  • Hello! I am an AI chatbot trained to assist you with the Danfoss SpeedUp Eco - Strongboard tile and laminate User guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Application sheet
SpeedUp Eco
Laminate
Strongboard tile and laminate
1
2
3
4
5
1 Laminate ≥ 8 mm
2 Strongboard tile and laminate 5 mm
3 SpeedUp Eco heat panel + FH composite pipe 30 mm
4 Support batten (30mm)
5 SpeedUp Eco perimeter insulation
6 If necessary moisture barrier
Floor nish ≥ 8 mm Laminate; strength without subsonic noise lamination
Construction height ≥ 43 mm Height including oor nish
Weight ~ 15 kg / m² Weight including oor nish
Thermal resistance R 0,75 m²K / W The minimum thermal resistance requirement of EnEV is fullled.
Thermal transmission coecient U 1,09 W / m²K
Design load ≤ 2,0 kN / m²
Point load (≥ 20 cm²) ≤ 2,0 kN Sum point load ≤ design load; please notice special heavy ob-
jects (aquaria etc.)
Impact subsonic noise reduction 19 dB Test value according to DIN ISO 140-8; applies to concrete slabs
thicker than 12 cm (DIN 4109: m’ > 276 kg/m²)
Application area
Residential spaces, hallways and attic spaces in residential buildings and hotel rooms.
Corresponds to categories A1, A2 and A3 of DIN 1055-3. Oce spaces, hallways in oce
buildings, medical oces, stations and spaces with human occupancy, and commercial
spaces with oor areas up to 50 m² in residential or oce buildings. Corresponds to
categories B1, D1 and D2 of DIN 1055-3.
Requirements & special features
A level, smooth and structurally sound surface is necessary for full surface contact with
the heating elements (elevated requirements according to DIN 18202 Table 3, row 4).
Strongboard is used under the laminate as a structural and subsonic noise reduction
layer. Protect laminate against moisture penetration from below if necessary (vapour
barrier). Observe all installation instructions and manufacturer’s instructions.
Additional insulation
This construction is suitable for oors between rooms of equal temperature. No ad-
ditional insulation necessary. Permitted compensating insulation, see Max. Additional
Insulation summary.
Construction
According to EnEV, EN 1264, DIN 1055, 4108 and 18202
Construction number 33
Technical Data Floors/ceilings between rooms at the same temperature
6
© Danfoss 11/2008
VA.CS.E1.02