AD network video ©2011
16
TransVu
Cameras Menus
The Camera Menus are the conguration pages directly associated with the video inputs. These allow the
camera inputs to be enabled, identify image resolution, set record rates, etc.
Function Description
Pics Per Second (pps) / milliseconds (ms)
This allows the record settings to be congured as either Pictures Per
Second or Milliseconds.
Live/Record Resolution This is the resolution of the live and recorded images that will be
transmitted from the TransVu and recorded to hard disk.
PAL Fields 640 x 256, 720 x 256, 768 x 288, 720 x 288
NTSC Fields 640 x 240, 720 x 240.
Interlace Enabling this option will apply interlace to the video images.
High This is the maximum le size for the images when high quality video has
been selected to be recorded or viewed.
The unit records images at the high resolution settings as standard.
Medium This is the maximum le size for the images when medium quality video
has been selected to be viewed.
Low This is the maximum le size for the images when low quality video has
been selected to be viewed.
Camera Set-up The camera set-up page allows global settings and individual camera
settings to be congured.
Note: TransVu is physically congured for seven camera operation. Camera input eight is now set up as
a spot monitor input. The Spot Monitor is an analogue output capable of full screen or full screen
sequence with a programmable dwell time.
Note: Reducing the le size will allow more data to be transmitted across the network, it is important to
remember reducing the le size will require the compression applied to be increased and this will
affect the quality of the image.
Function Description
Advanced Setup This option gives access to the conguration page to allow alias
conguration for the MPEG4 mode, refer to the Advanced Setup section
below.
Video Expiry Period This indicates the maximum time any images can be stored on the
hard disk, if the record duration is less than the video expiry period the
images will automatically be overwritten.
Spot Monitor Dwell Time The unit supports an option Spot monitor output where a single or a
sequence of cameras can be viewed full screen. If a sequence is to be
displayed identify the time period each image is to be displayed on the
monitor.
Record Duration The total record time available in (DD) Days and (HH) Hours. This
indicates the storage capacity of the system without any alarm
recording. This is estimated from size of video storage, the standard
record rate and the requested target size of the recorded images.
Note: Changing the Record Duration will automatically update the Standard Record Rate. Changing the
Standard Record Rate will likewise update the Record Rate.