NeuroNexus SmartBox Pro Radiens Allego User guide

Type
User guide

NeuroNexus SmartBox Pro Radiens Allego is a cutting-edge data acquisition and experimental management system designed for neuroscience research. It provides high-quality acquisition and recording of up to 512 channels of neural and biological signals, enabling comprehensive electrophysiological studies. With its plug-and-play compatibility with NeuroNexus probes and electrode arrays, this system simplifies experimental setup and streamlines data collection.

NeuroNexus SmartBox Pro Radiens Allego is a cutting-edge data acquisition and experimental management system designed for neuroscience research. It provides high-quality acquisition and recording of up to 512 channels of neural and biological signals, enabling comprehensive electrophysiological studies. With its plug-and-play compatibility with NeuroNexus probes and electrode arrays, this system simplifies experimental setup and streamlines data collection.

SmartBox Pro
Radiens Allego
V 2.6.2
April 9, 2021
TableofContents
TableofContents 2
Introduction 3
Gettingupandrunning 4
What'sintheBox 4
ComputerRequirements 4
SystemOverview 5
FrontPanel 5
BackPanel 5
ConnecttheSmartBoxProtoYourComputer 6
DownloadandInstalltheAllegoSoftwareApplication 7
Windows 7
macOS 7
AllegoInterface 8
AllegoDashboard 8
ActivatingAllego 9
CheckingHardwareConnection 11
TrainingwithAllego 12
Quickstreamingandsaving-Determineifaheadstageandprobeareconnectedprop-
erlyandcanstreamdata 13
SmartBox Pro
DATA ACQUISITION AND EXPERIMENTAL MANAGEMENT
NeuroNexus Technologies, Inc. ©2020 | 5200 S. State Street, Suite 200, Ann Arbor, Michigan, 48108, USA
Telephone: +1.734.913.8858 | Fax: +1.734.786.0069 | [email protected]
Page
2
Introduction
CongratulationsonyourpurchaseoftheSmartBoxPro/RadiensAllegoacquisitionsystem!This
advanced  new  system  from  NeuroNexus  enables  and  accelerates  neuroscience  research
throughitsuniquecombinationofperformance,easeofuse,andforward-lookingadvancedfea-
tures,whichinclude:
lPlug-and-playcompatibilitywithallNeuroNexusprobesandelectrodearrays
lHigh-qualityacquisitionandrecordingofupto512channelsofneuralandbio-
logicalsignals
lUnique,  highly  interactive,  probe- centric  user  interface  that  allows  the
researchertoremainfocusedontheexperimentathand
This“QuickStartGuide”isintendedtoprovideabriefoverviewoftheSmartBoxPro/Allegosys-
temandsomeofitsbasicfunctions.
Anoteonbasicterminology:“SmartBoxProreferstothehardwarecomponentofthesystem,
i.e.,the“SmartBoxProbox.”“RadiensAllegoreferstothesoftwareapplicationthatinterfaces
withandcontrolsthehardwarebox.
IMPORTANT:Pleasecheckthe NeuroNexus websiteat www.NeuroNexus.com for regular
updatesofthisdocumentandrelatedsystemdocumentation.
ForquestionsregardingoperationofthesystemorifyouhaveanyissueswiththeSmartBox
Pro,pleaseemailusat[email protected].Youcanalsocallusat+1.734.913.8858.
SmartBox Pro
DATA ACQUISITION AND EXPERIMENTAL MANAGEMENT
NeuroNexus Technologies, Inc. ©2020 | 5200 S. State Street, Suite 200, Ann Arbor, Michigan, 48108, USA
Telephone: +1.734.913.8858 | Fax: +1.734.786.0069 | [email protected]
Page
3
Gettingupandrunning
What'sintheBox
lSmartBoxProunit
lACPowerAdapter
lUSB3.0cable
l(2)Banana-to-bananacables
l(2)BNC-to-BNCcables
l(2)BNC-to-Alligatorcables
lSelectedSmartLinkheadstageamplifier(s)andheadstageinterfacecable(s)
thatarespecifiedintheorder.FormoreinformationaboutourSmartLinkhead-
stagespleasevisitourwebsiteatwww.NeuroNexus.com
l(optional)Windowslaptopcomputerthatwasspecifiedintheorder
ComputerRequirements
Thecomputersystemrequirementsinclude:
lStorage:SSD.Traditionalmagneticharddisksmaynotbefastenoughinsome
recordingconfigurations
lUSB3.0
l3rdGenerationIntelCorei7processors(4cores),orequivalent
SmartBox Pro
DATA ACQUISITION AND EXPERIMENTAL MANAGEMENT
NeuroNexus Technologies, Inc. ©2020 | 5200 S. State Street, Suite 200, Ann Arbor, Michigan, 48108, USA
Telephone: +1.734.913.8858 | Fax: +1.734.786.0069 | [email protected]
Page
4
SystemOverview
FrontPanel
PowerLED/Button Indicatessystemstatus.
ABCD HeadstageInputPorts ProprietaryHDMI-styleportsforconnectingSmartLinkhead-
stagestoPortsA-D.
RE ReferenceElectrode BananajackforconnectiontoReferenceElectrode(poten-
tiostat/galvanostat).
CE CounterElectrode BananajackforconnectiontoCounterElectrode(poten-
tiostat/galvanostat).
V/I Potentiostat/GalvanostatPort
ProprietaryHDMI-stylemultifunctionportforconnectiontothe
SmartBoxProMUXadaptertoprovideaccesstopotentiostat
andgalvanostatfunctions.
BackPanel
DI/DO Digital/AnalogInputsand
Outputs BNCconnectorsforconnectingauxiliarysignalsfromotherinstruments.
SystemGround Bananajackforconnectingtheboxtoalow-noiseearthgroundpoint.
USB
3.0 USB3.0Connector ConnecttoaUSB3.0portonPC/MacusingthesuppliedUSB3.0cable.
9VDC DCPowerInput UseonlythesuppliedACpoweradaptertoprovidetherequiredDCvoltage
input.
AudioOutput StereoaudioAuxjackforconnectiontospeakerstomonitortheAnalogOut-
put(AO)channels.
SmartBox Pro
DATA ACQUISITION AND EXPERIMENTAL MANAGEMENT
NeuroNexus Technologies, Inc. ©2020 | 5200 S. State Street, Suite 200, Ann Arbor, Michigan, 48108, USA
Telephone: +1.734.913.8858 | Fax: +1.734.786.0069 | [email protected]
Page
5
ConnecttheSmartBoxProtoYourComputer
lUnpacktheSmartBoxProunitfromitspackagingandplaceitonasecuresurfacewith
adequateventilation
lPlugtheACadapterintoastandard(110-220V)walloutletandconnectitsDCpowerout-
putpinintotothepowerportoftheunit
lConnecttheUSBcabletotheSmartBoxProandaUSB3.0portonyourcomputer
lWiththecomputeronandconnectedtotheinternet,pressandreleasetheSmartBoxPro
powerLEDswitch.Yourcomputershouldindicatethatithasdetectednewhardware(Opal
KellyXEM6310-LX45).Thenecessarydriversshouldbeautomaticallyinstalledwithnofur-
theractionnecessary.IfthedriverdoesnotinstallortheAllegorecordingsoftwarecannot
detectyourSmartBoxProunit,trydownloadingandinstallingthedriverfromwww.Neur-
oNexus.com.
lConnectaSmartLinkheadstageamplifiertoaSmartLinkHDMIcableandthenconnect
theotherendtooneoftheSmartBoxProamplifierports(portsA-D)
lOptional-UseabananacabletoattachtheSmartBoxProgroundporttoalow-noiseearth
ground.Thismaybebeneficialforremovingextrinsicnoiseonthesignallinesdepending
onthelaboratoryenvironment.(Note:Regardlessofthegroundportconnections,the
recordingreferenceandgroundsignalsareprovidedthroughtheconfigurationofthe
SmartLinkheadstageamplifier(s))
lNote:DonotconnectthemultiplexeradaptortoportsAthroughD
SmartBox Pro
DATA ACQUISITION AND EXPERIMENTAL MANAGEMENT
NeuroNexus Technologies, Inc. ©2020 | 5200 S. State Street, Suite 200, Ann Arbor, Michigan, 48108, USA
Telephone: +1.734.913.8858 | Fax: +1.734.786.0069 | [email protected]
Page
6
DownloadandInstalltheAllegoSoftwareApplication
AllegoisthesoftwareapplicationforinterfacingwiththeSmartBoxProunit.Thelatestversionof
AllegocanalwaysbefoundontheNeuroNexuswebsite.
https://neuronexus.com/allego-software-downloads-page/
Oncethere,selectthelinkfortheappropriateoperatingsystemandthenselect“Download”to
beginthetransfer.
Windows
Launchtheinstaller.
Ifyoureceiveawarningagainstrunninganunrecognizedapp,select“MoreInfo”,then“Runany-
way.”
Aftertheinstallationcompletes,Allegowilllaunch.
macOS
DownloadtheAllegoinstaller.
Double-clicktheinstallertolaunch.
DragtheAllegoiconintotheApplicationsfolder.
OpentheApplicationsfolderbydoubleclickingthefoldericon.
IntheApplicationsfolder,double-clicktheAllegoiconwhileholdingdownthecontrolkey(hold-
ingdownthecontrolkeyoverridestheMacOSsecuritycheck,whichisonlyneededduringthe
initiallaunch).
Aftertheinstallationcompletes,Allegowilllaunch.
SmartBox Pro
DATA ACQUISITION AND EXPERIMENTAL MANAGEMENT
NeuroNexus Technologies, Inc. ©2020 | 5200 S. State Street, Suite 200, Ann Arbor, Michigan, 48108, USA
Telephone: +1.734.913.8858 | Fax: +1.734.786.0069 | [email protected]
Page
7
AllegoInterface
AllegoDashboard
CONFIGURATION
System Configuresignalsources,whichportswillbeused,samplingfrequency,and
D/A(Outs).
Electrodes Connectedprobedesignsareselected,alongwithwhichportandSmartLink
headstagewillbeused.
SignalProcessing CreatevariousfiltertypesandcombinethemtocreateDSPgroupings.
SIGNALPROCESSING
Monitor Showsthesignalscurrentlybeingstreamed.
Impedance Impedancetesting.
VISUALIZATION
HDSnapshot Takesahighresolutionstillpictureofsignalsforcloserinspection.
SignalMetrics Configurespikedetectionparametersandviewkeyperformanceindic-
ators/signalqualitycharacteristics.
SpikeGrid Setspikedetectionthresholdusingvoltageorstandarddeviationofback-
groundnoisefromthemean.Displaysdetectedspikesacrossallchannels.
Settings Activatethesoftware,setvisualthemesandsettherecordingfilenameand
location.
SmartBox Pro
DATA ACQUISITION AND EXPERIMENTAL MANAGEMENT
NeuroNexus Technologies, Inc. ©2020 | 5200 S. State Street, Suite 200, Ann Arbor, Michigan, 48108, USA
Telephone: +1.734.913.8858 | Fax: +1.734.786.0069 | [email protected]
Page
8
ActivatingAllego
lLaunchAllego.Onceithasfinishedinitializingandtheprogressbardisappears,navigate
totheleftsideoftheinterfaceandhittheSettingsbutton
lAcquisitionSettingsintheupper-rightliststhedirectorywhereyourrecordingfileswillbe
saved,aswellastherootfilenameofeachfile
lLicenseStatusdisplaysthecurrentstateofyoursoftwareactivation
lIfthestatusisinactive,unknownorexpired,youmay:
1. Clickthe“REQUESTTRIAL”button.Thiswillgranta14-daytriallicense.
2. ChecktheemailsyouhavereceivedfromNeuroNexusforan18-digitlicensekey.Ifyoudo
nothavethisyet,contactNeuroNexusCustomerService([email protected])to
requestalicensekey.Pastethe18-digitkeyintothetextboxlabeled“Activate”andclick
thearrow.
lIfthisisatrialsystem,activationwillextendthelicenseandunlockotherpartsoftheapplic-
ation
lAccepttheEndUserLicenseAgreementtobeginusingAllego
SmartBox Pro
DATA ACQUISITION AND EXPERIMENTAL MANAGEMENT
NeuroNexus Technologies, Inc. ©2020 | 5200 S. State Street, Suite 200, Ann Arbor, Michigan, 48108, USA
Telephone: +1.734.913.8858 | Fax: +1.734.786.0069 | [email protected]
Page
9
lYourlicensekeyallowstwocomputerstorunAllegosimultaneously.Ifyouneedtoactiv-
ate Allego onadifferentcomputer,youmaydeactivatethelicenseononebychoosingthe
Deactivatebutton.Thisremovesthecurrentcomputerfromtheallowedlist,freeingupthe
seattobeusewithanothercomputerinstead.
lIfyoursoftwarehasbeenactivatedbutappearsinactive,unknownorexpired,clickthe
REFRESHbuttontore-attempttoactivate.Ifthisdoesnotwork,checkyourinternetcon-
nection.
SmartBox Pro
DATA ACQUISITION AND EXPERIMENTAL MANAGEMENT
NeuroNexus Technologies, Inc. ©2020 | 5200 S. State Street, Suite 200, Ann Arbor, Michigan, 48108, USA
Telephone: +1.734.913.8858 | Fax: +1.734.786.0069 | [email protected]
Page
10
CheckingHardwareConnection
NavigatetotheDashboardandhittheSystembutton.WiththeSmartBoxProon(pressand
releasetheSmartBoxPropowerLEDswitch)andconnectedtoSmartLinkheadstages,your
softwarerecognizeconnectedSmartLinkheadstagesautomatically.Ifyouareusingadifferent
Intan-basedsystem,clickontheModemenuandselecttheappropriateoption.
OntherightsideofthebottombarintheSystemtab,youcancheckthestatusofconnected
portstotheSmartLinkheadstages.Greenlightindicateswhichportsareinuse.TheSmartBox
Prosupportssimultaneousrecordingofupto512channelsacrossallfourports.Forexample,
belowshowsthestatusoftwo64channelSmartLinkheadstagesconnectedtoportsA,andD.
ThesamplerateontheSystemviewcanbechangedtovaluesbetween1kHzto30kHz.
SmartBox Pro
DATA ACQUISITION AND EXPERIMENTAL MANAGEMENT
NeuroNexus Technologies, Inc. ©2020 | 5200 S. State Street, Suite 200, Ann Arbor, Michigan, 48108, USA
Telephone: +1.734.913.8858 | Fax: +1.734.786.0069 | [email protected]
Page
11
TrainingwithAllego
TofamiliarizeyourselfwithAllegobeforeusingitwithaSmartBoxPro,returntotheDashboard
andselecttheSystemiconifthetabisnotstillopen.FromtheModedropdownmenu,choose
Training:Simulatedspikedata.Thismodesimulateshavinga64channelheadstageconnected
onPortsAandD.YoumayalsotestfilteringoptionsbychoosingTraining:Sinewaves.Sine
modesimulatesa64channelheadstageconnectedonPortsAandC.
SmartBox Pro
DATA ACQUISITION AND EXPERIMENTAL MANAGEMENT
NeuroNexus Technologies, Inc. ©2020 | 5200 S. State Street, Suite 200, Ann Arbor, Michigan, 48108, USA
Telephone: +1.734.913.8858 | Fax: +1.734.786.0069 | [email protected]
Page
12
Quickstreamingandsaving-Determineifaheadstageandprobe
areconnectedproperlyandcanstreamdata
lFromtheDashboard,clicktheMonitoricon
lChooseanameforthismonitorifdesired
lClickStream.Datashouldbegintopopulatethewindow.
a. Ifitdoesnot,navigatetotheSystemviewtoverifythattheSmartBoxPro
detectsyourSmartLinkheadstage(s)
b. Youmightneedtoscalethestreamingtodisplaythewaveformsappropriately.
OnthebottomofMonitorview,clicktheVerticalControlsbuttontoincrease/-
decreasethetimespan,thespacebetweenyourwaveforms,andthemag-
nitudeorresolutionofyoursignals.
lFromtheSignalProcessingtaboftheDashboard,applyafiltersetthatissuitedforyour
research.Formoreinformationaboutthefiltering,refertotechnicaldocument.
SmartBox Pro
DATA ACQUISITION AND EXPERIMENTAL MANAGEMENT
NeuroNexus Technologies, Inc. ©2020 | 5200 S. State Street, Suite 200, Ann Arbor, Michigan, 48108, USA
Telephone: +1.734.913.8858 | Fax: +1.734.786.0069 | [email protected]
Page
13
lTosavestreameddata,clickRecord.Thestreamingandrecordingstatuswillbedisplayed
intheStatusbarvisibleallthroughouttheapplication.
SmartBox Pro
DATA ACQUISITION AND EXPERIMENTAL MANAGEMENT
NeuroNexus Technologies, Inc. ©2020 | 5200 S. State Street, Suite 200, Ann Arbor, Michigan, 48108, USA
Telephone: +1.734.913.8858 | Fax: +1.734.786.0069 | [email protected]
Page
14
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14

NeuroNexus SmartBox Pro Radiens Allego User guide

Type
User guide

NeuroNexus SmartBox Pro Radiens Allego is a cutting-edge data acquisition and experimental management system designed for neuroscience research. It provides high-quality acquisition and recording of up to 512 channels of neural and biological signals, enabling comprehensive electrophysiological studies. With its plug-and-play compatibility with NeuroNexus probes and electrode arrays, this system simplifies experimental setup and streamlines data collection.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI