  • Hello! I am an AI chatbot trained to assist you with the CalAmp Viper SC+ Base Station Quick start guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
ViperSC+BaseStationOrderNumbers
US&Canada
TheViperSC+BaseStationforuseintheUSandCanadaisavailableas:
StandardBaseStation
RedundantBaseStationor
RedundantBaseStationwithDualRFPort(RedundantBase‐DualRF)
1405118502VHF136174MHZ6.2550kHzBW
ViperSC+StandardBaseStation
1405318502VHF136174MHZ6.2550kHzBWViperSC+RedundantBaseStation
1405318503VHF136174MHZ6.2550kHzBWViperSC+RedundantBase‐DualRF
1405128504VHF215240MHZ6.25100kHzBWViperSC+
StandardBaseStation
1405328504VHF215240MHZ6.25100kHzBWViperSC+RedundantBaseStation
1405328505VHF215240MHZ6.25100kHzBWViperSC+RedundantBase‐DualRF
1405148302UHF406.1125470MHZ6.2550kHzBWViperSC+Standard
BaseStation
1405348302UHF406.1125470MHZ6.2550kHzBWViperSC+RedundantBaseStation
1405348303UHF406.1125470MHZ6.2550kHzBWViperSC+RedundantBase‐DualRF
1405148502UHF450512MHZ6.2550kHzBWViperSC+StandardBaseStation
1405348502UHF450512MHZ6.2550kHzBWViperSC+RedundantBaseStation
1405348503UHF450512MHZ6.2550kHzBWViperSC+RedundantBase‐DualRF
1405198304UHF880902MHZ12.5100kHzBWViperSC+StandardBaseStation
140
5398304900880902MHZ12.5100kHzBWViperSC+RedundantBaseStation
1405398305900880902MHZ12.5100kHzBWViperSC+RedundantBase‐DualRF
1405198504900928960MHZ12.5100kHzBWViperSC+StandardBaseStation
1405398504
900928960MHZ12.5100kHzBWViperSC+RedundantBaseStation
1405398505900928960MHZ12.5100kHzBWViperSC+RedundantBase‐DualRF
ETSI/AS/NZCompliant
TheViperSC+BaseStationforuseintheEuropeanUnion(ETSI),Australia(AS),andNew
Zealand(NZ)
isavailableas:
StandardBaseStation
StandardBaseStationwithDualRFPort(StandardBase‐DualRF)
RedundantBaseStationor
RedundantBaseStationwithDualRFPort(RedundantBase‐DualRF)
(AllunitsETSI/AS/NZ)
1405118600VHF142174MHZ12.525kHzBWViper
SC+StandardBaseStation
1405118601VHF142174MHZ12.525kHzBWViperSC+StandardBase‐DualRF
1405318600VHF142174MHZ12.525kHzBWViperSC+RedundantBaseStation
1405318601VHF142174MHZ12.525kHzBWViperSC+
RedundantBase‐DualRF
1405148400UHF406.1125470MHZ12.525kHzBWViperSC+StandardBaseStation
1405148401UHF406.1125470MHZ12.525kHzBWViperSC+StandardBase‐DualRF
1405348400UHF406.1125470MHZ12.525kHzBWViperSC+BW
RedundantBase
1405348401UHF406.1125470MHZ12.525kHzBWViperSC+RedundantBase‐DualRF
1405148600UHF450512MHZ12.525kHzBWViperSC+StandardBaseStation
1405148601UHF450512MHZ12.525kHzBWViperSC+StandardBase‐
DualRF
1405348600UHF450512MHZ12.525kHzBWViperSC+RedundantBaseStation
1405348601UHF450512MHZ12.525kHzBWViperSC+RedundantBase‐DualRF
PackageContents
YourViperSC+BaseStationpackagecontains:
(1)ViperSC+BaseStation(Configuredasperpartnumberabove)
(1)60in.CAT5EthernetCable
(1)PowerCable
(1)StartUpCDROMandProductDocumentationCard
Anychangesormodificationsnotexpresslyapprovedbythepartyresponsibleforcompliance(inthecountry
whereused)couldvoidtheuser’sauthoritytooperatetheequipment.
CalAmpreservestherighttoupdateitsproducts,software,ordocumentationwithoutobligationtonotifyany
individualorentity.Productupdatesmayresultin
differencesbetweentheinformationprovidedandthe
productshipped.Foraccesstothemostcurrentproductdocumentationandapplicationnotes,visittheSupport
sectionofourwebsite.
KitComponents
Description Item
BasicUnit
ViperSC+IPRouter
60in.Cat5Ethernet
Cable
PowerCable
2‐and3PieceKitAdditionalItems
SMAMaletoBNC
FemaleConnector
SMAFemaletoBNC
MaleConnector
TNCMaletoBNC
FemaleConnector
MiniCircuits5W20
dBAttenuator
FlexRubberDuck
Antenna
(VHF,UHF,or900
MHz)
120VACto13.8VDC
4APowerSupply
Product
Documentation
http://www.calamp.com/help/devicefirmware/desktop/Viper_SC_Firmware_Files_and_Instructions.htm
1401NorthRiceAvenue
Oxnard,CA93030
Tel:1.805.987.9000
Fax:1.805.987.8359.
www.calamp.com
QuickStartGuide
ViperSC+BaseStation
DIGITALINFRASTRUCTUREFORVIPERSC+SERIES
©20092013CalAmp
PN0045100000Rev.B
Revised:March2014
©20092013CalAmp
PN0045100000Rev.B
Allspecifications aretypicaland
subjecttochangewithoutnotice.
CalAmp
1401NRiceAvenue
Oxnard,CA93030
t:805.987.9000|f:805.987.8359
www.calamp.com
SetupandConfiguration
TheseinstructionsallowyoutosetupaViperSC+BaseStationtoverifybasicunit
operationandexperimentwithnetworkdesignsandconfigurations.Toeliminate
unnecessarydisruptionoftrafficontheexistingnetworkwhileyoubecomefamiliar
withtheBaseStation,youshoulduseanetworkIPsubnetaddressthat
doesnot
overlapwithsubnetscurrentlyinuseinyourtestarea.
Antenna&AttenuatorConnection
AnRx/Txantennaisrequiredforbasicoperation.Assembleantennaand
connectorsasshownintheaccompanyingfigure.Antennaandconnectorsare
soldseparately.
Note:Itisimportanttouseattenuationbetweenalldemounitsinthetestnetworkto
reducetheamountofsignalstrengthinthetestenvironment.
DeviceConnections
Refertothediagrambelowforproperdeviceconnections.
ConnectanEthernetcabletothefirstLANportoftheViperSC+andconnecttheother
endintotheEthernetportofyourPC.
PrimarypowerfortheViperSC+mustbewithin1030VDCandmustbecapableof
providing:
10WsupplyforTx
at1W
40WsupplyforTxat5Wor
60WsupplyforTxat10W
ViperSC+Demokitsincludeapowersupplywithspringterminals.Observeproper
polaritywhenconnectingthecablestothepowersupply.Thewhitewiremustbe
connectedto
theredwireorB+supply,asshownintheabovefigure.
AccessingtheViperSC+WebServer
TheViperSC+BaseStationisconfiguredviaaWebbrowserinterfaceandcontainsa
DHCPserverwhichwillautomaticallyassignanIPaddresstoyourPC,howeverinsome
casesitmaybenecessarytochangethenetworksettingsonthePCtoaccepttheIP
addressassignedbythe
ViperDHCPserver.
Step1 EnableanetworkconnectionwiththefollowingLANsettings.IntheInternet
Protocol(TCP/IP)Propertieswindow,selectObtainanIPaddressautomaticallyand
ObtainDNSserveraddressautomatically.ClickOKandclose.
Step2 OpenaWebbrowserandenter192.168.205.254intheAddressbar.
Whenthe
connectionLoginwindowappears,entertheUsername:adminandthePassword:
ADMINISTRATOR(bothadminandADMINISTRATORarecasesensitive)andclickOK.
ViperSC+WebInterfaceandSetupWizard
OnceyouhaveloggedinyouwillseetheHomepageoftheViperWebInterfaceasshown
inthefollowingfigure.Arrangedverticallyontheleftsideisthemainnavigationmenu.
Forquicksetup,selectSetupWizard(beneathHome)fromthemainmenu(alongtheleft
ofthepage).ThefirstpageoftheViperSC+SetupWizardisdisplayed.
TheSetupWizardconsistsoffour(4)steps.Eachstepispresentedasasinglepagewitha
fewsimpleoptions
tofillinorselectfrom.Eachofthefourpagesforeachstepofthe
SetupWizardcontainthebasicconfigurationsettingsthataremostcommonlyrequired
toselectorchangetosetuptheViperSC+BaseStationforspecificfunctionality.Read
theinstructionsforeachpagecarefully.
Instructions
foreachofthesestepsareprovidedonthewebpageforthestep.
TheSetupWizardstepsareasfollows
Step
EthernetIPAddress/SubnetandLoginSecurity:EthernetIPAddress,Username
andPassword.2forRedundantRadiomodels.)
Step
LANConfiguration:EthernetIPAddress/SubnetMaskoftheBaseStation
controllerboard.(Mustbeonsamesubnetasinternalradioorradios.)
Step

PingSettings:PrimaryandSecondaryPingIPAddress,PingTimer,andPing
FailureThreshold.
Step
StaticRoutes:AllowsyoutobuildaRoutingTablebyaddingknownstaticroutes.
Setupcomplete:ClickFinishtosaveandapplytheSetupWizardsettings.
SetupWizardQuickSetup
EnterthefollowingintheSetupWizardforquicksetup.ClickNextasyoucompleteeach
pageinsequence.(YoucanclickPrevioustoreviewsettingsinapreviouspageifneeded.)
Step
RadioAConfiguration(andRadioBConfiguration,ifRedundantBaseStation)
Note:ARedundantBaseStationcontainstwointernalViperradios.The
purposeoftheredundancyissothatifanerrorisdetectedintheprimary
radio,theBaseStationControllerautomaticallyswitchestothebackupradio.
For
thisreason,bothinternalViperradiosmustbeconfiguredwiththesame
settings.SelectRadioAandSelectRadioBbuttonsallowyoutomanually
selectwhichradioiscurrentlytheprimary(active)radio.
‐ EthernetIPAddress:EnteranIPAddressfortheinternalViperradio(s).
Thiswillbedifferent,
butonthesamesubnetasthecontrollerboard
(defaultRadioA/RadioBEthernetIPAddress=192.168.205.1).
Username:andPassword:Thesefieldsarefortheusernameandpassword
usedtologontotheInternalViperradio(s)(defaultUsername=Admin;
Password=ADMINISTRATOR)Important:
Thesearebothcasesensitive.
Step
LANConfiguration:EntertheEthernetIPAddress/SubnetMaskfortheBase
Stationcontrollerboard.TheIPaddressforthecontrollerboardmustbeon
thesamesubnetastheradiointhebasestation(bothradiosifredundant).
‐ EthernetIPAddress:EntertheEthernetIPAddressofthecontrollerboard

(default=192.168.205.254).
‐ EthernetSubnetMask:EntertheSubnetMask(default=255.255.255.0).
Step
PingSettings:(Optional)topingremoteIPaddressestoverifyRFlinkisactive.
‐ PrimaryPingIPAddress:EntertheIPAddressoftheprimaryremotethat
pingswillbesentto,todetermineiftheRFlinkisworking(default=blank).
‐ SecondaryPingIPAddress:Enterthe
IPAddressofthesecondaryremote
towhichpingswillbesentifpingstotheprimaryfail(default=blank).
‐ PingTimer:Entertheamountoftime(inmultiplesof5seconds)between
eachpingthatissent(default=0,disabled).
‐ PingFailureThreshold:Enterthe
numberofpingfailuresallowed
Step
StaticRoutes&RoutingTable:(Optional)Enterstaticroutesintoatable.
‐ RouteName:Enteranamefortheroutebywhichyouwillrecognizethe
routeentryintheRoutingTabledisplayedinthelowerpartofthepage.
‐ DestinationAddress:EntertheIPAddressofthedestination
network.
(ThisisanetworknameandnotanactualIPaddress.)
‐ GatewayIPAddress:EntertheIPAddressofthelocalgateway.
‐ Metric:Enteranumberrangingfrom1to65,535.Generallythelowerthe
metricvalue,thehigherthepriority.Typicallysetto1.
‐ ClickAdd
toaddtherouteyouhavedefinedtotheRoutingtablebelow.
ClickFinishtofinishtheSetupWizard.Yourunitwillnowfunctionwiththenew
configuration.
CheckForNormalOperation
Tosimulatedatatrafficovertheradionetwork,usethePCconnectedtotheViperSC+
BaseStationEthernetporttoPingeachunitinthenetworkmultipletimes.Formore
informationaboutconfiguringtheViperSC+BaseStation,refertotheViperSC+Base
StationUserManual(PN0015100
000).
TechnicalSupport
Forassistancewiththisproduct,contactCalAmptechnicalsupport.
Email [email protected]
Phone 1.507.833.6701,Option2forFixed,Narrowband,andRadioModemproducts
OrvisittheSupportsectionofourwebsiteathttp://www.calamp.com/productsupport.
ABOUTCALAMP
CalAmpisaleadingproviderofwirelesscommunicationsproductsthatenableanytime/anywhere
accesstocriticalinformation,dataandentertainmentcontent.Withcomprehensivecapabilities
rangingfromproductdesignanddevelopmentthroughvolumeproduction,CalAmpdeliverscost
effectivehighqualitysolutionstoabroadarrayofcustomersandendmarkets.CalAmpisthe
leadingsupplierofDirectBroadcastSatellite(DBS)outdoorcustomerpremiseequipmenttothe
U.S.satellitetelevisionmarket.TheCompanyalsoprovideswirelessdatacommunicationsolutions
forthetelemetryandassettrackingmarkets,privatewirelessnetworks,InteroperableTrainControl
(ITC)radiotransceiversforuseinrailroadPositiveTrainControl(PTC)applications,
publicsafety
communicationsandcriticalinfrastructureandprocesscontrolapplications.Foradditional
information,pleasevisittheCompany’swebsiteatwww.calamp.com.
/