Marantec Comfort 211 EOS Owner's manual

Category
Garage Door Opener
Type
Owner's manual

This manual is also suitable for

Marantec Comfort 211 EOS accu/solar is a versatile garage door operator system suitable for small and medium garage doors weighing up to 75 kg. It features automatic cut-out for open and close positions, obstacle detection for reversing the door, and adjustable speed and force settings. The Comfort 211 EOS accu/solar also includes a solar module for charging the battery, an accumulator unit for backup power, and a hand transmitter for remote control operation.

Marantec Comfort 211 EOS accu/solar is a versatile garage door operator system suitable for small and medium garage doors weighing up to 75 kg. It features automatic cut-out for open and close positions, obstacle detection for reversing the door, and adjustable speed and force settings. The Comfort 211 EOS accu/solar also includes a solar module for charging the battery, an accumulator unit for backup power, and a hand transmitter for remote control operation.

FULL-SERVICE
ANTRIEBSSYSTEME
FÜR GARAGENTORE
ANTRIEBSSYSTEME
FÜR SEKTIONALTORE
ANTRIEBSSYSTEME
F
ÜR SCHIEBETORE
ANTRIEBSSYSTEME
FÜR DREHTORE
ANTRIEBSSYSTEME
FÜR ROLLTORE
PARKSCHRANKEN
SYSTEME
ELEKTRONISCHE
STEUERUNGEN
PRODUKT-SERVICE
ZUBEHÖR
Comfort 211 accu, solar
O
perator System for Garage Doors
GB
Installation and operation instructions
FULL-SERVICE
OPERATOR SYSTEMS
FOR GARAGE DOORS
OPERATOR SYSTEMS
FOR SECTIONAL DOORS
OPERATOR SYSTEMS
F
OR SLIDING GATES
OPERATOR SYSTEMS
FOR HINGED GATES
OPERATOR SYSTEMS
FOR ROLLER SHUTTERS
PARK BARRIER
SYSTEMS
ELECTRONIC
CONTROL UNITS
PRODUCT SERVICE
ACCESSORIES
2 Short instruction for installation and operation, Comfort 211 accu, solar GB (#79226)
2. Table of contents
1. Meaning of symbols . . . . . . . . . . . . . . . . . . .2
2
. Table of contents . . . . . . . . . . . . . . . . . . . . .2
3
. General safety advice . . . . . . . . . . . . . . . . . .3
4. Product overview . . . . . . . . . . . . . . . . . . . . .4
4.1 Comfort 211 accu, solar
supply package . . . . . . . . . . . . . . . . . . .4
4.2 Door variations . . . . . . . . . . . . . . . . . . .7
5. Preparation for mounting . . . . . . . . . . . . . .8
6. Installation . . . . . . . . . . . . . . . . . . . . . . . . . . .8
6.1 Installing the motor unit
and drive boom . . . . . . . . . . . . . . . . . . .8
6.2 Mounting to the door . . . . . . . . . . . . . .9
6.3 Completion of mounting . . . . . . . . . . .10
6.4 Release . . . . . . . . . . . . . . . . . . . . . . . .10
6.5 Mounting of the accumulator unit
(Version accu) . . . . . . . . . . . . . . . . . . .11
6.6 Mounting of the solar module
(Version solar) . . . . . . . . . . . . . . . . . . .12
6.7 Function of the charge regulator . . . . .14
6.8 Control connections . . . . . . . . . . . . . .15
6.9 Accumulator unit . . . . . . . . . . . . . . . . .16
7. Hand transmitter . . . . . . . . . . . . . . . . . . . . .18
7.1 Operation and accessories . . . . . . . . . .18
7.2 Change coding . . . . . . . . . . . . . . . . . .18
8. Initial operation . . . . . . . . . . . . . . . . . . . . .19
8.1 Connecting the operator system . . . . .19
8.2 Overview of the control unit . . . . . . . .19
8.3 Overview of the display functions . . . .20
8.4 Express programming . . . . . . . . . . . . .20
8.5 Function test . . . . . . . . . . . . . . . . . . . .23
9. Extended operator functions . . . . . . . . . . .24
9.1 Programming structure for
extended operator functions
(Example for Level 2, Menu 2) . . . . . . .24
9.2 Functions overview for the levels . . . . .25
10. Messages . . . . . . . . . . . . . . . . . . . . . . . . . . .28
10.1 Malfunctions without error messages .28
10.2 Malfunctions with error messages . . . .29
11. Attachment . . . . . . . . . . . . . . . . . . . . . . . . .31
11.1 Comfort 211 accu, solar
replacement parts overview . . . . . . . . .31
11.2 Technical Data for
Comfort 211 accu, solar . . . . . . . . . . .33
11.3 Manufacturer’s Declaration . . . . . . . . .34
11.4 EC Declaration of Conformity . . . . . . .34
1. Meaning of symbols
Caution!
Danger of personal injuries!
The following safety advice must
be observed at all times so as to avoid
personal injuries!
Attention!
Danger of material damage!
The following safety advice must
be observed at all times so as to avoid
material damages!
Advice / Tip
Control
Reference
i
Advice
Type plate
Type: ________________________________________________
Art.-No.: _____________________________________________
Product-No.: __________________________________________
Short instruction for installation and operation, Comfort 211 accu, solar GB (#79226) 3
Please read carefully!
Target group
This operator system may only be installed, connected and put into
operation by qualified and trained professionals!
Qualified and trained specialist personnel are persons
- who have knowledge of the general and special safety regulations,
- who have knowledge of the relevant electro-technical regulations,
- with training in the use and maintenance of suitable safety
equipment,
- who are sufficiently trained and supervised by qualified electricians,
- who are able to recognise the particular hazards involved when
working with electricity.
- with knowledge regarding applications of the EN 12635 standard
(installation and usage requirements).
Warranty
For an operations and safety warranty, the advice in this instruction
manual has to be observed. Disregarding these warnings may lead to
personal injury or material damage. If this advice is disregarded, the
manufacturer will not be liable for damages that might occur.
Batteries, fuses and bulbs are excluded from warranty.
To avoid installation errors and damage to the door and operator
system, it is imperative that the installation instructions are followed.
The system may only be used after thoroughly reading the respective
mounting and installation instructions.
The installation and operating instructions are to be given to the
door system user, who must keep them safe.
They contain important advice for operation, checks and
maintenance.
This item is produced according to the directives and standards
mentioned in the Manufacturer's Declaration and in the Declaration
of Conformity. The product has left the factory in perfect condition
with regard to safety.
Power-operated windows, doors and gates must be checked by an
expert (and this must be documented) before they are put into
operation and thereafter as required, but at least once a year.
Correct use
The operator system is designed exclusively for opening and closing
garage doors.
The operator must be used in a dry place.
The maximum push and pull force must be observed.
Door requirements
The operator system is suitable for:
- small and medium garage doors up to a door weight of 75 kg
(this corresponds approximately to a door size of
2500 mm x 2150 mm with a weight of approx. 14 kg/sqm).
The door must:
- stand still alone (by balance of springs),
- run smoothly.
Beside the advice in these instructions, please observe the
general safety and accident prevention regulations!
Our sales and supply terms and conditions are effective.
Information on installing the operator system
• Ensure that the door is in good mechanical condition.
• Ensure that the door can stop in any position.
• Ensure that the door can be easily moved in the OPEN and CLOSE
directions.
• Ensure that the door opens and closes properly.
• Remove all unnecessary components from the door (e.g. cables,
chains, brackets).
• Render any installations inoperable that will no longer be needed
after the operator system has been installed.
• Before commencing cabling works it is very important to
disconnect the operator system from the electricity supply
(accumulator unit). Ensure that the electricity supply remains
disconnected throughout the cabling works.
• Adhere to the local protection regulations.
• Lay the electricity supply cables and control cables; these MUST be
laid separately. The controls voltage is 24 V DC.
• Always lay the accumulator line (24 V DC) separately from other
supply lines (230 V).
• Install the operator system with the door in the CLOSED position.
• Install all the impulse transmitters and control devices (e.g. remote
control buttons) within sight of the door and at a safe distance
from the moving parts of the door. A minimum installation height
of 1.5 m must be observed.
• Permanently fix the warning signs, which advise of the danger of
becoming trapped, at conspicuous locations.
• Ensure that no part of the door extends across public footways or
roads when the installation is complete.
Information on commissioning the operator system
After initial operation, the persons responsible for operating the door
system, or their representatives must be familiarised with the use of
the system.
• Make sure that children cannot access the door control unit.
• Before moving the door, make sure that there are neither persons
nor objects in the operating range of the door.
• Test all existing emergency command devices.
• Never insert your hands into a running door or moving parts.
• Pay attention to any parts of the gate system that could cause
crushing or shearing damage or accidents.
The EN 13241-1 regulations must be observed.
Information on servicing the operator system
To ensure proper operation, the following items must be checked
regularly and repaired if necessary. Before any works to the door
system are undertaken, the operator system must be disconnected
from the mains.
• Check once a month to ensure that the operator system reverses if
the door encounters an obstacle. Depending on the operational
direction of the door, place a 50 mm high/wide obstacle in its path.
• Check the settings of the OPEN and CLOSE automatic cut-out
function.
• Check all movable parts of the door and operator system.
• Check the door system for signs of wear or damage.
• Check whether the door can be easily moved by hand.
Information on cleaning the operator system
Never use water jets, high pressure cleaners, acids or bases for
cleaning.
3. General safety advice
4 Short instruction for installation and operation, Comfort 211 accu, solar GB (#79226)
4.1 Comfort 211 accu, solar
supply package
4. Product overview
1 Comfort 211accu, solar motor unit
2 Support plate
3 Door link
5 Lintel joining plate
6 Securing sleeve
7 Door link bracket (2x)
8 Guide rail bracket (2x)
9 Door connector attachment
Standard package
Advice for handling the accumulator unit
• Only charge the accumulator unit in well-ventilated rooms,
otherwise risk of explosion.
• Never short-circuit the accumulator unit.
If the accumulator unit is operated with low accumulator voltage
despite a warning signal from the operator system, total discharge
will cause a defect.
In order to avoid total discharge of the accumulator unit, it has to be
charged as follows:
- when only used once in a while: at least all 2 months,
- if not used latest all 6 months.
In case the system is operated alternately with two accumulators,
make sure that, before you plug in the accumulator plug into the
new accumulator unit, a safety period of approx. 30 sec. is kept.
The lead accumulators contained in the accumulator units are taken
back by the shops and recycled.
Advice for handling the charger
When operating chargers the following risks may occur:
- Risk of explosion
(explosive gases will form during charging the lead accumulator),
- Risk of fire and short-circuit
(electric shock caused by humidity).
In order to avoid hazards:
• make sure that the room is well-ventilated.
• Avoid fire and open light.
• Only use the charger in dry buildings.
• Protect the unit against humidity.
• Protect the unit against oils and sharp edges.
• Check the unit regularly on damages.
Please read carefully!
3. General safety advice
4.1 / 1
1
2
3
4
6
7
8
9
4.1 / 2
5
4. Product overview
Short instruction for installation and operation, Comfort 211 accu, solar GB (#79226) 5
4.1 / 5
„¯
10 Self-tapping screws 6.3 x 16 (4x)
11 Hexagonal head screws M6 x 20 (2x)
12 A8 bolts with SL securing clip
13 Screws 4.0 x 18 (2x)
14 Screws 6.0 x 14 (4x)
15 Bolts 8 x 20
16 Securing clips (2x)
17 Hinge pins ø 6
18 Screws 8.0 x 70 (4x)
19 A8 U-plate (4x)
20 U10 wall plugs (4x)
4.1 / 6
„”
„£
5
„#
„^
„∏
21 Hand transmitter
22 Sun visor clip
23 Modular antenna
24 Transmission plug
25 Adapter sleeve
26 Programming pin
4.1 / 7
„˜„\
27 Release warning decal
28 Warning stickers
4.1 / 4
4.1 / 3
!#
!^
!
5
!\
!”
6 Short instruction for installation and operation, Comfort 211 accu, solar GB (#79226)
4.1 / 9
Solar version
32 Accumulator unit
33 Charge regulator
34 Solar module including 7,5 m connecting cable
35 Charger
36 Plug for solar module
37 Screw kit 8 x 45 (4x)
38 Screw kit M5 x 12 incl. M5 nuts (4x)
39 Fixing angle solar module (2x)
40 Bracket with screws (2x)
§”
§#
§
5
§˜
§\
§·
§^
§£
4. Product overview
4.1 / 8
Accu version
29 Charger
30 Accumulator unit
31 Bracket with screws
„·
§¯
§Ø
Short instruction for installation and operation, Comfort 211 accu, solar GB (#79226) 7
4. Product overview
4.1 / 10
41 Drive boom
In addition to the components included in the standard
package, the following accessories are required for the
i
nstallation:
- drive boom
Drive booms
The motor unit can be combined with various types of
drive boom.
4.2 Door variations
4.2 / 1
The standard package with the appropriate operator
boom is suitable for the following types of door.
Swing out retractable up-and-over door
4.2 / 2
Sectional door
Non-swing out retractable up-and-over door
4.2 / 3
Special accessories are necessary for the following door
type.
6. Installation
8 Short instruction for installation and operation, Comfort 211 accu, solar GB (#79226)
Attention!
In order to guarantee correct mounting,
carry out the following checks before
installing.
Supply package
• Check the package to ensure that all the parts are
included.
• Check that you have all the additional components
that are necessary for your particular installation
requirements.
Door system
Attention!
For garages without a second entrance:
the garage door must be fitted with an
emergency release system to allow
access to the garage if a fault occurs.
If a release kit is used:
• Check that the door locks are functioning correctly.
The door locks may not be disabled under any
circumstances.
If a release kit is not used:
Dismantle or disable the door locks.
• Check that the door to be operated fulfils the
following conditions:
- the door must be easily moveable by hand,
- the door should automatically remain in every
position into which it was moved.
Reference:
In case of using and mounting of
accessories, the enclosed particular
instructions are to be considered.
i
1. Insert unlocking pin.
2. Mount door link.
Unlock carriage.
6.1 Installing the motor unit and drive
boom
1. Insert securing sleeve.
2. Mount lintel joining plate.
6.1 / 1
21
6.1 / 2
2
1
6.1 / 3
5. Preparation for mounting
6. Installation
Short instruction for installation and operation, Comfort 211 accu, solar GB (#79226) 9
1. Put adapter sleeve onto drive shaft.
2
. Mount the rail on the motor housing.
Caution!
The drive boom must be carefully
mounted on the motor unit.
Do not use force, as this could damage
the gear teeth!!
6.1 / 4
2
1
6.2 Mounting to the door
Mounting at the up-and-over door.
10 - 50 mm
Mounting at the sectional door.
10 - 50 mm
Caution!
The operator system must be prevented
from falling before it has been properly
fixed.
Attention!
To ensure that the door travels
correctly:
- the drive rail must be mounted
vertically above the door link bracket,
- at the highest point of the opening
movement, the upper edge of the
door leaf must lie 10 - 50 mm below
the horizontal lower edge of the drive
rail.
6.2 / 1
6.2 / 2
10 Short instruction for installation and operation, Comfort 211 accu, solar GB (#79226)
6. Installation
Mount support clamp.
6.3 / 1
Bend support plate and mount it o the
ceiling.
6.3 / 2
15°- 30°
300 mm
6.4 Release
• Limit the door travel path when opening
by constructing a physical barrier.
• Attach the release pull cord at a minimum height
of 1.8 m.
• Attach the "operating information for release pull
cord" sticker to the pull cord.
Attention!
When the release function is activated,
door movements may be uncontrolled:
- when door springs are weak or
broken.
- when the door is not correctly
balanced.
When opening the door by hand, the
carriage can collide with the operator
unit.
When unlocked, the door may only
be moved with moderate speeds!
1. Separate door and operator.
2. Connect door and operator again.
6.4 / 1
2
1
6.3 Completion of mounting
Short instruction for installation and operation, Comfort 211 accu, solar GB (#79226) 11
1. Mount the accumulator unit.
2. Connect the accumulator unit.
6. Installation
Attention!
In order to protect the accumulator unit against damages,
- make sure that the mounting position is dry,
- never install and operate the accumulator unit with connecting plug down,
- protect the accumulator against falling.
6.5 / 1
6.5 Mounting of the accumulator unit (Version accu)
12 Short instruction for installation and operation, Comfort 211 accu, solar GB (#79226)
1. Align the solar module to the midday sun.
2. Mount the solar module.
6. Installation
6.6 Mounting of the solar module
(Version solar)
Attention!
To guarantee a faultless function, the
solar module must not be scratched
during installation.
Do not fix the screws too tight
because otherwise the module may
be damaged.
M 5x12
A5
2x U-5.3
6.6 / 1
6.6 / 2
Attention!
To guarantee a faultless function:
- align the solar module to midday sun,
- avoid shades from houses or trees,
- keep the module free from snow.
Assemble solar module.
Short instruction for installation and operation, Comfort 211 accu, solar GB (#79226) 13
1. Mount charge regulator (B) and accumulator unit (A).
2. Lay connection cable to charge regulator and accumulator unit.
6. Installation
6.6 / 3
Attention!
In order to avoid damages to the accumulator unit (A) and the charge regulator (B), the mounting place
needs to be dry.
As vibrations could affect the function of the accumulator unit (A) and of the charge regulator (B), they
must be secured against falling.
B
A
14 Short instruction for installation and operation, Comfort 211 accu, solar GB (#79226)
6. Installation
Attention!
To avoid damages to the system and to
guarantee a faultless function:
- observe the sequence of cabling
during mounting,
- observe poling when connecting the
plug.
1. Connect the cable from the charge
regulator (B) with the accumulator unit (A).
2. Lay the cable from the solar module to
the charge regulator.
3. Remove the strain relief (D).
4. Mount the solar module cable (E) to the
plug (C) (+ = brown lead / - = blue lead).
5. Mount the cover (F) and the strain relief (D).
6. Connect the solar module plug (C) with
the charge regulator socket (G).
7. Connect the motor unit plug (I) with the
charge regulator socket (H).
6.6 / 4
A
B
6.6 / 5
-
F
+
C
D
E
6.6 / 6
G
H
I
C
6.7 Function of the charge regulator
A green LED
B fuse
C multicolour LED
Green LED (A) is on:
The solar module produces energy.
Green LED (A) flashes:
The accumulator unit is charged completely, the charge
regulator limits the charging current.
Multicolour LED (C):
The charging status of the accumulator unit is
displayed by colour changes in 10 steps, from green
(accumulator unit charged completely) to red
(accumulator unit empty).
BAC
View on charge regulator.
6.7 / 1
Short instruction for installation and operation, Comfort 211 accu, solar GB (#79226) 15
6. Installation
6.8 Control connections
Attention!
To avoid damages to the control unit:
- Always observe local safety
regulations.
- Always lay mains and control cables
separately.
- Control voltage is 24 V DC.
- External voltage at the terminals
XP020, XB20 or XB02 will destroy the
whole electronics.
- Only connect potential-free closing
contacts to terminals 1 and 2 (XB02).
- The short-circuit plug must not be
inserted into connection XP020!
Reference:
When installing external control
elements, or safety and signal
equipment, the relevant instructions
must be observed.
i
Caution!
Risk of electric shock:
Before cabling works make sure that
the cables are without voltage.
During cabling works make sure that
the cables remain without voltage
(e.g. secure them against being
switched on).
Name Type / function
i
XB02
Connection of external control
elements without system cabling
and 2-wire photocell
6.8/2
XB20
Connection of external control
elements with system cabling
(without function in stand-by
mode).
-
XP020
Connection system photocell or
adapter cable for module anten-
nas (without function in
stand-by mode).
9.2 /
Level 8
XB70 Connection module antenna 8.1
Advice:
Before connecting a control element to
the terminals with system sockets, the
corresponding shorting plug must first
be removed.
1
2
3
70
71
P
1
2
3
4
5
6
7
8
1
2
XB20 XB02 XP020 XB70
Control connections.
6
.8 / 1
16 Short instruction for installation and operation, Comfort 211 accu, solar GB (#79226)
6. Installation
Connection XB02
6.8 / 2
Advice:
If a photocell is to be connected, it
must be installed before the express
programming procedure is carried out.
The photocell will only be recognised
automatically by the controls if this is
the case.
Otherwise the photocell must be
programmed after installation.
Name Type / function
1
24 V DC max. 50 mA
2 Impulse
3 GND
70 GND
70 + 71
2-wire photocell
(Protection category IP 65)
R Receiver of the 2-wire photocell
S1
External impulse button
(if existing)
T Transmitter of the 2-wire photocell
6.9 Accumulator unit
Service life (Accu version)
Under optimal conditions an accumulator unit has a
useful time of approx. 60 days with 4 operating cycles
(opening and closing) per day.
Voltage display
When connecting the accumulator unit to the operator
system, a switch-on check of the accumulator unit is
carried out. In case the accumulator unit is not charged
sufficiently, the operator system gives an alarm via the
integrated voltage display. Then the accumulator unit
must be charged immediately.
The operator system displays decreasing voltage of the
accumulator unit as follows:
6
.9.1 General notes to operate the
accumulator unit
Reference!
To avoid damages and risks, observe
the General Safety Advice for handling
the accumulator unit and the charger
(see point 3).
i
Operating cycles
before end of useful
time
8 6 0
Flashing of light and
beep during door travel
and light time
X X X
Door travel only in the
slow soft run
X X
Closing the door via
radio control is no
longer possible
X
Stand-by
The activation of the operator from the stand-by mode
is possible as follows:
- when the P button is pushed,
- when one of a button on the hand transmitter is
pushed,
- by pushing one of the interior buttons that is
connected to terminals 1 and 2.
Short instruction for installation and operation, Comfort 211 accu, solar GB (#79226) 17
6
.9.2 Charging procedure accu, solar
Displays
red/orange LED (depending on type):
The unit is in charging mode.
green LED:
The unit is charged.
Attention!
Only for solar version:
To guarantee a faultless function
please always observe the following
sequence:
- Only after separating the solar module
from the charge regulator:
remove the accumulator unit from
the charge regulator.
- Only after the accumulator unit has
been connected to the charge
regulator, the solar module may be
connected to the charge regulator.
Separate the solar module from the charge
regulator (only solar version).
Remove the accumulator unit from the
motor unit connection cable.
1. Connect the charge regulator with the
accumulator unit.
2. Plug the charger into the mains socket.
Connect the charged accumulator with the
motor unit connection cable.
Connect the solar module with the charge
regulator (only solar version).
6.9.2 / 1
6.9.2 / 2
6.9.2 / 3
6.9.2 / 4
6.9.2 / 5
6. Installation
18 Short instruction for installation and operation, Comfort 211 accu, solar GB (#79226)
1
7.1 Operation and accessories
Caution!
Children are not allowed to operate the
hand transmitters!
Before operating the hand transmitter,
make sure that there are neither
persons nor objects in the operating
range of the door.
7. Hand transmitter
A Operating button - large
B Operating button - small
C Battery - transmission control light
D Transmission socket
E Back of hand transmitter
F Battery 3V CR 2032
7.2 Change coding
• Connect one end of the transmission plug to the
hand transmitter.
• At the free end of the transmission plug, short-circuit
one of the outer pins with the centre pin adjacent to
it (e.g. using a screw driver).
• Press the desired button on the hand transmitter.
A new code is then generated by the integrated
random coding facility.
The LED flashes quickly.
As soon as the LED lights up permanently, the hand
transmitter has been programmed with a new code.
The button can then be released and the transmission
plug removed.
Advice:
After the hand transmitter has been
re-programmed, the operator system
must also be re-programmed to
respond to the new code.
For multi-channel transmitters, the
programming process must be carried
out for each button separately.
Summary.
Change coding.
Accessory visor clip.
7.1 / 1
D
C
A
D
B
E
F
7.1 / 3
7.2 / 1
Change battery.
7.1 / 2
Short instruction for installation and operation, Comfort 211 accu, solar GB (#79226) 19
1
2
3
70
71
P
1
2
3
4
5
6
7
8
1
2
7
6
8
1
4
32
A
C
B
Summary on control unit.
8.2 / 1
LED displays
1 Photocell
(only lights up if the photocell beam is interrupted)
2 Door position OPEN
3 Has no function
4 Door position CLOSED
5 Reference control point
6 Has no function
7 Impulse
(remote control, external control elements)
8 Operation / stand-by mode
Operating elements
A (+) button (e.g. to drive the door to the OPEN
position or to increase parameters
when programming - in stand-by
mode without function)
B (-) button (e.g. to drive the door to the
CLOSED position or to decrease
parameters when programming -
in stand-by mode without function)
C (P) button (e.g. to switch to programming
mode or to save parameters)
5
8.2 Overview of the control unit
Plug in the antenna.
8.1 / 1
8.1 Connecting the operator system
8. Initial operation
Operation of the P button.
8.4 Express programming
The controls are programmed using the plus (+),
minus (-) and P buttons.
If no buttons are pressed within 120 seconds while in
programming mode, the controls revert to operating
mode.
A corresponding message is displayed.
8.4 / 1
Preconditions
The following conditions must be assured before
express programming can commence:
- the door must be in the CLOSED end position.
- the carriage must be connected up.
Advice:
When programming the OPEN and
CLOSED door positions, the reference
point must be passed.
Attention!
When programming the end positions
travel the door very carefully to the
mechanical end positions because the
fuse in the charge regulator might be
activated and cause an interruption of
power supply.
Advice:
For proper initial operation of the
operator system, the express
programming procedure must be
carried out.
This applies for the initial operation and
after resetting.
LED displays in operating mode
8.3 Overview of the display functions
Photocell beam interrupted
Door moving towards OPEN position
Door in OPEN position
Door moving towards CLOSED position
Door in CLOSED position
Reference point is switched
Permanent actuation of an external control
element
Remote control is actuated
Operating voltage
Operator system in stand-by mode
Legend:
LED off
LED on
LED flashes slowly
LED pulses
LED flashes quickly
Factory default setting
Not possible
8. Initial operation
20 Short instruction for installation and operation, Comfort 211 accu, solar GB (#79226)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

Marantec Comfort 211 EOS Owner's manual

Category
Garage Door Opener
Type
Owner's manual
This manual is also suitable for

Marantec Comfort 211 EOS accu/solar is a versatile garage door operator system suitable for small and medium garage doors weighing up to 75 kg. It features automatic cut-out for open and close positions, obstacle detection for reversing the door, and adjustable speed and force settings. The Comfort 211 EOS accu/solar also includes a solar module for charging the battery, an accumulator unit for backup power, and a hand transmitter for remote control operation.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI