Leviton ODS10-IQE Installation guide

Category
Motion detectors
Type
Installation guide

This manual is also suitable for

Leviton ODS10-IQE is a designer wall switch occupancy sensor that can automatically switch your lights on and off based on motion detection. It's a self-contained device that provides sensing and light control, and it can be used with incandescent, fluorescent, and magnetic low-voltage ballasts, as well as electronic and magnetic ballasts. The ODS10-IQE has a range of up to 2100 square feet and a time-out delay of up to 30 minutes. It also features an ambient light override that allows you to set the light level at which the sensor will turn the lights on.

Leviton ODS10-IQE is a designer wall switch occupancy sensor that can automatically switch your lights on and off based on motion detection. It's a self-contained device that provides sensing and light control, and it can be used with incandescent, fluorescent, and magnetic low-voltage ballasts, as well as electronic and magnetic ballasts. The ODS10-IQE has a range of up to 2100 square feet and a time-out delay of up to 30 minutes. It also features an ambient light override that allows you to set the light level at which the sensor will turn the lights on.

WARNINGS AND CAUTIONS:
• TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT THE POWER IS OFF BEFORE WIRING!
• DO NOTcontrolaloadinexcessofthespeciedratings.Damagetotheunit,re,electricshock,personalinjuryordeathcanoccur.
Checkyourloadratingstodeterminesuitabilityforyourapplication.
• Tobeinstalledand/orusedinaccordancewithelectricalcodesandregulations.
• Ifyouarenotsureaboutanypartoftheseinstructions,consultanelectrician.
WARNINGS AND CAUTIONS:
• Donotinstallthisunittocontrolareceptacle.
• Donottouchthesurfaceofthelens.Cleanoutersurfacewithadampclothonly.
• TheCat.No.ODS10-IQoccupancysensorisintendedtoreplaceastandardlightswitch.
• UsethisdeviceONLY WITH COPPER OR COPPER CLAD WIRE.
SinglePole(OneLocation)orMulti-Location
Designer Wall Switch Occupancy Sensor
Cat. No. ODS10-IQ
Incandescent - 800W-6.67A@120V-Fluorescent -1200VA-10A@120V-Fluorescent -2700VA-10A@277V-Supplemental - 1/4hp-5.8A@120V
No Minimum Load Required
Compatiblewithelectronicandmagneticballasts,electronicandmagneticlow-voltageballasts,incandescentlamps,andfans.
INSTALLATION INSTRUCTIONS
TOOLS NEEDED TO INSTALL YOUR SENSOR
Slotted/PhillipsScrewdriver ElectricalTape Pliers
Cutters SmallSlottedScrewdriver
LevitonCat.No.ODS10-IQ,DesignerWallSwitchOccupancySensor,
isdesignedtodetectmotionfromaheat-emittingsource(suchas
apersonenteringaroom)withinitseld-of-view(monitoredspace)
andautomaticallyswitchlightsONandOFF.Thecontrolledlightswill
remainONuntilnomotionisdetectedandthescheduledtime-delay
hasexpired.
Cat. No. ODS10-IQ is UL and cUL listed.
TheOccupancySensorsensesmotionwithinitscoverageareaof
2100sq.ft(195.1m
2
)maximumandcontrolstheconnectedlighting.
Thisisaself-containeddevicewhichprovidessensingandlight
control.TheOccupancySensorwillturnthelightsONwhenmotion
isinitiallydetected,andkeepthelightsONforaslongasmotionis
detected.
TheOccupancySensorusesasmallsemiconductorheatdetectorthat
residesbehindamulti-zoneopticallens.ThisFresnellensestablishes
dozensofzonesofdetection.Thesensorissensitivetotheheat
emittedbythehumanbody.Inordertotriggerthesensor,thesource
ofheatmustmovefromonezoneofdetectiontoanother.Thedevice
ismosteffectiveinsensingmotionacrossitseld-of-view,andless
effectivesensingmotiontowardsorawayfromitseld-of-view(refer
to Field-of-View diagrams).Keepthisinmindwhenselectingthe
installationlocation(refer to Field-of-View diagrams).
