i3 International Di210 Quick start guide

Category
Security cameras
Type
Quick start guide
A
B
6
5
3-1 Illustration
1. Conduit hole used for surface run
power/video connector
2. bottom case
3. xed bottom case with camera housing
4. Dome cover
5. Zoom lever
6. Focus lever
A. 24VAC/12VDC power input connector
(red+, black-)
B. Video output connector (BNC)
Please Note: See gure 3-5 for an
explanation of Camera Adjustment Functions
3-3 Illustration
1. Screw anchors (x2), supplied
2. Mounting template
3. TP4 x 15 tapping screws (x2)
supplied
SAFETY
1. This quick start guide is designed for users who have an
adequate knowledge of network cameras.
2. Do not touch the imaging surface of the sensor. Use a soft
cloth moistened with alcohol to clean the surface if it is
touched accidentally.
3. Ensure the power supply voltage is correct for the particular
variant of camera before operation.
4. Do not attempt to service this camera yourself unless you
are authorized to do so. Opening the camera may expose
you to electrocution or other hazards. Refer all servicing to
qualied personnel only.
5. For more detail on installation and operation, please refer to
CD provided.
INSTALLATION
The dome camera is a fully integrated enclosure with camera
and lens. Figure 3-1 Camera Parts
Mounting the camera
1. Place the mounting template (supplied) on the mounting
surface and mark the holes (see Figure 3-3).
2. Drill two holes and then insert the screw anchors into the holes.
3. Take off the camera housing.
4. Secure the bottom case to the wall ceiling with the TP4 x 15 mm
tapping screws.
Please Note: Depending on the type of surface, different type of
screws and anchors may be required.
PACKAGE CONTENTS
- One fully assembled camera
- Two screw anchors & TP4x15mm
tapping screws
- One 2nd video monitor output cable
- One mounting template
- One TP1.7 screw
- One logo plate
QUICK START GUIDE
Figure 3-2 Bottom Case Removal
Removing the bottom case
1. Gently turn the camera housing (#4 on
gure 3-2) counter-clockwise to unlock
and pull free of the bottom case (#1).
2. Gently take off the inner liner (#3) from
the two notches (#2) in the housing (#4).
3. Set the dome (and liner) aside.
3-2 Illustration
1. Bottom case
2. Tilt adjustment bracket and thumb nuts,
notches (x2)
3. Inner Liner
4.Camera housing
Figure 3-3 Camera Installation
Di210 / Di210B Indoor Dome
QUICK START GUIDE
Di210 / Di210B Indoor Dome
Adjust the Camera Position
The dome camera has three axes for positioning the camera. While
monitoring the picture on the monitor, adjust the camera position as
follows:
Horizontal Adjustment
Rotate the 3D gimbal in the base. Do not turn the gimbal more than
360º or this may cause the internal cables to twist and break.
Vertical Adjustment
After loosening the thumb nuts, position the camera as desired and
then nger-tighten the thumb nuts to set into place.
Horizontal Rotation for Wall Mount and Tilted Ceilings
Rotate the lens base (maximum 360º) until you are satised with the
scope of view.
Figure 3-4 Camera Adjustment
5
1
2
3
4
3-4 Illustration
1. Tilt adjustment bracket and thumb nuts (x2) for
vertical adjustment
2. Axis ring for horizontal and tilted rotation
3. Zoom lever
4. Focus lever
5. Rotate 3D gimbal in base for horizontal
adjustment
Adjusting the Lens
1.Slightly loosen the zoom lever (#3) counter-
clockwise and adjust the zoom lever to determine
the image view.
2.Slightly loosen the focus lever (#4) counter-
clockwise and adjust the focus for optimal picture
sharpness.
3.Re-tighten the zoom lever and focus lever after
adjustment.
Note: It is important that you lock the zoom and
focus levers after making adjustments to avoid
an unfocused view caused by the surrounding
environment (movement, vibration, temperature
change, etc.).
Optional Camera Settings
See Figure 3-5 for Camera Adjustment Functions located
on the camera board.
Figure 3-5 Camera Adjustment Functions
1
2
3-5 Illustration
1. Monitor out
2. OSD control switch
OSD Control Switch
Use the UP/DOWN/LEFT/RIGHT
functions of the OSD switch and the
ENTER key to control the OSD menu.
Camera
Signal system NTSC
Scanning system 2:1 Interlace
Sync system Internal / Line Lock
Scanning frequency (H) 15.734KHz
Scanning Frequency (V) 59.94Hz,
Day & Night mode Auto / Color / BW (electronic D/N) / EXT
Imaging area 4.9 mm x 3.7 mm
Image sensor 1/3” SONY CCD
Horizontal resolution 600 TVLines
Effective pixels (HxV) 768x494
Built-in lens F1.2, f=2.8~10.5mm
Min. illumination 0.015 lux(F1.2, AGC on, 10 IRE) ; 0.2 lux(F1.2,
AGC on, 50 IRE)
BLC BLC / HSBLC / OFF
OSD Built in
White balance ATW / AWB / INDOOR / OUTDOOR / MANUAL
/ AWC
Electronic Shutter 1/60 / x2 / x4 /...../ FLK (selectable)
D-WDR OFF / INDOOR / OUTDOOR
3DNR ON(Level: 0~100 adjustable) / OFF
S/N ratio More than 50dB (AGC off)
Sense up Level Auto(6 levels selectable) / OFF
View angle Wide= 99.5°(H), 73.2°(V) ; Tele= 27.4°(H),
20.6°(V)
Video output 1Vpp composite output 75 ohm
Gamma correction 0.05~1.0 selectable(default 0.45)
Motion Detection 4 areas
Privacy Mask 8 masks
D-ZOOM ON / OFF
Mirror Off / Mirror / V-Flip / Rotate
Monitor Out Yes
Power supply
Power requirement DC12V / AC24V
Environment
Operating temperature -10ºC ~ 50ºC (14 ºF ~ 122 ºF)
Operating humidity 90% RH
Storage temperature -20ºC ~ 60ºC (-4 ºF ~ 140 ºF)
Mechanism
Dimensions (D X H) 112mm X 100.8 mm (4.41" x 3.97")
Weight(g) 300g approx.
Ordering information C-Di210/ C-Di210B
i³ INTERNATIONAL INC.
1.866.840.0004
www.i3international.com
Canada 780 Birchmount Road,
Unit 16, Scarborough,
ON, M1K 5H4
U.S.A. 440 Lawrence Bell Drive,
Suite 16, Williamsville
NY, 14221
  • Page 1 1
  • Page 2 2

i3 International Di210 Quick start guide

Category
Security cameras
Type
Quick start guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI