IMPORTANTINFORMATION
Onfirstlightingthestoveyoumustbecarefuln ottotoucht hepainted
surfacesanditisMOSTIMPORTANTthatthedooriskeptslightly‘ajarin
orderforthedoorsealandsealanttocure.
Thiswillpreventthedoorsealstickingtothepaintedbo dyandbecoming
damaged.
ENGLISH RAISmanualforRaisTopasandRaisOpus
2
ENGLISH RAISmanualforRaisTopasandRaisOpus
3
INTRODUCTION...………………………………………………………….. 4
WARRANTY..……………………………… …………………….………….. 4
SPECIFICATIONS……………………………………………… ………….. 5
CONVECTION………………………………………………………………. 6
INSTALLATIONINSTRUCTIONS ………………………………….……… 7
CHIMNEY………………………………………………………….…………. 89
INSTALLATION…………………………… ………………………………... 10
INSTALLATIONWITHTURNTABLE….…………………………………. 11
CHANGEOFCHIMNEYCONNECTION……………………..….……….. 1214
INSTALLATIONDISTANCETOCOMBU STIBLEWALL……………… 15
GENERALINSTALLATION(RIGHTAN GLE)SECUREBASE….….. 16
CORNERINSTALLATION45°…………………………………. 16
360°SWIVELBASE…………………………………………….. 17
INSTALLATIONDISTANCETONONCO MBUSTIBLEWALL………. 17
FORTHEINSTALLER……………………………………………………… 18
OPERATINGINSTRUCTIONS…………………………………………….. 19
FUEL…………………………………………………………………………... 19
DRYINGANDSTORAGE…………………………………………………… 20
REGULATIONOFCOMBUSTIONAIR…………………………………… 21
USINGTHEWOODBURNINGSTOVE…………………………………… 22
ADJUSTMENTOFAIRDAMPER…………………………………………. 22
CONTROL………………………………… ………………………………….. 22
FIRSTUSAGE………………………………………………………………… 23
LIGHTINGANDFUELLING………………………………………………… 2425
CLEANINGANDCARE………………… ………………………………….. 26
CLEANINGOFTHEFLUEWAYS………………………………………… 27
PROBLEMSOLVING……………………………………………………….. 28
ACCESSORIESANDSPAREPARTS……………………………………. 29
SPAREPARTDIAGRAMRAISTOPAS…….………...…………………. 3031
SPAREPARTDIAGRAMRAISOPUS……....…………………………… 3233
Revision:
Date :2011
RaisTopasandRaisOpus
ENGLISH RAISmanualforRaisTopasandRaisOpus
4
ARaiswoodburningstoveismorethanjustaheatsource:italsoshowsthatyoucare
aboutdesignandqualityinyourhome.
Tomakethemostofyourwoodburningstoveitisimportantthatyoureadthemanual
thoroughlybeforeinstallingandusingit.
Inthecaseofwarrantycoverage,andforgeneralqueriesregardingyourwoodburn
ingstove,itisimportantthatyouknowthestove’sproductionnumber.
Wethereforerecommendthatyounotedownthenumberinthetablebelow.
Theproductionnumberislocatedinthetopoftheconvectionbox.
Warranty
YourRaiswoodburningstovecomeswitha5yearwarranty.
Thewarranty,however,doesnotcoverheatinsulatingmaterials,glassandseals.
TheseareavailabletoorderfromyourlocalRaisdealer/stockist.
Anyalterationsmadetothestovewillvoidthewarranty.
Introduction
ThankyouforpurchasingaRaiswoodburningstove.
TheseapplianceshavebeenapprovedbyHETASas
intermittentoperatingappliancesforburningwoodlogsonly.
ENGLISH RAISmanualforRaisTopasandRaisOpus
5
RAISTOPAS RAISOPUS
Nominaloutput(kW): 5 5
Min./Max.output(kW): 4.7  5.5 4.7  5.5
Heatingarea(m
2
): Approx100 Approx100
Size,widt h/depth/height(mm): 495/485/1300 495/485/1600
Combustionchamberwidth/depth/height(mm). 370/380/411 370/380/411
Recommendedamountofwoodwhenfuelling(kg)
(Basedon2  3logsofwoodapprox.25cm)
1.5 1.5
Min.uptake/Min.draught(Pascal) : 12 12
Weight(kg):  165 180/280
Efficiency(%): 77 77
ParticlesafterNS3058/3059(g/kg): 2.7 2.7
DustmeasuredaccordingtoDin+(mg/Nm
3
):
Smokegasmassflow(g/s): 6.4 6.4
Smokegastemperature(°C): 232 232
Intermittentoperation: Fuellingshouldbeundertaken
within3hours
Specifications
ENGLISH RAISmanualforRaisTopasandRaisOpus
6
Thestovesareequippedwithcooldoorhandles  aRaisspecialfeature whichmeans
youcouldalmostdoawaywithgloves.Beaware,however,thatallexteriorsurfaces
becomehotduringuse  sotakeextremecare.
Convection
Raisstovesareconvectionstoves.Thismeansthatthestove’sbackandsidepanelsare
notoverheated.Convectionmeansthatthereisacirculationofair,whichensuresthat
theheatisdistributedmoreevenlythroughouttheentireroom.Thecoldairissuckedinat
thebaseofthestoveandupthroughtheconvectionchannel,whichrunsalongthe
stove’scombustionchamber.Theheatedaircomesoutatthetopofthestove,which
ensuresacirculationofwarmairthroughouttheroom.
ENGLISH RAISmanualforRaisTopasandRaisOpus
7
InstallationInstructions
Thefollowingpagesgiveinstructionsforthesafeandproperinstallationofthisheating
applianceintheUK.Theseinstructionscoverthebasicprinciplesofinstallation,
althoughsomedetailsmayneedslightmodificationtosuitparticularl ocalsiteconditions.
InallcasestheinstallationmustcomplywithcurrentUKBuildingRegulations,Local
AuthorityByelawsandotherspecificationsorregulationsastheyaffecttheinstallationof
thestove.
PleasenotethatitisalegalrequirementunderEnglandandWalesBuildingRegulations
thattheinstallationofthestoveiseithercarriedoutunderlocalAuthorityBuilding
ControlapprovalorisinstalledbyaCompetentPersonregisteredwithaGovernment
approvedCompetentPersonsScheme.HETASoperatesuchaschemeandalistingof
theirregisteredCompetentPersonscanbefoundontheirwebsiteatwww.hetas.co.uk.
ItshouldbenotedthatthecurrentBuildingRegulationsrequirementsaregivenin
ApprovedDocumentJ.Theserequirementsmayalsobemetbyadoptingtherelevant
recommendationsgiveninBritishStandardsBS8303,BS6461andBS7566.
WARNING.HealthandSafetyAdviceNotice.
TheinstallationofthisheatingapplianceisgovernedbytheHealthandSafetyatWork
Act1974.itistheresponsibilityoftheinstallertoensurethatallrequirementsofthisAct
aremetduringtheinstallationworks.Attentionisdrawninparticulartothefollowing:
Handling: Theapplianceisaheavyitemandadequatefacilitiesmustbeavailable
forloading,unloadingandsitehandling.
FireCement: Sometypesoffirecementarecausticandshouldnotbeallowedtocome
intocontactwiththeskin.Protectiveglovesshouldbewornwhen
handlingfirecement.Incaseofcontactwiththeskin,washimmediately
withplentyofwater.
Asbestos: Thisstovecontainsnoasbestos.Ifthereisapossibilityofdisturbingany
asbestosinthecourseoftheinstallation,thenpleaseseekspecialist
guidanceanduseappropriateprotectiveequipme nt.
MetalParts: Wheninstallingorservicingthisstovecareshouldbetakentoavoidthe
possibilityofpersonalinjury.
ImportantWarning  PreparatoryWorkandsafetyChecks:
· Thisstovemustnotbeinstalledintoachimneywhichservesanyotherheating
appliance.
· Theremustnotbeanextractorfanfittedinthesameroomasthestove,asthiscan
causethestovetoemitfumesintotheroom.
· Ifthisapplianceisinstalledintoanexistingchimney,thechimneymustfirstbe
sweptandexaminedforsoundnessandsuitability,beforetheapplianceisinstalled
(seealsosectionheaded‘Chimney’).
ENGLISH RAISmanualforRaisTopasandRaisOpus
8
Chimney
Thechimneyisthedrivingforcewhichmakesthestovefunction.Inorderforthestoveto
performsatisfactorilythechimneyheightmustbesufficienttoensurethecorrectdraught
of14to18Pa,soastocleartheproductsofcombustionandpreventproblemsofsmoke
leakingintotheroomwhenthestoveislit.
Note:Achimneyheightofnotlessthan4.5metres,measuredverticallyfromtheoutletof
thestovetothetopofthechimney,shouldbesatisfactory.
AlternativelythecalculationproceduregiveninBS5854:1980maybeusedasthebasis
fordecidingwhetheraparticularchimneydesignwillprovidesufficientdraught.
Theoutletfromthechimneyshouldbeabovetheroofofthebuildinginaccordancewith
theprovisionsoftheBuildingRegulationsApprovedDocumentJ.
Iftheinstallationisintoanexistingchimney,thenitmustbesoundandhavenocracksor
otherfaultswhichmayallowfumesintothehouse.Olderproperties,especially,mayhave
chimneyfaultsorthecrosssectionmaybetoolargei.e.morethan230x230mm.
Remedialactionshouldbetakenifrequired,expertadviceshouldbesoughtwhere
required.
Ifthechimneyrequireslining,thenasuitablesolidfuelfluelinermustbeused,in
accordancewithBuildingRegulationsApprovedDocumentJ.
Anyexistingchimneymustbeclearofobstructionandshouldhavebeensweptclean
immediatelybeforetheinstallati onofthestove.Ifthestoveisfittedinplaceofanopen
fire,thenthechimneyshouldbesweptonemonthafterinstallationtoclearanysootfalls
whichmayhaveoccurredduetothedifferenceincombustionbetweenthestoveandthe
openfire.
Ifthereisnoexistingchimneytheneitheraprefabricatedblockchimney,inaccordance
withBuildingRegulationsApprovedDocumentJoratwinwallinsulatedstainlesssteel
fluetoBS4543canbeused.Thesechimneysmustbefittedinaccordancewiththe
manufacturer’sinstructionsandtheBuildingRegulations.
Asinglewallmetalfluepipeissuitableforconnectingthestovetothechimneybutis
notsuitableforusingforthecompletechimney.Thechimneyand
connectingfluepipemusthaveaminimumdiameterof150mmandit’s
dimensionshouldbenotlessthanthesizeoftheoutletsocketofthestovewhichis
150mm.Anybendinthechimneyorconnectingfluepipeshouldnotexceed45°.90°
bendsshouldnotbeused.
Combustiblematerialshouldnotbelocatedwheretheheatdissipatingthroughthe
wallsoffireplacesorfluescouldigniteit.Thereforewheninstallingthestoveinthe
presenceofcombustiblematerialsdueaccountmustbetakenofthe
guidanceontheseparationofcombustiblemateri algiveninBuildingRegulationsAp
provedDocumentJandalsointhesestoveinstructions.
ENGLISH RAISmanualforRaisTopasandRaisOpus
9
Ifitisfoundthatthereisexcessivedraughtinthechimneytheneitheran
adjustablefluedamperoralternativelyadraughtstabilisershouldbefitted.The
adjustablefluedampershouldnotcloseofftheflueentirely,butshouldinits
closedpositionleaveaminimumcontinuousopeningfreeareaofatleast20%
ofthetotalcrosssectionalareaoftheflueorfluepipe.
Adequateprovisione.g.easilyaccessiblesootdoorordoorsmustbeprovided
forsweepingthechimneyandconnectingfluepipe.
Youshouldalsofamiliariseyourselfwiththedraughtconditionsforchimneys
with2flues.
Forstrongdraughts,thechimneyorflueshouldbefittedwithadraught
stabiliser.Inwhichcase,itisimportanttoensurethatthereisafreeflowthrough
areaofminimum20cm
2
whentheregulatinggateisshut.Otherwise,thefuel
energymaynotbeusedoptimally.
If,atanytime,youareunsureabouttheconditionofthechimney,youshould
contactachimneysweep.
Rememberthataccesstothesootdoorshouldbekeptclear.
ENGLISH RAISmanualforRaisTopasandRaisOpus
10
Installation
Itisprohibitedtocarryoutunauthorisedalterationstothestove.
Theremustbeplentyoffreshairintheroomwherethestoveisbeinginstalled,inorderto
ensurepropercombustion.Notethatanymechanicalexhaustventilatione.g.an
extractionhoodmayreducetheairsupply.Anyairgrillesmustbeplacedinsucha
manner,thattheairsupplyisnotblocked.
Thestoveisequippedwithfourconvectionairoutlets,whichmaybeconnectedwith
suitableairductstootherrooms.
BuildingRegulationsApprovedDocumentJgivesspecificguidanceontherequired
permanentventilationintotheroomforcombustionairofsol idfuelappliances.
Thefloorstructuremustbeabletocarrytheweightofthewoodburningstove,aswellas
theweightofachimney,ifnecessary.
WhenyouchoosewheretosetupyourRAISwoodburningstove,youshouldconsiderthe
heatdistributiontotheotherrooms.Thiswillenableyoutogetthebestuseoutofyour
stove.
Thestoveshouldbesetupatasafedistancefrominflammablematerials.
Seethemanufacturer'splateonthewoodburningstove.
ENGLISH RAISmanualforRaisTopasandRaisOpus
11
Installationwithturntable
Ifthestovehasaturntablethenpleasedothefollowing:
Pushthefootpedal/releasearmbackwards,afterwhichthestoveisturnedat15°
intervals.Whenthestoveisinthedesiredposition,letgoofthepedalandturnthestove
lightlyuntilitslipsintoplace.
ENGLISH RAISmanualforRaisTopasandRaisOpus
12
Changeofchimneyconnection
Thestoveisdeliveredreadyfortopoutlet,butitcanbechangedtorearoutletinthe
followingway:
Removethebaffleplateandsmokediverter(seecleaningandcare).
Liftupthereflectorplate,pushoutthe‘knockout’and
putthereflectorplatebackintoplace.
Removethecasingknockout.
ENGLISH RAISmanualforRaisTopasandRaisOpus
13
LoosenthethreeM6nutswithaspanner.
Liftthebackpaneloffthebaseplateandremovethe
knockoutplateinthebackpanel(seeprevious
page)aswellasthereflectorplate.
Itmaybeadvantageoustoloosenthefournutsand
takeoutthereflectorplatebeforeremovingthe
knockoutplateontotheaboveplates.
ENGLISH RAISmanualforRaisTopasandRaisOpus
14
Removetheprotectivecover/sealandplaceoverthe
holeinthetopmakesurethatthesealispositioned
properly.TightentheassemblyusingthethreeM6nuts.
Theflueoutletspigot,whichcanbefoundinthestoveina
bag,andtheholderfortheupperfluediverterare
assembledwith3M6x20nutsandbolts.
Theupperfluediverter,baffleplateandtopplateare
assembledinreverseorder.
ENGLISH RAISmanualforRaisTopasandRaisOpus
15
Installationdistanceincaseofcombustiblewall
Tofindoutwhetherthewallnexttowherethestoveisgoingtobeinstalledisflammable,
youshouldcontactyourbuildingcontractororthelocalbuildingauthorities.
Thehearthshouldbeabletoaccommodatethewei ghtofthestove.Thechimneymustbe
independentlysupportedbywallbracketsoraceilingsupportplate.Theweightofthestove
isindicatedinthebrochure.
Thestoveshouldalwaysbeinstalledonanoncombustiblehearthofasizeandconstruction
thatisinaccordancewiththeprovisionsofthecurrentUKBuildi ngRegulationsApproved
DocumentJ.
Ifthestoveistobeinstalledonawoodenfloor,itmustbecoveredwithanoncombustible
materialatleast12mmthick,inaccordancewithUKBuildingRegulationsApproved
DocumentJ,toadistanceof300mminfrontofthestoveand150mmtoeachside
measuringfromthedoorofthecombustionchamber.
Theclearancedistancestocombustiblematerialbeneath,surroundingoruponthehearth
andwallsadjacenttothehearthshouldcompl ywiththeguidanceontheseparationof
combustiblematerialgiveninUKBuildingRegulationsApprovedDoc umentJandalsoin
thesestoveinstructions.
ENGLISH RAISmanualforRaisTopasandRaisOpus
16
350mm
ENGLISH RAISmanualforRaisTopasandRaisOpus
17
Usinguninsulatedfluepipe,theminimumdistancetoacombustiblewallmustbe450mmor
225mmifthewallisheatshielded(seeSectionJoftheBuildingRegulations)fromtheflue
pipe.
ENGLISH RAISmanualforRaisTopasandRaisOpus
18
FortheInstaller
Finallybeforefiringthestoveforthefirsttimeacheckshouldbemadetoensurethatthe
assemblyandstoveinstallationhasbeensatisfactoryandthattherearenoleaksinany
sealsintheapplianceandapplianceconnecti onstothechimney.
Ensurethattheapplianceandchimneyfluearefunctioningcorrectlybeforefinally
handingovertotheuser.Readthelaterpartsofthismanualforguidanceoncare
requiredwhenfirstlighting.
Informtheuserthattheappliancehasbeencommissionedandreadytouseandgive
instructiononthesafeoperationofthestove.
TheseInstructionsmustbeleftwiththeuserandtheusershouldbeinstructedtokeep
theminasafeplace.
ENGLISH RAISmanualforRaisTopasandRaisOpus
19
ONLYUSERECOMMENDEDFUELS
Thefollowingtableshowsthecalorificvalueofdifferenttypesofwood,whichhavebeen
storedfor2yearsandwhichhavearesidualmoistureof15 17%.
Wood Kgdrywoodprm
3
comparedtobeech/oak
Hornbeam 640 110%
Beechandoak 580 100%
Ash 570 98%
Maple 540 93%
Birch 510 88%
Mountainpine 480 83%
Fir 390 67%
Poplar 380 65%
1kgofwoodyieldsthesameheatenergyirrespectiveofwoodtype.
1kgofbeechmerelytakesuplessspacethan1kgoffir.
Operatinginstructions
PleasenotethatHETASApplianceApprovalonlycoverstheuseofdryseasonedwood
logsonthisappliance.HETASApprovaldoesnotcovertheuseofotherfuelseither
aloneormixedwiththewoodlogs,nordoesitcoverinstructio nsfortheuseofother
fuels.
Fuel
ThestoveisdesignedandapprovedinaccordancewithEN13240andNS3058for
stokingsplit,driedfirewood.Thefirewoodmusthaveawatercontentof1522%andits
max.lengthshouldbethelengthofthecombustionchamberminus5060mm.
Stokingwithwetfirewoodcausesbothsoot,environmentalpollutionandbadfuel
economy.Freshlycutwoodcontainsapprox.5070%waterandisthoroughlyunsuitable
forstoking.Allowatleast1yearofstoragetimefornewlycutwoodbeforeusing.Wood
withadiameterofmorethan100mmshouldbesplit.Regardlessofwoodsize,itshould
alwayshaveatleastonesurfaceareafreeofbark.
Wedonotrecommendstokingwithpainted,lami natedorimpregnatedwood,woodwith
asyntheticsurface,paintedrefusewood,chipboard,plywood,domesticwaste,paper
briquettesandpitcoal,asthiswillproducemalodoroussmoke,whichcouldbe
poisonous.
Whenfiringwiththeabovementioneditemsandamountslargerthanthose
recommended,thestoveissubjectedtoalargeramountofheat,whichresultsina
higherchimneytemperatureandlowerefficiency.Thiscanresultinthestoveand
chimneybecomingdamagedandwouldvoidthewarranty.
Thecalorificvalueofthefirewoodiscloselyconnectedtothemoisturelevel.
Moistfirewoodhasalowheatvalue.Themorewaterthewoodcontains,themore
energyittakesforthiswatertovaporise,resultinginthisenergybeinglost.
ENGLISH RAISmanualforRaisTopasandRaisOpus
20
Dryingandstorage
Dryingwoodtakestime:properairdryingtakesapproximately2years.
Herearesometips:
Storethewoodsawn,splitandstackedinanairy,sunnyplace,whichisprotectedagainst
rain(thesouthsideofthehouseisparticularlysuitable).
Storethefirewoodstacksatahand'sbreadthapart,asthisensuresthattheairflowing
throughtakesthemoisturewithit.Avoidcoveringthefirewoodstackswithplastic,asthis
preventsthemoisturefromescaping.Itisagoodideatobringthefirewoodintothehouse
23daysbeforeyouneedit.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34

RAIS AVANT Manual Manual

Category
Wood stove
Type
Manual Manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI