ASRock Rack GENOAD12M3-2Q Installation guide

Category
Motherboards
Type
Installation guide
GENOAD12M3-2Q | GENOAD12M3/T
Quick Installation Guide
www.asrockrack.com GENOAD12M3-2Q GENOAD12M3/T
2Motherboard Layout
The server board User's Manual is available for download from the ASRock Rack's ocial website
at http://www.asrockrack.com.
Take note of the following precautions before installing server board components or change any
server board settings.
1. Unplug the power cord from the wall socket before touching any components.
2. To avoid damaging the server board’s components due to static electricity, NEVER place the
server board directly on the carpet or the like. Also remember to use a grounded wrist strap or
touch a safety grounded object before handling the components.
3. Hold components by the edges and do not touch the ICs.
4. Whenever uninstall any component, place it on a grounded anti-static pad or in the bag that
comes with the component.
5. When placing screws into the screw holes to secure the server board to the chassis, please do
not over-tighten the screws! Doing so may damage the server board.
P/N: 15G065297000AK V1.0
*15G065297000AK*
Install the Server Board1
1Insert the server board into the chassis.
2Affix the screws clockwise into the
mounting holes in all of the corners of
the server board.
Do not over-tighten the screws
4Jumper Cap On/O
When the jumper cap is placed on the pins, the
jumper is “Short. If no jumper cap is placed on the
pins, the jumper is “Open”.
e illustration shows a 3-pin jumper whose pin1
and pin2 are “Short” when a jumper cap is placed
on these 2 pins.
SATA_SGPIO1
SATA_SGPIO2
34.01 cm (13.39 in)
24.38 cm (9.6 in)
8.1cm (3.2in)
BAT1
ATXPWR1
FAN1
ATX12V3
M2_1
CPU1_HSBP1
FAN2
ATX12V1ATX12V2
PSU_SMB1
M2_2
USB 3.2 Gen1
T: USB3_2
B: USB3_1
IPMI_LAN
COM1
BIOS
ROM
BMC
ROM
TPM_BIOS_PH1
CPU1
IPMB1
BUZZER1
AUX_PANEL1PANEL1
FAN7
USB3_3_4
FAN8
FAN6
MCIO1
MCIO8
MCIO7
MCIO6
MCIO5
MCIO4
MCIO3
MCIO2
FAN5
SATA_SGPIO4
FAN4
FAN3
SATA_SGPIO3
NMI_BTN1
OCP3
CLRMOS1
NCSI_SEL1
Broadcom
BCM57414
BMC_SMB1
CHASSIS_ID0
GENOAD12M3-2Q
GENOAD12M3/T
DDR5_L1
DDR5_K1
DDR5_J1
DDR5_I1
DDR5_H1
DDR5_G1
UID1
LAN1
LAN2
TR1
PCIE7
PCIE6
NUT60_2 NUT60_1
NUT80_2 NUT80_1
NUT110_2NUT110_1
SPEAKER1
ASPEED
AST2600
BMC_SMB2
PWM_CFG1
Dr. Debug
VGA1
+12VSB_SEL1
DDR5_A1
DDR5_B1
DDR5_C1
DDR5_D1
DDR5_E1
DDR5_F1
PWR1
(GENOAD12M3-2Q only)
(GENOAD12M3-2Q only)
(GENOAD12M3-2Q only)
23
146789
10 11 12 13 14
15
16
17
19
20
21
22
23
242526
18
27282930313233343537 3639 38
404143 42
44
45
46
48
47
49
50
51
52
53
54
55
5
No. Description
1 Clear CMOS Pad (CLRMOS1)
2 Front VGA Header (VGA1)
3 PSU SMBus Header (PSU_SMB1)
4 ATX Power Connector (ATXPWR1)
5 Micro-Hi Power Connector (PWR1)
6 ATX 12V Power Connector (ATX12V1)
7 ATX 12V Power Connector (ATX12V2)
8 ATX 12V Power Connector (ATX12V3)
9SATA SGPIO Connector
(SATA_SGPIO3)
10 SATA SGPIO Connector
(SATA_SGPIO4)
11 System Fan Connector (FAN1)
12 System Fan Connector (FAN2)
13 System Fan Connector (FAN3)
14 System Fan Connector (FAN4)
15 Mini Cool Edge IO Connector (MCIO1)
16 Mini Cool Edge IO Connector (MCIO2)
17 Mini Cool Edge IO Connector (MCIO3)
18 Mini Cool Edge IO Connector (MCIO4)
No. Description
19 AMD Socket SP5
(SM-LGA-6096) (CPU1)
20 PWM Conguration Header
(PWM_CFG1)
21 Mini Cool Edge IO Connector (MCIO5)
22 Mini Cool Edge IO Connector (MCIO6)
23 Mini Cool Edge IO Connector (MCIO7)
24 Mini Cool Edge IO Connector (MCIO8)
25 Auxiliary Panel Header (AUX_PANEL1)
26 System Panel Header (PANEL1)
27 USB 3.2 Gen1 Header (USB3_3_4)
28 System Fan Connector (FAN8)
29 System Fan Connector (FAN6)
30 System Fan Connector (FAN7)
31 System Fan Connector (FAN5)
32 COM Port Header (COM1)
33 SATA SGPIO Connector
(SATA _ SGPIO1)
34 SATA SGPIO Connector
(SATA_SGPIO2)
35 3 x 288-pin DDR5 DIMM Slots
(DDR5_B1, DDR5_D1, DDR5_F1)
36 MC SMBus Header (BMC_SMB2)
37 MC SMBus Header (BMC_SMB1)
38 Intelligent Platform Management Bus
Header (IPMB1)
39 M.2 Socket (M2_2)
(Type 2260/2280/22110)
40 M.2 Socket (M2_1)
(Type 2260/2280/22110)
41 NCSI Mode Jumper (NCSI_SEL1)
42 Chassis ID Jumper (CHASSIS_ID0)
43 Non Maskable Interrupt Button
(NMI_BTN1)
44 Speaker Header (SPEAKER1)
45 Buzzer (BUZZER1)
46 3 x 288-pin DDR5 DIMM Slots
(DDR5_A1, DDR5_C1, DDR5_E1)
47 PCI Express 5.0 x16 Slot (PCIE6)
48 ermal Sensor Header (TR1)
49 PCI Express 5.0 x16 Slot (PCIE7)
50 OCP3 +12VSB Power Jumper
(+12VSB_SEL1)
51 SPI TPM Header (TPM_BIOS_PH1)
52 OCP NIC 3.0 Slot (PCIe5.0 x16) (OCP3)
53 3 x 288-pin DDR5 DIMM Slots
(DDR5_G1, DDR5_I1, DDR5_K1)
54 3 x 288-pin DDR5 DIMM Slots
(DDR5_H1, DDR5_J1, DDR5_L1)*
55 Backplane PCI Express Hot-Plug Con-
nector (CPU1_HSBP1)
I/O Panel3
4
35 6
2
1
No. Description No. Description
1 USB 3.2 Gen1 Ports (USB3_1_2) 4 UID LED (UID_LED1)
2 IPMI LAN Header (IPMI_LAN) 5 25G SFP28 (Fiber) (LAN1, Shared NIC)
(GENOAD12M3-2Q only)
3 UID Switch (UID1) 6 25G SFP28 (Fiber) (LAN2)
(GENOAD12M3-2Q only)
GENOAD12M3-2Q | GENOAD12M3/T
Quick Installation Guide
www.asrockrack.com GENOAD12M3-2Q GENOAD12M3/T
6LAN Port LED Indications
IPMI LAN Port
SFP LAN Port
Tighten the screw with a screwdriver to secure
the module into place. Please do not overtighten
the screw.
5
5Install the Processor and Heatsink
We recommend using the CPU Installation tool to avoid CPU pin-bent problem.
Activity / Link LED Speed LED
Status Description Status Description
O No Link O 10Mbps connection or no
link
Blinking Yellow Data Activity Orange 100Mbps connection
On Link Green 1Gbps connection
Activity / Link LED Speed LED
Status Description Status Description
O No Link O 1G/100Mbps connection
or no link
Blinking Yellow Data Activity Orange 10Gbps connection
On Link Green 25Gbps connection
Locate the screw on the CPU socket
and unscrew it. Open the rst
retention cover.
Open the second bracket. Take out the internal
plastic cover.
Install CPU along with the carrier frame, do not
separate them. Please make sure the carrier frame
with CPU is closely attached to the rail frame while
inserting it.
Close the bracket that holds the CPU.
Close the retention cover. Fasten the
screw.
7M.2 SSD Module Installation
1
2
3
Find the corresponding nut location to be used.
Move the stando based on the module type and
length.
Peel o the yellow protective lm on the nut. Hand
tighten the stando into the desired location.
Gently insert the M.2 module into the slot.
4
e diagrams are for reference only. e actual supported M.2
type varies per motherboard.
8Install the PCIE Card
1Remove the bracket facing the slot that
you intend to use. Keep the screw for
later use.
2Align the card connector with the
slot and press firmly until the card is
completely seated on the slot.
Fasten the card to the chassis with the
screw.
3
*Images shown are for illustrative purposes only and may dier depending on model.
Slot Generation Mechanical Electrical Source
PCIE6 5.0 x16 x16 CPU1
PCIE7 5.0 x16 x16 CPU1
10 Install the Memory
123
Unlock a DIMM slot by
pressing the module clips
outward.
Insert the memory module. Lock the clips.
1
2
5
Install the carrier frame with CPU. Don’t separate them.
Please make sure that the carrier
frame with CPU is closely attached to
the rail frame while inserting it.
Carrier Frame with CPU
Rail Fra me
6
7
8
Install the Heatsink and tighten the
screws in a sequential order 1->2->3-
>4->5->6.
9
10
10-5
10-3 10-1
10-6
10-4
10-2
Set your torque wrench to 1.54 in-lb.
One fourth a turn each time.
Tighten the screws in a sequential order
1 > 2 > 3 > 4 > 5 > 6.
Loosen the screws in a reverse order.
3
4
LAN Port
ACT/LINK LED
SPEED LED
LAN Port
ACT/LINK LED
SPEED LED
(GENOAD12M3-2Q only)
9Install the Power Cables
3V
3V
GND
GND
5V
5V
GND
PWROK_PS
5VSB
12V
12V
3V
12
1
13
24
3V
-12V
GND
PSON#
GND
GND
GND
5V
5V
5V
GND
N/A
4
8
1
5
12V
GND
ATX12V
4
8
1
5
12V
GND
+3.3V
+3.3VSB
PWR1
2
BC A
1
No. 123
Nut Location A B C
PCB Length 6cm 8cm 11cm
Module Type Type 2260 Type 2280 Type 22110
BC A
BC A
20o
BC A
BC A
NUT1NUT2
C
  • Page 1 1
  • Page 2 2

ASRock Rack GENOAD12M3-2Q Installation guide

Category
Motherboards
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI