RAIS RONDO 92, RONDO 120 User manual

  • Hello! I am an AI chatbot trained to assist you with the RAIS RONDO 92 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
ENGLISH RAISmanualforRaisRondo92&Rondo120
INSTRUCTIONSFORINSTALLATION,
USEANDMAINTENANCE
RAISRONDO92/120
IMPORTANTINFORMATION
Onfirstlightingthestoveyoumustbecarefuln ottotoucht hepainted
surfacesanditisMOSTIMPORTANTthatthedooriskeptslightly‘ajarin
orderforthedoorsealandsealanttocure.
Thiswillpreventthedoorsealstickingtothepaintedbo dyandbecoming
damaged.
ENGLISH RAISmanualforRaisRondo92&Rondo120
ENGLISH RAISmanualforRaisRondo92&Rondo120
Revision
Date :2011
INTRODUCTION ……………………………………………… ………….. 4
WARRANTY ……………………………………………… …….………….. 4
SPECIFICATIONS……………………………………………… ………….. 5
CONVECTION………………………………………………………………. 6
INSTALLATIONINSTRUCTIONS ………………………………….……… 7
CHIMNEY………………………………………………………….…………. 89
INSTALLATION…………………………… ………………………………... 11
OPERATIONOFSWIVELBASE(RONDO120)……………………….. 11
ADJUSTMENTOFCHIMNEYCONNEC TION…………………………… 1213
INSTALLATIONDISTANCETOCOMBU STIBLEWALL……………… 14
GENERALINSTALLATION(RIGHT ANGLE)SECUREBASE……….. 15
CORNERINSTALLATION45°………………………………………. 15
360°SWIVELBASE…………………………………………………… 16
INSTALLATIONDISTANCETONONCO MBUSTIBLEWALL……….. 16
FORTHEINSTALLER…………………………………………………….... 17
OPERATINGINSTRUCTIONS…………………………………………….. 18
FUEL…………………………………………………………………………... 1819
DRYINGANDSTORAGE…………………………………………………… 19
REGULATIONOFCOMBUSTIONAIR…………………………………… 19
ROOMVENTILATIONANDSTOVES…………………………………….. 19
USINGTHEWOODBURNINGSTOVE…………………………………… 19
ADJUSTMENTOFAIRDAMPER…………………………………………. 20
CONTROL………………………………… ………………………………….. 20
FIRSTUSAGE……………………………………………………………….. 21
LIGHTINGANDFUELLING………………………………………………… 2223
CLEANINGANDCARE………………… ………………………………….. 24
CLEANINGOFTHEFLUEWAYS………………………………………… 25
PROBLEMSOLVING……………………………………………………….. 26
ACCESSORIESANDSPAREPARTS……………………………………. 27
SPAREPARTDIAGRAMRONDO92……………………………………. 2829
SPAREPARTDIAGRAMRONDO192…………………………………… 3031
ENGLISH RAISmanualforRaisRondo92&Rondo120
ARaiswoodburningstoveismorethanjustaheatsource:italsoshowsthatyou
careaboutdesignandqualityinyourhome.
Tomakethemostofyourwoodburningstoveitisimportantthatyoureadthemanual
thoroughlybeforeinstallingandusingit.
Inthecaseofwarrantycoverage,andforgeneralqueriesregardingyourwood
burningstove,itisimportantthatyouknowthestove’sproductionnumber.
Wethereforerecommendthatyounotedownthenumberinthetablebelow.
Theproductionnumberislocatedatthebackofthestoveatthebottom.
Warranty
YourRaiswoodburningstovecomeswitha5yearwarranty.
Thewarranty,however,doesnotcoverheatinsulatingmaterials,glassandseals.
TheseareavailabletoorderfromyourlocalRaisdealer/stockist.
Anyalterationsmadetothestovewillvoidthewarranty.
Introduction
ThankyouforpurchasingaRaiswoodburningstove.
TheseapplianceshavebeenapprovedbyHETASas
intermittentoperatingappliancesforburningwoodlogsonly.
TheseapplianceshavebeenapprovedforuseinSmokelessZones.
ENGLISH RAISmanualforRaisRondo92&Rondo120
RaisRondo92 RaisRondo120
Nominaloutput(kW): 5 5
Min./Max.output(kW): 3.8 3.8
Heatingarea(m
2
): Ca.100 Ca.100
Size,widt h/depth/height(mm): 490  490  920 490  490  1200
Combustionchamberwidth/depth/height(mm). 350  290  355 350  290  355
Recommendedamountofwoodwhenfuelling(kg)
(Basedon2  3logsofwoodapprox.25cm)
1.5 1.5
Min.uptake/Min.draught(Pascal) : 12 12
Weight(kg):  115 140
Efficiency(%) 76 76
ParticlesafterNS3058/3059(g/kg) 2.5 2.5
DustmeasuredaccordingtoDin+(mg/Nm
3
)
Smokegasmassflow(g/s): 4.7 4.7
Smokegastemperature(°C): 246 246
Intermittentoperation: Fuellingshouldbeundertaken
within3hours
ENGLISH RAISmanualforRaisRondo92&Rondo120
Convection
Raisstovesareconvectionstoves.Thismeansthatthestove’sbackandsidepanelsare
notoverheated.Convectionmeansthatthereisacirculationofair,whichensuresthat
theheatisdistributedmoreevenlythroughouttheentireroom.Thecoldairissuckedin
atthebaseofthestoveandupthroughtheconvectionchannel,whichrunsalongthe
stove’scombustionchamber.Theheatedaircomesoutatthetopofthestove,which
ensuresacirculationofwarmairthroughouttheroom.
Thestovesareequippedwithcooldoorhandles  aRaisspecialfeature which
meansyoucouldalmostdoawaywithgloves.Beaware,however,thatallexterior
surfacesbecomehotduringuse  sotakeextremecare.
ENGLISH RAISmanualforRaisRondo92&Rondo120
InstallationInstructions
Thefollowingpagesgiveinstructionsforthesafeandproperinstallationofthisheating
applianceintheUK.Theseinstructionscoverthebasicprinciplesofinstallation,
althoughsomedetailsmayneedslightmodificationtosuitparticularlocalsiteconditions.
InallcasestheinstallationmustcomplywithcurrentUKBuildingRegulations,Local
AuthorityByelawsandotherspecificationsorregulationsastheyaffecttheinstallationof
thestove.
PleasenotethatitisalegalrequirementunderEnglandandWalesBuildingRegulations
thattheinstallationofthestoveiseithercarriedoutunderlocalAuthorityBuilding
ControlapprovalorisinstalledbyaCompetentPersonregisteredwithaGovernment
approvedCompetentPersonsScheme.HETASoperatesuchaschemeandalistingof
theirregisteredCompetentPersonscanbefoundontheirwebsiteatwww.hetas.co.uk.
ItshouldbenotedthatthecurrentBuildingRegulationsrequirementsaregivenin
ApprovedDocumentJ.Theserequirementsmayalsobemetbyadoptingtherelevant
recommendationsgiveninBritishStandardsBS8303,BS6461andBS7566.
WARNING.HealthandSafetyAdviceNotice.
TheinstallationofthisheatingapplianceisgovernedbytheHealthandSafetyatWork
Act1974.itistheresponsibilityoftheinstallertoensurethatallrequirementsofthisAct
aremetduringtheinstallationworks.Attentionisdrawninparticulartothefollowing:
Handling: Theapplianceisaheavyitemandadequatefacilitiesmustbeavailable
forloading,unloadingandsitehandling.
FireCement: Sometypesoffirecementarecausticandshouldnotbeallowedtocome
intocontactwiththeskin.Protectiveglovesshouldbewornwhen
handlingfirecement.Incaseofcontactwiththeskin,washimmediately
withplentyofwater.
Asbestos: Thisstovecontainsnoasbestos.Ifthereisapossibilityofdisturbingany
asbestosinthecourseoftheinstallation,thenpleaseseekspecialist
guidanceanduseappropriateprotectiveequipme nt.
MetalParts: Wheninstallingorservicingthisstovecareshouldbetakentoavoidthe
possibilityofpersonalinjury.
ImportantWarning  Preparato ryWorkandsafetyChecks:
· Thisstovemustnotbeinstalledintoachimneywhichservesanyotherheating
appliance.
· Theremustnotbeanextractorfanfittedinthesameroomasthestove,asthiscan
causethestovetoemitfumesintotheroom.
· Ifthisapplianceisinstalledintoanexistingchimney,thechimneymustfirstbe
sweptandexaminedforsoundnessandsuitability,beforetheapplianceisinstalled
(seealsosectionheaded‘Chimney’).
ENGLISH RAISmanualforRaisRondo92&Rondo120
Chimney
Thechimneyisthedrivingforcewhichmakesthestovefunction.Inorderforthestoveto
performsatisfactorilythechimneyheightmustbesufficienttoensurethecorrectdraught
of14to18Pa,soastocleartheproductsofcombustionandpreventproblemsofsmoke
leakingintotheroomwhenthestoveislit.
Note:Achimneyheightofnotlessthan4.5metres,measuredverticallyfromtheoutletof
thestovetothetopofthechimney,shouldbesatisfactory.
AlternativelythecalculationproceduregiveninBS5854:1980maybeusedasthebasis
fordecidingwhetheraparticularchimneydesignwillprovidesufficientdraught.
Theoutletfromthechimneyshouldbeabovetheroofofthebuildinginaccordancewith
theprovisionsoftheBuildingRegulationsApprovedDocumentJ.
Iftheinstallationisintoanexistingchimney,thenitmustbesoundandhavenocracksor
otherfaultswhichmayallowfumesintothehouse.Olderproperties,especially,mayhave
chimneyfaultsorthecrosssectionmaybetoolargei.e.morethan230x230mm.
Remedialactionshouldbetakenifrequired,expertadviceshouldbesoughtwhere
required.
Ifthechimneyrequireslining,thenasuitablesolidfuelfluelinermustbeused,in
accordancewithBuildingRegulationsApprovedDocumentJ.
Anyexistingchimneymustbeclearofobstructionandshouldhavebeensweptclean
immediatelybeforetheinstallati onofthestove.Ifthestoveisfittedinplaceofanopen
fire,thenthechimneyshouldbesweptonemonthafterinstallationtoclearanysootfalls
whichmayhaveoccurredduetothedifferenceincombustionbetweenthestoveandthe
openfire.
Ifthereisnoexistingchimneytheneitheraprefabricatedblockchimney,inaccordance
withBuildingRegulationsApprovedDocumentJoratwinwallinsulatedstainlesssteel
fluetoBS4543canbeused.Thesechimneysmustbefittedinaccordancewiththe
manufacturer’sinstructionsandtheBuildingRegulations.
Asinglewallmetalfluepipeissuitableforconnectingthestovetothechimneybutis
notsuitableforusingforthecompletechimney.Thechimneyand
connectingfluepipemusthaveaminimumdiameterof150mmandit’s
dimensionshouldbenotlessthanthesizeoftheoutletsocketofthestovewhichis
150mm.Anybendinthechimneyorconnectingfluepipeshouldnotexceed45°.90°
bendsshouldnotbeused.
Combustiblematerialshouldnotbelocatedwheretheheatdissipatingthroughthe
wallsoffireplacesorfluescouldigniteit.Thereforewheninstallingthestoveinthe
presenceofcombustiblematerialsdueaccountmustbetakenoftheguidanceonthe
separationofcombustiblematerialgiveninBuildingRegulationsApprovedDocument
Jandalsointhesestoveinstructions.
ENGLISH RAISmanualforRaisRondo92&Rondo120
Ifitisfoundthatthereisexcessivedraughtinthechimneytheneitheranadjustable
fluedamperoralternativelyadraughtstabilisershouldbefitted.Theadjustableflue
dampershouldnotcloseofftheflueentirely,buts houldinitsclosedpositionleavea
minimumcontinuousopeningfreeareaofatleast20%ofthetotalcrosssectional
areaoftheflueorfluepipe.
Adequateprovisione.g.easilyaccessiblesootdoorordoorsmustbeprovidedfor
sweepingthechimneyandconnectingfluepipe.
Youshouldalsofamiliariseyourselfwiththedraughtconditionsforchimneyswith2
flues.
Forstrongdraughts,thechimneyorflueshouldbefittedwithadraughtstabiliser.In
whichcase,itisimportanttoensurethatthereisafreeflowthroughareaofminimum
20cm
2
whentheregulatinggateisshut.Otherwise,thefuelenergymaynotbeused
optimally.
If,atanytime,youareunsureabouttheconditionofthechimney,youshouldcontact
achimneysweep.
Rememberthataccesstothesootdoorshouldbekeptclear.
ENGLISH RAISmanualforRaisRondo92&Rondo120
ENGLISH RAISmanualforRaisRondo92&Rondo120
Installation
Itisprohibitedtocarryoutunauthorisedalterationstothestove.
Theremustbeplentyoffreshairintheroomwherethestoveisbeinginstalled,inorderto
ensurepropercombustion.Notethatanymechanicalexhaustventilatione.g.an
extractionhoodmayreducetheairsupply.Anyairgrill esmustbeplacedinsucha
manner,thattheairsupplyisnotblocked.
BuildingRegulationsApprovedDocumentJgivesspecificguidanceontherequired
permanentventilationintotheroomforcombustionairofsol idfuelappliances.
Thefloorstructuremustbeabletocarrytheweightofthewoodburningstove,aswellas
theweightofachimney,ifnecessary.
WhenyouchoosewheretosetupyourRAISwoodburningstove,youshouldconsiderthe
heatdistributiontotheotherrooms.Thiswillenableyoutogetthebestuseoutofyour
stove.
Thestoveshouldbesetupatasafedistancefrominflammablematerials.
Seethemanufacturer'splateonthewoodburningstove.
Installationwithturntable(RaisRondo120)
Ifthestovehasaturntablethenpleasedothefollowing:
Push/pullthepedalin15°i ntervals.Whenthestoveisinthedesiredposition,letgoof
thepedalandturnthestovelightlyuntilitsli psintoplace.
ENGLISH RAISmanualforRaisRondo92&Rondo120
Adjustmentofthechimneyconnection
Thestoveisalwaysdeliveredfortopflueconnection,butcanbechangedtorearflue
connectionasfollows:
Removethebaffleplate
andsmokediverter(see
cleaningandcare).
LoosenthethreeM6nutswithaspanner.
Makesurethattheflue
diverterisfastenedtothe
protectivecover.
Liftupthereflectorplate,pushoutthe‘knockout’
andputthereflectorplatebackintoplace.
ENGLISH RAISmanualforRaisRondo92&Rondo120
Removethecasingknockout.
Removetheprotectivecover/sealandplaceoverthe
holeinthetopmakesurethatthesealispositioned
properly.TightentheassemblyusingthethreeM6nuts.
Theflueoutletspigot,whichcanbefoundinthestoveina
bag,andtheholderfortheupperfluediverterare
assembledwith3M6x20nutsandbolts.
Theupperfluediverter,baffleplateandtopplateare
assembledinreverseorder.
ENGLISH RAISmanualforRaisRondo92&Rondo120
Installationdistancetocombustiblewall
Tofindoutwhetherthewallnexttowherethestoveisgoingtobeinstalledisflammable,
youshouldcontactyourbuildingcontractororthelocalbuildingauthorities.
Thehearthshouldbeabletoaccommodatethewei ghtofthestove.Thechimneymust
beindependentlysupportedbywallbracketsoraceilingsupportplate.Theweightofthe
stoveisindicatedinthebrochure.
Thestoveshouldalwaysbeinstalledonanoncombustiblehearthofasizeand
constructionthatisinaccordancewiththeprovisionsofthecurrentUKBuilding
RegulationsApprovedDocumentJ.
Ifthestoveistobeinstalledonawoodenfloor,itmustbecoveredwitha
noncombustiblematerialatleast12mmthick,inaccordancewithUKBuilding
RegulationsApprovedDocumentJ,toadistanceof300mminfrontofthestoveand
150mmtoeachsidemeasuringfromthedoorofthecombustionchamber.
Theclearancedistancestocombustiblematerialbeneath,surroundingoruponthe
hearthandwallsadjacenttothehearthshouldcomplywiththeguidanceonthe
separationofcombustiblematerialgiveninUKBuildingRegulationsApproved
DocumentJandalsointhesestoveinstructions.
Informtheuserthattheappliancehasbeencommissionedandreadytouseandgive
instructiononthesafeoperationofthestove.
TheseInstructionsmustbeleftwiththeuserandtheusershouldbeinstructedtokeep
theminasafeplace.
ENGLISH RAISmanualforRaisRondo92&Rondo120
ENGLISH RAISmanualforRaisRondo92&Rondo120
ENGLISH RAISmanualforRaisRondo92&Rondo120
FortheInstaller
Finallybeforefiringthestoveforthefirsttimeacheckshouldbemadetoensurethatthe
assemblyandstoveinstallationhasbeensatisfactoryandthattherearenoleaksinany
sealsintheapplianceandapplianceconnecti onstothechimney.
Ensurethattheapplianceandchimneyfluearefunctioningcorrectlybeforefinally
handingovertotheuser.Readthelaterpartsofthismanualforguidanceoncare
requiredwhenfirstlighting.
Informtheuserthattheappliancehasbeencommissionedandreadytouseandgive
instructiononthesafeoperationofthestove.
TheseInstructionsmustbeleftwiththeuserandtheusershouldbeinstructedtokeep
theminasafeplace.
ENGLISH RAISmanualforRaisRondo92&Rondo120
ONLYUSERECOMMENDEDFUELS
Thefollowingtableshowsthecalorificvalueofdifferenttypesofwood,whichhavebeen
storedfor2yearsandwhichhavearesidualmoistureof15 17%.
Wood Kgdrywoodprm
3
comparedtobeech/oak
Hornbeam 640 110%
Beechandoak 580 100%
Ash 570 98%
Maple 540 93%
Birch 510 88%
Mountainpine 480 83%
Fir 390 67%
Poplar 380 65%
1kgofwoodyieldsthesameheatenergyirrespectiveofwoodtype.
1kgofbeechmerelytakesuplessspacethan1kgoffir.
Operatinginstructions
PleasenotethatHETASApplianceApprovalonlycoverstheuseofdryseasonedwood
logsonthisappliance.HETASApprovaldoesnotcovertheuseofotherfuelseither
aloneormixedwiththewoodlogs,nordoesitcoverinstructio nsfortheuseofother
fuels.
Fuel
ThestoveisdesignedandapprovedinaccordancewithEN13240andNS3058for
stokingsplit,driedfirewood.Thefirewoodmusthaveawatercontentof1522%andits
max.lengthshouldbethelengthofthecombustionchamberminus5060mm.
Stokingwithwetfirewoodcausesbothsoot,environmentalpollutionandbadfuel
economy.Freshlycutwoodcontainsapprox.5070%waterandisthoroughlyunsuitable
forstoking.Allowatleast1yearofstoragetimefornewlycutwoodbeforeusing.Wood
withadiameterofmorethan100mmshouldbesplit.Regardlessofwoodsize,itshould
alwayshaveatleastonesurfaceareafreeofbark.
Wedonotrecommendstokingwithpainted,laminatedorimpregnatedwood,woodwith
asyntheticsurface,paintedrefusewood,chipboard,plywood,domesticwaste,paper
briquettesandpitcoal,asthiswillproducemalodoroussmoke,whichcouldbe
poisonous.
Whenfiringwiththeabovementioneditemsandamountslargerthanthose
recommended,thestoveissubjectedtoalargeramountofheat,whichresultsina
higherchimneytemperatureandlowerefficiency.Thiscanresultinthestoveand
chimneybecomingdamagedandwouldvoidthewarranty.
Thecalorificvalueofthefirewoodiscloselyconnectedtothemoisturelevel.
Moistfirewoodhasalowheatvalue.Themorewaterthewoodcontains,themore
energyittakesforthiswatertovaporise,resultinginthisenergybeinglost.
ENGLISH RAISmanualforRaisRondo92&Rondo120
Dryingandstorage
Dryingwoodtakestime:properairdryingtakesapproximately2years.
Herearesometips:
Storethewoodsawn,splitandstackedinanairy,sunnyplace,whichisprotectedagainst
rain(thesouthsideofthehouseisparticularlysuitable).
Storethefirewoodstacksatahand'sbreadthapart,asthisensuresthattheairflowing
throughtakesthemoisturewithit.Avoidcoveringthefirewoodstackswithplastic,asthis
preventsthemoisturefromescaping.Itisagoodideatobringthefirewoodintothehouse
23daysbeforeyouneedit.
Regulatingthecombustionair
AllRAISstovesareequippedwithaonehandedoperatingleverforregulatingthedamper.
Thestovespecificregulatingmechanismscanbeseenonthediagrams.
Primaryairisthecombustionairaddedtotheprimarycombustionzone,i.e.thebedof
glowingembers.Thisair,whichiscold,isonlyusedinthelightingstage.Secondaryai ris
theairwhichisaddedinthegascombustionzone,i.e.airwhichcontributestothe
combustionofthepyrolysisgasses(preheatedair,whichisusedforthecleanerglass
systemandcombustion).Thisairi ssuckedthroughthedamperunderthecombustion
chamberandispreheatedthroughthesidechannelsandthenemittedashotscavenging
airontotheglass.Thehotairrinsestheglassandkeepsitsootfree.
Thetertiarychannel,whichcanbeseenatthetopofthecombustionchambertowardsthe
back,servestocombustthefinalgasresidues.
Bysettingtheintervalbetweenposition1and2,theenergycontentinthefirewoodisused
optimally,asthereisoxygenforcombustionandfortheburningofthepyrolysisgasses.
Whentheflamesareaclearyellowthedamperhasbeensetcorrectly.Findingthecorrect
positioncomeswithtimeafteryouhaveusedforstoveforawhile.
Itisnotrecommendedthatyouturnitdowncompletely.Amistakecommonlymadeis
shuttingthedampertooearlybecauseitfeelstoohot.Thisresultsindarksmokeemanating
fromthechimneyandinthecalorificvalueofthefirewoodnotbeingusedtoitsfullest.
Roomventilationandstoves
Theremustnotbeanextractorfanfittedinthesameroomasthestoveasthiscancause
thestovetoemitsmokeandfumesintotheroom.
Thestoverequiresapermanentandadequateairsupplyinorderforittooperatesafelyand
efficiently.
InaccordancewithcurrentBuildingRegulationstheinstallermayhavefittedapermanentair
supplyventintotheroominwhichthestoveisinstalledtoprovidecombustionair.Thisair
ventshouldnotunderanycircumstancesbeshutofforsealed.
ENGLISH RAISmanualforRaisRondo92&Rondo120
Usingthewoodburningstove
Adjustingtheairdamper.
Thedamperhas3settings.
Position1
Thedamperisalmostclosedmeaningthatthereisa
minimalairintake.
Position2
Pushthelevertotherightuntilitstops.Thisposition
givesfullsecondaryair.
Duringnormalusetheleverissetbetweenposition1
and2.
Whentheflamesareclearandyellow,thedamperis
setcorrectly,i.e.resultinginaslow/optimalburning.
Position3
Pushtheleverupwardsandtotheright.
Theairdamperiscompletelyopenandgivesfull
primaryandsecondaryair.Thispositi onisforthe
lightingstageandisnotusedundernormal operation.
Control
Iftheashiswhiteandthewallsinthecombustionchamberaresootfreeafterthestove
hasbeenused,theairregulationwassetcorrectlyandthewoodwassufficientlydry.
/