Siemens SLT-1-UK Upgrade Kit User manual

Type
User manual
P/N 315-099053-2
Installation Instructions
Model SLT-1-UK
SLT-1 Upgrade Kit
Fire Safety
Siemens Building Technologies, Inc.
8 Fernwood Road
Florham Park, New Jersey 07932
Siemens Building Technologies, Ltd.
2 Kenview Boulevard
Brampton, Ontario L6T 5E4 CN
Use the SIEMENS Model SLT-1-UK kit to up-
grade the SLT-1 firmware to the latest released
firmware.
INSTALLATION GUIDELINES
Carefully follow the installation instructions below
to upgrade the SLT-1 firmware.
CAUTION
Electronic equipment is extremely vulnerable
to static discharge. Extreme care should be
taken when performing this upgrade.
1. Notify the person in charge of the fire alarm
system (and the Fire Department if they are
connected to the SXL-EX) that the control
panel will be temporarily out of service while
the firmware upgrade is installed.
2. Power down the system, battery first, then
the AC.
3. Remove U4, SLT-1 firmware. Do this by
lifting one end of the IC slightly, then the
other end. Continue this process until the IC
comes free. Use a short, thin blade
screwdriver for best results.
4. Remove the new SLT-1 IC from its packaging
materials and check to see that all of the pins
are straight. Straighten any that are not.
5. Place the new SLT-1 IC in the socket for U4.
Locate the notch in the end of the IC to the
left as indicated by the silkscreen outline on
the PC board. Be sure that all of the pins go
into the proper socket holes. Press down
firmly to seat the IC properly.
6. Power up the system, AC first, then battery.