Notethatoccupancysensorsrespondtorapidchangesin
temperature,socareshouldbetakennottomountthedevice
nearaclimatecontrolsource(i.e.radiators,airexchanges,andair
conditioners).Hotorcolddraftswilllooklikebodymotiontothedevice
andwilltriggeritiftheunitismountedtooclose.It is recommended
to mount the Occupancy Sensor at least 6 ft. away from then
climate control source.Thedevicecanbemountedinasinglegang
wallbox.
Inaddition,itisalsorecommendedNOTtomounttheOccupancy
Sensordirectlyunderalargelightsource.Largewattagebulbs
(greaterthan100Wincandescent)giveoffalotofheatandswitching
thebulbcausesatemperaturechangethatcanbedetectedbythe
device.MounttheOccupancySensoratleast6ft.awayfromlarge
bulbs.Ifitnecessarytomountthedevicecloser,lowerthewattageof
thebulbdirectlyoverhead.
WARNING:TO AVOID FIRE, SHOCK, OR DEATH; TURN
OFF POWER atcircuitbreakerorfuseandtestthatpoweris
offbeforewiring!
Step 1
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFFONOFF
ONOFF
ONOFF
ONOFF
ONOFF
• Pulloffpre-cutinsulationfromsensorleads.
• Makesurethattheendsofthewiresfromthewallboxarestraight
(cut if necessary).
• Removeinsulationfromeachwireinthewallboxasshown.
Preparing and connecting wires:
9/16"
(1.4 cm)
Strip Gage
(measure bare
wire here)
Cut
(if necessary)
Step 3
INSTALLING YOUR SENSOR
NOTE:UsecheckboxeswhenStepsarecompleted.
Installing your Sensor – Single-Pole Application:
Step 4
Identifying your wiring application
(most common):
Step 2
WIRING SENSOR:
Connect wires per WIRING DIAGRAM as follows:Screwwireconnector
onclockwisemakingsuretherearenobareconductorsbelowthewire
connectors.Secureeachconnectorwithelectricaltape.
• GreenorbarecopperwireinwallboxtoGreenlead.
• LineHotwallboxwiretoBlacklead.
• LoadwallboxwiretoBluelead.
NOTE: Allow 1 minute for warm-up after connecting and energizing.
WIRING SENSOR 1:
Connect wires per WIRING DIAGRAM as follows:
• GreenorbarecopperwireinwallboxtoSensor1Greenlead.
• LineHot(common)wallboxwireidentied(tagged)whenremovingold
switchandFirsttravelerfromSensor2toSensor1Blacklead.
• SecondTravelerwallboxwirefromSensor2toSensor1Bluelead.
WIRING SENSOR 2:
Connect wires per WIRING DIAGRAM as follows:
• GreenorbarecopperwireinwallboxtoSensor2Greenlead.
• Loadwallboxwireidentied(tagged)whenremovingoldswitchand
SecondTravelerfromSensor1toSensor2Bluelead.
• FirstTravelerLineHotfromSensor1toSensor2Blacklead.
NOTE: Allow 1 minute for warm-up after connecting and energizing.
NOTE: TheCat.No.ODS10-IQrequiresagroundwiretooperate
properly.Ifthereisnogroundwire,ensureelectricalboxisgroundedand
attachgroundwiretoboxwithascrew.Ifthegroundwireisoatingthis
devicewillnotwork.
NOTE: TheCat.No.ODS10-IQrequiresagroundwiretooperate
properly.Ifthereisnogroundwire,ensureelectricalboxisgroundedand
attachgroundwiretoboxwithascrew.Ifthegroundwireisoatingthis
devicewillnotwork.
NOTE:EithersensorcanturnthelightsON.Bothsensorsmusttimeout
toOFF.
DESCRIPTION
DI-02X-ODS10-00A
• AutoON/AutoOFF
• Leviton’sDecora
®
styledesign
• Switcheselectronicballasts
• LowProle,tamper-resistantlens
• AmbientLightOverride
FEATURES
3-Way
1. LineorLoad(Seeimportant*instruction)
2. Ground
3. FirstTraveler–notecolor
4. SecondTraveler–notecolor
Single-Pole
1.Line(Hot)
2.Ground
3.Load
IMPORTANT:For3-Wayapplications,notethatoneofthescrew
terminalsfromtheoldswitchbeingremovedwillusuallybeadifferent
color(Black)orlabeledCommon.Tagthatwirewithelectricaltapeand
identifyasthecommon(LineorLoad)inbothswitchwallboxes.
Step 5
Installing your Sensor – 3-Way Wiring Application:
NOTE:Dresswireswithabendtorelievestresswhenmounting
device.
Positionallwirestoprovideroominoutletwallboxfordevice.
• Partiallysecuredeviceusinglongmountingscrewsprovided.
• Restorepoweratcircuitbreakerorfuse.
NOTE:ToavoidPERMANENTDAMAGEtotheunit,becareful
NOTTOOVERTURNthecontrolknobsorleverswhensettingthe
Sensor.Thecontrolscanbeaccessedbyremovingthewallplate
(ifapplicable)andcontrolpanelcover(refer to Control Panel
Diagram).Useasmallstraightbladescrewdrivertoadjustknobs
andandangertoadjusttheblinderlevers.
NOTE: DO NOT pressinonblinderleversoruseexcessiveforce
(refer to Control Panel Diagram).
• AttachtheControlPanelcoverwhenthedesiredsettingsare
complete.
If lights do not turn ON, refer to the TROUBLESHOOTING section.
Testing your Sensor prior to completely
mounting in wall box:
Step 6
Device Mounting:
TURN OFF POWER AT CIRCUIT
BREAKER OR FUSE.
Step 7
Restore Power:
Restorepoweratcircuitbreakerorfuse.
Installation is complete.
LeavetheroomandthelightswillturnOFFafterthe
selectedtime-outexpires.
Step 8
Installationmaynowbecompletedbytightening
mountingscrewsintowallbox.Attachwallplate.
Hot (Black)
Neutral (White)
Load
Sensor
Black
Black
White
Blue
Green
Ground
Line
120-277VAC
50/60 Hz
Hot
(Black)
Neutral (White)
Load
Blue
Blue
Black
Green
Ground
Black
White
Black
Line
120-277VAC
50/60 Hz
Green
Ground
Sensor 2
Sensor 1
2
1
3
4
1
3
2
AutoON/AutoOFF:ThisdeviceisfactorysettooperateinAutoON/Auto
OFFmode.Thepushbuttonhasbeendisabledtopreventtheuserfrom
manuallycontrollingthelights.InAutoON/AutoOFFmodethelightswill
automaticallyturnONwhenmotionisdetected.Intheabsenceofmotion,
afterthetimeoutexpires,thelightswillturnOFF.
SETTINGS
OPERATION
• Fortechnicalassistancecontactusat1-800-824-3005
• Visitourwebsiteatwww.leviton.com
PRODUCT INFORMATION
DI-02X-ODS10-00A
©2012LevitonMfg.Co.,Inc.
Control Panel Cover
Blinder
Adjustment
Levers
BLINDERS
Range
Light
Time
12
3
4
7
10
4
7
10
Slash Mark
Control Panel Diagram
FCC COMPLIANCE STATEMENT
ThisdevicecomplieswithPart15oftheFCCRules.Operationissubjecttofollowing
twoconditions:(1)thisdevicemaynotcauseharmfulinterference,and(2)this
devicemustacceptanyinterferencereceived,includinginterferencethatmaycause
undesiredoperationofthedevice.
ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassB
DigitalDevice,pursuanttoPart15oftheFCCRules.Theselimitsaredesigned
toprovidereasonableprotectionagainstharmfulinterferenceinaresidential
installation.Thisequipmentgenerates,uses,andcanradiateradiofrequency
energyand,ifnotinstalledandusedinaccordancewiththeinstructions,maycause
harmfulinterferencetoradiocommunications.However,thereisnoguaranteethat
interferencewillnotoccurinaparticularinstallation.Ifthisequipmentdoescause
harmfulinterferencetoradioortelevisionreception,whichcanbedeterminedby
turningtheequipmentOFFandON,theuserisencouragedtotrytocorrectthe
interferencebyoneormoreofthefollowingmeasures:
• ReorientorrelocatethereceivingAntenna.
• Increasetheseparationbetweentheequipmentandthereceiver.
• Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthe
receiverisconnected.
• Consultthedealeroranexperiencedradio/tvtechnicianforhelp.
FCC CAUTION
AnychangesormodicationsnotexpresslyapprovedbyLevitonManufacturingCo.,
Inc.,couldvoidtheuser'sauthoritytooperatetheequipment.
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
LevitonwarrantstotheoriginalconsumerpurchaserandnotforthebenetofanyoneelsethatthisproductatthetimeofitssalebyLevitonisfreeofdefectsinmaterialsandworkmanshipundernormalandproperuseforveyearsfromthepurchasedate.Leviton’sonlyobligationistocorrectsuchdefectsbyrepairorreplacement,atitsoption,ifwithinsuchveyearperiodtheproductisreturnedprepaid,with
proofofpurchasedate,andadescriptionoftheproblemtoLeviton Manufacturing Co., Inc., Att: Quality Assurance Department, 201 North Service Road, Melville, New York 11747.Thiswarrantyexcludesandthereisdisclaimedliabilityforlaborforremovalofthisproductorreinstallation.Thiswarrantyisvoidifthisproductisinstalledimproperlyorinanimproperenvironment,overloaded,misused,opened,
abused,oralteredinanymanner,orisnotusedundernormaloperatingconditionsornotinaccordancewithanylabelsorinstructions.There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose,butifanyimpliedwarrantyisrequiredbytheapplicablejurisdiction,thedurationofanysuchimpliedwarranty,includingmerchantabilityandtnessfor
aparticularpurpose,islimitedtoveyears.Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation.Theremediesprovidedhereinaretheexclusiveremediesunderthiswarranty,whetherbasedoncontract,tortorotherwise.
TROUBLESHOOTING
1. Ifthereisnoresponsefromtheunit(thelightneverturnsONandthe
LEDneverblinks)11/2minutesafterpowerisapplied,thenuninstall
deviceandverifythereisagroundconnectionatthewallbox.Ifthere
isagroundconnection,verifywiring.
2. IfthelightsneverturnON,buttheLEDblinks,checkiftheAmbient
LightControlKnobispointedfullycounter-clockwise(CCW).Rotateit
clockwise(CW)untilthelightsturnON.
3. IfthelightsconstantlystayON,evenwhentheroomisunoccupied:
A.ChecktheTimesetting.Seehowthistimecomparestohowlong
thelightsstayON.
B.TryloweringtheRangeControl.RotatetheknobCCWabout30˚.
C.Iftheproblempersists,tryreducingagain.Note:DoNotreduceso
muchthatCat.No.ODS10-IQcannotseenormaloccupancy.
D.BesuretousetheBlinderstoblockanyunwantedhallwaytrafc.
E.Checkforreectedheat/motionasSensorUnitmaybeseeing
motionthroughawindow.
F.CheckforadjacentHVACand/orheaterducts.
4. ForadditionalinformationcallLeviton’sTechnicalSupportLine.
Side (Vertical) Field - of - View
27 ft.
(8.2 m)
38 ft.
(11.7 m)
4 ft.
(1.2 m)
4.5 ft.
(1.4 m)
1
0
8.3
0
Sensor Unit
Field - of - View (Horizontal)
60 ft. (18.3 m)
40 ft. (12.2 m)
30 ft. (9.1 m)
20 ft. (6.1 m)
BLINDERS:Theblinderscannarrowtheeld-of-viewofthedeviceto
preventunwantedactivationfromtrafcinadjacentspace.Thereare
twoblinders,andeachoperateindependently.Tooperatetheblinders,
useangerorsmallscrewdrivertomovetheblinderadjustmentlevers
towardorawayfromthecenterofthedevice.
Theblinderleversarefoundabovethecontrolknobsandbelowthetext
‘BLINDERS’onthecontrolpanel.Withbothleversmovedfullytowards
thecenter,theeld-of-viewisnarrowedto60°.Withbothleversmoved
fullyawayfromthecenter,theeld-of-viewisatamaximum180°(refer
to Control Panel Diagram
).
TIME-DELAY:Cat.No.ODS10-IQwillturnlightsONwhenmotionis
detected.Whenmotionisnolongerdetected,theSensorUnitwillwait
acertainamountoftimeandthenturnthelightsOFF.Thiswaittimeis
called‘time-out’.
The“time-out”isselectedfromfour(4)presetvalues.Pointingthe
arrowatoneofthemarkingsonthefacechoosesthevalueoftime.The
followingselectionsareavailable:
Face Marking Value of Time
(/)SlashMark 30secondxedtime-outusedforperforminga
walk-test.
1 10minutetime-out
2 20minutetime-out
3 30minutetime-out
The “time-out” is factory preset to ten (10) minutes. Refer to figure 2A.
NOTE:Alltimedurationsmentionedintheinstructionsareapproximate
within10seconds.
AMBIENT LIGHT: TheAmbientLightLevelistheamountoflight
presentinaroomwithoutanyarticiallightadded.Ifthereisalready
enoughlightinaroom,theoccupantmaynotneedfurtherarticiallight.
Cat.No.ODS10-IQhasanadjustmenttokeepthelightsfromturning
ONifthereisenoughlightalreadypresent. The adjustment should be
made when the ambient light is at the level where artificial light is
needed.Followthesestepstomakeamoreaccurateadjustmentofthe
LightControl.
FEATURES
1.WiththelightsON,rotatetheTimeControlfullycounter-clockwise
(CCW)tosetthetime-outtothethirty(30)secondtestmode(refer
to Control Panel Diagram
).
2.RotatetheLightControlfullyCCW.
3.CovertheSensorUnitwithanopaquematerial,orleavetheroom
andlettheSensorUnittime-outandturnthelightsOFF.
4.RotatetheLightControlclockwise(CW)slowly,untilthelightturns
ON.Thisisthesettingforthecurrentleveloflightintheroom.
5.Adjustmentsarenished.
Manual ON Mode (N/A on this sensor):Themanualoverridebutton
onthesensorhasbeendeactivatedandwillnotcontrolthelights.
IfthelightcontrolisinthefullyCWposition,thelightswillturnON
whenevermotionisdetected,eveninfulldaylight.Intermediate
settingswillcausethelightstoturnONonlywhentheambientlightis
belowthelevelselectedbythelightcontrol.
NOTE:WhenthesettingisattheminimumCCWlevel,thelightswill
stayOFFwhentheroomisdim.Whenthesettingisatthemaximum
levelclockwise(CW),thelightswillturnONwhentheroomisbright.
NOTE:Theambientlightinaroomwillchangewiththetimeofday
andtheseasonoftheyear.
RANGE:Todecreasedetectionrangeandsensitivity,rotatetheknob
CCW(refer
to Control Panel Diagram
).Thedetectionrangecanbe
adjustedfrom100%downto36%.
Control Panel
Cover
Push Button
(Disabled)
Lens
Mounting Yoke
LED
Window
Bottom
Blinders
  • Page 1 1
  • Page 2 2

Leviton ODS10-IQE Installation guide

Category
Motion detectors
Type
Installation guide
This manual is also suitable for

Leviton ODS10-IQE is a designer wall switch occupancy sensor that can automatically switch your lights on and off based on motion detection. It's a self-contained device that provides sensing and light control, and it can be used with incandescent, fluorescent, and magnetic low-voltage ballasts, as well as electronic and magnetic ballasts. The ODS10-IQE has a range of up to 2100 square feet and a time-out delay of up to 30 minutes. It also features an ambient light override that allows you to set the light level at which the sensor will turn the lights on.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI