Skov Replacement of panel Technical User Guide

Type
Technical User Guide
Replacement of 10" Panel
without CPU Module
Technical User Guide
604335 • 2020-12-03
Replacement of 10" Panel without CPU Module
2 Technical User Guide
1 Product description
This is a 10” panel without CPU module for a controller.
(G)
(F)
(F) (G)
Replacement of 10" Panel without CPU Module
Technical User Guide 3
2 Mounting guide
2.1 Electrical connection
Installation, servicing and troubleshooting of all electrical equipment must be carried out by quali-
fied personnel in compliance with the applicable national and international standard EN 60204-1
and any other EU standards that are applicable in Europe.
The installation of a power supply isolator is required for each motor and power supply to facilitate
voltage-free work on the electrical equipment. The power supply isolator is not included.
2.2 Replacement of 10” panel without CPU module
Dismantling the 10” panel without CPU module
1. Disconnect the power to the controller.
2. Remove the front panel screws (A) to release the panel.
3. Disconnect the network connector on the CPU module (C), if the controller is part of a network.
4. Disconnect the flat cable (B) from the main module (H).
5. Click off the protective cap (D) to release it from the CPU module (C); use a screwdriver as shown in picture
(E).
6. Click off the CPU module (C) as shown in the picture below. Click off the CPU module in the side with the
network connector (LAN). Carefully tilt it up and turn it upside down.
7. Disconnect the LVDS flat cable (F) and touch flat cable (G) (press the connectors on the flat cables up in
both sides).
Mounting of 10” panel without CPU module
1. Connect the LVDS flat cable (F) and touch flat cable (G) on the the new CPU module (press the connectors
on the flat cables down in both sides).
2. Mount the CPU module (C) on the new panel.
3. Mount the protective cap (D) on the CPU module (C).
4. Reconnect the flat cable (B) on the main module (H).
5. Connect the network connector on the CPU module (C), if the controller is part of a network.
6. Mount the new panel on the cabinet using the front panel screws (A).
7. Power the controller.
604335 • 2020-12-03 • en-US • Made in Denmark
SKOV A/S • Hedelund 4 • Glyngøre • DK-7870 Roslev
Tel. +45 72 17 55 55 • www.skov.com • E-mail: [email protected]