Promax OD-606 Reference guide

Type
Reference guide

This manual is also suitable for

Promax OD-606 is a versatile oscilloscope that provides advanced features for precise waveform analysis. Equipped with two channels, each with a bandwidth of 60 MHz, it offers real-time sampling rates of up to 1 GSa/s, enabling the capture of fast and complex signals. Its intuitive user interface and comprehensive range of triggering options, including edge, video, and pulse width triggering, enhance the ease of use and accuracy of measurements.

Promax OD-606 is a versatile oscilloscope that provides advanced features for precise waveform analysis. Equipped with two channels, each with a bandwidth of 60 MHz, it offers real-time sampling rates of up to 1 GSa/s, enabling the capture of fast and complex signals. Its intuitive user interface and comprehensive range of triggering options, including edge, video, and pulse width triggering, enhance the ease of use and accuracy of measurements.

OD-603/606
RIGHT SIDE PANEL
Probe Compensation: Measurement signal (5V/1KHz) output
Display area
2
Power ON/OFF
1
Control (key and knob) area
3
4
Signal Input Channel
6
EXT Trigger Input
5
7
Menu off
FRONT PANEL
1
2
3
4
5
6
7
QUICK REFERENCE GUIDE
8
9
10
12
Find the user's manual on the download area at: www.promaxelectronics.com
11
USB Host port
8
USB Device port
9
COM / VGA port (Optional)
10
Trigger signal output & Pass/Fail output port
11
LAN port
12
CONTROL KEY AREA
REAR PANEL
OD-603/606
13
14
15
16
17
AC power input jack
Fuse
Air vents
14
Handle
13
15
16
Foot stool
17
18
Multipurpose knob
19
Function key area
22
Vertical control area
21
Horizontal control area
20
Trigger control area
23
Menu off
24
Menu option setting (H1-H5)
25
Menu option setting (F1-F5)
QUICK REFERENCE GUIDE
18
19
20
21
22
23
24
25
Waveform Display Area.
1
USER INTERFACE
OD-603/606
QUICK REFERENCE GUIDE
The state of trigger, including:
Auto:
Trig:
Ready:
Scan:
Stop:
2
The purple T pointer indicates the horizontal position for the trigger.
3
The pointer indicates the trigger position in the internal memory.
4
The two yellow dotted lines indicate the size of the viewing
expanded window.
5
It shows present triggering value and displays the site of present
window in internal memory.
6
It shows setting time.
7
It indicates that there is a U disk connecting with the oscilloscope.
8
9
The purple pointer shows the trigger level position for CH1.
10
The positions of two purple dotted line cursors measurements.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
1516
17
18
19
20
21
22
23
Automatic mode and acquire waveform without triggering.
Trigger detected and acquire waveform.
Pre-triggered data captured and ready for a trigger.
Capture and display the waveform continuously.
Data acquisition stopped.
QUICK REFERENCE GUIDE
OD-603/606
PDF
USER MANUAL
DOWNLOAD
Find the user's manual on the download area at:
www.promaxelectronics.com
29-05-2014 (0 DG0149)
v1.0
OD-603/606
The waveform of CH2.
The frequency of the trigger signal of CH1.
It indicates the current function menu.
11
12
13
14
Current trigger type:
Rising edge triggering.
Falling edge triggering.
Video line synchronous triggering.
Video field synchronous triggering.
The reading shows the trigger level value of the corresponding channel.
The reading shows the window time base value.
16
The reading shows the setting of main time base.
17
The readings show current sample rate and the record length.
18
19
The readings indicate the corresponding Voltage Division and the Zero Point positions of the
channels. The icon shows the coupling mode of the channel.
"" indicates direct current coupling.
"~" indicates AC coupling.
" " indicates GND coupling.
20
It is cursor measure window, showing the absolute values and the readings of the two
cursors.
21
The yellow pointer shows the grounding datum point (zero point position) of the waveform
of the CH2 channel. If the pointer is not displayed, it shows that this channel is not opened.
22
The red pointer indicates the grounding datum point (zero point position) of the waveform
of the CH1 channel. If the pointer is not displayed, it shows that the channel is not opened.
23
The waveform of CH1.
15
It indicates the measured type and value of the corresponding channel.
F: Means frequency.
T: Means cycle.
V: Means the average value.
Vp: The peak-peak value.
Vk: The root-mean-square value.
Ma: The maximum amplitude value.
Mi: The minimum amplitude value.
Vt: The Voltage value of the waveform's flat top value.
Vb: The Voltage value of the waveform's flat base.
Va: The amplitude value.
Os: The overshoot value.
Ps: The Preshoot value.
RT: The rise time value.
FT: The fall time value.
PW: The +D width value.
NW: The D Width value.
+D: The +Duty value.
-D: The -Duty value.
PD: The Delay A B value.
ND: The Delay A B value.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Promax OD-606 Reference guide

Type
Reference guide
This manual is also suitable for

Promax OD-606 is a versatile oscilloscope that provides advanced features for precise waveform analysis. Equipped with two channels, each with a bandwidth of 60 MHz, it offers real-time sampling rates of up to 1 GSa/s, enabling the capture of fast and complex signals. Its intuitive user interface and comprehensive range of triggering options, including edge, video, and pulse width triggering, enhance the ease of use and accuracy of measurements.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI