Assa Abloy ENA-BX User manual

Category
Sirens
Type
User manual

This manual is also suitable for

Wirefree Yale ENA-BX
External Siren
Feature:
1. Learn button
2. Tamper Spring
3. Power On/Off switch
4. Dip Switch Block
5. Strobe Lights
6. Sounder
7. Siren fixing holes (x4)
8. Battery compartment screws (x4)
9. DC power terminal block
10. Strobe window
11. Lid fixing screw
Pack content:
1x External Siren
4x Screws
4x Wall Plug
Dip Switch (SW) function table
Dip SW 1 Clear Siren memory
ON Clear
OFF Normal (Default)
Dip SW 2 Interference detection
ON Enable
OFF Disable (Default)
Dip SW 3 Supervision
ON Enable
OFF Disable
Dip SW 4 Function not used. Dip switch
must be in the off position.
Notes:
• DonotslidealltheswitchestotheON
positionsimultaneously.Doitoneata
time.
• Ifsupervisionisenabledinthecontrolpanel,
DipSw3mustbeturnedOn(Enable)orelse
the“SupervisionFail”faultwillbeshown.
11
10
1
ON
ON
OFF
ON
1 2 3 4
2
3
4
5
6
7
8
9
SmartHome Alarm series
Programming
Step 1.Removethesirenfrontcover.
Step 2.MakesuretheDipSwitch#4issettothe
OFFposition.Alsosetthepowerswitchofthesiren
totheONposition.
Step 3.LogintotheControlPanel’sEngineering
menu.Select“ZoneSettings”->“ZoneCong”->
“AddZone”.PressOKandtheLCDoftheControl
Panelwilldisplay“*Pushbuttonon*Devicetoadd”.
Step 4.Press&holdthesiren’sLearnbuttonfor1
second.Thesirenwillbeeponce,withtheLED#1
(Left)andLED#3(Right)ashingoncetoindicate
the“learnsignal”hasbeentransmitted.
NOTE
ToexitLearnMode:PresstheLearnbuttonagain,
or,Sirenwillautomaticallyexitafter3minutes
(time-out).ThesirenwillbeeponceandtheLED#2
(Middle)willashoncetoindicatethishadtaken
place.
Step 5.Ifsuccessfullyreceived,theControlPanel
willdisplay“Detected(OK?)”.PressOKtoconrm
thelearning.Thecontrolpanelwillnowsendalearn
acknowledgementtothesiren.
Step 6.OncethesirenreceivestheLearn
acknowledgementfromtheControlPanel,itwill
emitashortbeepwithLED#2ashingonceto
indicatethatthesirenhasbeensuccessfullyadded
intothesystem.Youcannowproceedtosetup
parametersforthesiren(Pleasewaitforatleast7
secondsbeforeproceeding).
Step 7. Toprogramsirenparameters,pressthe
“Return”buttonontheControlPaneltoreturnto
theroot.Select“ZoneSettings”->“ZoneCong”->
“EditExt.Siren”option.
The following settings are applied to all sirens in
the system:
“Siren Length”
Press ortoincreaseordecreasethesiren
lengthfromDisableor1to30minutes(at1minute
increments).PressOKtoselect,thesirenwillbeep
oncetoindicateconrmation.
“Siren Offset”
AdjustthelengthofSilentDelayonsirenringing
afteranalarmeventisdetected.Thisallowsthe
controlpaneltoreporttheeventinsilencevia
telephonepriortoaloudalarmevent.Press
ortoincreaseordecreasethesirendelaytime
fromDisableor10to60seconds(at10second
increments).
“Confirm Sound”
Notifyusersofthesystemstatusviasirenbeeps.One
beepforarmandtwobeepsfordisarm.SelectEnable
orDisabletoenableordisablethisfunction.
“Entry Sound”
Notifyusersoftheentrycountdownviasirenbeeps.
SelectEnableorDisabletoenableordisablethis
function.
“Siren Tamper”
Oncethetamperprotectionisdisabled,thesirenwill
automaticallyreverttoenableafteranhour(ifuserhas
notalreadyenableditmanually).
“Comfort LED”
Controlthesiren’sLEDashintervalduringnon-
alarmmode.Pressortoincreaseordecrease
theashintervaltimefromDisableor5,10to60
seconds(at10secondsincrements).Pleasenotethat
enablingthisfeaturewilldecreasethesiren’sbattery
life.
Step 8:Tondthebestinstallationlocationforthe
sirenyouwillneedtousethe“walktest”option.
Accessthisoptionfrom“Testing”->“WalkTest”.
Step 9:Holdthesireninthedesiredlocation,press
theTest/Learnbuttontoconrmifthislocationis
withinradiosignalrangeoftheControlPanel.The
RSSIsignalstrengthvaluewillbedisplayedonthe
controlpanel,rangingfrom0~9(9indicatesthebest
signalstrengthperformance).Donotinstallsireninan
areawheretheRSSIvalueislessthan5.
Step 10.Keeppressingthe“Return”keytoexit
programmingmenuinthecontrolpanel.TheLEDswill
ash2fullcyclestoindicatethattheuserhasexited
theprogrammingmenusuccessfullyandthatthe
systemisinStandbymode.
Step 11.Theparametersareallsetandthesirenis
readytobemounted.
Mounting
Therearetwotamperspringsonthesiren(please
seeimageontherstpageforTamperlocation).Ifthe
sirenispulledofffromthewalland/orseparatingits
front&backcover,thealarmwillbeactivated.Please
ensureitisfullydepressedwhenthesirenismounted.
Step 1.Disablethesirentamperusingthecontrol
panel.Select“ZoneSettings”->“ZoneCong“->
“EditExt.Siren”->“SirenTamper”.Thisoptionneeds
tobedisabled.
Step 2.Removethesirencover.Usingthescrews
andwallplugsprovided,mountthebaseunitonthe
wallthroughthe4xmountingholes.Carefullyalign
theholeswhendrilling.
Step 3.EnsurethePowerSwitchisswitchedto
theONposition.Replacethesirencover.
Step 4.Enablethesirentamperusingthecontrol
panel.Select“ZoneSettings”->“ZoneCong“
->“EditExt.Siren”->“SirenTamper”.Thisoption
needstobeenabled.
Step 5. Testthesirenbyarminganddisarming
withtheControlPanel.Ifthereare5xsirenbeeps
and3xLEDasheswhilearming,thetamper
spring(s)arenotdepressedproperly.Youmayneed
todisablethesirentamper(Step1)andphysically
adjustthesirenmountingposition.Otherwisethe
installationisnowcompleted.
Operation
Siren Reset
Step 1:SlidethePowerSwitchtoOFFposition.
Step 2:SlideDipSwitch#1toON(rIGHT)
positionthenturnthepowerswitchon.
Step 3:TheLEDswillashfor1cycle.
Step 4:SlidedipSW1backtoOFF(left)
positiontoreturntonormalmode.
Previousalarmwarning
Iftherehasbeenanalarmwhileyouwereaway,
thesirenwillsoundandashfor3seconds
whenthesystemisdisarmed.Pleasebeaware
thattheintrudercouldstillbeinthepremises.
Audio & Visual Status Indication
Siren Audio Strobe light
Arm/Home 1 beep * 3 LED flashes at once
Disarm 2 beeps * Flashes for 1 cycle
Arm (Low Battery) 5 beeps 3 LED flashes for three
times
Disarm (Low Battery) 5 beeps
Sequentially flashes for 2 cycles
Arm (Tamper) 5 beeps 3 LED flashes for three
times
Disarm (Tamper) 2 beeps * Flashes for 2 cycles
* The Siren Audio indication will be affected by the Confirm
Sound. Setting Confirmation to OFF will disable the
confirmation sound.
Siren Audible Performance
Thesirenproducesaminimumof105dBA
soundpressureat1metre.Thesirenduration
dependsontheparameterintheControlPanel.
Burglar/Emergency/TamperAlarm-thesiren
givesacontinuousalarmsoundwithsequential
ashesuntilthepresetsirenlengthcomestoa
stop(default:3minutes).
Firealarm-thesirengivesacontinuousalarm
sound(2-secondonand1-secondoff)with
sequentialashesuntilthepresetsirenlength
(default:3minutes).
Atlowbatterycondition,beepingoccurs
irregularly.
Thesirenissilencedwheneitherthe
programmedsirendurationexpiresorwhenthe
userdisarmthesystem.
Changing Batteries
TheSirenispoweredby4xD-cellAlkaline
batterieswithalifeexpectancyofover3years
duringnormaloperationorbyanoptionalDC
adaptor12V1A.
Inthecentrethereisapowerswitchtoisolate
thebatterycompartment.
Underlowbatteryconditionthesirenwillbeep
5timesduringarminganddisarming.This
indicatesthatthesirenhasenoughpowerto
operateforabout1month.Pleasereplacethe
batteriesimmediately.Thereisnolowbattery
conditionifaDCpoweradaptorisused.
Step 1:Disablethesirentamperasfollows:
Select“ZoneSettings”->“ZoneCong“->
“EditExt.Siren”->“SirenTamper”.
Step 2:Openthesirencover.Slidethepower
switchtoOFFposition.
Step 3. Thebatterycompartmentisalarge
boxinthesirenwithalidsecuredby4screws.
Removetheoldbatteriesandthenpressthe
LearnButtonfor1~2secondstodischarge.
Step 4:Insert4xnewDcellalkalinebatteries
observingthepolarity.Thesirenwillbeepand
ashwhenthelastbatteryisinserted.
Step 5:Replacethebatterycompartmentlid
andthesirencover.
Step 6:Enablethesirentamperasfollows:
Select“ZoneSettings”->“ZoneCong“->
“EditExt.Siren”->“SirenTamper”.
Specication
Environmentalconditions:
-10cto40c,relativehumidity85%non-
condensing.ForOutdoor/Indooruse,
IP44.
Radio
868.35MHzFM
Battery:
4x1.5VDCellAlkalinebattery
Dimension:
257.5mm(diameter)x60.65mm
Standard:
EN300-220-1
EN301489-1,3
EN60950
PD6662:2010Grade2Class3
2 Year Instruction Statement:
Thisproductisguaranteedforconsumers
againstfaultyworkmanship,materialsand
functionforaperiodof2yearsfromthedate
ofpurchaseprovidingthefullinstallationand
maintenanceinstructionsarefollowed.Please
keepyourproofofpurchasesafe,thismust
besubmittedwhenmakingaclaimunderthis
guarantee.
Pleasenotethatitisaconditionofthis
guaranteethatyourYaleproduct:
•Hasbeencorrectlyinstalledandmaintained
inaccordancewiththeYaleinstallationand
maintenanceinstructionsprovidedtoyouat
thetimeofpurchase.
•Hasnotbeenmodiedordamagedinanyway.
•Hasnotbeensubjectedtounauthorized
repairs.
Yaleareresponsibleunderthisguaranteefor
repairingtheproductorreplacingtheproduct
aswedeemnecessary.Ifthereisfaultwiththe
product,pleasecontactCustomerServiceson
01902364647,whowillgiveyouthenameofan
expertandconrmwhatyouneedtodotomake
aclaimunderthisguarantee.
Pleasedonotcarryoutanyrepairswithoutour
authorityorbyusinganunauthorisedexpert.
Anyrepairsorotherworkscarriedoutwithout
ourauthorizationorbyusinganunauthorized
expertwillnotbecoveredunderthisguarantee.
Thisguaranteeisnontransferrableandapplies
toproductspurchasedintheUnitedKingdom
only.Thisguaranteedoesnotapplytonormal
wearandtear.Thisdoesnotaffectyourstatutory
rights.Afullcopyoftheproductinstructionsare
availableuponrequestorbyvisitingourwebsite
www.yale.co.uk.
E2 09/11
RoHS
WEEE
Note:Wasteelectricalproductsand
batteriesshouldnotbedisposedofwith
householdwaste.Pleaserecyclewhere
facilitiesexist.Checkwithyourlocal
authorityorretailerforrecyclingadviceor
logontowww.yale.co.ukfordetails.
The world’s favourite lock
School Street, Willenhall, West Midlands WV13 3PW
www.yale.co.uk T. +44 1902 364647 E. [email protected]
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Assa Abloy ENA-BX User manual

Category
Sirens
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI