Axis T8331 User manual

Category
Motion detectors
Type
User manual

This manual is also suitable for

Axis T8331 is a versatile PIR (passive infrared) motion detector designed for indoor and outdoor use. It features intelligent motion detection capabilities, allowing you to customize sensitivity, detection area, and pulse count settings to suit various scenarios. The masking strip option enables you to exclude unwanted detection zones, ensuring accurate motion detection. Additionally, the day/night mode adjustment optimizes the detector's performance in different lighting conditions.

Axis T8331 is a versatile PIR (passive infrared) motion detector designed for indoor and outdoor use. It features intelligent motion detection capabilities, allowing you to customize sensitivity, detection area, and pulse count settings to suit various scenarios. The masking strip option enables you to exclude unwanted detection zones, ensuring accurate motion detection. Additionally, the day/night mode adjustment optimizes the detector's performance in different lighting conditions.

AXIST8331PIRMotionDetectorSeries
UserManual
AboutthisDocument
ThismanualisintendedforadministratorsandusersofAXIST8331PIR
MotionDetectorSeries.Itincludesinstructionsforusingandmanaging
theproductonyournetwork.Laterversionsofthisdocumentwillbe
postedatwww.axis.com
LegalConsiderations
Videoandaudiosurveillancecanberegulatedbylawsthatvaryfrom
countrytocountry.Checkthelawsinyourlocalregionbeforeusing
thisproductforsurveillancepurposes.
Liability
Everycarehasbeentakeninthepreparationofthisdocument.Please
informyourlocalAxisofceofanyinaccuraciesoromissions.Axis
CommunicationsABcannotbeheldresponsibleforanytechnicalor
typographicalerrorsandreservestherighttomakechangestothe
productandmanualswithoutpriornotice.AxisCommunicationsAB
makesnowarrantyofanykindwithregardtothematerialcontained
withinthisdocument,including,butnotlimitedto,theimplied
warrantiesofmerchantabilityandtnessforaparticularpurpose.Axis
CommunicationsABshallnotbeliablenorresponsibleforincidentalor
consequentialdamagesinconnectionwiththefurnishing,performance
oruseofthismaterial.Thisproductisonlytobeusedforitsintended
purpose.
IntellectualPropertyRights
AxisABhasintellectualpropertyrightsrelatingtotechnologyembodied
intheproductdescribedinthisdocument.Inparticular,andwithout
limitation,theseintellectualpropertyrightsmayincludeoneormore
ofthepatentslistedatwww.axis.com/patent.htmandoneormore
additionalpatentsorpendingpatentapplicationsintheUSandother
countries.
EquipmentModications
Thisequipmentmustbeinstalledandusedinstrictaccordancewiththe
instructionsgivenintheuserdocumentation.Thisequipmentcontains
nouser-serviceablecomponents.Unauthorizedequipmentchangesor
modicationswillinvalidateallapplicableregulatorycertications
andapprovals.
TrademarkAcknowledgments
AXISCOMMUNICATIONS,AXIS,ETRAX,ARTPECandVAPIXare
registeredtrademarksortrademarkapplicationsofAxisABinvarious
jurisdictions.Allothercompanynamesandproductsaretrademarksor
registeredtrademarksoftheirrespectivecompanies.
DisposalandRecycling
Whenthisproducthasreachedtheendofitsusefullife,disposeof
itaccordingtolocallawsandregulations.Forinformationabout
yournearestdesignatedcollectionpoint,contactyourlocalauthority
responsibleforwastedisposal.Inaccordancewithlocallegislation,
penaltiesmaybeapplicableforincorrectdisposalofthiswaste.
Europe
Thissymbolmeansthattheproductshallnotbedisposedof
togetherwithhouseholdorcommercialwaste.Directive2012/19/EU
onwasteelectricalandelectronicequipment(WEEE)isapplicablein
theEuropeanUnionmemberstates.Topreventpotentialharmto
humanhealthandtheenvironment,theproductmustbedisposed
ofinanapprovedandenvironmentallysaferecyclingprocess.For
informationaboutyournearestdesignatedcollectionpoint,contact
yourlocalauthorityresponsibleforwastedisposal.Businessesshould
contacttheproductsupplierforinformationabouthowtodispose
ofthisproductcorrectly.
ThisproductcomplieswiththerequirementsofDirective2011/65/EUon
therestrictionoftheuseofcertainhazardoussubstancesinelectrical
andelectronicequipment(RoHS).
China
Thisproductcomplieswiththerequirementsofthelegislative
actAdministrationontheControlofPollutionCausedbyElectronic
InformationProducts(ACPEIP).
ContactInformation
AxisCommunicationsAB
Emdalavägen14
22369Lund
Sweden
Tel:+46462721800
Fax:+4646136130
www.axis.com
Support
Shouldyourequireanytechnicalassistance,pleasecontactyourAxis
reseller.Ifyourquestionscannotbeansweredimmediately,your
resellerwillforwardyourqueriesthroughtheappropriatechannelsto
ensurearapidresponse.IfyouareconnectedtotheInternet,youcan:
ndanswerstoresolvedproblemsintheFAQdatabase.Search
byproduct,category,orphrase
reportproblemstoAxissupportstaffbyloggingintoyourprivate
supportarea
chatwithAxissupportstaff
visitAxisSupportatwww.axis.com/techsup/
LearnMore!
VisitAxislearningcenterwww.axis.com/academy/forusefultrainings,
webinars,tutorialsandguides.
AXIST8331PIRMotionDetectorSeries
TableofContents
Functions..................................................4
I/OandEventConguration.......................................4
WalkTest......................................................4
MaskingStrips..................................................5
Day/NightModeAdjustment......................................5
LEDswitch.....................................................5
PulseCountSwitch..............................................5
SensitivitySwitch...............................................6
DetectionAreaAdjustment........................................6
VMDandPIR...................................................6
ReferenceMaterial..........................................8
HardwareOverview..............................................8
AXIST8331PIRMotionDetectorSeriesGraphs.......................9
AXIST8331PIRMotionDetectorSeriesTerminalConnections............10
AXIST8331PIRMotionDetectorSeriesSchematics....................11
3
AXIST8331PIRMotionDetectorSeries
Functions
Functions
I/OandEventConguration
BelowtextappliestobothAXIST8331andAXIST8331-E.
ThissectioncontainsinformationofI/OcongurationandEventsontheCamera.Formoreinformationandspecicationsaboutthe
productsI/OandEventfunctionalityseetheproductsUserManualavailableonwww.axis.com
I/OPortConguration
1.GotoSetupSystemOptionsPorts&DevicesI/OPorts
2.Setport1toInput(default)
3.SetNormalstateistoGroundedcircuit
4.PressSave
Note
Iftheportisusedinanevent,itisnotpossibletoswitchbetweenInputandOutputuntiltheeventischangedorremoved.
ItisonlypossibletomanuallysetInputorOutputifthecameraprovidestwoormorecongurableI/Oports.
EventConguration
1.GototheEventssetuppageandselectActionRules.
2.SelectAdd.
3.TypeinanamefortheActionRule.
4.SelectInputSignalfromtheTriggerdrop-downlist.
-SelectDigitalInputPortfromthedrop-downlistbelow.
-Select1or2fromthedrop-downlistbelow.
-MakesureActive:issettoYes.
5.SelectavaluefromtheScheduledrop-downlist(Alwaysisselectedbydefault)ormanuallysetavaluebyselect
Newschedule.
6.SelectanactionfromtheTypedrop-downlist.
7.PressOKinordertosavetheActionRule
TheActionRulewillnowbeinthelistofActionRules.
WalkTest
ItisrecommendedtoperformawalktestafterinstallationtoconrmthatthePIRsensorisworkingproperly.
Beforethetest,makesurethePIRsensorisconguredasbelow:
SetthephotocelltoDAY(defaultsetting).
SetthePulsecountswitchtoTEST.
SettheLEDswitchtoON(defaultsetting).ThisappliestoAXIST8331only.
Afterthewarmupperiodiscompleted(approximately60s),conductawalktestbymovinginthedetectionzoneofthePIRsensor.
TheLEDlightswhenthePIRsensordetectsamovingobject.
4
AXIST8331PIRMotionDetectorSeries
Functions
Afterthetest,congurethePIRsensorasbelow:
Setthephotocellaccordingtotheenvironment,DAYisthedefaultsettingandisrecommendedformostapplications.
SetthePulsecountswitchto2.
SettheLEDswitchtoONorOFF.SeeLEDswitchonpage5formoreinformationabouttheLED.Thisappliesto
AXIST8331only.
MaskingStrips
BelowtextappliestoAXIST8331–Eonly.
Unwanteddetectionzonescanbeeliminatedbymaskingthelenswithprovidedmaskingstrips.
1.Removethecover.
2.Applythemaskingstriptothezonesthatshouldbeexcluded.
e
f
f
d
c
b
a
b
c
d
e
e
f
f
d
c
b
a
b
c
d
e
a
b
b
c
c
d
d
e
e
a
b
c
cd
e
f
Day/NightModeAdjustment
BelowtextappliestoAXIST8331–Eonly.
TheDay/NightModeswitchcanbeusedtoadjustthedetectoraccordingtothebrightnessofthesurroundingarea.
ForbestperformanceitisrecommendedtosetthedialtoDAY(defaultsetting).
Tohavethedetectorbegintofunctiononlyafterithasbecomedark,turnthedialgraduallytotheNIGHTside.
ForpositionoftheDay/NightModeswitch,seeHardwareOverviewonpage8
NIGHT DAY
LEDswitch
BelowtextappliestoAXIST8331only.
ForAXIST8331itispossibletosettheLEDswitchtoOFF/ON.BydefaulttheswitchissettoON.WheninthismodetheLEDwilllit
whentriggered.WhensettoOFFtheLEDwillnotbelitwhentriggered.
ForpositionoftheLEDswitch,seeHardwareOverviewonpage8
PulseCountSwitch
BelowtextappliestobothAXIST8331andAXIST8331-E.
5
AXIST8331PIRMotionDetectorSeries
Functions
ThePulseCountswitchcanbesetintwodifferentmodes,2orTEST.Mode2isthedefaultmodeandisrecommendedtouse.
TESTisonlyusedwhenperformingawalktest.
ForpositionofthePulseCountswitch,seeHardwareOverviewonpage8
SensitivitySwitch
TheSensitivityswitchcanbeusedtoadjustthesensitivityofthedetector.Therearethreedifferentmodes.
M(Medium)Thisisthedefaultpositionandcanbeusedfornormalapplications.
H(High)Usethiswhentheapplicationrequireshighsensitivity.WhenusingAXIST8331–EinPetAlleyAreamode,itis
recommendedtosetthesensitivitymodetoH.
L(Low)Usethisinapplicationsthatmaybeunstable.
ForpositionoftheSensitivityswitch,seeHardwareOverviewonpage8
DetectionAreaAdjustment
BelowtextappliestoAXIST8331–Eonly.
ForAXIST8331–Eitispossibletosetthedetectionarea.Therearetwodifferentmodes.
Multi-LevelArea.Thisisthedefaultmodeandisapplicabletonormalapplications.
PetAlleyArea.Thismodeprovidesahorizontaldetectionpatternwithnodeclinationofzones,allowingpetstomove
throughthearea.
Note
IdealmountingheightforPetAlleyAreais1.2mto1.5m.
SeeAXIST8331PIRMotionDetectorSeriesGraphsonpage9forgraphsofMulti-LevelAreaandPetAlleyArea.
SeeHardwareOverviewonpage8forpositionoftheDetectionAreascrewandthemirror.
SeebelowforhowtoswitchtoPetAlleyAreamode.
1.Carefullyloosentheadjustmentscrew.
2.SlidethecoverdownandfastenthescrewatthePposition.
3.Flipthemirrortotheupperposition.
VMDandPIR
AXISVideoMotionDetection(VMD)isanapplicationforAxiscameraproducts.VMDcanbeusedtogetherwiththePIRsensor.The
applicationdetectsmovingobjectswithinapredenedareaofinterest,makingitpossibletoautomaticallytriggeranevent.
6
AXIST8331PIRMotionDetectorSeries
Functions
Note
TheVMDdetectionareaandthePIRsensorsdetectionpatternarenotsynchronizedbydefault.VMDdetectionareacanbe
setinauserinterface.ThedetectionpatternforAXIST8331–Ecanbemodiedbyusingthesuppliedmaskingstrips.
FormoreinformationaboutAXISVideoMotionDetection,seetheproductsUserManualavailableonwww.axis.com
7
AXIST8331PIRMotionDetectorSeries
ReferenceMaterial
ReferenceMaterial
HardwareOverview
AXIST8331
1
SENS
L M H
OFF ON
LED
4
3
2
6
7
5
1
I/Ointerface
2
Terminals
3
PIRsensor(donottouch)
4
Sensitivityswitch
5
Tamperswitch
6
LEDswitch
7
LED
AXIST8331–E
8
AXIST8331PIRMotionDetectorSeries
ReferenceMaterial
7
10
9
11
3
2
4
5
1
6
8
1
Day/Nightmodeadjustment
2
Mirror
3
Photocell
4
LED
5
Detectionareaadjustmentscrew
6
I/Ointerface
7
Pulsecountswitch
8
Tamperswitch
9
PIRsensor(donottouch)
10
Sensitivityswitch
11
Terminals
AXIST8331PIRMotionDetectorSeriesGraphs
AXIST8331graph
9
AXIST8331PIRMotionDetectorSeries
ReferenceMaterial
Thelargegraphaboveshowsatopviewofthedetectionzones.
ThesmallgraphaboveshowsasideviewofthedetectionzoneswhenthePIRsensorismountedonaheightof2.4m.Idealmounting
heightisbetween1.5mto2.4m.
AXIST8331–Egraph
1
2
2.5
8.3 ft
5 ft
1
2
2.5
8.3 ft
5 ft
Thelargegraphaboveshowsatopviewofthedetectionzones.
Thesmallgraphsaboveshowsasideviewofthedetectionzones.Multi-levelareaandPetalleyarea.
AXIST8331PIRMotionDetectorSeriesTerminalConnections
AXIST8331
BelowareimagesoftheterminalconnectionforAXIST8331.
Theleftimageshowsthedefaultconnectionwithtamperandalarmtogether.
Therightimageshowsaconnectionwithtamperandalarmseparated.Thisconnectionrequiresacamerawithatleasttwo
congurableI/Oports.
AXIS T8331
Forpositionoftheterminals,seeHardwareOverviewonpage8
AXIST8331–E
BelowareimagesoftheterminalconnectionforAXIST8331–E.
Theleftimageshowsthedefaultconnectionwithtamperandalarmtogether.
10
AXIST8331PIRMotionDetectorSeries
ReferenceMaterial
Therightimageshowsaconnectionwithtamperandalarmseparated.Thisconnectionrequiresacamerawithatleasttwo
congurableI/Oports.
AXIS T8331-E
Forpositionoftheterminals,seeHardwareOverviewonpage8
AXIST8331PIRMotionDetectorSeriesSchematics
BelowisaschematicshowingtheconnectionwithacameraandthePIRsensor.Thisisthedefaultconnectionwithtamperand
alarmtogether(Pin3).Pin1GND,Pin2Power,Pin4notused.
1
2
3
4
PIRCamera
1. GND
2. Power
3. I/O con gured as input
4. Not use d
Sup ply of PIR
PIR Alarm N.C.
Tampering Switch N.C.
BelowisaschematicshowingtheconnectionwithacameraandthePIRsensor.Inthisconnectiontamperandalarmareseparated.
Pin3alarm,Pin4tamper.Pin1GND,Pin2Power.
11
AXIST8331PIRMotionDetectorSeries
ReferenceMaterial
1
2
3
4
PIRCamera
1. GND
2. Power
3. I/O con gured as input
4. I/O con gured as input
Sup ply of PIR
PIR Alarm N.C.
Tampering Switch N.C.
Note
ThisconnectionrequiresacamerawithatleasttwocongurableI/Oports.
Thisconnectionrequireschangesintheterminal,seeAXIST8331PIRMotionDetectorSeriesTerminalConnectionsonpage10
12
UserManualVer.M1.13
AXIST8331PIRMotionDetectorSeries
Date:November2015
©AxisCommunicationsAB,2015
PartNo.1518265
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13

Axis T8331 User manual

Category
Motion detectors
Type
User manual
This manual is also suitable for

Axis T8331 is a versatile PIR (passive infrared) motion detector designed for indoor and outdoor use. It features intelligent motion detection capabilities, allowing you to customize sensitivity, detection area, and pulse count settings to suit various scenarios. The masking strip option enables you to exclude unwanted detection zones, ensuring accurate motion detection. Additionally, the day/night mode adjustment optimizes the detector's performance in different lighting conditions.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI