Avaya DEFINITY Server CSI Maintenance Manual

  • Hello! I am an AI chatbot trained to assist you with the Avaya DEFINITY Server CSI Maintenance Manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Maintenance for
Avaya DEFINITY® Server CSI
Volumes 1 and 2
Release 1.2
555-233-119
Issue 5
October 2002
Copyright 2002, Avaya Inc.
All Rights Reserved
Notice
Every effort was made to ensure that the information in this document
was complete and accurate at the time of printing. However, informa-
tion is subject to change.
Preventing Toll Fraud
“Toll fraud” is the unauthorized use of your telecommunications sys-
tem by an unauthorized party (for example, a person who is not a cor-
porate employee, agent, subcontractor, or is not working on your
company's behalf). Be aware that there may be a risk of toll fraud
associated with your system and that, if toll fraud occurs, it can result
in substantial additional charges for your telecommunications ser-
vices.
Avaya Fraud Intervention
If you suspect that you are being victimized by toll fraud and you need
technical assistance or support, in the United States and Canada, call
the Technical Service Center's Toll Fraud Intervention Hotline at
1-800-643-2353.
How to Get Help
For additional support telephone numbers, go to the Avaya Web site:
http://www.avaya.com/support/
If you are:
within the United States, click Escalation Lists
outside the United States, click Escalation Lists then Global
Escalation List, for phone numbers for regional Centers of
Excellence.
Providing Telecommunications Security
Telecommunications security (of voice, data, and/or video communi-
cations) is the prevention of any type of intrusion to (that is, either
unauthorized or malicious access to or use of) your company's tele-
communications equipment by some party.
Your company's “telecommunications equipment” includes both this
Avaya product and any other voice/data/video equipment that could be
accessed via this Avaya product (that is, “networked equipment”).
An “outside party” is anyone who is not a corporate employee, agent,
subcontractor, or is not working on your company's behalf. Whereas, a
“malicious party” is anyone (including someone who may be other-
wise authorized) who accesses your telecommunications equipment
with either malicious or mischievous intent.
Such intrusions may be either to/through synchronous (time-multi-
plexed and/or circuit-based) or asynchronous (character-, message-, or
packet-based) equipment or interfaces for reasons of:
Utilization (of capabilities special to the accessed equipment)
Theft (such as, of intellectual property, financial assets, or toll
facility access)
Eavesdropping (privacy invasions to humans)
Mischief (troubling, but apparently innocuous, tampering)
Harm (such as harmful tampering, data loss or alteration,
regardless of motive or intent)
Be aware that there may be a risk of unauthorized intrusions associ-
ated with your system and/or its networked equipment. Also realize
that, if such an intrusion should occur, it could result in a variety of
losses to your company (including but not limited to, human/data pri-
vacy, intellectual property, material assets, financial resources, labor
costs, and/or legal costs).
Responsibility for Your Company’s Telecommunications Security
The final responsibility for securing both this system and its net-
worked equipment rests with you - Avaya’s customer system adminis-
trator, your telecommunications peers, and your managers. Base the
fulfillment of your responsibility on acquired knowledge and
resources from a variety of sources including but not limited to:
Installation documents
System administration documents
Security documents
Hardware-/software-based security tools
Shared information between you and your peers
Telecommunications security experts
To prevent intrusions to your telecommunications equipment, you and
your peers should carefully program and configure:
Your Avaya-provided telecommunications systems and their
• interfaces
Your Avaya-provided software applications, as well as their
underlying hardware/software platforms and interfaces
Any other equipment networked to your Avaya products.
Voice Over Internet Protocol (VoIP)
If the equipment supports Voice over Internet Protocol (VoIP) facili-
ties, you may experience certain compromises in performance, reli-
ability and security, even when the equipment performs as warranted.
These compromises may become more acute if you fail to follow
Avaya's recommendations for configuration, operation and use of the
equipment. YOU ACKNOWLEDGE THAT YOU ARE AWARE OF
THESE RISKS AND THAT YOU HAVE DETERMINED THEY
ARE ACCEPTABLE FOR YOUR APPLICATION OF THE EQUIP-
MENT. YOU ALSO ACKNOWLEDGE THAT, UNLESS
EXPRESSLY PROVIDED IN ANOTHER AGREEMENT, YOU
ARE SOLELY RESPONSIBLE FOR (1) ENSURING THAT YOUR
NETWORKS AND SYSTEMS ARE ADEQUATELY SECURED
AGAINST UNAUTHORIZED INTRUSION AND (2) BACKING
UP YOUR DATA AND FILES.
Standards Compliance
Avaya Inc. is not responsible for any radio or television interference
caused by unauthorized modifications of this equipment or the substi-
tution or attachment of connecting cables and equipment other than
those specified by Avaya Inc. The correction of interference caused by
such unauthorized modifications, substitution or attachment will be
the responsibility of the user. Pursuant to Part 15 of the Federal Com-
munications Commission (FCC) Rules, the user is cautioned that
changes or modifications not expressly approved by Avaya Inc. could
void the users authority to operate this equipment.
Product Safety Standards
This product complies with and conforms to the following interna-
tional Product Safety standards as applicable:
Safety of Information Technology Equipment, IEC 60950, 3rd Edition
including all relevant national deviations as listed in Compliance with
IEC for Electrical Equipment (IECEE) CB-96A.
Safety of Information Technology Equipment, CAN/CSA-C22.2
No. 60950-00 / UL 60950, 3rd Edition
Safety Requirements for Customer Equipment, ACA Technical Stan-
dard (TS) 001 - 1997
One or more of the following Mexican national standards, as applica-
ble: NOM 001 SCFI 1993, NOM SCFI 016 1993, NOM 019 SCFI
1998
The equipment described in this document may contain Class 1
LASER Device(s). These devices comply with the following stan-
dards:
EN 60825-1, Edition 1.1, 1998-01
21 CFR 1040.10 and CFR 1040.11.
The LASER devices operate within the following parameters:
Maximum power output: -5 dBm to -8 dBm
Center Wavelength: 1310 nm to 1360 nm
Luokan 1 Laserlaite
Klass 1 Laser Apparat
Use of controls or adjustments or performance of procedures other
than those specified herein may result in hazardous radiation expo-
sures. Contact your Avaya representative for more laser product infor-
mation.
Electromagnetic Compatibility (EMC) Standards
This product complies with and conforms to the following interna-
tional EMC standards and all relevant national deviations:
Limits and Methods of Measurement of Radio Interference of Infor-
mation Technology Equipment, CISPR 22:1997 and EN55022:1998.
Information Technology Equipment – Immunity Characteristics –
Limits and Methods of Measurement, CISPR 24:1997 and
EN55024:1998, including:
Electrostatic Discharge (ESD) IEC 61000-4-2
Radiated Immunity IEC 61000-4-3
Electrical Fast Transient IEC 61000-4-4
Lightning Effects IEC 61000-4-5
Conducted Immunity IEC 61000-4-6
Mains Frequency Magnetic Field IEC 61000-4-8
Voltage Dips and Variations IEC 61000-4-11
Powerline Harmonics IEC 61000-3-2
Voltage Fluctuations and Flicker IEC 61000-3-3
Federal Communications Commission Statement
Part 15:
For MCC1, SCC1, G600, and CMC1 Media Gateways:
For the G700 Media Gateway:
Part 68: Answer-Supervision Signaling. Allowing this equipment to
be operated in a manner that does not provide proper answer-supervi-
sion signaling is in violation of Part 68 rules. This equipment returns
answer-supervision signals to the public switched network when:
answered by the called station,
answered by the attendant, or
routed to a recorded announcement that can be administered by
the customer premises equipment (CPE) user.
This equipment returns answer-supervision signals on all direct
inward dialed (DID) calls forwarded back to the public switched tele-
phone network. Permissible exceptions are when:
a call is unanswered
a busy tone is received
a reorder tone is received.
Avaya attests that this registered equipment is capable of providing
users access to interstate providers of operator services through the use
of access codes. Modification of this equipment by call aggregators to
block access dialing codes is a violation of the Telephone Operator
Consumers Act of 1990.
For MCC1, SCC1, G600, and CMC1 Media Gateways:
This equipment complies with Part 68 of the FCC rules. On the rear of
this equipment is a label that contains, among other information, the
FCC registration number and ringer equivalence number (REN) for
this equipment. If requested, this information must be provided to the
telephone company.
For the G700 Media Gateway:
This equipment complies with Part 68 of the FCC rules and the
requirements adopted by the ACTA. Located prominently on this
equipment is a label that contains, among other information, a product
identifier in the format US:AAAEQ##TXXXX. The digits represented
by ## are the ringer equivalence number (REN) without a decimal
point (for example, 03 is a REN of 0.3). If requested, this number must
be provided to the telephone company.
The REN is used to determine the quantity of devices which may be
connected to the telephone line. Excessive RENs on the telephone line
may result in devices not ringing in response to an incoming call. In
most, but not all areas, the sum of RENs should not exceed 5.0. To be
certain of the number of devices that may be connected to a line, as
determined by the total RENs, contact the local telephone company.
REN is not required for some types of analog or digital facilities.
Note: This equipment has been tested and found to comply with
the limits for a Class A digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to provide reasonable pro-
tection against harmful interference when the equipment is oper-
ated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interfer-
ence in which case the user will be required to correct the inter-
ference at his own expense.
Note: This equipment has been tested and found to comply with
the limits for a Class B digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to provide reasonable pro-
tection against harmful interference in a residential installation.
This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio
communications. However, there is no guarantee that radio inter-
ference will not occur in a particular installation. If this equip-
ment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference
by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and
receiver.
Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician
for help.
Means of Connection
Connection of this equipment to the telephone network is shown in the
following tables.
For MCC1, SCC1, G600, and CMC1 Media Gateways:
For the G700 Media Gateway:
If the terminal equipment (for example, the MultiVantageSolution
equipment) causes harm to the telephone network, the telephone com-
pany will notify you in advance that temporary discontinuance of ser-
vice may be required. But if advance notice is not practical, the
telephone company will notify the customer as soon as possible. Also,
you will be advised of your right to file a complaint with the FCC if
you believe it is necessary.
The telephone company may make changes in its facilities, equipment,
operations or procedures that could affect the operation of the equip-
ment. If this happens, the telephone company will provide advance
notice in order for you to make necessary modifications to maintain
uninterrupted service.
If trouble is experienced with this equipment, for repair or warranty
information, please contact the Technical Service Center at
1-800-242- 2121 or contact your local Avaya representative. If the
equipment is causing harm to the telephone network, the telephone
company may request that you disconnect the equipment until the
problem is resolved.
A plug and jack used to connect this equipment to the premises wiring
and telephone network must comply with the applicable FCC Part 68
rules and requirements adopted by the ACTA. A compliant telephone
cord and modular plug is provided with this product. It is designed to
be connected to a compatible modular jack that is also compliant. It is
recommended that repairs be performed by Avaya certified techni-
cians.
The equipment cannot be used on public coin phone service provided
by the telephone company. Connection to party line service is subject
to state tariffs. Contact the state public utility commission, public ser-
vice commission or corporation commission for information.
This equipment, if it uses a telephone receiver, is hearing aid compati-
ble.
Canadian Department of Communications (DOC) Interference
Information
For MCC1, SCC1, G600, and CMC1 Media Gateways:
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme
NMB-003 du Canada.
For the G700 Media Gateway:
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme
NMB-003 du Canada.
This equipment meets the applicable Industry Canada Terminal Equip-
ment Technical Specifications. This is confirmed by the registration
number. The abbreviation, IC, before the registration number signifies
that registration was performed based on a Declaration of Conformity
indicating that Industry Canada technical specifications were met. It
does not imply that Industry Canada approved the equipment.
DECLARATIONS OF CONFORMITY
United States FCC Part 68 Suppliers Declaration of Conformity
(SDoC)
Avaya Inc. in the United States of America hereby certifies that the
equipment described in this document and bearing a TIA TSB-168
label identification number complies with the FCC’s Rules and Regu-
lations 47 CFR Part 68, and the Administrative Council on Terminal
Attachments (ACTA) adopted technical criteria.
Avaya further asserts that Avaya handset-equipped terminal equip-
ment described in this document complies with Paragraph 68.316 of
the FCC Rules and Regulations defining Hearing Aid Compatibility
and is deemed compatible with hearing aids.
Copies of SDoCs signed by the Responsible Party in the U. S. can be
obtained by contacting your local sales representative and are avail-
able on the following Web site:
http://www.avaya.com/support/
All MultiVantagesystem products are compliant with FCC Part 68,
but many have been registered with the FCC before the SDoC process
was available. A list of all Avaya registered products may be found at:
http://www.part68.org/
by conducting a search using “Avaya” as manufacturer.
Manufacturer’s Port
Identifier FIC Code SOC/REN/
A.S. Code Network
Jacks
Off/On premises station OL13C 9.0F RJ2GX,
RJ21X,
RJ11C
DID trunk 02RV2-T 0.0B RJ2GX,
RJ21X
CO trunk 02GS2 0.3A RJ21X
02LS2 0.3A RJ21X
Tie trunk TL31M 9.0F RJ2GX
Basic Rate Interface 02IS5 6.0F, 6.0Y RJ49C
1.544 digital interface 04DU9-BN 6.0F RJ48C,
RJ48M
04DU9-IKN 6.0F RJ48C,
RJ48M
04DU9-ISN 6.0F RJ48C,
RJ48M
120A3 channel service unit 04DU9-DN 6.0Y RJ48C
Manufacturer’s Port
Identifier FIC Code SOC/REN/
A.S. Code Network
Jacks
Ground Start CO trunk 02GS2 0.5A RJ11C
DID trunk 02RV2-T AS.0 RJ11C
Loop Start CO trunk 02LS2 0.5A RJ11C
1.544 digital interface 04DU9-BN 6.0Y RJ48C
04DU9-DN 6.0Y RJ48C
04DU9-IKN 6.0Y RJ48C
04DU9-ISN 6.0Y RJ48C
Basic Rate Interface 02IS5 6.0F RJ49C
European Union Declarations of Conformity
Avaya Inc. declares that the equipment specified in this document
bearing the “CE” (Conformité Europeénne) mark conforms to the
European Union Radio and Telecommunications Terminal Equipment
Directive (1999/5/EC), including the Electromagnetic Compatibility
Directive (89/336/EEC) and Low Voltage Directive (73/23/EEC). This
equipment has been certified to meet CTR3 Basic Rate Interface (BRI)
and CTR4 Primary Rate Interface (PRI) and subsets thereof in CTR12
and CTR13, as applicable.
Copies of these Declarations of Conformity (DoCs) can be obtained
by contacting your local sales representative and are available on the
following Web site:
http://www.avaya.com/support/
Japan
For MCC1, SCC1, G600, and CMC1 Media Gateways:
This is a Class A product based on the standard of the Voluntary Con-
trol Council for Interference by Information Technology Equipment
(VCCI). If this equipment is used in a domestic environment, radio
disturbance may occur, in which case, the user may be required to take
corrective actions.
For the G700 Media Gateway:
This is a Class B product based on the standard of the Voluntary Con-
trol Council for Interference by Information Technology Equipment
(VCCI). If this equipment is used in a domestic environment, radio
disturbance may occur, in which case, the user may be required to take
corrective actions.
To order copies of this and other documents:
Call: Avaya Publications Center
Voice 1.800.457.1235 or 1.207.866.6701
FAX 1.800.457.1764 or 1.207.626.7269
Write: Globalware Solutions
200 Ward Hill Avenue
Haverhill, MA 01835 USA
Attention: Avaya Account Management
E-mail: totalwar[email protected]om
Contents
Issue 5 October 2002 7555-233-119
Volume One
About this Book 21
Purpose 21
Intended Audience 21
Organization 22
Conventions Used In This Document 23
Safety Precautions 24
Security Issues 24
Standards Compliance 25
Electromagnetic Compatibility Standards 26
Trademarks and Service Marks 27
How to Order Documentation 28
How to Comment on This Document 28
Where to Call for Technical Support 29
1 Maintenance for CSI systems 31
How to use the Maintenance book 31
CSI design 37
Circuit Packs 40
Maintenance Objects 40
Alarm and Error Reporting 41
Maintenance Testing 42
Preventive Maintenance Procedures 45
Recovery 47
Set Neon Voltage (Ring Ping) 51
Logging On/Off 52
Procedure for SPE-Down Mode 63
Reseating/Replacing Circuit Packs 65
Removing Power 66
Contents
555-233-1198Issue 5 October 2002
Restoring Power 67
System Backup 69
Troubleshooting Features 73
Install DS1 CPE Loopback Jack (T1 Only) 96
LED Interpretation 110
Multimedia Call Handling 115
TN760D Tie Trunk Option Settings 124
TN464E/F/GP Option Settings 126
ATM Tips 127
Unusual ATM trouble conditions 151
Troubleshooting Multimedia Call Handling (MMCH) 154
2 Maintenance Commands 161
System Command Structure 161
busyout access-endpoint 162
busyout board 163
busyout cdr-link 165
busyout data-module 166
busyout journal-printer 167
busyout link 168
busyout mis 169
busyout pms-link 170
busyout port 172
busyout pri-endpoint 173
busyout sp-link 174
busyout station 174
busyout tdm 175
busyout tone-clock 176
busyout trunk 177
cancel hardware-group 179
change circuit-packs 179
change firmware download 181
change ip-network-region 182
Contents
Issue 5 October 2002 9555-233-119
change synchronization 184
change system-parameters maintenance 185
clear audits 196
clear errors 197
clear interface 197
clear isdn-testcall 197
clear link 198
clear mst 198
clear pkt 198
clear port 198
disable administered-connection 199
disable filesystem board ppcss 199
disable firmware download 199
disable mst 199
disable suspend-alm-orig 200
disable synchronization-switch 200
disable test-number 201
display alarms 201
display capacity 206
display communication-interface hop-channels 216
display communication-interface links 217
display disabled-tests 219
display errors 219
display events 226
display failed ip-network-region 241
display firmware download 241
display initcauses 242
display memory-configuration 244
display node-names 245
display port 247
display synchronization 248
display system-parameters duplication 249
display system-parameters maintenance 250
display test-schedule 260
display time 263
Contents
555-233-11910 Issue 5 October 2002
download update-file 264
enable administered-connection 267
enable filesystem board 267
enable mst 267
enable suspend-alm-orig 268
enable synchronization-switch 269
enable test-number 269
get boot-image 269
get ethernet-options 271
get vector 272
list communication-interface processor-channel 274
list configuration 276
list configuration license 279
list configuration software-version 280
list directory 284
list disabled-mos 284
list external-device alarm 285
list history 286
list ip-route 289
list isdn-testcall 290
list marked-ports 291
list measurements clan ethernet 292
list measurements clan ppp 294
list measurements clan sockets 296
list measurements ds-1 298
list measurements ip codec 302
list measurements ip dsp-resource 306
list measurements ip-signaling-group 309
list mst 312
list registered-ip-stations 336
list skill-status 336
list station 338
list suspend-alm-orig 339
list sys-link 340
list testcalls 341
Contents
Issue 5 October 2002 11555-233-119
list trace 346
mark port 348
monitor bcms 349
monitor health 353
monitor security-violations 356
monitor system 357
monitor traffic 362
monitor trunk 364
netstat arp 365
netstat ip-route 368
ping 369
recycle carrier 373
refresh route-table 373
release access-endpoint 375
release board 376
release cdr-link 377
release data-module 378
release journal-printer 379
release link 380
release mis 381
release modem-pool 381
release pms-link 382
release port 383
release pri-endpoint 384
release sp-link 385
release station 386
release tdm 387
release tone-clock 388
release trunk 389
remove file 390
remove license 390
reset board 391
reset io-processor 392
reset interface 392
reset ip-endpoints 393
Contents
555-233-11912 Issue 5 October 2002
reset login-session n 393
reset packet-interface 393
reset switch-control 394
reset system 394
reset system 3 395
reset translation-id 396
reset val 396
restore announcements 397
resume hardware-group 399
save announcements 399
save translation 402
set boot-image 403
set ethernet-options 404
set options 405
set signaling-group 411
set synchronization 411
set tdm 412
set time 413
set tone-clock 414
set vector 414
status access-endpoint 415
status administered-connection 417
status attendant 418
status audits 419
status bri-port 427
status card-mem 433
status cdr-link 437
status cleared-alarm-notif 438
status conference 438
status data-module 474
status esm 476
status firmware download 477
status hardware-group 478
status health 480
status interface 483
Contents
Issue 5 October 2002 13555-233-119
status ip-board 483
status ip-network-region 486
status isdn-testcall 487
status journal-link 489
status link n 490
status logins 494
status packet-interface 495
status pms-link 496
status pri-endpoint 497
status processor-channel 499
status psa 500
status signaling-group 500
status sp-link 503
status station 504
status synchronization 509
status sys-link 511
status system 513
status trunk 517
status tsc-administered 521
status tti 522
status val-ip 524
test access-endpoint 525
test alarms 526
test analog-testcall 532
test board 534
test card-mem 537
test cdr-link 540
test customer-alarm 542
test data-module 544
test ds1-loop 545
test eda-external-device-alrm 548
test environment 549
test failed ip-network-region 552
test firmware download 552
test hardware-group 553
Contents
555-233-11914 Issue 5 October 2002
test inads-link 559
test interface 561
test isdn-testcall 563
test journal-printer 565
test license 567
test led 568
test memory 569
test network-control 571
test pkt 573
test packet-interface 575
test pms-link 576
test port 578
test pri-endpoint 580
test processor 582
test signaling-group 584
test sp-link 586
test station 588
test synchronization 590
test sys-link 592
test tdm 594
test tone-clock 596
test trunk 598
test tsc-administered 600
traceroute 601
upgrade software 603
3 Maintenance Objects 607
ADM-CONN (Administered Connection) 607
ADX8D-BD (AUDIX Circuit Pack) 612
ADX8D-PT (AUDIX Digital Port) 613
ADX16D-B (16 Port AUDIX Circuit Pack) 621
ADX16A-BD (AUDIX Circuit Pack) 622
ADX16D-P (16-Port AUDIX Digital Port) 623
Contents
Issue 5 October 2002 15555-233-119
ADX16A-PT (AUDIX Analog Line/Control Link) 631
ALARM-PT (ALARM PORT) 638
ANL-24-L (24-Port Analog Line) 639
ANL-BD (Analog Line Circuit Pack) 655
ANL-LINE (8-Port Analog Line),
ANL-NE-L (8-Port Neon Analog Line) 656
AN-LN-PT (Analog Line
Port) 675
ANN-BD (Announcement Circuit Pack) 694
ANN-PT (Announcement Port) 712
ANNOUNCE (Announce) 723
ATM-BCH (ATM B-Channel Trunk) 727
ATM-DCH (ATM D-Channel Port) 741
ATM-INTF (TN2305/6) 744
ATM-SGRP (ATM Signaling Group) 747
ATM-TRK (Circuit Emulation Service Circuit Pack) 758
AXA12-BD/ADX8D-BD/AXD12-BD
(AUDIX Circuit Packs) 787
AXA12-RS/ADX8D-RS/AXD12-RS
(AUDIX Reserve Slots) 788
BRI-BD/LGATE-BD (ISDN-BRI Line Circuit Pack) 789
BRI-DAT (ISDN-BRI) 796
BRI-PORT (ISDN-BRI Port),
ABRI-PORT (ASAI ISDN-BRI Port) 797
BRI-SET, ASAI-ADJ, BRI-DAT 819
CABINET (Cabinet Sensors) 846
CAP-MEM (Memory Card Capacity) 852
CARD-MEM (Memory Card) 855
CLAN-BD (Control LAN Circuit Pack) 875
CLSFY-BD (Call Classifier Circuit Pack) 891
CLSFY-PT (Call Classifier Port) 891
CO-BD (Central Office Trunk Circuit Pack) 897
CO-DS1 (DS1 CO Trunk) 898
CO-TRK (CO Trunk) 914
CONFIG (System Configuration) 940
CUST-ALM (Customer-Provided Alarming Device) 941
Contents
555-233-11916 Issue 5 October 2002
Volum e Two
DATA-BD (Data Channel Processor Circuit Pack) 945
DATA-CHL (Data Channel) 950
DATA-CON (Network Control Driver) 975
DAT-LINE (Data Line) 977
DETR-BD (International Version) 985
DID-BD (Direct Inward Dial Trunk Circuit Pack) 985
DID-DS1 (DS1 DID Trunk) 986
DID-TRK (DID Trunk) 997
DIG-BD (Digital Line Circuit Pack) 1013
DIG-IP-STN (Digital IP Station) 1014
DIG-LINE (Digital Line) 1021
DIOD-DS1 (DS1 DIOD Trunk) 1046
DIOD-TRK (DIOD Trunk), DIOD-BD
(DIOD Circuit Pack) 1056
DIOD-TRK (DIOD Trunk) 1056
DLY-MTCE (MO-DAILY) 1066
DS1-BD (DS1 Interface Circuit Pack) 1069
DT-LN-BD (Data Line Circuit Pack) 1145
DTMR-PT [Dual Tone Multifrequency Port (TTR)] 1146
E-DIG-BD (Multi Application Platform Board) 1151
E-DIG-STA (Emulated Digital Line) 1152
EMG-XFER 1162
ERR-LOG (Error Log) 1165
ETH-PT (Control LAN Ethernet) 1166
ETR-PT (Enhanced Tone Receiver Port) 1177
EXT-DEV ADMIN? N (External Device Alarm) 1184
EXT-DEV ADMIN? Y (External Device Alarm) 1187
FW-DWNLD (Firmware Download) 1190
GPTD-PT [General Purpose Tone
Detector Port (CPTR)] 1220
H323-BCH (H.323 B-Channel) 1221
H323-SGRP (323 Signaling Group) 1223
H323-STN (H.323 IP Station) 1230
HYB-BD (Hybrid Line Circuit Pack) 1236
Contents
Issue 5 October 2002 17555-233-119
HYB-LINE (Hybrid Line) 1236
INADS (INADS Link) 1258
IO-PROCR (I/O Processor) 1262
IPMEDPRO (IP Media Processor Circuit Pack) 1265
ISDN-PLK (ISDN-PRI Signaling Link Port) 1281
ISDN-SGR (ISDN-PRI Signaling Group) 1287
ISDN-TRK (DS1 ISDN Trunk) 1303
LIC-ERR (License-Error Mode) 1331
LOG-SVN (Login Security Violation) 1339
JNL-PRNT (Journal Printer Link) 1341
MAPD-BD (MAPD Interface Circuit Pack TN802) 1342
MAPD-RES (TN802 reserve slot) 1373
MEDPRO (Media Processor MAPD Circuit Pack) 1374
MEDPROPT (TN802/TN2302 MED PRO DSP PORT) 1387
MIS (Management Information System) 1395
MMI-BD 1396
MMI-LEV (Multimedia Interface Resource Level) 1405
MMI-PT 1408
MMI-SYNC 1414
NO-LIC (No License) 1416
NR-CONN (Network-Region Connect) 1419
OPS-LINE (DS1 OPS Line) 1422
PE-BCHL (PRI Endpoint Port) 1434
PKT-BUS (Packet Bus) 1454
PKT-INT (Packet Interface) 1462
PMS-LINK (Property Management System Link) 1482
PMS-PRNT/JNL-PRNT (PMS Printer Link) 1490
PPP-PT (Control LAN Packet/Port) 1496
PR-MAINT (Maintenance Processor) 1509
PR-MEM (RISC Memory) 1523
PRI-CDR/SEC-CDR (PRI-CDR Link) 1530
PROCR (RISC Processor Circuit Pack TN2402/TN798) 1537
PROC-SAN (Process Sanity Audits) 1544
RANL-STA (Remote Analog Line
(Station) Port) 1545
Contents
555-233-11918 Issue 5 October 2002
RDIG-STA (Remote Digital Station) 1554
REM-OFF (Remote Office) 1568
RING-GEN (Analog Ring Generator) 1570
S-SYN-BD (Speech Synthesis Circuit Pack) 1574
S-SYN-PT (Speech Synthesis Port) 1575
SEC-CDR (SEC-CDR Link Maintenance) 1587
SW-CTL (Switch Control) 1588
SYNC (Synchronization) 1596
SYS-LINK (System Links) 1603
SYS-PRNT (System Printer) 1608
SYSTEM (System) 1614
TBRI-BD (TN2185
ISDN Trunk-Side BRI) 1616
TBRI-PT (TN2185
ISDN Trunk-Side BRI Port) 1624
TBRI-TRK (TN2185
ISDN Trunk-Side BRI) 1644
TDMODULE (Trunk Data Module) 1655
TDM-BUS (TDM Bus) 1656
TDM-CLK (TDM Bus Clock) 1667
TIE-BD (Tie Trunk Circuit Pack) 1676
TIE-DS1 (DS1 Tie Trunk) 1677
TIE-TRK (Tie Trunk) 1694
TIME-DAY (Time of Day) 1716
TONE-BD (Tone-Clock Circuit Pack) 1718
TONE-PT (Tone Generator) 1729
TRANS-ID (Translation-ID) 1737
TR-LN-BD (Trunk Line
Board) 1742
TSC-ADM (Administered Temporary
Signaling Connections) 1743
TTR-LEV (TTR Level) 1749
UDS1-BD (UDS1 Interface Circuit Pack) 1753
VAL-BD (Voice Announcements
over LAN Circuit Pack) 1857
VAL-PT (Voice Announcements over LAN Packet/Port) 1879
Contents
Issue 5 October 2002 19555-233-119
VC-BD 1884
VC-DSPPT 1888
VC-LEV (Voice Conditioner
DSP Port Level) 1896
VC-SUMPT 1899
WAE-PORT (Wideband Access Endpoint Port) 1904
XXX-BD (Common Port Circuit Pack) 1911
IN Index 1925
Contents
555-233-11920 Issue 5 October 2002
/