Zennio ZVIF1/2/4/6V2 Owner's manual

Type
Owner's manual

This manual is also suitable for

Flat v2 & Flat 55 v2
1/2/4/6-Button Capacitive Touch Panel
1/2/4-Button 55x55mm Capacitive Touch Panel
ZVIF1V2 / ZVIF2V2 / ZVIF4V2 / ZVIF6V2
ZVIF55X1V2 / ZVIF55X2V2 / ZVIF55X4V2
USER MANUAL
Application Programme Version: [1.5]
User Manual Version: [1.5]_b
www.zennio.com
Flat v2 & Flat 55 v2
http://www.zennio.com Technical Support: http://support.zennio.com
2
CONTENTS
Contents ........................................................................................................................................ 2
Document updates ........................................................................................................................ 3
1 Introduction ........................................................................................................................... 4
1.1 Flat v2 / Flat 55 v2 .......................................................................................................... 4
1.2 Installation ..................................................................................................................... 6
1.3 Start-Up and Power Loss................................................................................................ 8
2 Configuration ......................................................................................................................... 9
2.1 General .......................................................................................................................... 9
2.1.1 Configuration ............................................................................................................. 9
2.1.2 Temperature Sensor ................................................................................................ 12
2.1.3 Backlight ................................................................................................................... 12
2.1.4 Sounds ...................................................................................................................... 12
2.1.5 Ambient Luminosity Sensor ..................................................................................... 14
2.1.6 Advanced ................................................................................................................. 14
2.2 Buttons ......................................................................................................................... 18
2.2.1 Configuration ........................................................................................................... 19
2.2.2 Disabled.................................................................................................................... 22
2.2.3 Individual .................................................................................................................. 22
2.2.4 Pair ........................................................................................................................... 33
2.3 Inputs ........................................................................................................................... 39
2.3.1 Binary Input .............................................................................................................. 39
2.3.2 Temperature Probe .................................................................................................. 39
2.3.3 Motion Detector ...................................................................................................... 39
2.4 Thermostat .................................................................................................................. 40
ANNEX I. LED Illumination Modes ............................................................................................... 41
ANNEX II. Communication Objects.............................................................................................. 44
Flat v2 & Flat 55 v2
http://www.zennio.com Technical Support: http://support.zennio.com
3
DOCUMENT UPDATES
Version
Page(s)
[1.5]_b
-
-
Flat v2 & Flat 55 v2
http://www.zennio.com Technical Support: http://support.zennio.com
4
1 INTRODUCTION
1.1 FLAT V2 / FLAT 55 V2
Flat v2 and Flat 55 v2 are KNX multifunction capacitive touch switch from Zennio
with proximity sensor, luminosity sensor and backlighted buttons.
They are offered at a reduced size and weight, with one, two, four or six capacitive
touch buttons for Flat v2, and one, two or four for Flat 55 v2 (according to the user’s
needs) with LED backlight to confirm the press of the buttons as well as showing states.
Flat 55 v2 are designed to be installed in standard mechanism boxes with 55x55 frames.
Flat v2 / Flat 55 v2 is a fully customisable solution for the control of rooms where user
control of air conditioning systems, lighting, blinds, scenes, etc. is required.
The versatility offered by the functionality of buttons is complemented by the two built-in
analogue/digital inputs, the internal temperature sensor (only in Flat v2) and the
thermostat function, as well as an elegant and fully customisable design of the front
glass customers can choose their button icons, texts and colours and even personalise
the background with their pictures, logos, etc.
The most outstanding features of Flat v2 / Flat 55 v2 are:
Fully customisable design of the front glass.
1 / 2 / 4 / 6 (only in Flat v2) touch buttons, which can operate as individual or
pair controls:
Horizontally or vertically-oriented configuration (only available for the two-
button and six-button models).
Light indicator (LED) for every button.
Buzzer for an audible acknowledgement of user actions (with the possibility of
disabling it either by parameter or by object).
Possibility of locking / unlocking the touch panel through binary orders or
scenes.
Flat v2 & Flat 55 v2
http://www.zennio.com Technical Support: http://support.zennio.com
5
Welcome Back object (binary or scene) which is sent to the KNX bus when a
pulsation is detected after a certain period (configurable) of intactivity.
Built-in temperature sensor (only in Flat v2).
Ambient luminosity sensor for brightness automatic adjustment.
Proximity sensor for quick start.
Two analogue/digital inputs (for motion detectors, temperature probes,
additional switches, etc.).
Thermostat function.
Heartbeat or periodical “still-alive” notification.
Flat v2 & Flat 55 v2
http://www.zennio.com Technical Support: http://support.zennio.com
6
1.2 INSTALLATION
Figure 1 and 2 shows the connection outline of Flat v2 and Flat 55 v2 respectively:
Figure 1 Schematic diagram of Flat v2.
Figura 2 Schematic diagram of Flat 55 v2
Flat v2 / Flat 55 v2 is connected to the KNX bus through the built-in terminal (2 / 3). An
external DC power supply is not needed.
A short press on the Prog./Test button (4 / 5) will make the device enter the
programming mode. The Prog./Test LED (3 / 4) will then light in red. On the contrary, if
this button is held while the device gets connected to the bus, the device will enter the
safe mode. In such case, the programming LED will blink in red colour.
1. Temperature Probe.
2. KNX Connector.
3. Programming LED.
4. Programming Button.
5. Fixing Clips.
6. Input Connectors.
7. Touch Buttons.
8. Proximity and Luminosity Sensors.
1. Frame (sold separately).
2. Metal leveling plate.
3. KNX Connector
4. Programming LED.
5. Programming Button.
6. Fixing Clips.
7. Input Connectors.
8. Touch Buttons.
9. Proximity and Luminosity Sensors.
3
2
7
5
4
6
1
8
Flat v2 & Flat 55 v2
http://www.zennio.com Technical Support: http://support.zennio.com
7
For detailed information about the technical features of Flat v2 / Flat 55 v2, as well as on
security and installation procedures, please refer to the device Datasheet, bundled
within the device packaging and also available at www.zennio.com.
Flat v2 & Flat 55 v2
http://www.zennio.com Technical Support: http://support.zennio.com
8
1.3 START-UP AND POWER LOSS
After download or device reset it is necessary to wait for about 2 minutes without
performing any action in order to make it possible a proper calibration of:
Proximity sensor.
Luminosity sensor.
Button presses.
For a correct calibration of the proximity and brightness sensors it is recommended not
to remain too close or place anything less than 50cm approximately and do not hit with
direct light to the device during this time.
Flat v2 & Flat 55 v2
http://www.zennio.com Technical Support: http://support.zennio.com
9
2 CONFIGURATION
After importing the corresponding database in ETS and adding the device into the
topology of the project, the configuration process begins by entering the Parameters tab
of the device.
2.1 GENERAL
In order to allow the device to perform the desired functions, a number of options must
be parameterized, either related to its general behaviour (horizontal/vertical orientation,
sounds, LED brightness levels…) or to advanced features (lock procedure of the touch
panel, cleaning function, welcome back object).
2.1.1 CONFIGURATION
In the "Configuration" tab, the general settings are displayed. Most are checkboxes that
enable/disable other functionalities
ETS PARAMETERISATION
The following parameters are shown:
Device Orientation [Vertical (Normal)
1
/Horizontal (Rotated)]: allows assigning
a horizontal or vertical orientation to the device, making it easier to identify
the push-buttons during the configuration process (ETS will show a figure with
the final distribution of the push-buttons). To prevent inconsistency in the
configuration, please note the following criterium:
Vertical (normal):
Temperature probe hole
(only in Flat v2) on the
right of the bottom side
and the sensors on the
middle of the top side.
Horizontal (rotated):
Temperature probe hole
(only in Flat v2) on the
top of the right side and
sensors on the middle of
the left side.
Figure 3 Orientation.
1
The default values of each parameter will be highlighted in blue in this document, as follows:
[default/rest of options].
Flat v2 & Flat 55 v2
http://www.zennio.com Technical Support: http://support.zennio.com
10
Figure 4 Main configuration.
Buttons [enabled]: read-only parameter to make it evident that the “Buttons”
tab is always enabled in the tab tree on the left. See section 2.2 for details.
Inputs [disabled/enabled]: enables or disables the “Inputs” tab in the tree on
the left, depending on whether the device will or will not be connected any
external accessories. See section 2.3 for details.
Thermostat [disabled/enabled]: enables or disables the “Thermostat” tab in
the tree on the left. See section 2.4 for details.
Heartbeat (Periodic Alive Notification) [disabled/enabled]: incorporates a
one-bit object to the project ([Heartbeat] Object to Send ‘1’”) that will be sent
periodically with value “1” to notify that the device is still working (still alive).
Flat v2 & Flat 55 v2
http://www.zennio.com Technical Support: http://support.zennio.com
11
Figure 5. Heartbeat.
Note: the first sending after download or bus failure takes place with a delay of
up to 255 seconds, to prevent bus overload. The following sendings march the
period set.
Internal Temperature Sensor (only in Flat v2) [disabled/enabled]: enables or
disables the “Temperature Sensor” tab in the tree on the left. See section 2.1.2
for details.
Sounds [Default / Custom]: sets whether the sound functions (button beeps,
alarm and doorbell) should work according to the pre-defined configuration or
to a user-defined configuration. See section 2.1.4 for details.
Ambient luminosity sensor [disabled/enabled]: enables setting the ambient
luminosity sensor. When the sensor is enabled, a new tab for its configuration
is shown. See section 2.1.5 for details.
Proximity Sensor [disabled/enabled]: enables the proximity sensor. This
functionality permits “waking up” the device when detecting presence.
Please refer to the specific manual Proximity and Luminosity Sensor
(available in the Flat v2 / Flat 55 v2 product section at the Zennio homepage,
www.zennio.com) for detailed information about the functionality and the
configuration of the related parameters.
Time to Consider Inactivity [1…30…255][s/min/h]: allows setting a time after
which, if no pulsation or proximity detection has occurred, the LEDs turn off (or
acquire the brightness level configured, see section 2.1.3).
Advanced Configuration [disabled/enabled]: enables or disables the
“Advanced” tab in the tree on the left. See section 2.1.6 for details.
Flat v2 & Flat 55 v2
http://www.zennio.com Technical Support: http://support.zennio.com
12
2.1.2 TEMPERATURE SENSOR
Note: This functionality is only available in Flat v2.
Flat v2 is equipped with one internal temperature probe which can monitor the ambient
temperature of the room, thus making the device capable of reporting it to the KNX bus
and of triggering certain actions when the temperature reaches specific values.
Please refer to the specific manual Temperature Probe (available in the Flat v2
product section at the Zennio homepage, www.zennio.com) for detailed information
about the functionality and the configuration of the related parameters.
2.1.3 BACKLIGHT
Flat v2 / Flat 55 v2 allows managing the brightness of the LED according to two operating
modes: normal mode and night mode.
Please refer to the specific manual Brightness (available in the Flat v2 / Flat 55 v2
product section at the Zennio website, www.zennio.com) for detailed information about
the functionality and the configuration of the related parameters.
2.1.4 SOUNDS
It is possible to configure Flat v2 / Flat 55 v2 so that a brief beep is emitted as an acoustic
feedback when a button is pressed.
Enabling the button sounds can be done either by parameters or through an object, being
also possible to define in parameters if the button sounds should be initially enabled or
not.
Moreover, Flat v2 / Flat 55 v2 can also emit the following sounds on request (through the
corresponding communication objects) if enabled:
Doorbell sounds: a single beep.
Alarm sounds: a sequence of brief beeps with a higher pitch. The sequence
will only stop when the alarm object gets deactivated or when the user touches
any of the buttons (this, moreover the deactivation alarm, will trigger the button
action).
The range of sounds emitted will be different depending on the sound type selected.
Flat v2 & Flat 55 v2
http://www.zennio.com Technical Support: http://support.zennio.com
13
ETS PARAMETERISATION
In case the default button beep sound matches the requirements of the installation and
the doorbell and alarm functions are not necessary, the Sounds parameter in the general
Configuration tab (see section 2.1.1) can be set to Default”. This will also imply that
the button beeps will be unconditional, as it will not be possible to disable this function
through an object.
On the other hand, if set to “Custom”, a specific tab named Sounds” will show up in the
tab tree on the left. The initial configuration of this screen is equivalent to the
aforementioned default option. However, the following parameters will be configurable.
Figure 6. Sounds.
The default configuration of this tab is equivalent to the one mentioned above. However,
the following parameters can be customized:
Sound Type [Sound 1 / Sound 2]: sets which sounds range incorporates the
device.
Disable button sound [disabled/enabled]: enables the buttons beeping. If
enabled, the following parameters will also be available:
Enable / Disable button sounds through a 1-bit object
[disabled/enabled]: makes it possible to disable / resume the button beeping
function in runtime by writing to a specific object (“[General] Sounds
Disabling button sound”). If enabled, it will be shown:
Value [0 = Disabled; 1 = Enabled / 1 = Disabled; 0 = Enabled]: allows
configuring the values (0 or 1) that will disable/resume the sounds.
Flat v2 & Flat 55 v2
http://www.zennio.com Technical Support: http://support.zennio.com
14
Status After ETS Download [enabled/disabled]: sets whether the button
beeping function should start up enabled or disabled after an ETS download.
Object for Doorbell [disabled/enabled]: enables or disables the doorbell
function. If enabled, a specific object (“[General] Sounds - Doorbell”) will be
included into the project topology.
Object for Alarm Bell [disabled/enabled]: enables or disables the alarm
function. If enabled, a specific object (“[General] Sounds - Alarm”) will be
included into the project topology.
2.1.5 AMBIENT LUMINOSITY SENSOR
Flat v2 / Flat 55 v2 incorporates a luminosity sensor to receive and monitor ambient
brightness measurement.
Please refer to the specific manual Luminosity and Proximity Sensor(available in
the Flat v2 / Flat 55 v2 product section at the Zennio homepage, www.zennio.com) for
detailed information about the functionality and the configuration of the related
parameters.
2.1.6 ADVANCED
Independent tab for the parameterisation of some advanced functions. These functions
are explained next.
ETS PARAMETERISATION
After enabling the Advanced configuration from Configuraciónscreen (see section
2.1.1), a new tab will be incorporated into the tree on the left.
Figure 7. Advanced.
Flat v2 & Flat 55 v2
http://www.zennio.com Technical Support: http://support.zennio.com
15
Touch locking [disabled/enabled]: enables or disables the “Touch locking” tab
in the tree on the left. See section 2.1.6.1 for details.
Welcome back object [disabled/enabled]: enables or disables the “Welcome
back” tab in the tree on the left. See section 2.1.6.2 for details.
2.1.6.1 TOUCH LOCKING
The touch panel of Flat v2 / Flat 55 v2 can be optionally locked and unlocked anytime by
writing a configurable one-bit value to a specific object provided for this purpose. It can
also be done through scene values.
While locked, pressing on the buttons will be ignored: no actions will be performed (and
no LEDs will change their states) when the user touches on any of the controls.
ETS PARAMETERISATION
After enabling Touch Locking in “Advancedtab, a new tab will be incorporated into the
tree on the left.
Figure 8. Touch Locking: Control.
Control Object: 1-Bit [disabled/enabled]: when marked, a specific drop-down
list will show up to select which value should trigger which action.
Value [0 = Unlock; 1 = Lock / 0 = Lock; 1 = Unlock]: these values are
received through the object “[General] Touch Locking”.
Scene Object [disabled/enabled]: when marked, two specific textboxes will
show up to enter the scene numbers (1 - 64) that should trigger each action.
These values are to be received through the general [General] Scene:
Receive” object.
Flat v2 & Flat 55 v2
http://www.zennio.com Technical Support: http://support.zennio.com
16
2.1.6.2 WELCOME BACK OBJECT
Flat v2 / Flat 55 v2 can send a specific object (the welcome back object) to the KNX bus
when the user presses a touch button after a significant amount of time since the last or
presence detection (when the proximity sensor is enabled). Sending it or not can also
depend on an additional, configurable condition consisting in the evaluation of up to
five binary objects.
Any actions that in normal operation may be executed will not be if the welcome back
object is sent to the bus. Thus, if the user presses a button and this causes that the
welcome back object is sent, the normal action of that button will not be triggered.
On the other hand, if the additional condition is not evaluated to true, the device will react
normally. Hence, the action corresponding to the button touch will be executed.
The welcome back object can consist in a one-bit value or a scene value (or both),
depending on the parameterisation.
ETS PARAMETERISATION
After enabling Welcome Back Object, a new tab will be incorporated into the tree on
the left.
Figure 9 Welcome Back Object.
This screen contains the following parameters:
Timeout to Activate the Welcome Object [1…255][s/min/h]: sets the
minimum time that should elapse after the last button touch touch (or presence
detection, when the proximity sensor is enabled) before the next one triggers
the execution of the welcome back function.
Flat v2 & Flat 55 v2
http://www.zennio.com Technical Support: http://support.zennio.com
17
Sending Trigger [Push Button/Proximity Detection]: sets whether the welcome
back object is sending after a touch in the screen or when the proximity sensor
detects presence.
Additional Condition: sets if sending the welcome back object should also
depend on an external condition. The option by default is [No Additional
Condition]. The following are available too:
[Do not send unless all additional conditions are 0]: the welcome back object
will only be sent if all the condition objects are found to have the value “0”.
[Do not send unless all additional conditions are 1]: the welcome back object
will only be sent if all the condition objects are found to have the value “1”.
[Do not send unless at least one of the additional conditions is 0]: the
welcome back object will only be sent if at least one of the condition objects
is found to have the value “0”.
[Do not send unless at least one of the additional conditions is 1]: the
welcome back object will only be sent if at least one of the condition objects
is found to have the value “1”.
Welcome Back Object (1-Bit) [disabled/enabled]: checkbox to enable the
sending of a 1-bit value (through [General] Welcome back”) when the welcome
back function is triggered and the condition (if any) evaluates to true. The desired
value should set in Value [Send 0 / Send 1].
Welcome Back Object (Scene) [disabled/enabled]: checkbox to enable the
sending of a scene run request (through [General] Scene: send”) when the
welcome back function is triggered and the condition (if any) evaluates to true.
The desired value should be set in Scene Number [1…64].
Flat v2 & Flat 55 v2
http://www.zennio.com Technical Support: http://support.zennio.com
18
2.2 BUTTONS
Flat v2 / Flat 55 v2 has one, two, four or six (only in Flat v2) capacitive buttons
(depending on the model) at the user’s disposal for the execution of actions.
The distribution of the buttons will depend on the model, being possible to configure them
as single-button controls or in pairs by combining any two of them.
There are some differences in the button configuration depending on the model:
Flat 1 v2 / Flat 55 X1 v2: due to the existence of only one push button, only
one individual control is possible (two-button controls are not available).
Moreover, it can only be configured under the normal (vertical) orientation.
Figure 10 Flat 1 v2 and Flat 55 X1 v2
Flat 2 v2 / Flat 55 X2 v2: up to two one-button controls can be configured, or
either one two-button control, and under any of the two orientations for Flat 2
v2.
Figure 11 Flat 2 v2 and Flat 55 X2 v2. Normal orientation.
Figura 12. Flat 2 v2. Rotated orientation.
Flat 4 v2 / Flat 55 X4 v2 up to four one-button controls can be configured, or
up to two two-button controls (by combining any two buttons for each pair). The
Flat v2 & Flat 55 v2
http://www.zennio.com Technical Support: http://support.zennio.com
19
figure shows which number identifies each button during the configuration
process.
Figure 13 Flat 4 v2 and Flat 55 X4 v2.
Flat 6 v2: up to six one-button controls, or three two-button controls (by
combining any two push buttons for each pair) can be configured, under any of
the two orientations. The figure shows which number identifies each button
during the configuration process.
Figure 14 Flat 6 v2. Normal orientation (left) and rotated (right).
2.2.1 CONFIGURATION
The following is a list of the functions that can be assigned to each button.
Disabled (the button will not react to user presses).
Pair A, B or C (the number of available pairs depends on the selected model),
being the function of such pair one of the following:
Switch (binary).
Two objects (short press / long
press).
Light dimmer.
Shutter.
Individual (one-button control):
Switch (Binary).
Hold & release.
Two objects (short press / long
press).
Scene.
Flat v2 & Flat 55 v2
http://www.zennio.com Technical Support: http://support.zennio.com
20
Scaling constant.
Counter constant.
Float constant.
Light dimmer.
Shutter.
LED indicator.
Room State
Apart from the button function itself, the desired behaviour of the button LEDs can be
set. The different illumination modes have been detailed in ANNEX I. LED Illumination
Modes.
The next sections explain the configuration involved for each of the above functions.
ETS PARAMETERISATION
An independent tab for the parameterisation of the buttons is shown in ETS by default,
initially containing only a sub-tab named Configuration.
Figure 15 Buttons - Configuration
One drop-down list with the following options is shown per button:
[Disabled]. See section 2.2.2 for details.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54

Zennio ZVIF1/2/4/6V2 Owner's manual

Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI