Japan
+81.3.3511.7655
+81.3.3511.7656 FAX
Extron China
+86.21.3760.1568
+86.21.3760.1566 FAX
Extron Middle East
+971.4.299.1800
+971.4.299.1880 FAX
Extron Australia
+61.8.8113.6800
+61.8.8351.2511 FAX
Extron India
1800.3070.3777
(Inside India Only)
+91.80.3055.3777
+91.80.3055.3737 FAX
© 2017 Extron Electronics All rights reserved. All trademarks mentioned are the property of their respective owners. www.extron.com
Connecting a Secondary EXP Device to the EXP Thru Port
The diagram below displays the signal ow when only a secondary EXP device such as the DTP CrossPoint 108 4K is connected
to the EXP THRU port.
All 16 Expansion output channels of the secondary EXP device are routed to the 16 line outputs of the AXI 016. The
Expansion output channels of a secondary EXP device are only routed to the AXI 016 line outputs when no primary device
is connected to the EXP INPUT port (see Connecting a Primary EXP Device and Secondary EXP Device on the previous
page).
Expansion output channel 1 of the secondary EXP device is routed to the AXI 016 line output 1, and so on.
AXI 016
910
11 12
1
2
3
4
OUTPUTS
EXP INPUT
POWER
12V
0.7 A MAX
13
14
15 16
5
6
7
8
EXP THRU
PRIMARY
DEVICE
SECONDARY
DEVICE
DTP CrossPoint 108 4K (Secondary Device)
50-60 Hz
100-240V
~
--A MAX
1 2 3 4 5A 6A
XTP
Tx Rx
RTS CTS
GTxRxG Tx Rx G
RS-232 IR
Tx Rx Tx RxG
XTP
DTP
EXP
LINK
LAN 2
LAN 1
LAN 3
DTP
HDBT
1234
57
6
P
CROSSPOINT 108 4K
R
OVER TP
SIG LINK
IN
AUDIO INPUTS
CONTROL
1234G
DIGITAL I/OCOM 3COM 2COM 1
S
DMP EXPANSION
SGG
1
1
2
2
C34C
INPUTS
-S G+S+V
PWR OUT = 6W
OUTPUTS
RS-232 IR
Tx Rx Tx RxG
1
LR
3
LR
5
L
2
LR
4
LR
6
L
IR/SERIAL eBUSRELAYS
SIG LINK
OUT
SIG LINK
OUT
5B 6B
RS-232 IR
Tx Rx Tx Rx
XTP
DTP
H
G
RS-232 IR
Tx Rx Tx RxG
OVER TP
1
1
CO
O
INPUTS
OUTPUTS
I
NK
R
L
R L
S
I
G
O
O
U
B
B
AXI 016
NOTE: Dotted lines represent signal flows inside the AXI 016. Solid lines represent signal flows over CAT 6 cable.
Figure 7. Basic Signal Flow from Secondary EXP Device to AXI 016
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

Extron AXI 016 User manual

Category
Musical Equipment
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI