Promax OD-624 Reference guide

Type
Reference guide
OD-624
QUICK REFERENCE GUIDE
FRONT PANEL
Menu off
Foot stood
Power On/Off
Signal Input of 4 Channels
Control (key and knob) area
2
Display area
1
3
4
6
5
7
Probe Compensation: Measurement signal (5 V/1 kHz) output
1
2
3
6
7
5
4
Find the user’s manual on the download area at: www.promaxelectronics.com
OD-624
QUICK REFERENCE GUIDE
8
9
Menu option setting (H1-H5)
CONTROL KEY AREA
15
12
13
9
8
10
G knob (General knob)
11
12
Horizontal control area
Trigger control area
10
Function key area
13
Vertical control area
14
15
Menu off
Menu option setting (F1-F5)
11
14
OD-624
QUICK REFERENCE GUIDE
USER INTERFACE
15
9
3
4
5
6
7
8
1
2
22
23
27
19
13
14
16
17
18
Source
Line
Type
Horizontal
L1
20
21
24
25
26
10
11
12
Waveform Display Area.
1
The state of trigger, including:
Auto:
Trig:
Ready:
Scan:
Stop:
T pointer indicates the horizontal position for the trigger.
The pointer indicates the trigger position in the internal memory.
Cursors for cursor measurement.
Current triggering value.
Setting time (touchable).
It indicates that there is a USB flash disk connecting with the oscilloscope.
Cursor measure
window, showing the readings of the two cursors and
absolute value.
2
3
4
5
6
7
8
9
10
The waveform of CH1.
Automatic mode and acquire waveform without triggering.
Trigger detected and acquire waveform.
Pre-triggered data captured and ready for a trigger.
Capture and display the waveform continuously.
Data acquisition stopped.
OD-624
QUICK REFERENCE GUIDE
The pointer shows the trigger level position of the source in trigger menu.
The waveform of CH4.
The waveform of CH2.
The waveform of Math.
The waveform of CH3.
The cymometer of the source in trigger menu.
Trigger settings of the source in trigger menu.
The icon shows the trigger type; the reading shows the trigger level value:
The bottom menu bar
The reading shows the setting of
main time base.
The readings show current sample rate and the record length.
11
12
13
14
15
16
17
19
20
21
22
The green pointer indicates the grounding datum point (zero point position)
of the waveform of the CH4 channel.
The red pointer indicates the grounding datum point (zero point position)
of the waveform of the CH1 channel.
The readings indicate the Voltage Division of corresponding channels.
The icon shows the coupling mode and other settings of the channel:
" " DC coupling.
"~" AC coupling.
" " Ground coupling.
24
26
Current trigger type:
Rising edge or slope triggering.
Falling edge or slope triggering.
Pulse triggering.
Video line synchronous triggering.
Video field synchronous triggering.
" W "
" ¯ "
"Bw"
The purple pointer indicates the grounding datum point (zero point position)
of the waveform of the CH3 channel.
25
The yellow pointer indicates the grounding datum point (zero point position)
of the waveform of the Ch3 channel.
27
The blue pointer indicates the zero point position of the waveform of the Math.
18
Impedance 50 W.
Inverted.
Band Width 20 M.
It indicates the measured type and value of the corresponding channel.
F:
T:
V:
Vp:
Vk:
Ma:
Mi:
Vt:
Vb:
Va:
Os:
Ps:
RT:
FT:
PW:
NW:
+D:
- D:
PD:
ND:
23
Frequency.
Cycle.
Average value.
Peak-peak value.
Root-mean-square value.
Maximum amplitude value.
Minimum amplitude value.
Voltage value of the waveform's flat top value.
Voltage value of the waveform's flat base.
Amplitude value.
Overshoot value.
Preshoot value.
Rise time value.
Fall time value.
+D width value.
D Width value.
+Duty value.
-Duty value.
Delay A B value.
Delay A B value.
OD-624
QUICK REFERENCE GUIDE
TOUCHSCREEN CONTROLS
Operate the menu through Touchscreen or Buttons/Knob
Press repeatedly to
switch the options
Touch to set time
Touch to display the
Cursor Measure Menu
Touch to select
the menu item
Touch to select
the menu item
Drag to scroll
the list
Touch to select
the menu item
Touch to
display the
Measure Menu
OD-624
QUICK REFERENCE GUIDE
Set the Vertical System through touchscreen
Control the vertical
position/voltage division of
the selected channel
Selected Unselected
Touch to select the channel
Touch to switch between unselected/selected to
control the vertical gesture on the left screen
Control the trigger level of
the source in trigger menu
Set the Horizontal System through touchscreen
Increase the
time base
Control the horizontal position
Decrease the
time base
OD-624
QUICK REFERENCE GUIDE
Horizontal Operations Zoom Window
Main Window
Zoom Window
Control the horizontal position of Main Window
Control the horizontal position of Zoom Window
Increase the time base
of Zoom Window
Decrease the time base
of Zoom Window
Horizontal Operations Main Window
Control the horizontal position of Zoom Window
Control the horizontal position of Main Window
Increase the time base
of Main/Zoom Window
Decrease the time base
of Main/Zoom Window
Zoom the Waveform through Touchscreen
Touch to switch between unselected/selected to
control the vertical gesture on the left screen
Control the vertical
position/voltage division of
the selected channel
Control the trigger level of
the source in trigger menu
OD-624
PDF
USER MANUAL
DOWNLOAD
Find the user's manual on the download area at :
www.promaxelectronics.com
28-07-2014 (0 DG0153)
v1.0
OD-624
QUICK REFERENCE GUIDE
REAR PANEL
15
16
17
18
20
21
22
19
16
15
17
Air vents
VGA port
USB Device port
19
18
20
USB Host port
Handle
LAN port
22
21
Trigger signal output & Pass/Fail output port
AC power input jack
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Promax OD-624 Reference guide