Dedicated Micros ©2007
12
BX2 Network Guide
DAY/NIGHT/WEEKEND Utilise these options to set individual camera record proles.
To establish a prole for a specic camera; choose Prole from
the drop dowm menu and select the Edit button to establish
parameters.To set the camera with the global record proles,
select Std. To turn camera Off, select Off. Please refer to section
headed; Editing Camera Proles, for further guidance regarding
establishing individual camera proles.
Terminated As the unit supports loop through it is necessary to remove the
termination of any inputs that are ‘looped’, by default all inputs are
terminated at 75 ohms.
Camera Type If required, manually enter the camera type. Select from the
following options; Colour, Mono, IP or Disabled.
Spot Monitor Tick the Spot Monitor checkbox if camera output is to be viewed
on a local spot monitor.
Telemetry The unit supports numerous coaxial telemetry protocols. Please
refer to section headed; How to Select and Enable Coaxial
Telemetry for further information.
Camera Fail Reporting If the video input on the unit does not identify a 1V peak-to-peak
signal then the unit can transmit an alarm notication email for
camera failure on the corresponding video input.
Click here to see thumbnail images
This will display a thumbnail view of video connected to the unit.
Place the cursor in the camera title box to view the corresponding
video input.
Conguring the Network Settings of the unit
The unit can be allocated an IP address and associated settings via the serial port or OSD menus,
this web page allows these settings to be checked and changed if required.
To check / congure the network information:
1. Select Network -> Network Settings.
2. If the IP address, subnet mask and default gateway have already been congured via
the serial port or OSD menus these will be displayed here. These can be changed by
entering the new information in the relevant areas.
3. The unit supports Domain Name Server allowing the unit to reference other hosts by
their name rather than their IP address. Enter the IP address of the primary DNS and
secondary DNS server.
4. The default system name for the unit is BX2, this can be changed to a more appropriate
name by entering the information in this section.
5. As the unit can be connected to a LAN, WAN or ISDN network, it is possible to identify
the maximum bit rate for the network connection. There are default settings for LAN,
WAN and ISDN. If these defaults are acceptable, select the corresponding button for
your network link. If these default settings are not as required, enter the new data in the
relevant options (Max Transfer Rate, Transiit Image Buffers and Ethernet MTU).
6. Enter the TCP Re-transmit Time in milliseconds, this settings should be discussed with
your Network Manager.
7. The secondary webserver port is system specic and allows a port to be allocated for
webserving if the network is already utilising the default port.
8. Remember to save the conguration by selecting Save Settings!