Baselyte-BSL7

Lightolier Baselyte-BSL7 User manual

  • Hello! I am an AI chatbot trained to assist you with the Lightolier Baselyte-BSL7 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
  • What is the Finish of the product?
    What is the maximum load the product can support?
    What are the module lengths available?
    What is the voltage of the product?
    What is the wattage of the product?
Lighting Systems Baselyte-BSL7
Page 1 of 8 4 Light T5 HO Direct/Indirect
Job Information
Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
Lightolier a Genlyte Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2005 Genlyte Group LLC • 0205 Rev.1
Ordering Information
Family
H = T5 HO
6 = Direct/
Indirect
04
CN
H
6
BSL
04 = 4 Light
CN = Cutout
w/baffles
04 = 4’
08 = 8’
12 = 12’
C = Custom Color
W = Standard
White
Distribution
Lamp Type
No. of Lamps
Housing
Module Length
Wiring
Voltage
Ballast Finish
Weight = 3.0 lb./ft
E = Standard
<10% THD
F = Standard
<10% THD
w/fusing
1 = 1cct.
2 = 2cct.
3 = 1cct. w/EC/NL
4 = 2cct. w/EC/NL
5 = 1cct. w/EM Battery
6 = 2cct. w/EM Battery
7 = 1cct. w/Dimming
8 = 1cct. w/1cct.
Thru wire
9 = 2cct. w/1cct.
Thru wire
Note: Please consult
wiring section of spec
sheets for more
wiring options.
Specifications
Features
1. Housing: die-formed 20ga. cold rolled steel
2. End Set: die-cast metal with baked powder coat finish
3. Lamping: four T5 HO lamps
4. Configuration: 4’, 8’ and 12’ module lengths or continuous rows
5. Ballasts: electronic 120V or 277V
Finish
High-quality white powder coat with textured matte finish.
Custom colors available. Consult factory.
Mounting
Aircraft cable gripper is tamper-resistant and provides infinite vertical
adjustment capability. Aircraft cable, crimp and cable gripper independently
tested to meet stringent safety requirements.
Electrical
All luminaires are factory pre-wired to module ends with quick-wire
connectors.
Joints & Intersections
Self-aligning joining system with hands-free pre-joining wire access.
Labels
UL, CSA standards.
Individual Fixtures
1. Determine the number of individual modules required
2. Order one end set per module
3. Order one non-power mount per module
4. Order one power mount per module
Continuous Rows*
1. Determine run length
2. Order the appropriate number and length of modules for complete run
3. Order one end set for each run
4. Order one non-power mount for each module
5. Order one power mount per run
6. Order one joiner per module minus one (e.g. 3 modules requires 2 joiners)
*Note: Some runs may require additional power mounts. Please see the
‘Run Configuration’ table on the next page for more details.
Ordering Instructions
D = Dual 120V
& 277V
1 = 120V
2 = 277V
Note: Option‘D’ is
standard. Voltage
options 1 and 2 are
only available with
EM Battery and
Dimming wiring
options.


Lighting Systems Baselyte-BSL7
Page 2 of 8 4 Light T5 HO Direct/Indirect
Lightolier a Genlyte Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2005 Genlyte Group LLC • 0205 Rev.1
Job Information Type:
Performance
Candlepower Curve Candlepower Summary Coefficients of Utilization
-ODULE,ENGTH
-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
@
@
@
Module Lengths & Mounting Distances
Joiner
BSLESW = suspended standard white
End Set
BSLJS = suspended joiner
System Components & Accessories
Run Configuration
Report No: 2101637
Lamps: F54T5
Lumens per Lamp: 4650
Efficiency: 88.5%
Up: 87.0% Down: 13.0%
Run
Length
4’
Module
8’
Module
12’
Module
Joiner End Set Mount
Power
Mount*
4’ run 1 1 1 1
8’ run 1 1 1 1
12’ run
1 1 1 1
16’ run
2 1 1 2 1
20’ run 1 1 1 1 2 1
24’ run 2 1 1 2 1
28’ run 2 1 2 1 3 1
32’ run 1 2 2 1 3 1
Zonal Lumen Summary
ZONE LUMENS %BARE LAMP %LUMINAIRE






















CANDLEPOWER SUMMARY
ZONE CANDLEPOWER
DEG. 0 22.5 45 67.5 90
180 3780 3780 3780 3780 3780
175 3757 3762 3776 3787 3790
165 3617 3654 3726 3782 3804
155 3361 3443 3610 3745 3800
145 2994 3135 3442 3704 3795
135 2527 2752 3231 3577 3701
125 1981 2325 2930 3286 3418
115 1384 1867 2442 2658 2768
105 742 1261 1585 1586 1679
95 166 337 474 409 489
90 11 47 67 76 77
85 34 51 74 82 86
75 84 94 110 120 125
65 151 207 181 172 177
55 313 347 319 261 265
45 513 446 495 456 453
35 712 621 610 638 643
25 896 849 715 689 710
15 1044 1064 978 895 891
5 1135 1136 1152 1160 1162
0 1144 1144 1144 1144 1144
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10
0 87 87 87 76 76 76 55 55 55
1 75 72 69 66 63 61 48 46 45
2 66 61 56 58 53 50 42 39 37
3 58 52 47 51 46 42 37 34 31
4 51 44 39 45 39 35 33 29 26
5 45 38 34 40 34 30 29 26 23
6 40 34 29 35 30 26 26 22 20
7 36 30 25 32 26 22 24 20 17
8 33 26 22 29 23 20 21 18 15
9 30 23 19 26 21 17 19 16 13
10 27 21 17 24 19 15 18 14 12
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP %LUMINAIRE
0-90
90-180
0-180
16458
14324
2134 13.0
87.0
100.0
11.5
77.0
88.5
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10
0 87 87 87 76 76 76 55 55 55
1 75 72 69 66 63 61 48 46 45
2 66 61 56 58 53 50 42 39 37
3 58 52 47 51 46 42 37 34 31
4 51 44 39 45 39 35 33 29 26
5 45 38 34 40 34 30 29 26 23
6 40 34 29 35 30 26 26 22 20
7 36 30 25 32 26 22 24 20 17
8 33 26 22 29 23 20 21 18 15
9 30 23 19 26 21 17 19 16 13
10 27 21 17 24 19 15 18 14 12
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP %LUMINAIRE
0-90
90-180
0-180
16458
14324
2134 13.0
87.0
100.0
11.5
77.0
88.5
Note: Shaded area indicates locations of emergency sections (emergency wiring
controls all lamps or optional battery pack controls one or two lamps).
*Note: Additional power mounts may be required for some runs with T5 HO
lamping options, longer runs, and runs with wiring options that are more complex.
Please consult factory for assistance.
Lighting Systems Baselyte-BSL7
Page 3 of 8 4 Light T5 HO Direct/Indirect
Lightolier a Genlyte Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2005 Genlyte Group LLC • 0205 Rev.1
Job Information Type:
• 65 lbs maximum load
• Canopy: Diameter of 3 3/4“x 7/32”
• Cable: 7x7 stranded aircraft cable
• Supported by T-bar and secured to structure
• J-Box: 4” square (supplied by others)
• Fully adjustable vertically at fixture
Mount Type: T-Bar 15/16” (On-Grid)*
Mount Type: T-Bar 9/16” (On-Grid)*
Mount Type: T-Bar 9/16” by 5/16” Slot Grid (On-Grid)*
Supension Length
Non-Power Mount1-Power Mount
1-Power Mount
2’ 4’ 8’ 12’
3 Conductor
BSLM6102P13 BSLM6104P13 BSLM6108P13 BSLM6112P13
4 Conductor
BSLM6102P14 BSLM6104P14 BSLM6108P14 BSLM6112P14
7 Conductor
BSLM6102P17 BSLM6104P17 BSLM6108P17 BSLM6112P17
Non-Power Mount
BSLM6102N BSLM6104N BSLM6108N BSLM6112N
• 65 lbs maximum load
• Canopy: Diameter of 3 3/4“x 7/32”
• Cable: 7x7 stranded aircraft cable
• Supported by T-bar and secured to structure
• J-Box: 4” square (supplied by others)
• Fully adjustable vertically at fixture
• 65 lbs maximum load
• Canopy: Diameter of 3 3/4“x 7/32”
• Cable: 7x7 stranded aircraft cable
• Supported by T-bar and secured to structure
• J-Box: 4” square (supplied by others)
• Fully adjustable vertically at fixture
*Note: Standard T-bar mounts are currently not available for tegular tile ceilings,
however
certain tegular tile / T-bar combinations may be supported by the use of the
slot-grid mount. For more information, please consult factory.
Supension Length
Non-Power Mount1-Power Mount
1-Power Mount
2’ 4’ 8’ 12’
3 Conductor
BSLM6202P13 BSLM6204P13 BSLM6208P13 BSLM6212P13
4 Conductor
BSLM6202P14 BSLM6204P14 BSLM6208P14 BSLM6212P14
7 Conductor
BSLM6202P17 BSLM6204P17 BSLM6208P17 BSLM6212P17
Non-Power Mount
BSLM6202N BSLM6204N BSLM6208N BSLM6212N
Supension Length
Non-Power Mount1-Power Mount
1-Power Mount
2’ 4’ 8’ 12’
3 Conductor
BSLM6302P13 BSLM6304P13 BSLM6308P13 BSLM6312P13
4 Conductor
BSLM6302P14 BSLM6304P14 BSLM6308P14 BSLM6312P14
7 Conductor
BSLM6302P17 BSLM6304P17 BSLM6308P17 BSLM6312P17
Non-Power Mount
BSLM6302N BSLM6304N BSLM6308N BSLM6312N
Mounting Options
Lighting Systems Baselyte-BSL7
Page 4 of 8 4 Light T5 HO Direct/Indirect
Lightolier a Genlyte Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2005 Genlyte Group LLC • 0205 Rev.1
Job Information Type:
Mount Type: T-Bar Fixed Position (1/4-20 Threaded Rod)
Mount Type: T-Bar Variable Position
Mount Type: Support or Open-Joist Ceiling
Supension Length
Non-Power Mount1-Power Mount 2-Power Mount
1-Power Mount
2’ 4’ 8’ 12’
3 Conductor
BSLM2102P13 BSLM2104P13 BSLM2108P13 BSLM2112P13
4 Conductor
BSLM2102P14 BSLM2104P14 BSLM2108P14 BSLM2112P14
2-Power Mount
3 Conductor
BSLM2102P23 BSLM2104P23 BSLM2108P23 BSLM2112P23
Non-Power Mount
BSLM2102N BSLM2104N BSLM2108N BSLM2112N
Supension Length
1-Power Mount
2’ 4’ 8’ 12’
3 Conductor
BSLM5102P13 BSLM5104P13 BSLM5108P13 BSLM5112P13
4 Conductor
BSLM5102P14 BSLM5104P14 BSLM5108P14 BSLM5112P14
7 Conductor
BSLM5102P17 BSLM5104P17 BSLM5108P17 BSLM5112P17
2-Power Mount
3 Conductor
BSLM5102P23 BSLM5104P23 BSLM5108P23 BSLM5112P23
Non-Power Mount
BSLM5102N BSLM5104N BSLM5108N BSLM5112N
Supension Length
1-Power Mount
2’ 4’ 8’ 12’
3 Conductor
BSLM3102P13 BSLM3104P13 BSLM3108P13 BSLM3112P13
4 Conductor
BSLM3102P14 BSLM3104P14 BSLM3108P14 BSLM3112P14
7 Conductor
BSLM3102P17 BSLM3104P17 BSLM3108P17 BSLM3112P17
2-Power Mount
3 Conductor
BSLM3102P23 BSLM3104P23 BSLM3108P23 BSLM3112P23
Non-Power Mount
BSLM3102N BSLM3104N BSLM3108N BSLM3112N
Non-Power Mount1-Power Mount 2-Power Mount
Non-Power Mount1-Power Mount 2-Power Mount
• Meets UBC, OSHPD and DSA seismic requirements
• Canopy: Diameter of 5 1/4“x 3/4” (power)
• Cable: 7x7 stranded aircraft cable
• Tile cut-out hole: Diameter of 2 1/2” (power) or 3/4” (non-power)
• J-Box: Integral J-Box supplied
• 1/4 - 20 all thread rod (supplied by others)
• Fully vertically adjustable at fixture
Meets UBC, OSHPD and DSA seismic requirements
Canopy: Diameter of 5
1/4
“x
3/4
(power)
• Cable: 7x7 stranded aircraft cable
• Versatile mount, fully adjustable to accomodate open sloped ceilings
• J-Box: 4” octogonal box (supplied by others)
• Fully vertically adjustable at fixture
• Meets UBC, OSHPD and DSA seismic requirements
• Canopy: Diameter of 3“x 7/32”
• Cable: 7x7 stranded aircraft cable
• Tile cut-out hole: Diameter of 2 1/4”
• Aligned by T-bar and secured to structure
• J-Box 4” square (supplied by others)
• Fully vertically adjustable at fixture
• Adjusts to both 1” and 1 1/2” high T-bar systems
*Note: Supports 15/16”, 9/16” and slot grid ceiling types.
Lighting Systems Baselyte-BSL7
Page 5 of 8 4 Light T5 HO Direct/Indirect
Lightolier a Genlyte Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2005 Genlyte Group LLC • 0205 Rev.1
Job Information Type:
Mount Type: Non-Accessible Ceilings (concrete, gypsum etc.)
Supension Length
Non-Power Mount1-Power Mount 2-Power Mount
1-Power Mount
2’ 4’ 8’ 12’
3 Conductor
BSLM1102P13 BSLM1104P13 BSLM1108P13 BSLM1112P13
4 Conductor
BSLM1102P14 BSLM1104P14 BSLM1108P14 BSLM1112P14
7 Conductor
BSLM1102P17 BSLM1104P17 BSLM1108P17 BSLM1112P17
2-Power Mount
3 Conductor
BSLM1102P23 BSLM1104P23 BSLM1108P23 BSLM1112P23
Non-Power Mount
BSLM1102N BSLM1104N BSLM1108N BSLM1112N
• Meets UBC, OSHPD and DSA seismic requirements
• Canopy: Diameter of 5
1/4
“x
3/4
” (power)
• Cable: 7x7 stranded aircraft cable
• Mountable on 0º - 15º sloped ceiling
• Optional Chicago Plenum approved version available (A4)
• J-Box: 4” octogonal box (supplied by others)
• Fully vertically adjustable at fixture
Max. 10 amps
Max. 300V
Max. 10 amps in a 1 circuit application
Max. 5 amps per circuit in a 2 circuit application
Max. 300V
Good for 2 circuit feeds or a 1 circuit feed with
a battery pack hot lead
120V or 277V applications
Max. 10 amps in a 1 circuit application
Max. 5 amps per circuit in a multi-circuit
application
Good for 3 circuit feeds or 2 circuit feeds with a
battery pack hot lead
120V or 277V applications
3 Conductor
4 Conductor
7 Conductor
Cord Types
Lighting Systems Baselyte-BSL7
Page 6 of 8 4 Light T5 HO Direct/Indirect
Lightolier a Genlyte Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2005 Genlyte Group LLC • 0205 Rev.1
Job Information Type:
Wiring Options: 1 Circuit
1 Circuit with Emergency Circuit/Night Light (EC/NL)
One 4’ section in a one circuit fixture to be wired on a separate thru circuit. Leads for both normal
circuit and EC/NL circuit wired to fixture ends. All lamps in EC/NL section to be wired together.
Type 3: 1cct. w/EC/NL
All lamps wired on one circuit.
1 Circuit
Type 5: Chloride standard
CTP700
Type M: Bodine standard
LP550
Type E: Chloride high performance
CTP1300
Type P: Bodine high performance
LP600
All lamps wired on one circuit, plus a battery pack is wired to one lamp. A hot lead is connected
to the battery pack and would function as a ‘trigger’ wire when connected to a constant hot by
installer. Leads for both normal circuit and battery pack are wired to fixture ends.
1 Circuit with Emergency Battery Pack (EM)
*Note: Multi-lamp battery packs are also available.
*Note: Multi-lamp battery packs are also available.
One 4’ section in a one circuit fixture to be wired on a separate thru circuit, in addition, a battery
pack is wired to one lamp. Installer can connect ‘trigger’ wire to EC hot lead if controlled together
or wire separately if controlled independently. Leads for normal circuit, EC/NL circuit and EM wired
to fixture ends. All lamps in EC/NL section to be wired together.
1 Circuit with Emergency Circuit/Night Light and Emergency Battery Pack
Type J: Chloride standard
CTP700
%#.,
%#.,
%#.,
%#.,
%-
Type 1: 1cct.
Type 8: 1cct. w/1cct. thru wire
Type H: 1cct. w/2cct. thru wire
Type 7: 1cct. w/dimming
Lighting Systems Baselyte-BSL7
Page 7 of 8 4 Light T5 HO Direct/Indirect
Lightolier a Genlyte Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2005 Genlyte Group LLC • 0205 Rev.1
Job Information Type:
Wiring Options: 2 Circuit Center/Outer Switching
*Note: Multi-lamp battery packs are also available.
Type 6: Chloride standard
CTP700
Type N: Bodine standard
LP550
Type F: Chloride high performance
CTP1300
Type Q: Bodine high performance
LP600
Fixture wired for two circuits (center/outer switching), plus a battery pack is wired to one lamp. A
hot lead is connected to the battery pack and would act as a ‘trigger’ wire when connected to a
constant hot by installer. Leads for both normal circuit and battery pack are wired to fixture ends.
2 Circuit Center/Outer Switching with Emergency Battery Pack (EM)
*Note: Multi-lamp battery packs are also available.
2 Circuit Center/Outer Switching with Emergency Circuit/Night Light (EC/NL)
One 4’ section in two circuit fixture (center/outer switching) to be wired on a separate thru circuit.
Leads for both normal circuit and EC/NL circuit wired to fixture ends. All lamps in EC/NL section to
be wired together.
Type 4: 2cct. w/EC/NL
Fixture wired for two circuit. Lamps wired for center/outer switching.
2 Circuit Center/Outer Switching
Type 2: 2cct.
Type 9: 2cct. w/1cct. thru wire
Type I: 2cct. w/2cct. thru wire
One 4’ section in a two circuit fixture (center/outer switching) to be wired on a separate thru
circuit, in addition, a battery pack is wired to one lamp. Installer can connect ‘trigger’ wire to EC
hot lead if controlled together or wired separately if controlled independently. Leads for normal
circuit, EC/NL circuit and battery pack are wired to fixture ends. All lamps in EC/NL section to be
wired together.
2 Circuit Center/Outer with Emergency Circuit/Night Light and Emergency Battery Pack
Type K: Chloride standard
CTP700
%#.,
%#.,
%#.,
%#.,
%-
%#.,
%#.,
%#.,
%#.,%-
Lighting Systems Baselyte-BSL7
Page 8 of 8 4 Light T5 HO Direct/Indirect
Lightolier a Genlyte Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2005 Genlyte Group LLC • 0205 Rev.1
Job Information Type:
Wiring Options: 2 Circuit A/B Switching (alternate 4’ sections)
*Note: Multi-lamp battery packs are also available.
Type D: Chloride standard
CTP700
Type O: Bodine standard
LP550
Type G: Chloride high performance
CTP1300
Type R: Bodine high performance
LP600
Fixture wired for two circuits (A/B switching), plus a battery pack is wired to one lamp. A hot lead
is connected to the battery pack and would act as a ‘trigger’ wire when connected to a constant hot
by installer. Leads for both normal circuit and battery pack are wired to fixture ends.
2 Circuit A/B Switching (alternate 4’ sections) with Emergency Battery Pack (EM)
*Note: Multi-lamp battery packs are also available.
Fixture wired for two circuit. Lamps wired for A/B switching in alternate 4’ sections.
2 Circuit A/B Switching (alternate 4’ sections)
2 Circuit A/B Switching (alternate 4’ sections) with Emergency Circuit/Night Light (EC/NL)
One 4’ section in a two circuit fixture (A/B switching) to be wired on a separate thru circuit. Leads
for both normal circuit and EC/NL circuit wired to fixture ends. All lamps in EC/NL section to be
wired together.
Type C: 2cct. w/EC/NL
One 4’ section in a two circuit fixture (A/B switching) to be wired on a separate thru circuit, in
addition, a battery pack is wired to one lamp. Installer can connect “trigger” wire to EC hot lead if
controlled together or wired separately if controlled independently. Leads for normal circuit, EC/NL
circuit and battery pack are wired to fixture ends. All lamps in EC/NL section to be wired together.
2 Circuit A/B Switching (alternate 4’ sections) with Emergency Circuit/Night Light and Emergency Battery Pack
Type L: Chloride standard
CTP700
%-
%#.,
%#.,
%#.,
%#.,%-
Type B: 2cct.
Type A: 2cct. w/1cct. thru wire
Type S: 2cct. w/2cct. thru wire
%#.,
%#.,
%#.,
%#.,
/