CAL-ROYAL PST-201 Panic Saddle Threshold

Cal-Royal CAL-ROYAL PST-201 Panic Saddle Threshold, PST-201 Panic Saddle Threshold User manual

  • Hello! I've reviewed the installation guideline for the CAL-ROYAL PST-201 Panic Saddle Threshold. This document provides detailed steps on fitting, trimming, and installing the threshold, including the fire door ratings. I'm ready to answer your questions about this product and its installation.
  • What screw size should be used?
    What should I do to ensure proper installation?
    How much longer should the seal be trimmed?
MATERIAL FOR USE IN LISTED STEEL FRAMES AND CLASSIFIED HOLLOW METAL STEEL COMPOSITE TYPE FIRE
DOORS ARE RATED UP TO AND INCLUDING 3 HOURS, WOOD COMPOSITE TYPE FIRE DOORS ARE RATED UP TO AND
INCLUDING 1-1/2 HOURS, AND WOOD CORE FIRE DOORS ARE RATED 20 MINUTES WITHOUT HOSE STREAM.
PST-201 Series
1/2” H x 5” W x 36” L
12.7 mm x 127 mm x 914.4 mm
1/2” (12.7mm) PANIC SADDLE THRESHOLD
INSTALLATION GUIDELINE :
1. Carefully measure to fit within the frame opening and make sure the vinyl makes contact
with door face when door is closed.
2. If necessary trim and notch the threshold ends to accommodate the side jamb stops.
3. Trim seal 1/8” longer than the retainer threshold at each end.
4. Mark and drill pilot holes through the pre-drilled holes in the threshold and fasten with
screws provided.
Use a weatherproof sealant at all edges and joints.
5. Operate the door multiple times to ensure proper adjustment so as not to prevent the door
from self-closing and latching.
INSTALLATION INSTRUCTIONS
5
1 ⁄
⁄
⁄
⁄
SCREW SIZE : #10 x 1-1/2" PFHWS
DWG # TWG5037 - 1/1 - MAR2022
/