Specifications
Additional information can be found online at www.heatilator.com
Product information provided is not
complete and is subject to change
without notice. Product installation
must adhere strictly to instructions
accompanying product to avoid risk
of fire and potential injury.
Phone: (800) 927-6841
Web: www.heatilator.com
PRODUCT LISTING CODES
US ANSI Z21.88-2017
CAN CSA 2.33-2017
UL307B
Rave32-IFT-B
HTL/Rave32-IFT-B_0220
Combustible Mantels
911
13
14
TO CEILING
6
9
12
3
68
10
11
TO CEILING
6
9
12
3
Combustible Mantels -
Passive Heat Kit Installed
12" MAX.
1/2"
THICK WALL
SHEATHING
14" MIN. BOTTOM
OF MANTEL TO TOP OF
APPLIANCE OPENING
NON-COMBUSTIBLE
MANTEL
6"
MAX.
WALL
3' MAX.
6"
MIN.
APPLIANCE OPENING WALL
UNLIMITED
7"
MIN.
APPLIANCE OPENING
MANTEL PROJECTIONS
(or other materials above appliance)
NON-COMBUSTIBLE MANTEL PROJECTIONS
(or other materials above appliance)
AREA TO COMBUSTIBLES
CLEARANCE TO
CEILING 31" [787]
NON-COMBUSTIBLE
FLOOR 0" [0]
COMBUSTIBLE
FLOORING 0" [0]
BEHIND
APPLIANCE 1/2" [13]
SIDES OF
APPLIANCE 1/2" [13]
FRONT OF
APPLIANCE 36" [914]
MANTEL LEG/WALL PROJECTIONS
(acceptable on both sides of appliance)
APPLIANCE LOCATION
44-5/8" (1134)
15-1/16"
(383)
44-5/8"
(1134) 63-1/8" (1603)
TOP VENT
ONE 90
0
ELBOW
TOP VENT
ONE 90° ELBOW
37-5/8" (956)
17-1/4" (438)
Refer to Section 10.C for mantel and wall
projection information in installation manual.
Consider the mantel or cabinet system to be
installed and comply with the necessary
requirements for elevated hearth. Refer to
instructions included with cabinet system.
18" (457 mm) required
when Passive Heat Side
Discharge Kit is installed.
1/2"
SEE INSTALL MANUAL
FOR ALCOVE
INSTALLATION
8-5/8"
[219]
17-3/4"
[451]
37"
[940]
NOTE: Header MUST be
installed on end as
shown in the diagram.
HEADER: Two 2 X 4s or Two 2 X 6s
installed on end
36-1/2"
[927]
31"
0"
0"
1/2"
1/2"
36"
[787]
[13]
[13]
[914]
MEASURE FROM TOP
OF APPLIANCE OPENING
TO CEILING
MINIMUM FRAMING DIMENSIONS
WALL PENETRATION
41-1/2"
40-1/2"
[1054]
[1029]
10"
10"
DO NOT PACK WITH
INSULATION OR
OTHER MATERIAL
Shows center of vent framing hole
for top or rear venting. The center
of the hole is 1" (25mm) above the
center of the horizontal vent pipe.
MINIMUM FIREPLACE CLEARANCES /
CLEARANCES TO COMBUSTIBLES