OD-610/620
LEFT AND RIGHT SIDE PANEL
FRONT PANEL
QUICK REFERENCE GUIDE
Find the user's manual on the download area at: www.promaxelectronics.com
Control (key and knob) area
Probe Compensation: Measurement signal (5V/1KHz) output
Display area
2
Power ON/OFF
1
3
4
Signal Input Channel
EXT Trigger Input
6
5
7
Menu off
Power indication-light
8
USB Host port
USB Device port
VGA port
9
10
11
12
AC Power input jack
15
LAN port
Power switch
13
14
Fuse
CONTROL KEY AREA
REAR PANEL
OD-610/620
19
21
22
23
24
Multipurpose knob
Function Key area
25
Vertical control area
26
Horizontal control area
Trigger control area
Menu off
27
Menu option setting (H1-H5)
28
Menu option setting (F1-F5)
QUICK REFERENCE GUIDE
16
17
18
20
Air vents
Handle
17
Trigger signal output & Pass/Fail output port
16
18
19
Foot stool
20
Ground connection
21
22
23
24
25
26
28
27
Waveform Display Area.
1
USER INTERFACE
OD-610/620
QUICK REFERENCE GUIDE
The state of trigger, including:
Auto:
Trig:
Ready:
Scan:
Stop:
2
The purple T pointer indicates the horizontal position for the trigger.
3
The pointer indicates the trigger position in the internal memory.
4
The two yellow dotted lines indicate the size of the viewing expanded window.
5
It shows present triggering value and displays the site of present window in internal
memory.
6
It shows setting time.
7
It indicates that there is a U disk connecting with the oscilloscope.
8
9
The red pointer shows the trigger level position for CH1.
10
9
10
11
13
15
17
18
20
21
22
23
24
25
26
27
3
4
5
6 7
8
1
2
12
14
16
19
Indicating battery power status.
The waveform of CH1.
11
Automatic mode and acquire waveform without triggering.
Trigger detected and acquire waveform.
Pre-triggered data captured and ready for a trigger.
Capture and display the waveform continuously.
Data acquisition stopped.
QUICK REFERENCE GUIDE
OD-610/620
Find the user's manual on the download area at:
www.promaxelectronics.com
09-06-2016 (0 DG0151)
v1.1
OD-610/620
The purple pointer shows the trigger level position for CH2.
The positions of two purple dotted line cursors measurements.
The waveform of CH2.
The frequency of the trigger signal of CH1.
It indicates the current function menu.
12
13
14
15
16
Current trigger type:
Rising edge triggering.
Falling edge triggering.
Video line synchronous triggering.
Video field synchronous triggering.
The reading shows the trigger level value of the corresponding channel.
18
The reading shows the window time base value.
20
The reading shows the setting of main time base.
21
The readings show current sample rate and the record length.
22
It indicates the measured type and value of the corresponding channel. "F" means frequency,
“T" means cycle, "V" means the average value, "Vp" the peak-peak value, "Vk" the
root-mean-square value, "Ma" the maximum amplitude value, "Mi" the minimum amplitude
value, "Vt" the Voltage value of the waveform's flat top value, "Vb" the Voltage value of
the waveform's flat base, "Va" the amplitude value, "Os" the overshoot value, "Ps" the
Preshoot value, "RT" the rise time value, "FT" the fall time value, "PW" the +D width value,
"NW" the D Width value, "+D" the +Duty value, "-D" the -Duty value, "PD" the Delay A B
value and "ND" the Delay A B value.
23
The readings indicate the corresponding Voltage Division and the Zero Point positions of the
channels. The icon shows the coupling mode of the
channel.
"" indicates direct current coupling.
"~" indicates AC coupling.
" " indicates GND coupling.
24
It is cursor measure window, showing the absolute values and the readings of the two cursors.
25
The yellow pointer shows the grounding datum point (zero point position) of the waveform
of the CH2 channel. If the pointer is not displayed, it shows that this channel is not opened.
26
The red pointer indicates the grounding datum point (zero point position) of the waveform
of the CH1 channel. If the pointer is not displayed, it shows that the channel is not opened.
27
The frequency of the trigger signal of CH2.
17
19
USER MANUAL