Axis A8004-VE User manual

Type
User manual

This manual is also suitable for

INSTALLATION GUIDE
AXIS A8004 Junction Box
Legal Considerations
Video and audio surveillance can be prohibited by laws that vary from
country to country. Check the laws in your local region before using this
product for surveillance purposes.
Liability
Every care has been taken in the preparation of this document. Please
inform your local Axis office of any inaccuracies or omissions. Axis
Communications AB cannot be held responsible for any technical or
typographical errors and reserves the right to make changes to the product
and manuals without prior notice. Axis Communications AB makes no
warranty of any kind with regard to the material contained within this
document, including, but not limited to, the implied warranties of
merchantability and fitness for a particular purpose. Axis Communications
AB shall not be liable nor responsible for incidental or consequential
damages in connection with the furnishing, performance or use of this
material. This product is only to be used for its intended purpose.
Notice
Axis’ policy is to improve its products as new technology, components,
software, and firmware become available. Axis, therefore, reserves the right
to change specifications without prior notice.
Equipment Modifications
This equipment must be installed and used in strict accordance with the
instructions given in the user documentation. This equipment contains no
user-serviceable components. Unauthorized equipment changes or
modifications will invalidate all applicable regulatory certifications and
approvals.
Safety
This product complies with IEC/EN/UL 60950-1 and IEC/EN/EN 60950-22
Safety of Information Technology Equipment.
Contact Information
Axis Communications AB
Emdalavägen 14
223 69 Lund
Sweden
Tel: +46 46 272 18 00
Fax: +46 46 13 61 30
www.axis.com
Disposal and Recycling
When this product has reached the end of its useful life, dispose of it
according to local raws and regulations. For information about your nearest
designated collection point, contact your local authority responsible for
waste disposal. In accordance with local legislation, penalties may be
applicable for incorrect disposal of this waste.
This symbol means that the product shall not be disposed of
together with household or commercial waste. Directive
2012/19/EU on waste electrical and electronic equipment
(WEEE) is applicable in the European Union member states. To
prevent potential harm to human health and the environment,
the product must be disposed of in an approved and
environmentally safe recycling process. For information about your nearest
designated collection point, contact your local authority responsible for
waste disposal. Businesses should contact the product supplier for
information about how to dispose of this product correctly.
This product complies with the requirements of Directive 2011/65/EU on
the restriction of the use of certain hazardous substances in electrical and
electronic equipment (RoHS).
This product complies with the requirements of the legislative act
Administration on the Control of Pollution Caused by Electronic
Information Products (ACPEIP).
Support
Should you require any technical assistance, please contact your Axis
reseller. If your questions cannot be answered immediately, your reseller
will forward your queries through the appropriate channels to ensure a
rapid response. If you are connected to the Internet, you can:
• download user documentation and software updates
• find answers to resolved problems in the FAQ database. Search by
product, category, or phrase
• report problems to Axis support staff by logging in to your private
support area
• chat with Axis support staff (selected countries only)
• visit Axis Support at www.axis.com/techsup
AXIS A8004 Junction Box Installation Guide Page 7
1x 4x
Page 8 AXIS A8004 Junction Box Installation Guide
9
XX 12
26 mm
≥1 in
≥ 9 mm
≥ 1/4 in
- ≤ 26 mm
- ≤ 1 in
ø28 mm (1 1/8 in)
ø22 mm (7/8 in)
AXIS A8004 Junction Box Installation Guide Page 9
1.53 m (5 ft 2/8 in)
117 mm
(4 5/8 in)
221 mm
(8 3/4 in)
1
1.55 m (5 ft 1 1/8 in)
0.5 m (1 ft 7 5/8 in)
1.9 m (6 ft 2 3/4 in)
1.1 m (3 ft 7 in)
≥ 9 mm
≥ 1/4 in
- ≤ 26 mm
- ≤ 1 in
Page 10 AXIS A8004 Junction Box Installation Guide
2
3
AXIS A8004 Junction Box Installation Guide Page 11
~30 cm (12 in)
T10
4x
15
4
5
0.3 Nm
(0.22 lb ft)
Page 12 AXIS A8004 Junction Box Installation Guide
1.53 m (5 ft 2/8 in)
1.55 m (5 ft 1 1/8 in)
0.5 m (1 ft 7 5/8 in)
≥ 26 mm
≥ 1 in
1
117 mm
(4 5/8 in)
221 mm
(8 3/4 in)
1.9 m (6 ft 2 3/4 in)
1.1 m (3 ft 7 in)
AXIS A8004 Junction Box Installation Guide Page 13
2
3
Page 14 AXIS A8004 Junction Box Installation Guide
15
30 cm (12 in)
4
5
AXIS A8004 Junction Box Installation Guide Page 15
4x
T10
1
2
Page 16 AXIS A8004 Junction Box Installation Guide
IP 66
IP 66
3
AXIS A8004 Junction Box Installation Guide Page 17
4
Page 18 AXIS A8004 Junction Box Installation Guide
5
AXIS A8004 Junction Box Installation Guide Page 19
6
Page 20 AXIS A8004 Junction Box Installation Guide
7
A8004-VE
Installation
Guide
AXIS A8004 Junction Box Installation Guide Page 21
4x
T10
8
9
0.8 Nm
(0.6 lb ft)
Page 22 AXIS A8004 Junction Box Installation Guide
4x
10
11
T20
1.5 Nm
(1.1 lb ft)
AXIS A8004 Junction Box Installation Guide Page 23
4x
1.5 Nm
(1.1 lb ft)
TR20
12
Page 24 AXIS A8004 Junction Box Installation Guide
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22

Axis A8004-VE User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI