Bard MGR4451ADB/Q/W/S Installation & Operation Manual

Type
Installation & Operation Manual
Manual 2100-566D
Page 1 of 20
CONTROLLER INSTALLATION
OPERATION & QUICK START
Bard CompleteStat™
CS9B-THO, CS9B-THOC
CS9BE-THO, CS9BE-THOC
Manual: 2100-566D
Supersedes: 2100-566C
File: Tab 19
Date: 11-05-13
Manual 2100-566D
Page 2 of 20
TABLE OF CONTENTS
Installation
Note ............................................................................Page 3
Controller Installation ................................................Page 3
Controller Connections ...............................................Page 3
Basic Operation
Note ............................................................................Page 4
Quick-Start Programming .....................................Page 4 & 5
Auxiliary Heat / Electric Heat Setup ............................Page 5
Compressor Lockout Temperature ........................ Page 5 & 6
System Enable ............................................................Page 6
Temperature Setpoints ................................................Page 6
Terminal Descriptors ...................................................Page 6
Sequence of Operation .........................................Page 7 & 8
Wiring Diagrams
Wiring Diagram Table (Index) .....................................Page 9
Wiring Diagrams ..............................................Pages 10 - 20
2100-566D
Page 3 of 20
*INSTALL NOTE: For optimum temperature sensor performance, the Bard CompleteStat
TM
must be mounted on an
interior wall and away from any heat sources, sunlight, windows, air vents, air circulation obstructions, and/or any other
cause of erratic or false temperature sensing.
Controller Installation: Mounting Controller
1. Complete rough-in wiring using a minimum 18 AWG solid-conductor control wiring, see Low Voltage Wiring
Diagrams in this Manual for exact number of conductors.
2. Turn the hex screws in the bottom and top of the controller clockwise (inward) until they clear the cover.
Remove base plate from controller.
3. Route completed wiring through base plate.
4. With the embossed “UP” arrows of the base plate pointing in the appropriate direction, fasten the base plate to
the desired wall location. A vertical/horizontal 2x4 wall handybox can be used for CO
2
-Sensing CompleteStat™,
and a vertical-only 2x4 wall handybox can be used for Non-CO
2
-Sensing CompleteStat™.
5. Make appropriate control wire connections (see Low-Voltage Wiring Manual) to terminal blocks.
6. Replace controller over base plate, being careful not to pinch/dislodge connections.
7. Turn hex screws in bottom/top of controller counter-clockwise (outward) to secure cover.
Controller Connections: Terminal legend
Terminal Function Type Form
D
Dehumidification
Output
24VAC SPST RELAY
SC
24VAC to Relay Outputs D, A, W2
Power
A
Ventilation Call
Output
24VAC SPST RELAY
W2
2
nd
Stage Heating
Output
24VAC SPST RELAY
W1/E
1
st
Stage Heating/Emer. Heat
Output
24VAC SPST RELAY
SC
24VAC to Relay Outputs W1/E, Y2, Y1
Power
Y2
2
nd
Stage Compressor
Output
24VAC SPST RELAY
Y1
1
st
Stage Compressor
Output
24VAC SPST RELAY
Y0
Economizer
Output
24VAC SPST RELAY
SC
24VAC to Relay Outputs YO, O/B, G
Power
O/B
Reversing Valve
Output
24VAC SPST RELAY
G
Indoor Blower
Output
24VAC SPST RELAY
IN9
Not Used
ROS
Remote Occupancy Sensor
Input
Dry Contact (Input to GND)
GND
REM
Remote Temperature Sensor
Input
10K Type II Thermistor
+B
Communications
-A
Communications
OAT
Outdoor Air Temperature Sensor
Input
10K Type II Thermistor
LAT
Leaving Air Temperature Sensor
Input
10K Type II Thermistor
GND
Control Ground
L
Lockout Alarm
Input
Dry Contact (Input to GND)
Com
24VAC Common
Power
24V
24VAC Hot
Power
2100-566D
Page 4 of 20
Basic Operation: Home, Main Menu, and Override Screens
Navigate the menus & change settings by pressing a combination of various arrow buttons/the Enter button. Push the:
Enter button to select and/or exit value editing
Up or Down button to move among entries
2
Right or Left button to move among value fields
Left button to return to the home screen
NOTE
2
: Although cooling/heating setpoints can be accessed by simply pressing the arrow keys during normal operation,
any changes made in this fashion will be for a specific length-of-time as an “override” feature only. This temperature
change will not be permanent. See the Temperature Setpoints for further information.
Quick Start Programming: System Selection, System Enable, Aux. Heat, and Temperature Setpoints.
