EQUINOX EQLED088 User manual

Category
Stroboscopes & disco lights
Type
User manual

This manual is also suitable for

Order code: EQLED088
Crossre XP
User Manual
www.prolight.co.uk Crossre XP User Manual 2
Safety advice
WARNING
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL
CAREFULLY BEFORE YOUR INITIAL START-UP!
• Beforeyourinitialstart-up,pleasemakesurethatthereisnodamagecausedduringtransportation.
• Shouldtherebeanydamage,consultyourdealeranddonotusetheequipment.
• Tomaintaintheequipmentingoodworkingconditionandtoensuresafeoperation,itisnecessary
fortheusertofollowthesafetyinstructionsandwarningnoteswritteninthismanual.
• Pleasenotethatdamagescausedbyusermodicationstothisequipmentarenotsubjecttowarranty.
IMPORTANT:
The manufacturer will not accept liability for any resulting damages caused by the non-observance
of this manual or any unauthorised modication to the equipment.
OPERATING DETERMINATIONS
Ifthisequipmentisoperatedinanyotherway,thanthosedescribedinthismanual,theproductmaysufferdamageand
thewarrantybecomesvoid.Incorrectoperationmayleadtodangere.g:short-circuit,burnsandelectricshocksetc.
Donotendangeryourownsafetyandthesafetyofothers!
Incorrectinstallationorusecancauseseriousdamagetopeopleand/orproperty.
CAUTION!
KEEP THIS EQUIPMENT
AWAY FROM RAIN,
MOISTURE AND LIQUIDS
CAUTION!
TAKE CARE USING
THIS EQUIPMENT!
HIGH VOLTAGE-RISK
OF ELECTRIC SHOCK!!
• Neverletthepowercablecomeintocontactwithother
cables.Handlethepowercableandallmainsvoltage
connectionswithparticularcaution!
• Neverremovewarningorinformativelabelsfromtheunit.
• Donotopentheequipmentanddonotmodifytheunit.
• Donotconnectthisequipmenttoadimmerpack.
• Donotswitchtheequipmentonandoffinshortintervals,
asthiswillreducethesystem’slife.
• Onlyusetheequipmentindoors.
• Donotexposetoammablesources,liquidsorgases.
• Alwaysdisconnectthepowerfromthemainswhen
equipmentisnotinuseorbeforecleaning!Onlyhandle
thepower-cablebytheplug.Neverpullouttheplugby
pullingthepower-cable.
• Makesurethattheavailablemainssupplyvoltageis
between100~240VAC,50/60Hz.
• Makesurethatthepowercableisnevercrimpedor
damaged.Checktheequipmentandthepowercable
periodically.
• Iftheequipmentisdroppedordamaged,disconnectthe
mainspowersupplyimmediatelyandhaveaqualied
engineerinspecttheequipmentbeforeoperatingagain.
• Iftheequipmenthasbeenexposedtodrastic
temperatureuctuation(e.g.aftertransportation),
donotconnectpowerorswitchitonimmediately.
Thearisingcondensationmightdamagetheequipment.
Leavetheequipmentswitchedoffuntilithasreached
roomtemperature.
• Ifyourproductfailstofunctioncorrectly,stopuse
immediately.Packtheunitsecurely(preferablyinthe
originalpackingmaterial),andreturnittoyourProLight
dealerforservice.
• Onlyusefusesofsametypeandrating.
• Repairs,servicingandpowerconnectionmustonlybe
carriedoutbyaqualiedtechnician.THISUNITCONTAINS
NOUSERSERVICEABLEPARTS.
• Thislightingxtureisforprofessionaluseonly-itis
notdesignedfororsuitableforhouseholduse.The
productmustbeinstalledbyaqualiedtechnicianin
accordancewithlocalterritoryregulations.Thesafetyof
theinstallationistheresponsibilityoftheinstaller.The
xturepresentsrisksofsevereinjuryordeathduetore
hazards,electricshockandfalls.
• Warning!RiskGroup2LEDproductaccordingto
EN62471.Donotviewthelightoutputwithoptical
instrumentsoranydevicethatmayconcentratethebeam.
• WARRANTY:Oneyearfromdateofpurchase.
www.prolight.co.uk Crossre XP User Manual 3
Product overview & technical specications
Thisroomllingeffectfeatures8gobosthatsweeptheroomwhilstchangingcolour.Theunitworkswellasa
stand-alonecentrepieceorcanbecombinedandlinkedinmaster/slavemode.Loadedwith8x10WRGBWLEDs
itcoverslargeroomswitheasemakingthemidealformobileentertainersandsmallvenues.
•8x10WLEDs(R:2,G:2,B:2,W:2)
•DMXchannels:8
•Auto,soundactiveandmaster/slavemodes
•0-100%dimmingandvariablestrobe
•Suppliedwithhangingbracket
•4pushbuttonmenuwithLEDdisplay
•IECpowerinput/output
•3-PinXLRinput/output
•Fancooled
Crossre XP
Specications Crossre
Powerconsumption 85W
Powersupply 100~240V,50/60Hz
Fuse T1A250V
Dimensions 250x255x240mm
Weight 3.85kg
Ordercodes EQLED088
250mm
255mm 240mm
01-Hangingbracket
02-Hangingbracket
adjustmentknob
03-LEDdisplay
04-Functionbuttons
05-IECpowerinput
06-IECpoweroutput
07-Fuse:T1A250V
08-3-PinXLRDMXinput
09-3-PinXLRDMXoutput
10-Safetyeye
POWER INPUT:
100-240V~50/60Hz
FUSE: T1A 250V
POWER OUTPUT
MENU DOWNUP ENTER
DMX OUTPUT
www.prolight.co.uk
DMX INPUT
CROSSFIRE XP
01
05
07
01
03
0806
10
09
02 02
04
Inthebox:1 x xture,
1 x power cable &
1 x user manual
www.prolight.co.uk Crossre XP User Manual 4
DMX mode:
ToselecttheDMXaddress,pressthe“MENU”buttonontherearoftheunittoshowA001ontheLED
display.Nowusethe“UP”and“DOWN”buttonstoselecttheDMXaddressbetween001-512.
Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.
Auto mode:
Toaccesstheautomode,pressthe“MENU”buttonontherearoftheunittoshowbetweenA1 -and
A8 -.Usethe“UP”and“DOWN”buttonstoadjustthespeedbetweenA1 1~A1 9.Pressthe
“ENTER” buttontoconrmthesetting.Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.
Sound active mode:
Toaccessthesoundactivemode,pressthe“MENU”buttonontherearoftheunittoshoweitherS1
-(Soundmode1)orS2 -(Soundmode2).Pressthe“ENTER” buttontoconrmthesetting.Toexit
outofanyoftheaboveoptions,pressthe“MENU”button.
Master/slave mode:
Tosetthemasterunit,pressthe“MENU”buttonontherearofthemasterunittoselectyourdesired
program(soundactiveorauto).
Tosettheotherunitsinslavemode,pressthe“MENU”buttonontherearoftheunittoshowA001
ontheLEDdisplay.Theunitwillnowruninsequencewiththemasterunit.
Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.
Pleasenote:WhenusingthextureinDMXmodeandalldimmersaresetto100%theunitwillreduce
thebrightnessbyapproximately20%toprotecttheLEDs.
Operating instructions
8 channel mode:
Channel Value Function
1 000-255 Masterdimmer(0-100%)
2000-255 Red(0-100%)
3000-255 Green(0-100%)
4 000-255 Blue(0-100%)
5 000-255 White(0-100%)
6 000-009 Strobeoff
010-255 Strobespeed(fast-slow)
7 000-005 Motorstop
006-127 Motorclockwiserotationspeed(slow-fast)
128-255 Motoranti-clockwiserotationspeed(fast-slow)
8 000-009 Nofunction
010-072 Automode1speed(slow-fast)
073-134 Automode2speed(slow-fast)
135-197 Automode3speed(slow-fast)
198-220 Soundactivemode1
221-255 Soundactivemode2
www.prolight.co.uk Crossre XP User Manual 5
Operating instructions
Automode A1 1~A1 9 Red-Speed
A2 1~A2 9 Green-Speed
A3 1~A3 9 Blue-Speed
A4 1~A4 9 White-Speed
A5 1~A5 9 Automode1-Speed
A6 1~A6 9 Automode2-Speed
A7 1~A7 9 Automode3-Speed
A8 1~A8 9 Automodewithstrobe-Strobespeed
Soundactivemode S1 Soundmode1
S2 Soundmode2
Addresssetting A001~A512
Menusystem
www.prolight.co.uk Crossre XP User Manual 6
Setting the DMX address:
TheDMXmodeenablestheuseofauniversalDMXcontroller.Eachxturerequiresa“startaddress”
from1-512.Axturerequiringoneormorechannelsforcontrolbeginstoreadthedataonthechannel
indicatedbythestartaddress.Forexample,axturethatoccupiesoruses7channelsofDMXandwas
addressedtostartonDMXchannel100,wouldreaddatafromchannels:100,101,102,103,104,105
and106.Chooseastartaddresssothatthechannelsuseddonotoverlap.E.g.thenextunitinthe
chainstartsat107.
DMX 512:
DMX(DigitalMultiplex)isauniversalprotocolusedasaformofcommunicationbetweenintelligent
xturesandcontrollers.ADMXcontrollersendsDMXdatainstructionsformthecontrollertothexture.
DMXdataissentasserialdatathattravelsfromxturetoxtureviatheDATA“IN”andDATA“OUT”
XLRterminalslocatedonallDMXxtures(mostcontrollersonlyhaveadata“out”terminal).
DMX linking:
DMXisalanguageallowingallmakesandmodelsofdifferentmanufacturestobelinkedtogether
andoperatefromasinglecontroller,aslongasallxturesandthecontrollerareDMXcompliant.
ToensureproperDMXdatatransmission,whenusingseveralDMXxturestrytousetheshortest
cablepathpossible.TheorderinwhichxturesareconnectedinaDMXlinedoesnotinuencethe
DMXaddressing.Forexample;axtureassignedtoaDMXaddressof1maybeplacedanywherein
aDMXline,atthebeginning,attheend,oranywhereinthemiddle.Whenaxtureisassigneda
DMXaddressof1,theDMXcontrollerknowstosendDATAassignedtoaddress1tothatunit,
nomatterwhereitislocatedintheDMXchain.
DATA cable (DMX cable) requirements (for DMX operation):
ThisxturecanbecontrolledviaDMX-512protocol.TheDMXaddressissetonthebackoftheunit.
YourunitandyourDMXcontrollerrequireastandard3-pinXLRconnectorfordatainput/output,
seeimagebelow.
Also remember that DMX cable must be daisy chained and cannot be split.
DMX setup
FurtherDMXcablescanbe
purchasedfromallgoodsound
andlightingsuppliersor
ProLightConceptsdealers.
Pleasequote:
CABL10 – 2m
CABL11 – 5m
CABL12 – 10m
www.prolight.co.uk Crossre XP User Manual 7
Notice:
Besuretofollowthediagramsbelowwhenmakingyourowncables.Donotconnectthecables
shieldconductortothegroundlugorallowtheshieldconductortocomeincontactwiththeXLRs
outercasing.Groundingtheshieldcouldcauseashortcircuitanderraticbehaviour.
Special note:
Line termination:
Whenlongerrunsofcableareused,
youmayneedtouseaterminatoron
thelastunittoavoiderraticbehaviour.
Using a cable terminator will decrease
the possibilities of erratic behaviour.
(3-pin - Order ref: CABL90, 5-pin - Order ref: CABL89)
5-pin XLR DMX connectors:
Somemanufacturesuse5-pinXLRconnectorsfordatatransmissioninplaceof3-pin.5-pinXLRxtures
maybeimplementedina3-pinXLRDMXline.Wheninsertingstandard5-pinXLRconnectorsintoa
3-pinlineacableadaptormustbeused.Thediagrambelowdetailsthecorrectcableconversion.
Terminationreducessignaltransmission
problemsandinterference.itisalways
advisabletoconnectaDMXterminal,
(resistance120Ohm1/4W)betweenpin2
(DMX-)andpin3(DMX+)ofthelastxture.
5-pin XLR (female)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
3-pin XLR (female)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
3-pin XLR (male)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
5-pin XLR (male)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
DMX setup
www.prolight.co.uk Crossre XP User Manual 8
Operating instructions & WEEE notice
Correct Disposal of this Product
(Waste Electrical & Electronic Equipment)
(Applicable in the European Union and other European countries
with separate collection systems)
Thismarkingshownontheproductoritsliterature,indicatesthatitshouldnotbedisposedof
withotherhouseholdwastesattheendofitsworkinglife.Topreventpossibleharmtothe
environmentorhumanhealthfromuncontrolledwastedisposal,pleaseseparatethisfromother
typesofwastesandrecycleitresponsiblytopromotethesustainablereuseofmaterialresources.
Householdusersshouldcontacteithertheretailerwheretheypurchasedthisproduct,ortheir
localgovernmentofce,fordetailsofwhereandhowtheycantakethisitemforenvironmentally
saferecycling.
Businessusersshouldcontacttheirsupplierandcheckthetermsandconditionsofthe
purchasecontract.Thisproductshouldnotbemixedwithothercommercialwastesfordisposal.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

EQUINOX EQLED088 User manual

Category
Stroboscopes & disco lights
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI