Danfoss VACON CX (Legacy Product) is a versatile and user-friendly AC drive that provides precise motor control for a wide range of applications. With its intuitive graphical control panel, you can easily monitor and adjust drive settings, view real-time data, and troubleshoot faults. The VACON CX is also equipped with a variety of built-in features, including:
- Multiple control modes: Choose from a variety of control modes, including V/Hz control, vector control, and torque control, to optimize performance for your specific application.
- Extensive I/O options: Connect to a variety of sensors and devices with the VACON CX's built-in I/O, including digital inputs and outputs, analog inputs and outputs, and relay outputs.
VACON CX/CXL/CXS Graphical control panel Page 2
_______________________________________________________________________
1. General
Panel Ready
3 Motor Current
3.4AA
= the mains voltage has been
and the drive is ready to operate
Start the motor if the panel is the
Stop the motor if the panel is the
Motor run/stop and direction state
= Sign of the selected item
= Symbol when up arrow pushed
= Symbol when down arrow pushed
= Symbol when enter pushed
DOWN
-
ENTER
••
START
¡¡
STOP
+
UP
+
UP
DOWN
-
ENTER
••
START
¡¡
STOP
Figure 1. Graphical control panel with LCD display.
VACON CX/CXL/CXS Graphical control panel Page 3
_______________________________________________________________________
_______________________________________________________________________________________
Vacon Plc Phone: +358-201 2121 Fax: +358-201 212 205
http://www.vacon.com
2. Page menu
Figure 2. Menu.
3. Monitoring page
Figure 3. Monitoring signals (reachable from menu page or -button).
MONIT
AA
Panel Ready
2 Motor Speed
637
Panel Ready
rpm
Signal name
Signal value
Status field
Signal value bar
Next signal
Previous signal
DOWN
-
+
UP
Monitor......MON
Operate......OPR
Parameter....PAR
Actual Values...
Trend...........
Active Faults...
Fault History...
Contrast........
Page names
Open the
selected page
Scroll mark,
more pages
â
ENTER
VACON CX/CXL/CXS Graphical control panel Page 4
_______________________________________________________________________
_______________________________________________________________________________________
Vacon Plc Phone: +358-201 2121 Fax: +358-201 212 205
http://www.vacon.com
4. Operating page
Figure 4. Reference value setting and virtual button
(reachable from menu page or -button.
5. Parameter page
Figure 4. Parameter value setting.
Panel Ready
1 Basic Parameters
2 Max. Frequency
50.00 Hz
0.00 120.00
Parameter group
Parameter name
Parameter value
(number or text)
Parameter limits
(omitted if value is text)
Next group
Previous group
Next parameter
Previous parameter
Increment value
Decrement value
Confirm
parameter value
Status field
Parameter value bar
(omit if value is text)
Functions of push-buttons
depend on selected item
Functions of push-buttons depend
on every selected item
+
UP
DOWN
-
DOWN
-
+
UP
DOWN
-
+
UP
ENTER
Panel Ready
1 Freq. reference
23.45 Hz
Reverse
á
Panel Control
Clr MWh Counte
â
Reference name
Reference value
Virtual button
name
Status field
Virtual button field
Scroll mark if there
are more buttons
Virtual button
state
Next reference
Previous
reference
Increment
reference
Decrement
reference
Push the virtual
button
Functions of push-buttons
depend on selected item
Scroll virtual button
field, if there is
á
mark
Scroll virtual button
field, if there is
â
mark
Reference mark
t
and actual value bar
DOWN
-
+
UP
DOWN
-
+
UP
ENTER
VACON CX/CXL/CXS Graphical control panel Page 5
_______________________________________________________________________
_______________________________________________________________________________________
Vacon Plc Phone: +358-201 2121 Fax: +358-201 212 205
http://www.vacon.com
6. Actual values page
Figure 6. Actual value signals monitoring.
7. Trend page
Figure 7. Trend of the signals.
Panel Ready
1 Output Frequency
21.25 Hz
2 Motor Speed
637 rpm
3 Motor Current
3.4 A Signal value
Status field
Next signal
Previous signal
Functions of push-buttons
depend on selected item
Signal name
Signal value
Signal value
Signal name
Signal name
DOWN
-
+
UP
1 Output Frequency
00:12:34,0 s
20.75 Hz
Ch 1
Menu
Marker
Toggle
run/stop trend
Signal name
Run/stop state
Channel number
Open trend
menu page
Next channel
Previous
channel
Move marker
to the right
Move marker
to the left
Signal value
on the position
of the marker
Time
on the position
of the marker
Functions of push-buttons
depend on selected item
DOWN
-
+
UP
DOWN
-
+
UP
ENTER
ENTER
VACON CX/CXL/CXS Graphical control panel Page 6
_______________________________________________________________________
_______________________________________________________________________________________
Vacon Plc Phone: +358-201 2121 Fax: +358-201 212 205
http://www.vacon.com
8. Trend menu page
Figure 8. Connect trend signals and change scale of the signal.
9. Active fault page
Figure 9. Active fault display.
Active faults
F Overcurrent
F Overvoltage
F Earth fault
Reset faults
Fault name
F = sign of the fault
A = sign of the alarm
Reset faults
ENTER
Clear Menu
1 Output Frequency
0.00 Hz
50.00 Hz
Min
Max
Time
Channel 1
00:22:30 s
Signal name
Length of the
time axis
Maximum of
the value axis
Minimum of
the value axis
Connect next signal
to the selected channel
Connect previous signal
to the selected channel
Next channel
Previous channel
Increment the min.
of the value axis
Decrement the min.
of the value axis
Open trend page
Functions of push-butto ns
depend on selected item
Functions of push-buttons depend
on every selected item
( not on Clear Menu item)
Increment the max.
of the value axis
Decrement the max.
of the value axis
Channel number
Increment the length
of the time axis
Decrement the length
of the time axis
Confirm the changes
DOWN
-
+
UP
DOWN
-
+
UP
DOWN
-
+
UP
DOWN
-
+
UP
DOWN
-
+
UP
ENTER
ENTER
VACON CX/CXL/CXS Graphical control panel Page 7
_______________________________________________________________________
_______________________________________________________________________________________
Vacon Plc Phone: +358-201 2121 Fax: +358-201 212 205
http://www.vacon.com
10. Fault history page
Figure 10. Fault history display.
11. Contrast page
Figure 11. Adjust contrast.
Contrast
s
Light
Lighten the display
t
Dark
Darken the display
SMG001G
Version of the
panel program
DOWN
-
+
UP
Fault history
1 Overcurrent
Motor Current
14.5 A
2 Overvoltage
Output Frequency
23.56 Hz
Reset history
Signal in history,
only 3 latest faults
have signal history
Signal value
in history
Fault name
Scroll up
history field
Scroll down
history field
Ordinal number
of the fault
(1 = the latest)
Next signal
Previous
signal
Reset history by
pushing 2 seconds
Functions of push-buttons
depend on selected item
DOWN
-
+
UP
DOWN
-
+
UP
ENTER
VACON CX/CXL/CXS Graphical control panel Page 8
_______________________________________________________________________
_______________________________________________________________________________________
Vacon Plc Phone: +358-201 2121 Fax: +358-201 212 205
http://www.vacon.com
12. Info/Files page
Figure 12. Software information and loading software to the option card.
smfa001d
Option: ---
smfa001d
Option: CX100 OPT I/O
1
AA2,2CX4B21A
Loaded files:
sm00040a
smfa001d
smib001a (option)
smmb005c (option)
Option: InterBusS
smib001a
Unit nominal power [kW] 4=400V, 5=500V, 6=690V
System software
Loaded application
Software 1 for option card
Software 2 for option card
Option with uP
Option without uP
No option
Option name
Option card
Status of the option
Software in the option
Next software
Previous software
Load software
to the option
smmb005c
DOWN
-
+
UP
ENTER