System Selection to select A/C or HP, stages of heating and cooling, and with/without economizer, press:
1. Right button to access the Main Menu screen
2. Down button through entries to highlight Advanced
3. Enter button to select Advanced and enter Advanced Screen
4. Enter button again to select/enter Applications Screen
5. Controller will ask for Admin Level Password
Factory Default Admin Level Password: BARD
Press Enter
6. Enter button to choose Degrees Scale (IF NECESSARY)
1
*NOTE
1
: On changing temperature scale, the APP category must be set to
“NOT CONFIGURED” before the controller will allow you to change scale
7. Up/Down buttons to choose °Fahrenheit or °Celsius
8. Enter button to save selection of scale. See Note A.
9. Down button to highlight App
10. Enter button to highlight current selection
11. Up/Down buttons to choose from available System types:
A/C
HP
12. Enter button to select/save appropriate model
13. Down button to highlight Opt
14. Enter button to highlight current selection
15. Up/Down buttons to choose from available System Stages:
AC HP Note A. The change from "F" to "C"
1H/1C 1 Stage will not take effect on the Home Screen
2H/2C 2 Stage until the 24VAC power is cycled off and
1H/2C back on.
2H/1C
16. Enter button to select/save appropriate model stage
17. Down button to highlight Additional Setup
18. Enter button to select/enter Additional Setup Screen
19. Down button to highlight Damper, press Enter button to select
2100-566D
Page 5 of 20
20. Enter button to highlight current economizer selection
21. Up/Down buttons to choose from available Economizer options:
None = No Economizer, or Standard Vent. Pkg. (ERV/CRV/MFAD)
En/Dis (Engage/Disengage) = Economizer in system
22. Enter button to select/save appropriate economizer options
23. Left arrow back to additional setup
24. Down button to locate & highlight Valve (if HP was chosen)
25. Enter button to select/enter Valve (if HP was chosen)
26. Right button to highlight Valve options (if HP was chosen)
27. Up/Down buttons to choose from Valve options: (if HP was chosen)
ACTIVE HTG
ACTIVE CLG
28. Enter button to save Valve option choice (if HP was chosen)
29. Left button (6x) to navigate back to home page
Auxiliary Heat/Electric Heat Setup If a heat pump is chosen, then the
electric heat strips must be configured. These steps do not apply to air
conditioners or other types of conventional heating. To configure the
auxiliary heat from the home screen, press:
1. Right button to access the Main Menu screen
2. Down button through entries to highlight Advanced
3. Enter button to select Advanced and enter Advanced Screen
4. Enter button again to select/enter Applications Screen
5. Controller will ask for Admin Level Password
Factory Default Admin Level Password: BARD
Press Enter
6. Down button through entries to highlight Additional Setup
7. Enter button to select/enter Additional Setup Screen
8. Enter button again to select/enter Aux Heat
9. Enter button again to highlight Aux Heat choices
10. Up/Down buttons to toggle through available choices
W/O Lockout Auxiliary heat will activate regardless of compressor operation or outdoor air temperature (factory default)
- If W/O Lockout is chosen, proceed to set delay-on time
Comp Lockout Compressor locks out below the selected Outdoor Air Temperature. (Requires optional 8301-
061 Outdoor Air Temperature Sensor.)
None no auxiliary strip heat, controller will not energize W2
- If None is chosen, Left button (5x) to return to home screen
11. Down button to highlight Delay (mins)
12. Enter button to highlight default Delay minutes
13. Up/Down buttons to select the amount of minutes you would like to delay the electric heat before activation.
14. Enter button to save choice.
15. Left button (5x) to return to home screen.
Compressor Lockout Temperature If you have chosen auxiliary heat strip configuration “Comp Lockout,” an
optional outdoor air temperature sensor will have to be installed/configured to specifically set the temperature at
which the compressor will no longer be allowed to operate. To install the 8301-061 Outdoor Air Temperature
Sensor, attach the leads to terminals “OAT” and “GND.” To set the compressor outdoor air temperature from
the home screen, press
1. Right button to access the Main Menu screen
2. Down button through entries to highlight Advanced
3. Enter button to select Advanced and enter Advanced Screen
4. Down button through entries to highlight Limits
5. Enter button to select Limits and enter Limits Screen
6. Down through entries to highlight Comp OAT Low
7. Enter button to select current Comp OAT Low setting
8. Up/Down button to desired outdoor air temperature for compressor lockout
2100-566D
Page 6 of 20
9. Enter button to save choice
10. Left button (3x) to home screen.
System Enable to enable heating / cooling from home screen, press:
1. Right button to access the Main Menu Screen
2. Down button through entries to highlight System
3. Enter button to select System and enter System Screen
4. Enter button again to highlight current System Enable choice
5. Up/Down buttons to choose from available System Enable options
Auto: System is in “Auto-Changeover” mode. HVAC system will cycle heating and cooling automatically to
stay within preset heating and cooling setpoints.
Heating: System is in “Heating-Only” mode. HVAC system will cycle heating in reference to Heating
Setpoint only. Unit will not activate cooling sequence.
Cooling: System is in “Cooling-Only” mode. HVAC system will cycle cooling in reference to Cooling Setpoint
only. Unit will not activate heating sequence.
Emer HT: HP mode only.
Off: HVAC system is inactive.
6. Enter button to select/save appropriate mode selection
7. Left button (2x) to navigate back to home page.
Temperature Setpoints to access temperature setpoints from the home screen, press:
1. Right button to access the Main Menu Screen
2. Down button through entries to highlight Setpoints
3. Enter button to select Setpoints and enter Setpoints Screen
4. Enter button to select Cool Setpt
3
5. Up/Down buttons to enter appropriate cooling setpoint
6. Enter button to save new Cool Setpt
4
7. Down button to highlight Heat Setpt
8. Enter button to select Heat Setpt
9. Up/Down buttons to enter appropriate heating setpoint
10. Enter button to save new Heat Setpt
11. *REPEAT STEPS IN LIKE FASHION FOR COOL SETBACK & HEAT SETBACK TEMPERATURES, DEHUM SETPOINT & SPAN,
& FOR C0
2
SETPOINT IN PARTS PER MILLION & C0
2
SPAN OF CONTROL IN PARTS PER MILLION (IF AVAILABLE).*
12. Left button (2x) to navigate back to home page
NOTE
3
: The controller will not allow heating/cooling setpoints to contradict one another, or to be within a degree of
conflicting operation.
NOTE
4
: Any system start-up with indoor ambient temperatures lower than 56° F., or above 86° F. will experience an
internal Low-Temperature or High-Temperature alarm. This will not affect normal operation, and can be cleared easily.
Terminal Descriptors Optional Inputs
NOTE: Use twisted shielded pair for optional outdoor and indoor air sensors. Connect shield (drain) to 24V common.
D
SC
A
W2
W1/E
Y2
Y1
YO
O/B
G
IN9
ROS
GND
REM
OAT
LAT
A+
B-
GND
L
COM
24V
CompleteStat
TM
8301-014 Leaving Air
Temperature Sensor
8301-061 Outdoor Air
Temperature Sensor
8301-062 Indoor Remote
Air Temperature Sensor
Remote Occupancy Sensor
(TBD)
BACnet Commercial
Controls Platform
2100-566D
Page 7 of 20
Sequence of Operation: Conventional 1H/1C, 2H/1C, 1H/2C, or 2H/2C without Economizer
Operation G Y/O Y1 Y2 W1/E W2 O/B D A
Fan Only
X
1
st
Stage Cooling
X
X
2
nd
Stage Cooling (if employed)
X
X
X
1
st
Stage Heating
X
X
2
nd
Stage Heating (if employed)
X
X
X
Dehumidification
X
Ventilation
1
X
1
X
NOTE
1
: CS9B(E)-THOC (CO
2
Sensing Capability) Models will activate both G and A terminals upon a ventilation call,
however the CS9B(E)-THO (NON-CO
2
Sensing) Models will activate the A terminal only if there is an existing call for the
indoor blower, whether through space conditioning, or through constant fan operation.
Sequence of Operation: Conventional 1H/1C, 2H/1C, 1H/2C, or 2H/2C with Economizer
Operation G Y/O Y1 Y2 W1/E W2 O/B D A
Fan Only
X
1
st
Stage Cooling (Economizer)
X
X
2
nd
Stage Cooling
X
X
X
3
rd
Stage Cooling (if employed)
X
X
X
X
1
st
Stage Heating
X
X
2
nd
Stage Heating (if employed)
X
X
X
Dehumidification
X
Ventilation
1
X
1
X
NOTE
1
: CS9B(E)-THOC (CO
2
Sensing Capability) Models will activate both G and A terminals upon a ventilation call,
however the CS9B(E)-THO (NON-CO
2
Sensing) Models will activate the A terminal only if there is an existing call for the
indoor blower, whether through space conditioning, or through constant fan operation.
Sequence of Operation: One-Stage Heat Pump, no Economizer
Operation G Y/O Y1 Y2 W1/E W2 O/B D A
Fan Only
X
1
st
Stage Cooling
X
X
1
st
Stage Heating
X
X
X
2
2
nd
Stage Heating
X
X
X
3
X
2
Emergency Heat
X
X
X
3
Dehumidification
X
Ventilation
1
X
1
X
NOTE
1
: CS9B(E)-THOC (CO
2
Sensing Capability) Models will activate both G and A terminals upon a ventilation call,
however the CS9B(E)-THO (NON-CO
2
Sensing) Models will activate the A terminal only if there is an existing call for the
indoor blower, whether through space conditioning, or through constant fan operation.
NOTE
2
: CompleteStat
TM
controller can be configured to energize reversing valve in cooling (See System Selection).
NOTE
3
: Electric Heat must be configured for a Heat Pump application, see Auxiliary Heat/Electric Heat Setup.
2100-566D
Page 8 of 20
Sequence of Operation: Two-Stage Heat Pump, no Economizer
Operation G Y/O Y1 Y2 W1/E W2 O/B D A
Fan Only
X
1
st
Stage Cooling
X
X
2
nd
Stage Cooling
X
X
X
1
st
Stage Heating
X
X
X
2
2
nd
Stage Heating
X
X
X
X
2
3
rd
Stage Heating
X
X
X
X
3
X
2
Emergency Heat
X
X
X
3
Dehumidification
X
Ventilation
1
X
1
X
NOTE
1
: CS9B(E)-THOC (CO
2
Sensing Capability) Models will activate both G and A terminals upon a ventilation call,
however the CS9B(E)-THO (NON-CO
2
Sensing) Models will activate the A terminal only if there is an existing call for the
indoor blower, whether through space conditioning, or through constant fan operation.
NOTE
2
: CompleteStat
TM
controller can be configured to energize reversing valve in cooling (See System Selection).
NOTE
3
: Electric Heat must be configured for a Heat Pump application, see Auxiliary Heat/Electric Heat Setup.
Sequence of Operation: Single-Stage Heat Pump, with Economizer
Operation G Y/O Y1 Y2 W1/E W2 O/B D A
Fan Only
X
1
st
Stage Cooling
X
X
2
nd
Stage Cooling
X
X
X
1
st
Stage Heating
X
X
X
X
2
2
nd
Stage Heating
X
X
X
X
3
X
2
Emergency Heat
X
X
X
3
Dehumidification
X
Ventilation
1
X
1
X
NOTE
1
: CS9B(E)-THOC (CO
2
Sensing Capability) Models will activate both G and A terminals upon a ventilation call,
however the CS9B(E)-THO (NON-CO
2
Sensing) Models will activate the A terminal only if there is an existing call for the
indoor blower, whether through space conditioning, or through constant fan operation.
NOTE
2
: CompleteStat
TM
controller can be configured to energize reversing valve in cooling (See System Selection).
NOTE
3
: Electric Heat must be configured for a Heat Pump application, see Auxiliary Heat/Electric Heat Setup.
Sequence of Operation: Two-Stage Heat Pump, with Economizer
Operation G Y/O Y1 Y2 W1/E W2 O/B D A
Fan Only
X
1
st
Stage Cooling
X
X
2
nd
Stage Cooling
X
X
X
3
rd
Stage Cooling
X
X
X
X
1
st
Stage Heating
X
X
X
X
2
2
nd
Stage Heating
X
X
X
X
X
2
3
rd
Stage Heating
X
X
X
X
X
3
X
2
Emergency Heat
X
X
X
3
Dehumidification
X
Ventilation
1
X
1
X
NOTE
1
: CS9B(E)-THOC (CO
2
Sensing Capability) Models will activate both G and A terminals upon a ventilation call,
however the CS9B(E)-THO (NON-CO
2
Sensing) Models will activate the A terminal only if there is an existing call for the
indoor blower, whether through space conditioning, or through constant fan operation.
NOTE
2
: CompleteStat
TM
controller can be configured to energize reversing valve in cooling (See System Selection)
NOTE
3
: Electric Heat must be configured for a Heat Pump application, see Auxiliary Heat/Electric Heat Setup.
2100-566D
Page 9 of 20
Wiring Diagram Table
Wiring
Diagram
No.
Unit Type
(Note A)
CompleteStat™
Model CS9B(E)-
CompleteStat™
System Type
System
Stages
Setting
Economizer
Setting
Use with Bard
Units
Ventilation System
Vent
Control
Type
1
A/C
THO, THOC
A/C
2H/2C
None
1 or 2-Stage A/C w/
or w/o Elec. Heat
CRV, ERV, MFAD
On/Off
2
A/C
THO, THOC
A/C
2H/2C
EN/DIS
1-Stage A/C with or
w/o Elec. Heat
EIFM Factory "E" Economizer w/W7459 Control
On/Off
3
A/C
THO, THOC
A/C
2H/2C
EN/DIS
1-Stage A/C with or
w/o Elec. Heat
ECONWM Factory "T" or "W" Economizer w/JADE
W7220 Control
On/Off
4
A/C
THO, THOC
A/C
2H/2C
EN/DIS
2-Stage A/C with or
w/o Elec. Heat
EIFM Factory "E" Economizer w/W7459 Control
On/Off
5
A/C
THO, THOC
A/C
2H/2C
EN/DIS
2-Stage A/C with or
w/o Elec. Heat
ECONWM Factory "T" or "W" Economizer w/JADE
W7220 Control
On/Off
6
HP
THO, THOC
HP
1 Stage
None
1-Stage HP with or
w/o Elec. Heat
CRV, ERV, MFAD
On/Off
7
HP
THO, THOC
HP
2 Stage
None
2-Stage HP with or
w/o Elec. Heat
CRV, ERV, MFAD
On/Off
8
HP
THO, THOC
HP
1 Stage
EN/DIS
1 & 2-Stage HP
with or w/o Elec.
Heat
EIFM Factory "E" Economizer w/W7459 Control
On/Off
9
HP
THO, THOC
HP
1 Stage
EN/DIS
1-Stage HP with or
w/o Elec. Heat
ECONWM Factory "T" or "W" Economizer w/JADE
W7220 Control
On/Off
10
HP
THO, THOC
HP
2 Stage
EN/DIS
2-Stage HP with or
w/o Elec. Heat
EIFM Factory "E" Economizer w/W7459 Control
On/Off
11
HP
THO, THOC
HP
2 Stage
EN/DIS
2-Stage HP with or
w/o Elec. Heat
ECONWM Factory "T" or "W" Economizer w/JADE
W7220 Control
On/Off
12
Gas/Electric
THO, THOC
A/C
1H/1C
None
1-Stage A/C with
Gas Heat
CRV, ERV, MFAD
On/Off
13
Gas/Electric
THO, THOC
A/C
1H/2C
None
2-Stage A/C with
Gas Heat
CRV, ERV, MFAD
On/Off
14
Gas/Electric
THO, THOC
A/C
1H/1C
EN/DIS
1-Stage A/C with
Gas Heat
EIFM Factory "E" Economizer w/W7459 Control
On/Off
15
Gas/Electric
THO, THOC
A/C
1H/2C
EN/DIS
2-Stage A/C with
Gas Heat
EIFM Factory "E" Economizer w/W7459 Control
On/Off
16
I-TEC HP
THO, THOC
HP
2 Stage
None
2-Stage HP with or
w/o Elec. Heat
None
On/Off
17
I-TEC HP
THO, THOC
HP
2 Stage
None
2-Stage HP with or
w/o Elec. Heat
CRV, ERV
On/Off
18
I-TEC HP
THO
HP
2 Stage
None
2-Stage HP with or
w/o Elec. Heat
Modulating ERV, use –THO plus 8403-067 CO2
controller
Modulating
19
Q-TEC QA
THO, THOC
A/C
2H/1C
None
1-Stage A/C with or
w/o Elec. Heat
CRV, ERV
On/Off
20
Q-TEC QH
THO, THOC
HP
1 Stage
None
1-Stage HP with or
w/o Elec. Heat
CRV, ERV
On/Off
21
QWS
THO, THOC
HP
2 Stage
None
2-Stage Geo/Water
Source HP
CRV, ERV
On/Off
Note A; Either THO or THOC version can be used. For THO the vent output "A" limits vent operation to Occupied periods. For THOC the vent output "A" operates vent based on CO2 level.
2100-566D
Page 10 of 20
Wiring Diagram 1: Conventional 1H/1C, 1H/2C, 2H/1C, or 2H/2C, with or without dehumidification and ventilation.
Wiring Diagram 2: Conventional 1H/1C, 2H/1C with Honeywell W7459A Control Economizer, with or w/o dehum.
Remove jumper for 2-Stg. heat (15kW or more)
Field-installed wires and jumpers
Factory-installed wires and jumpers
3
Opt. Wire only for 2-Stg. Heating (15kW or more)
4
Wire only for 2-Stg. Cooling, if available
5
Wire not used on MFAD Ventilation option
2
Wire for Dehumidification Units Only
1
6
CompleteStat programmed for
Damper/Economizer: EN/DIS
D
3
A
W2
W1/E
Y2
Y*
G
3
4
2
1
CRV, ERV OR
MFAD
5
HVAC System
3
A
W2
W1/E
Y2
Y1
G
R
3
6
2
1
HONEYWELL
W7459A
HVAC System
Y
E
*NOTE: 2-Stage Units use
“Y1” Terminal Designation
D
SC
A
W2
W1/E
Y2
Y1
YO
O/B
G
IN9
ROS
GND
REM
OAT
LAS
A+
B-
GND
L
COM
24V
CompleteStat
TM
D
SC
A
W2
W1/E
Y2
Y1
YO
O/B
G
IN9
ROS
GND
REM
OAT
LAS
A+
B-
GND
L
COM
24V
CompleteStat
TM
RT
8
RT
8
7
W**A2 Units use “D” Terminal,
W**A1 Units use “3” Terminal
8
For Fire-Smoke/Emergency Shutdown, remove
factory jumper and connect NC contacts from field-
installed device to terminals “RT” and “R,” only
offered on single-stage W**A2 units.
7
7
2100-566D
Page 11 of 20
Wiring Diagram 3: Conventional 1H/1C, 2H/1C with Honeywell W7220 Jade
TM
Control Economizer, with or w/o dehum.
Wiring Diagram 4: Conventional 1H/2C, 2H/2C with Honeywell W7459A Control Economizer
Remove jumper for 2-Stg. heat (15kW or more)
Field-installed wires and jumpers
Factory-installed wires and jumpers
3
Opt. Wire only for 2-Stg. Heating (15kW or more)
2
Wire for Dehumidification Units Only
4
CompleteStat programmed for Damper/Economizer: EN/DIS
1
D
A
W2
W1/E
Y2
Y1
G
R
3
4
2
1
HONEYWELL
W7220
HVAC System
Y
D
A
W2
W1/E
Y2
Y1
G
C
R
3
4
2
HONEYWELL
W7459
HVAC System
Y
D
SC
A
W2
W1/E
Y2
Y1
YO
O/B
G
IN9
ROS
GND
REM
OAT
LAS
A+
B-
GND
L
COM
24V
CompleteStat
TM
D
SC
A
W2
W1/E
Y2
Y1
YO
O/B
G
IN9
ROS
GND
REM
OAT
LAS
A+
B-
GND
L
COM
24V
CompleteStat
TM
RT
6
5
W**A2 units use “D” Terminal, W**A1 units use “3” Terminal
5
6
For Fire-Smoke/Emergency Shutdown, remove factory jumper and connect NC contacts
from field-installed device to terminals “RT” and “R,” only offered on single-stage W**A2
units.
2100-566D
Page 12 of 20
Wiring Diagram 5: Conventional 1H/2C, 2H/2C with Honeywell W7220 Jade
TM
Control Economizer
Wiring Diagram 6: Heat Pump 2H/1C, 3H/1C, with or without dehumidification and ventilation.
Remove jumper for 2-Stg. Aux. heat (15kW or more)
Factory-installed wires and jumpers
Field-installed wires and jumpers
3
4
Field-Installed Wire Nut
5
Wire not used on MFAD Ventilation option
2
Wire for Dehumidification Units Only
1
6
CompleteStat programmed for Damper/Economizer: En/Dis
Opt. Wire only for 2-Stg. Heating (15kW or more)
3
A
W2
W1/E
Y2
Y1
G
3
4
2
HVAC System
Y
PINK
PURPLE
HONEYWELL
W7220
4
5
W3
W2
E
Y2
Y1
G
1
HVAC System
Y
CRV, ERV OR
MFAD
6
W1
B
L
BLK
RED
WHT
BLU
YEL
ORG
(USE ENCLOSED RELAY)
D
SC
A
W2
W1/E
Y2
Y1
YO
O/B
G
IN9
ROS
GND
REM
OAT
LAS
A+
B-
GND
L
COM
24V
CompleteStat
TM
D
SC
A
W2
W1/E
Y2
Y1
YO
O/B
G
IN9
ROS
GND
REM
OAT
LAS
SC
A+
B-
GND
L
COM
24V
CompleteStat
TM
2100-566D
Page 13 of 20
Wiring Diagram 7: Heat Pump 2-Stage, with or without dehumidification and ventilation.
Wiring Diagram 8: Heat Pump 1-Stage, with Honeywell W7459A Control Economizer, with or w/o dehum.
CH*S-Series Heat Pumps use “DH” Dehumidification Terminal
Field-installed wires and jumpers
2
Wire for Dehumidification Units Only
3
CompleteStat programmed for Damper/Economizer: EN/DIS
1
E
F
Wire not used on MFAD Ventilation option
4
5
Factory-installed wires and jumpers
Field-Installed Wire Nut
W3
W2
E
Y1
G
1
HVAC System
Y
CRV, ERV OR
MFAD
3
W1
B
L
2
4
1
HVAC System
PINK
PURPLE
HONEYWELL
W7459
4
5
W3
W2
E
Y1
G
Y
E
W1
B
L
2
BLK
RED
WHT
BLU
YEL
ORG
(USE ENCLOSED RELAY)
BLK
RED
WHT
BLU
YEL
ORG
(USE ENCLOSED RELAY)
D
SC
A
W2
W1/E
Y2
Y1
YO
O/B
G
IN9
ROS
GND
REM
OAT
LAT
A+
B-
GND
L
COM
24V
CompleteStat
TM
D
SC
A
W2
W1/E
Y2
Y1
YO
O/B
G
IN9
ROS
GND
REM
OAT
LAT
A+
B-
GND
L
COM
24V
CompleteStat
TM
2100-566D
Page 14 of 20
Wiring Diagram 9: Heat Pump 1-Stage, with Honeywell W7220 Jade
TM
Control Economizer, with or w/o dehum.
Wiring Diagram 10: Heat Pump 2-Stage, with Honeywell W7459A Control Economizer, with or w/o dehum.
CompleteStat programmed for Damper/Economizer: EN/DIS
Field-installed wires and jumpers
3
Field-Installed Wire Nut
2
Wire for Dehumidification Units Only
4
1
CH*S-Series Heat Pumps use “DH” Dehumidification Terminal
Factory-installed wires and jumpers
2
1
HVAC System
PINK
PURPLE
2
3
W3
W2
E
Y1
G
Y
E
W1
B
L
4
HONEYWELL
W7459
E
F
BLK
RED
WHT
BLU
YEL
ORG
(USE ENCLOSED RELAY)
CompleteStat
TM
D
SC
A
W2
W1/E
Y2
Y1
YO
O/B
G
IN9
ROS
GND
REM
OAT
LAT
A+
B-
GND
L
COM
24V
CompleteStat
TM
2100-566D
Page 15 of 20
Wiring Diagram 11: Heat Pump 2-Stage, with Honeywell W7220 Jade
TM
Control Economizer, with or w/o dehum.
Wiring Diagram 12: Gas/Electric 1H/1C with or without dehumidification and ventilation package
CH*S-Series Heat Pumps use “DH” Dehumidification Terminal
3
Field-Installed Wire Nuts
2
Wire for Dehumidification Units Only
4
CompleteStat programmed for Damper/Economizer: EN/DIS
1
Wire not used on MFAD Ventilation option
5
6
W**G-Series uses “A” Terminal for Ventilation
Field-installed wires and jumpers
Factory-installed wires and jumpers
2
1
HVAC System
PINK
PURPLE
2
4
W3
W2
E
Y1
G
Y
E
W1
B
L
HONEYWELL
W7220
3
3
F
W2
W1
Y
G
1
CRV, ERV OR
MFAD
6
HVAC System
5
BLK
RED
WHT
BLU
YEL
ORG
(USE ENCLOSED RELAY)
D
SC
A
W2
W1/E
SC
Y2
Y1
YO
O/B
G
IN9
ROS
GND
REM
OAT
LAT
SC
A+
B-
GND
L
COM
24V
D
SC
A
W2
W1/E
Y2
Y1
YO
O/B
G
IN9
ROS
GND
REM
OAT
LAT
A+
B-
GND
L
COM
24V
CompleteStat
TM
CompleteStat
TM
2100-566D
Page 16 of 20
Wiring Diagram 13: Gas/Electric 1H/2C with or without dehumidification and ventilation package
Wiring Diagram 14: Gas/Electric 1H/1C with Honeywell W7459A Control Economizer, with or w/o dehum.
Wire not used on MFAD Ventilation option
3
W**G-Series uses “A” Terminal for Ventilation
2
Wire for Dehumidification Units Only
4
CompleteStat programmed for Damper/Economizer: EN/DIS
1
Field-installed wires and jumpers
Factory-installed wires and jumpers
3
F
W2
W1
Y2
Y1
G
1
CRV, ERV OR
MFAD
3
HVAC System
2
3
F
W2
W1
Y
G
R
1
HONEYWELL
W7459A
HVAC System
Y1
Y2
E
F
4
D
SC
A
W2
W1/E
Y2
Y1
YO
O/B
G
IN9
ROS
GND
REM
OAT
LAT
A+
B-
GND
L
COM
24V
CompleteStat
TM
D
SC
A
W2
W1/E
Y2
Y1
YO
O/B
G
IN9
ROS
GND
REM
OAT
LAT
A+
B-
GND
L
COM
24V
CompleteStat
TM
2100-566D
Page 17 of 20
Wiring Diagram 15: Gas/Electric 1H/2C with Honeywell W7459A Control Economizer, with or w/o dehum.
Wiring Diagram 16: I-TEC 2-Stage Heat Pump Series with no ventilation package
CompleteStat programmed for Damper/Economizer: EN/DIS
2
Wire for Dehumidification Units Only
1
Field-installed wires and jumpers
Factory-installed wires and jumpers
Wire not needed if Aux. Heat Strip is 10kW or less
3
3
F
W2
W1
Y
G
C
1
HONEYWELL
W7459A
HVAC System
Y1
Y2
E
F
D
3
4
A
Y1
YO
G
R
1
HVAC System
6
W2
W3
Y2
B/W1
L
BLK
RED
WHT
BLU
YEL
ORG
(USE ENCLOSED RELAY)
3
2
D
SC
A
W2
W1/E
Y2
Y1
YO
O/B
G
IN9
ROS
GND
REM
OAT
LAT
A+
B-
GND
L
COM
24V
CompleteStat
TM
D
SC
A
W2
W1/E
Y2
Y1
YO
O/B
G
IN9
ROS
GND
REM
OAT
LAT
A+
B-
GND
L
COM
24V
CompleteStat
TM
2100-566D
Page 18 of 20
Wiring Diagram 17: I-TEC 2-Stage Heat Pump Series with CRV ventilation package
Wiring Diagram 18: I-TEC 2-Stage HP Series with ERV ventilation package & 8403-067 CO
2
Detector (fully modulating)
Wire not needed if Aux. Heat Strip is 10kW or less
2
Wire for Dehumidification Units Only
1
Field-installed wires and jumpers
Factory-installed wires and jumpers
8403-067 to be used with Non-C02 Sensing CompleteStat
TM
3
D
3
4
A
Y1
YO
G
C
1
HVAC System
6
W2
W3
Y2
B/W1
L
BLK
RED
WHT
BLU
YEL
ORG
(USE ENCLOSED RELAY)
CRV
2
D
3
4
A
Y1
YO
G
1
HVAC System
6
W2
W3
Y2
B/W1
L
BLK
RED
WHT
BLU
YEL
ORG
(USE ENCLOSED RELAY)
ERV
2
1
2
3
4
3
8403-067
5
6
D
SC
A
W2
W1/E
Y2
Y1
YO
O/B
G
IN9
ROS
GND
REM
OAT
LAT
A+
B-
GND
L
COM
24V
CompleteStat
TM
D
SC
A
W2
W1/E
Y2
Y1
YO
O/B
G
IN9
ROS
GND
REM
OAT
LAT
A+
B-
GND
L
COM
24V
CompleteStat
TM
2100-566D
Page 19 of 20
Wiring Diagram 19: Q-TEC QA**/Q**A-Series 1-Stage Air Conditioners, with or without ventilation and dehumidification
Wiring Diagram 20: Q-TEC QH**/Q**H Series 1-Stage Heat Pump, with or without ventilation and dehumidification
Q-Series with factory installed thermostat had no terminal board and were wired directly
from Plug#4. Use provided colors to wire CompleteStat
TM
2
Wire for Dehumidification Units Only
1
Field-installed wires and jumpers
Factory-installed wires and jumpers
1
F
W2
W1
Y1
G
C
R
4
5
9
3
7
6
11
10
HVAC
System
Plug #4
YEL
BRN
WHT
BRN
BLU
YEL
ORG
BLK
WHT
RED
WHT
2
1
4
01
W2
E
Y1
G
C
R
4
5
9
3
7
6
11
10
HVAC
System
Plug #4
YEL
BRN
RED
YEL
ORG
2
1
Y
W1
O/B
TAN
8
BLU
BLK
RED
D
SC
A
W2
W1/E
Y2
Y1
YO
O/B
G
IN9
ROS
GND
REM
OAT
LAT
A+
B-
GND
L
COM
24V
CompleteStat
TM
D
SC
A
W2
W1/E
Y2
Y1
YO
O/B
G
IN9
ROS
GND
REM
OAT
LAT
A+
B-
GND
L
COM
24V
CompleteStat
TM
2100-566D
Page 20 of 20
Wiring Diagram 21: QW*S-Series 2-Stage Heat Pump, with or without ventilation and dehumidification
Bard CompleteStat
TM
should be fully operational at this point. For further controller enhancement or operation detail,
please consult the Advanced Programming section.
Q-Series with factory installed thermostat had no terminal board and were wired directly
from Plug#4. Use provided colors to wire CompleteStat
TM
2
Wire for Dehumidification Units Only
1
Field-installed wires and jumpers
Factory-installed wires and jumpers
1
A
W2
E
Y1
G
C
R
1
5
9
3
7
6
11
10
HVAC
System
Plug #4
BRN
YEL
ORG
2
1
Y
W1
O
8
BLU
Y2
4
PUR
PUR
WHT
BRN
WHT
RED
YEL
BLK
RED
WHT
BLU
YEL
ORG
(USE ENCLOSED RELAY)
L
12
PNK
BLK
WHT
RED
WHT
D
SC
A
W2
W1/E
Y2
Y1
YO
O/B
G
IN9
ROS
GND
REM
OAT
LAT
A+
B-
GND
L
COM
24V
CompleteStat
TM
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

Bard MGR4451ADB/Q/W/S Installation & Operation Manual

Type
Installation & Operation Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI