SDC 526 Installation guide

  • Hello! I have reviewed the installation instructions for the SDC Monitoring Switch Kit ED8200. This kit is designed for monitoring door latch status, integrating with access control systems, and enabling magnetic lock release. The document details wiring and applications such as mantrap logic. I'm ready to answer your questions about it.
  • What does the Monitoring Switch Kit do?
    How can the switch be used with an access controller?
    How can it be used for magnetic lock release?
526
MONITORING SWITCH KIT
CORBIN RUSSWIN ED8200
P:\INST INSTRUCTIONS\EGRESS CONTROLS\INST-526 REV C 07-21 Page 1
Any suggestions or comments to this instruction or
product are welcome. Please contact us through
our website or email engineer@sdcsecurity.com
Remote Latch Status Monitoring:
Retracting the latch by depressing the
push pad provides an output signal for
local or remote visual and audible
annunciation indicating forced entry or
unauthorized egress.
Access Control REX: When connected
to the Request-To-Exit input of a keypad,
card or biometric Access Controller,
depressing the pushpad and retracting the
latch actuates the Latch Status contact,
shunting the control access control alarm
to permit authorized egress and/or
releases the magnetic door lock for
uninhibited egress.
Magnetic Lock Release: Where Access
Controller with REX input is unavailable,
the N/C contact of the switch is wired in
series between the power supply and fail
safe magnetic lock. Depressing the exit
device pushpad retracts the latch, causing
the contact to open, thereby releasing the
magnetic lock for uninhibited egress.
Mantrap Logic: Provides N/O and N/C
contacts required for 2 or more
communicating doors for Interlock and
Mantrap applications.
ORG – N/C
YEL – N/O
WHT - COM
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
[t] 800.413.8783 ■ 805.494.0622 ■ E-mail: [email protected] ■ 801 Avenida Acaso, Camarillo, CA 93012 ■ PO Box 3670, Camarillo, CA 93011
INSTALLATION INSTRUCTIONS
Applications
/