Promax OL-612 Reference guide

  • Hello! I am an AI chatbot trained to assist you with the Promax OL-612 Reference guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
OL-612
QUICK REFERENCE GUIDE
Find the user’s manual on the download area at: www.promaxelectronics.com
REAR PANEL
FRONT PANEL
2
3
4
8
7
6
1
5
9
13
12
10
11
10
9
11
USB Host port
Ground connection
VGA port
13
12
Handle
AC power input jack
2
1
4
3
6
5
8
7
Oscilloscope signal input
Logic Analyser signal input
USB slot
Power and charging indication
Power on/off
Display area
Control (key and knob) area
Measurement signal output
QUICK REFERENCE GUIDE
OL-612
CONTROL KEY AND KNOB AREA
15
19
16
14
1718
14
Switch Oscilloscope / Logic Analyzer
17
Horizontal control area
Trigger control area
16
15
Function key area
18
Vertical control area
Menu option setting (F1 to F5)
19
QUICK REFERENCE GUIDE
OL-612
3
4
5
6
12
8
20
21
USER INTERFACE
7
9
11
10
121415161819 17
23
22
Waveform Viewing Area.
1
The trigger state indicates the following information:
Auto:
Trig’d:
Ready:
Scan:
Stop:
2
The purple pointer indicates the horizontal trigger position, which can be adjusted by
the horizontal position control knob.
3
The pointer indicates the trigger position in the internal memory.
4
This reading shows the time deviation between the horizontal trigger position
and the window center line, which is regarded as 0 in the window center.
5
It indicates the current function menu.
6
It indicates the operation options for the current function menu, which changes
with the function menus.
7
The purple pointer shows the trigger level position.
8
The oscilloscope is under the Automatic mode and is collecting the
waveform under the non-trigger state
The oscilloscope has already detected a trigger signal and is collecting the
after-triggering information.
All pre-triggered data have been captured and the oscilloscope has been
already ready for accepting a trigger.
The oscilloscope captures and displays the
waveform data continuously
in the scan mode.
The oscilloscope has already stopped the waveformdata acquisition.
13
OL-612
PDF
USER MANUAL
DOWNLOAD
Find the user's manual on the download area at :
www.promaxelectronics.com
04-09-2014 (0 DG0155)
v1.1
OL-612
QUICK REFERENCE GUIDE
The reading shows the trigger source.
It shows the selected trigger type:
Rising edge triggering.
Falling edge triggering.
Video line synchronous triggering.
Video field synchronous triggering.
The reading shows the window time base set value.
The positions of two purple dotted line cursors measurements.
" "
"~"
" "
The reading shows the trigger level value.
The reading shows the main time base set value.
The two yellow dotted lines indicate the size of the viewing expanded window.
The icon shows the coupling mode of the CH2 channel:
Indicates the direct current coupling.
Indicates the AC coupling.
Indicates GND coupling.
The reading shows the vertical scale factor (the Voltage Division) of the CH2 channel.
The icon indicates the coupling mode of the CH1 channel.
" "
"~"
" "
Indicates the direct current coupling.
Indicates the AC coupling.
Indicates GND coupling.
The reading indicates the vertical scale factor (the Voltage Division) of the
CH1 channel.
The information shows the zero point positions of CH1 or CH2 channel.
The yellow pointer shows the grounding datum point (zero point position)
of the waveform of the CH2 channel. If the pointer is not displayed, it shows
that
this channel is not opened.
The red pointer indicates the grounding datum point (zero point position) of the
waveform of the CH1 channel. If the pointer is not displayed, it shows that the
channel is not opened.
The reading shows the frequency of the two channels. It is a 6 digits cymometer.
Its measurement range of frequency is 2 Hz to full bandwidth. When the triggering
mode is edge triggering, it is a one channel cymometer and it can only measure the
frequency of the triggering channel. When the
triggering mode is alternating
triggering, it is a two channel cymometer and it can measure the frequency of
two channels.
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
/