RAIS Opus: A captivating fusion of form and function, this wood-burning stove boasts an impressive heating capacity, capable of radiating warmth across a generous area of up to 100 square meters. With its sleek design and mesmerizing flame display, the RAIS Opus not only elevates the ambiance of any living space but also provides a dependable source of heat for your home.

RAIS Opus: A captivating fusion of form and function, this wood-burning stove boasts an impressive heating capacity, capable of radiating warmth across a generous area of up to 100 square meters. With its sleek design and mesmerizing flame display, the RAIS Opus not only elevates the ambiance of any living space but also provides a dependable source of heat for your home.

ENGLISH RAISmanualforRaisTopasandRaisOpus
1
INSTRUCTIONSFORINSTALLATION,
USEANDMAINTENANCE
RAISTOPAS&RAISOPUS
IMPORTANTINFORMATION
Onfirstlightingthestoveyoumustbecarefuln ottotoucht hepainted
surfacesanditisMOSTIMPORTANTthatthedooriskeptslightly‘ajarin
orderforthedoorsealandsealanttocure.
Thiswillpreventthedoorsealstickingtothepaintedbo dyandbecoming
damaged.
ENGLISH RAISmanualforRaisTopasandRaisOpus
2
ENGLISH RAISmanualforRaisTopasandRaisOpus
3
INTRODUCTION...………………………………………………………….. 4
WARRANTY..……………………………… …………………….………….. 4
SPECIFICATIONS……………………………………………… ………….. 5
CONVECTION………………………………………………………………. 6
INSTALLATIONINSTRUCTIONS ………………………………….……… 7
CHIMNEY………………………………………………………….…………. 89
INSTALLATION…………………………… ………………………………... 10
INSTALLATIONWITHTURNTABLE….…………………………………. 11
CHANGEOFCHIMNEYCONNECTION……………………..….……….. 1214
INSTALLATIONDISTANCETOCOMBU STIBLEWALL……………… 15
GENERALINSTALLATION(RIGHTAN GLE)SECUREBASE….….. 16
CORNERINSTALLATION45°…………………………………. 16
360°SWIVELBASE…………………………………………….. 17
INSTALLATIONDISTANCETONONCO MBUSTIBLEWALL………. 17
FORTHEINSTALLER……………………………………………………… 18
OPERATINGINSTRUCTIONS…………………………………………….. 19
FUEL…………………………………………………………………………... 19
DRYINGANDSTORAGE…………………………………………………… 20
REGULATIONOFCOMBUSTIONAIR…………………………………… 21
USINGTHEWOODBURNINGSTOVE…………………………………… 22
ADJUSTMENTOFAIRDAMPER…………………………………………. 22
CONTROL………………………………… ………………………………….. 22
FIRSTUSAGE………………………………………………………………… 23
LIGHTINGANDFUELLING………………………………………………… 2425
CLEANINGANDCARE………………… ………………………………….. 26
CLEANINGOFTHEFLUEWAYS………………………………………… 27
PROBLEMSOLVING……………………………………………………….. 28
ACCESSORIESANDSPAREPARTS……………………………………. 29
SPAREPARTDIAGRAMRAISTOPAS…….………...…………………. 3031
SPAREPARTDIAGRAMRAISOPUS……....…………………………… 3233
Revision:
Date :2011
RaisTopasandRaisOpus
ENGLISH RAISmanualforRaisTopasandRaisOpus
4
ARaiswoodburningstoveismorethanjustaheatsource:italsoshowsthatyoucare
aboutdesignandqualityinyourhome.
Tomakethemostofyourwoodburningstoveitisimportantthatyoureadthemanual
thoroughlybeforeinstallingandusingit.
Inthecaseofwarrantycoverage,andforgeneralqueriesregardingyourwoodburn
ingstove,itisimportantthatyouknowthestove’sproductionnumber.
Wethereforerecommendthatyounotedownthenumberinthetablebelow.
Theproductionnumberislocatedinthetopoftheconvectionbox.
Warranty
YourRaiswoodburningstovecomeswitha5yearwarranty.
Thewarranty,however,doesnotcoverheatinsulatingmaterials,glassandseals.
TheseareavailabletoorderfromyourlocalRaisdealer/stockist.
Anyalterationsmadetothestovewillvoidthewarranty.
Introduction
ThankyouforpurchasingaRaiswoodburningstove.
TheseapplianceshavebeenapprovedbyHETASas
intermittentoperatingappliancesforburningwoodlogsonly.
ENGLISH RAISmanualforRaisTopasandRaisOpus
5
RAISTOPAS RAISOPUS
Nominaloutput(kW): 5 5
Min./Max.output(kW): 4.7  5.5 4.7  5.5
Heatingarea(m
2
): Approx100 Approx100
Size,widt h/depth/height(mm): 495/485/1300 495/485/1600
Combustionchamberwidth/depth/height(mm). 370/380/411 370/380/411
Recommendedamountofwoodwhenfuelling(kg)
(Basedon2  3logsofwoodapprox.25cm)
1.5 1.5
Min.uptake/Min.draught(Pascal) : 12 12
Weight(kg):  165 180/280
Efficiency(%): 77 77
ParticlesafterNS3058/3059(g/kg): 2.7 2.7
DustmeasuredaccordingtoDin+(mg/Nm
3
):
Smokegasmassflow(g/s): 6.4 6.4
Smokegastemperature(°C): 232 232
Intermittentoperation: Fuellingshouldbeundertaken
within3hours
Specifications
ENGLISH RAISmanualforRaisTopasandRaisOpus
6
Thestovesareequippedwithcooldoorhandles  aRaisspecialfeature whichmeans
youcouldalmostdoawaywithgloves.Beaware,however,thatallexteriorsurfaces
becomehotduringuse  sotakeextremecare.
Convection
Raisstovesareconvectionstoves.Thismeansthatthestove’sbackandsidepanelsare
notoverheated.Convectionmeansthatthereisacirculationofair,whichensuresthat
theheatisdistributedmoreevenlythroughouttheentireroom.Thecoldairissuckedinat
thebaseofthestoveandupthroughtheconvectionchannel,whichrunsalongthe
stove’scombustionchamber.Theheatedaircomesoutatthetopofthestove,which
ensuresacirculationofwarmairthroughouttheroom.
ENGLISH RAISmanualforRaisTopasandRaisOpus
7
InstallationInstructions
Thefollowingpagesgiveinstructionsforthesafeandproperinstallationofthisheating
applianceintheUK.Theseinstructionscoverthebasicprinciplesofinstallation,
althoughsomedetailsmayneedslightmodificationtosuitparticularl ocalsiteconditions.
InallcasestheinstallationmustcomplywithcurrentUKBuildingRegulations,Local
AuthorityByelawsandotherspecificationsorregulationsastheyaffecttheinstallationof
thestove.
PleasenotethatitisalegalrequirementunderEnglandandWalesBuildingRegulations
thattheinstallationofthestoveiseithercarriedoutunderlocalAuthorityBuilding
ControlapprovalorisinstalledbyaCompetentPersonregisteredwithaGovernment
approvedCompetentPersonsScheme.HETASoperatesuchaschemeandalistingof
theirregisteredCompetentPersonscanbefoundontheirwebsiteatwww.hetas.co.uk.
ItshouldbenotedthatthecurrentBuildingRegulationsrequirementsaregivenin
ApprovedDocumentJ.Theserequirementsmayalsobemetbyadoptingtherelevant
recommendationsgiveninBritishStandardsBS8303,BS6461andBS7566.
WARNING.HealthandSafetyAdviceNotice.
TheinstallationofthisheatingapplianceisgovernedbytheHealthandSafetyatWork
Act1974.itistheresponsibilityoftheinstallertoensurethatallrequirementsofthisAct
aremetduringtheinstallationworks.Attentionisdrawninparticulartothefollowing:
Handling: Theapplianceisaheavyitemandadequatefacilitiesmustbeavailable
forloading,unloadingandsitehandling.
FireCement: Sometypesoffirecementarecausticandshouldnotbeallowedtocome
intocontactwiththeskin.Protectiveglovesshouldbewornwhen
handlingfirecement.Incaseofcontactwiththeskin,washimmediately
withplentyofwater.
Asbestos: Thisstovecontainsnoasbestos.Ifthereisapossibilityofdisturbingany
asbestosinthecourseoftheinstallation,thenpleaseseekspecialist
guidanceanduseappropriateprotectiveequipme nt.
MetalParts: Wheninstallingorservicingthisstovecareshouldbetakentoavoidthe
possibilityofpersonalinjury.
ImportantWarning  PreparatoryWorkandsafetyChecks:
· Thisstovemustnotbeinstalledintoachimneywhichservesanyotherheating
appliance.
· Theremustnotbeanextractorfanfittedinthesameroomasthestove,asthiscan
causethestovetoemitfumesintotheroom.
· Ifthisapplianceisinstalledintoanexistingchimney,thechimneymustfirstbe
sweptandexaminedforsoundnessandsuitability,beforetheapplianceisinstalled
(seealsosectionheaded‘Chimney’).
ENGLISH RAISmanualforRaisTopasandRaisOpus
8
Chimney
Thechimneyisthedrivingforcewhichmakesthestovefunction.Inorderforthestoveto
performsatisfactorilythechimneyheightmustbesufficienttoensurethecorrectdraught
of14to18Pa,soastocleartheproductsofcombustionandpreventproblemsofsmoke
leakingintotheroomwhenthestoveislit.
Note:Achimneyheightofnotlessthan4.5metres,measuredverticallyfromtheoutletof
thestovetothetopofthechimney,shouldbesatisfactory.
AlternativelythecalculationproceduregiveninBS5854:1980maybeusedasthebasis
fordecidingwhetheraparticularchimneydesignwillprovidesufficientdraught.
Theoutletfromthechimneyshouldbeabovetheroofofthebuildinginaccordancewith
theprovisionsoftheBuildingRegulationsApprovedDocumentJ.
Iftheinstallationisintoanexistingchimney,thenitmustbesoundandhavenocracksor
otherfaultswhichmayallowfumesintothehouse.Olderproperties,especially,mayhave
chimneyfaultsorthecrosssectionmaybetoolargei.e.morethan230x230mm.
Remedialactionshouldbetakenifrequired,expertadviceshouldbesoughtwhere
required.
Ifthechimneyrequireslining,thenasuitablesolidfuelfluelinermustbeused,in
accordancewithBuildingRegulationsApprovedDocumentJ.
Anyexistingchimneymustbeclearofobstructionandshouldhavebeensweptclean
immediatelybeforetheinstallati onofthestove.Ifthestoveisfittedinplaceofanopen
fire,thenthechimneyshouldbesweptonemonthafterinstallationtoclearanysootfalls
whichmayhaveoccurredduetothedifferenceincombustionbetweenthestoveandthe
openfire.
Ifthereisnoexistingchimneytheneitheraprefabricatedblockchimney,inaccordance
withBuildingRegulationsApprovedDocumentJoratwinwallinsulatedstainlesssteel
fluetoBS4543canbeused.Thesechimneysmustbefittedinaccordancewiththe
manufacturer’sinstructionsandtheBuildingRegulations.
Asinglewallmetalfluepipeissuitableforconnectingthestovetothechimneybutis
notsuitableforusingforthecompletechimney.Thechimneyand
connectingfluepipemusthaveaminimumdiameterof150mmandit’s
dimensionshouldbenotlessthanthesizeoftheoutletsocketofthestovewhichis
150mm.Anybendinthechimneyorconnectingfluepipeshouldnotexceed45°.90°
bendsshouldnotbeused.
Combustiblematerialshouldnotbelocatedwheretheheatdissipatingthroughthe
wallsoffireplacesorfluescouldigniteit.Thereforewheninstallingthestoveinthe
presenceofcombustiblematerialsdueaccountmustbetakenofthe
guidanceontheseparationofcombustiblemateri algiveninBuildingRegulationsAp
provedDocumentJandalsointhesestoveinstructions.
ENGLISH RAISmanualforRaisTopasandRaisOpus
9
Ifitisfoundthatthereisexcessivedraughtinthechimneytheneitheran
adjustablefluedamperoralternativelyadraughtstabilisershouldbefitted.The
adjustablefluedampershouldnotcloseofftheflueentirely,butshouldinits
closedpositionleaveaminimumcontinuousopeningfreeareaofatleast20%
ofthetotalcrosssectionalareaoftheflueorfluepipe.
Adequateprovisione.g.easilyaccessiblesootdoorordoorsmustbeprovided
forsweepingthechimneyandconnectingfluepipe.
Youshouldalsofamiliariseyourselfwiththedraughtconditionsforchimneys
with2flues.
Forstrongdraughts,thechimneyorflueshouldbefittedwithadraught
stabiliser.Inwhichcase,itisimportanttoensurethatthereisafreeflowthrough
areaofminimum20cm
2
whentheregulatinggateisshut.Otherwise,thefuel
energymaynotbeusedoptimally.
If,atanytime,youareunsureabouttheconditionofthechimney,youshould
contactachimneysweep.
Rememberthataccesstothesootdoorshouldbekeptclear.
ENGLISH RAISmanualforRaisTopasandRaisOpus
10
Installation
Itisprohibitedtocarryoutunauthorisedalterationstothestove.
Theremustbeplentyoffreshairintheroomwherethestoveisbeinginstalled,inorderto
ensurepropercombustion.Notethatanymechanicalexhaustventilatione.g.an
extractionhoodmayreducetheairsupply.Anyairgrillesmustbeplacedinsucha
manner,thattheairsupplyisnotblocked.
Thestoveisequippedwithfourconvectionairoutlets,whichmaybeconnectedwith
suitableairductstootherrooms.
BuildingRegulationsApprovedDocumentJgivesspecificguidanceontherequired
permanentventilationintotheroomforcombustionairofsol idfuelappliances.
Thefloorstructuremustbeabletocarrytheweightofthewoodburningstove,aswellas
theweightofachimney,ifnecessary.
WhenyouchoosewheretosetupyourRAISwoodburningstove,youshouldconsiderthe
heatdistributiontotheotherrooms.Thiswillenableyoutogetthebestuseoutofyour
stove.
Thestoveshouldbesetupatasafedistancefrominflammablematerials.
Seethemanufacturer'splateonthewoodburningstove.
ENGLISH RAISmanualforRaisTopasandRaisOpus
11
Installationwithturntable
Ifthestovehasaturntablethenpleasedothefollowing:
Pushthefootpedal/releasearmbackwards,afterwhichthestoveisturnedat15°
intervals.Whenthestoveisinthedesiredposition,letgoofthepedalandturnthestove
lightlyuntilitslipsintoplace.
ENGLISH RAISmanualforRaisTopasandRaisOpus
12
Changeofchimneyconnection
Thestoveisdeliveredreadyfortopoutlet,butitcanbechangedtorearoutletinthe
followingway:
Removethebaffleplateandsmokediverter(seecleaningandcare).
Liftupthereflectorplate,pushoutthe‘knockout’and
putthereflectorplatebackintoplace.
Removethecasingknockout.
ENGLISH RAISmanualforRaisTopasandRaisOpus
13
LoosenthethreeM6nutswithaspanner.
Liftthebackpaneloffthebaseplateandremovethe
knockoutplateinthebackpanel(seeprevious
page)aswellasthereflectorplate.
Itmaybeadvantageoustoloosenthefournutsand
takeoutthereflectorplatebeforeremovingthe
knockoutplateontotheaboveplates.
ENGLISH RAISmanualforRaisTopasandRaisOpus
14
Removetheprotectivecover/sealandplaceoverthe
holeinthetopmakesurethatthesealispositioned
properly.TightentheassemblyusingthethreeM6nuts.
Theflueoutletspigot,whichcanbefoundinthestoveina
bag,andtheholderfortheupperfluediverterare
assembledwith3M6x20nutsandbolts.
Theupperfluediverter,baffleplateandtopplateare
assembledinreverseorder.
ENGLISH RAISmanualforRaisTopasandRaisOpus
15
Installationdistanceincaseofcombustiblewall
Tofindoutwhetherthewallnexttowherethestoveisgoingtobeinstalledisflammable,
youshouldcontactyourbuildingcontractororthelocalbuildingauthorities.
Thehearthshouldbeabletoaccommodatethewei ghtofthestove.Thechimneymustbe
independentlysupportedbywallbracketsoraceilingsupportplate.Theweightofthestove
isindicatedinthebrochure.
Thestoveshouldalwaysbeinstalledonanoncombustiblehearthofasizeandconstruction
thatisinaccordancewiththeprovisionsofthecurrentUKBuildi ngRegulationsApproved
DocumentJ.
Ifthestoveistobeinstalledonawoodenfloor,itmustbecoveredwithanoncombustible
materialatleast12mmthick,inaccordancewithUKBuildingRegulationsApproved
DocumentJ,toadistanceof300mminfrontofthestoveand150mmtoeachside
measuringfromthedoorofthecombustionchamber.
Theclearancedistancestocombustiblematerialbeneath,surroundingoruponthehearth
andwallsadjacenttothehearthshouldcompl ywiththeguidanceontheseparationof
combustiblematerialgiveninUKBuildingRegulationsApprovedDoc umentJandalsoin
thesestoveinstructions.
ENGLISH RAISmanualforRaisTopasandRaisOpus
16
350mm
ENGLISH RAISmanualforRaisTopasandRaisOpus
17
Usinguninsulatedfluepipe,theminimumdistancetoacombustiblewallmustbe450mmor
225mmifthewallisheatshielded(seeSectionJoftheBuildingRegulations)fromtheflue
pipe.
ENGLISH RAISmanualforRaisTopasandRaisOpus
18
FortheInstaller
Finallybeforefiringthestoveforthefirsttimeacheckshouldbemadetoensurethatthe
assemblyandstoveinstallationhasbeensatisfactoryandthattherearenoleaksinany
sealsintheapplianceandapplianceconnecti onstothechimney.
Ensurethattheapplianceandchimneyfluearefunctioningcorrectlybeforefinally
handingovertotheuser.Readthelaterpartsofthismanualforguidanceoncare
requiredwhenfirstlighting.
Informtheuserthattheappliancehasbeencommissionedandreadytouseandgive
instructiononthesafeoperationofthestove.
TheseInstructionsmustbeleftwiththeuserandtheusershouldbeinstructedtokeep
theminasafeplace.
ENGLISH RAISmanualforRaisTopasandRaisOpus
19
ONLYUSERECOMMENDEDFUELS
Thefollowingtableshowsthecalorificvalueofdifferenttypesofwood,whichhavebeen
storedfor2yearsandwhichhavearesidualmoistureof15 17%.
Wood Kgdrywoodprm
3
comparedtobeech/oak
Hornbeam 640 110%
Beechandoak 580 100%
Ash 570 98%
Maple 540 93%
Birch 510 88%
Mountainpine 480 83%
Fir 390 67%
Poplar 380 65%
1kgofwoodyieldsthesameheatenergyirrespectiveofwoodtype.
1kgofbeechmerelytakesuplessspacethan1kgoffir.
Operatinginstructions
PleasenotethatHETASApplianceApprovalonlycoverstheuseofdryseasonedwood
logsonthisappliance.HETASApprovaldoesnotcovertheuseofotherfuelseither
aloneormixedwiththewoodlogs,nordoesitcoverinstructio nsfortheuseofother
fuels.
Fuel
ThestoveisdesignedandapprovedinaccordancewithEN13240andNS3058for
stokingsplit,driedfirewood.Thefirewoodmusthaveawatercontentof1522%andits
max.lengthshouldbethelengthofthecombustionchamberminus5060mm.
Stokingwithwetfirewoodcausesbothsoot,environmentalpollutionandbadfuel
economy.Freshlycutwoodcontainsapprox.5070%waterandisthoroughlyunsuitable
forstoking.Allowatleast1yearofstoragetimefornewlycutwoodbeforeusing.Wood
withadiameterofmorethan100mmshouldbesplit.Regardlessofwoodsize,itshould
alwayshaveatleastonesurfaceareafreeofbark.
Wedonotrecommendstokingwithpainted,lami natedorimpregnatedwood,woodwith
asyntheticsurface,paintedrefusewood,chipboard,plywood,domesticwaste,paper
briquettesandpitcoal,asthiswillproducemalodoroussmoke,whichcouldbe
poisonous.
Whenfiringwiththeabovementioneditemsandamountslargerthanthose
recommended,thestoveissubjectedtoalargeramountofheat,whichresultsina
higherchimneytemperatureandlowerefficiency.Thiscanresultinthestoveand
chimneybecomingdamagedandwouldvoidthewarranty.
Thecalorificvalueofthefirewoodiscloselyconnectedtothemoisturelevel.
Moistfirewoodhasalowheatvalue.Themorewaterthewoodcontains,themore
energyittakesforthiswatertovaporise,resultinginthisenergybeinglost.
ENGLISH RAISmanualforRaisTopasandRaisOpus
20
Dryingandstorage
Dryingwoodtakestime:properairdryingtakesapproximately2years.
Herearesometips:
Storethewoodsawn,splitandstackedinanairy,sunnyplace,whichisprotectedagainst
rain(thesouthsideofthehouseisparticularlysuitable).
Storethefirewoodstacksatahand'sbreadthapart,asthisensuresthattheairflowing
throughtakesthemoisturewithit.Avoidcoveringthefirewoodstackswithplastic,asthis
preventsthemoisturefromescaping.Itisagoodideatobringthefirewoodintothehouse
23daysbeforeyouneedit.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34

RAIS Opus Manual Manual

Category
Wood stove
Type
Manual Manual
This manual is also suitable for

RAIS Opus: A captivating fusion of form and function, this wood-burning stove boasts an impressive heating capacity, capable of radiating warmth across a generous area of up to 100 square meters. With its sleek design and mesmerizing flame display, the RAIS Opus not only elevates the ambiance of any living space but also provides a dependable source of heat for your home.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI