Regency Fireplace Products Plateau PTO50 Owner's manual

Category
Fireplaces
Type
Owner's manual
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
920-282
04.13.21
Owners &
Installation Manual
Tested by:
Regency Plateau
®
PTO50 Outdoor
Decorative Gas Appliance
Models: PTO50-NG11 / PTO50-LP11
www.regency-fire.com
WARNING:
If the information in these instructions
are not followed exactly, a fire or
explosion may result causing property
damage, personal injury or loss of life.
DANGER - FIRE OR EXPLOSION HAZARD
If you smell gas:
• Shut off gas to the appliance.
• Extinguish any open flame.
• If odour continues, leave the area immediately.
• After leaving the area, call your gas supplier or fire
department.
Failure to follow these instructions could result in fire or
explosion, which could cause property damage, personal
injury, or death.
WARNING: For Outdoor Use Only.
Installation and service must be
performed by a qualified installer,
service agency, or the gas supplier.
WARNING:
Do not store or use gasoline, or other flammable vapors and liquids, in the vicinity of this or any
other appliance.
An LP-cylinder not connected for use shall not be stored in the vicinity of this or any other appli-
ance.
Installer: Leave this manual with the appliance.
Consumer: Retain this manual for future reference.
2 | Regency Plateau
®
PTO50 Outdoor Gas Fireplace
|
2
To the New Owner:
Congratulations!
You are the owner of a state-of-the-art Outdoor Decorative Gas Appliance by Regency
®
. The Regency Plateau
®
PTO50 Outdoor
decorative gas appliance has been designed to provide you with all the warmth and charm of a fire at the flick of a switch.
The Regency Plateau
®
PTO50 Outdoor Decorative Gas Appliance has been approved by Warnock Hersey/Intertek for both
safety and efficiency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many
trouble free years to follow. Please take a moment now to acquaint yourself with these instructions and the many features of
your Regency
®
decorative gas appliance.
MONOXYDE DE CARBONE
Cet appareil peut produire du monoxyde de carbone, un gaz
inodore.
L’utilisation de cet appareil dans des espaces clos peut entraîner
la mort.
Ne jamais utiliser cet appareil dans un espace clos comme un
véhicule de camping, une tente, une automobile ou une maison.
X
X
X
Part # 919-780a
Class IIIA marking
Size@ 100% - 6”H x 2.7”W
Black font on silver background
Apr. 27/17: Created draft
May 8/20: Rev A. Wording changed
919-780a
DANGER
CARBON MONOXIDE HAZARD
This appliance can produce carbon monoxide which has no
odor.
Using it in an enclosed space can kill you.
Never use this appliance in an enclosed space such as a
camper, tent, car or home
.
WARNING:
Improper installation, adjustment, alteration, service
or maintenance can cause injury or property dam-
age. Read the installation, operating and mainte-
nance instructions thoroughly before installing or
servicing this equipment.
Regency Plateau
®
PTO50 Outdoor Gas Fireplace | 3
3
|
table of contents
Copy of Safety Decal .....................................................4
PTO50 Decal Location ..................................................4
dimensions
PTO50 Unit Dimensions ................................................5
PTO80 (PTO50 joined with PTO30 joined end to end) . . 6
PTO100 (2 x PTO50 joined end to end) ........................7
installation
Important Message ......................................................8
Before You Start .............................................................8
General Safety Information ............................................8
Installation Checklist ......................................................9
Locating Your Outdoor Decorative Gas Appliance .........9
Important Information for Outdoor Fireplace
Installations ..................................................................10
Minimum Clearances to Combustibles ........................11
Inner Framing Dimensions (required) ..........................12
Enclosure Vent Installation ..........................................14
Finishing ......................................................................15
Optional Finishing Trim ................................................15
System Data ...............................................................16
High Elevation ..............................................................16
Gas Line Installation ....................................................16
Pilot Adjustment ...........................................................16
Gas Pipe Pressure Testing ..........................................16
886 S.I.T. Valve Description .........................................16
Aeration Adjustment ....................................................16
Joining Two Units End to End ......................................17
Conversion from NG to LP...........................................18
Wall Switch and Battery Installation ............................20
Wall Switch and Battery Installation for Two Units .......21
Optional Hardwire Kit Installation ................................22
AC Adaptor Installation ................................................25
PTO50 Drain Installation (Recommended) ..................26
PTO50 Wiring Diagram ................................................27
PTO100 Wiring Diagram ..............................................27
Glass Crystal/Basalt Volcanic Stones Installation .......28
Optional Log Set Installation ........................................29
Optional Glass Surround/Windshield
Installation PTO50 .......................................................33
Optional Glass Surround/Windshield
Installation PTO100 .....................................................34
Assembly Instructions for a Steel Stud - Table Framing
Kit for PTO50 ...............................................................36
Assembly Instructions for a Steel Stud - Table Framing
Kit for PTO100 .............................................................38
operating instructions
Operating Instructions .................................................41
Lighting Procedure ......................................................41
Shutdown Procedure .....................................................4
First Fire ......................................................................41
Copy of Lighting Plate Instructions ..............................42
Maintenance Instructions ............................................43
Valve Assembly Replacement .....................................44
Gas Maintenance ........................................................45
parts
Parts ............................................................................46
warranty
Warranty ......................................................................50
NOTE: PTO100 = Two PTO50s joined end to end.
PTO80 = PTO50 joined with PTO30 end to end.
4 | Regency Plateau
®
PTO50 Outdoor Gas Fireplace
|
4
safety decal
This is a copy of the label that accompanies each
PTO50 Outdoor decorative gas appliance. We have
printed a copy of the contents here for your review.
NOTE: Regency
®
units are constantly being
improved. Check the label on the unit and if there is
a difference, the label on the unit is the correct one.
COPY OF SAFETY DECAL
For the State of Massachusetts, installation and
repair must be done by a plumber or gas fitter
licensed in the Commonwealth of Massachusetts.
For the State of Massachusetts, flexible connec-
tors shall not exceed 36 inches in length.
For the State of Massachusetts, the appliances
individual manual shut-off must be a t-handle
type valve.
The installation must conform with local codes or, in the absence of local codes, with CAN/CSA-B149.1, Natural Gas and Propane Installation Code or ANSI Z223.1/NFPA 54. The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of
local codes, with the Canadian Electrical Code, CSA C22.1 or with the National Electrical Code, ANSI/NFPA 70. This appliance is only for use with the type of gas indicated on the rating plate . See owner's manual for details.
L'installation doit être conforme aux codes locaux ou, en l'absence de codes locaux, à la normeCAN/CSA-B149.1, gaz naturel et du propane ou du Code d'installation au ANSI Z223.1/NFPA 54.
L'appareil, une fois installé, doit être connecté électriquement à la terre conformément aux codes locaux ou, en l'absence de codes locaux, au Code canadien de l'électricité, CSA C22.1 ou au National Electrical Code, ANSI / NFPA 70.
Cet appareil est à utiliser uniquement avec le type de gaz indiqué sur la plaque signalétique. Voir le manuel d’utilisation pour plus de détails. Electrical supply: 6VDC or 115V 60Hz, less than 1A/Alimentation électrique : 6VDC ou 115V 60Hz, inférieur à 1A.
Part #: 920-254
Colour: Black on grey except what is indicated as being printed red.
Size: (File at 100%)12.525”x 2.7”
Material: 2 ml silver matt polyester (DPM SMS)
Note to Printer: Continue with first serial # number being 556000001.
Mar 27/20: Created draft for approval
May 27/20: Updated with Intertek blurb
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
556
556
FPI Fireplace Products International Ltd.
6988 Venture St.
Delta, BC, Canada V4G 1H4
Minimum Clearances to Combustibles /
Dégagements minimaux aux matériaux combustibles
Serial No./ No de série
Listed: OUTDOOR DECORATIVE GAS APPLIANCE / APPAREIL D’EXTÉRIEUR DÉCORATIF AU GAZ
Certified for/Certifié :
ANSI Z21.97-2017 - CSA 2.41-2017/CSA 2.17-2017
Refer to lntertek's Directory of Building Products for detailed information.
Pour plus de details, se reporter au Repertoire des produits de construction de lntertek.
NOT FOR USE WITH SOLID FUELS. /
NE PAS UTILISER AVEC DES COMBUSTIBLES SOLIDES.
Made in Canada/ Fabriqué au Canada
Duplicate S/N
APPAREIL FONCTIONNANT AU GAZ PROPANE
Modèle PTO50-LP11
PROPANE GAS: Model -LP11PTO50
NATURAL
GAS: Model PT
O50-NG11
Maximum supply pressure
Minimum supply pressure
Manifold pressure high
Manifold pressure low
Orifice size
Maximum input
Minumum input
Altitude
Pression d'alimentation maximale
Pression d'alimentation minimale
Pression manifold lev eé é
Pression manifold basse
Taille de l’orifice
D bit calorifique maximalé
D bit calorifique minimalé
Altitude
14” WC/C.E. (3.49 kPa)
5" WC/C.E. (1.25 kPa)
3.5" WC/C.E. (0.87 kPa)
1.6" WC/C.E. (0.40 kPa)
# 11 DMS
64,000 Btu/h (18.76 kW)
42,000 Btu/h (12.31 kW)
0-4500 ft/pi (0-1372 m)
Pression d'alimentation maximale
Pression d'alimentation minimale
Pression manifold lev eé é
Pression manifold basse
Taille de l’orifice
D bit calorifique maximal é
D bit calorifique minimal seloné
Altitude
14" WC/C.E. (3.49 kPa)
11” WC/C.E. (2.74 kPa)
10 WC/C.E. (2.49 kPa)
6.4" WC/C.E. (1.59 kPa)
# 42 DMS
62,000 Btu/h (18.17 kW)
49,000 Btu/h (14.36 kW)
0-4500 ft/pi (0-1372 m)
Maximum supply pressure
Minimum supply pressure
Manifold pressure high
Manifold pressure low
Orifice size
Maximum input
Minumum input
Altitude
Back Wall
A 18” (457mm)
Side Wall
B 17” (432mm)
Ceiling
C 45” (1143mm)
Unit Base
D 1” (25mm)
APPAREIL FONCTIONNANT AU GAZ NATUREL
Modèle 11PTO50-NG
FOR OUTDOOR USE ONLY / POUR USAGE EXTÉRIEUR SEULEMENT
IF STORED INDOORS, DETACH AND LEAVE CYLINDER OUTDOORS / SI VOUS LE GARDER À L'INTÉRIEUR, DÉTACHER LE CYLINDRE ET LAISSER À L'EXTÉRIEUR
920-254
Minimum ambient air temperature in which appliance may be operated: 32ºF (OºC).
Ne pas faire fonctionner l'appareil si la température ambiante est inférieure à: 32ºF (OºC).
PTO50-LP11
PTO50-NG11
C#4001172
C
A
B
D
C
A
B
D
For Use Only with Barrier (Part # 647-932)
o
Utiliser uniquement avec l’écran (n 647-932)
PTO50 DECAL LOCATION
1) Remove pilot cover on non pilot assembly side.
2) Serial # decal will be affixed to a black metal chain as per below.
Regency Plateau
®
PTO50 Outdoor Gas Fireplace | 5
5
|
dimensions
PTO50 UNIT DIMENSIONS
56 7/16"
1433mm
53 3/16"
1352mm
10 3/8"
263mm
8 1/4"
210mm
ADJUSTABLE
1/2" [13mm] TO 2-3/8" [60mm]
9 1/8"
231mm
57 1/2"
1461mm
1 3/16"
OUTSIDE
OF UNIT TO
MOUNTING
HOLES
30mm
14"
356mm
10 1/2"
267mm
MOUNTING
HOLES
ALL PICTURES / DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ONLY.
ACTUAL PRODUCT MAY VARY DUE TO PRODUCT ENHANCEMENTS.
Gas Connection/Electrical connections
if using optional Hardwire Kit.
6 | Regency Plateau
®
PTO50 Outdoor Gas Fireplace
|
6
dimensions
PTO80 (PTO50 JOINED WITH PTO30 JOINED END TO END)
10 3/8"
263mm
86 7/16"
2196mm
10 1/2"
267mm
MOUNTING HOLES
1 3/16"
30mm
OUTSIDE
OF UNIT TO
MOUNTING
HOLES
14"
356mm
ADJUSTABLE
1/2" [13MM] TO 2 3/8" [60MM]
8 1/4"
210mm
END VIEW
TOP VIEW
SIDE VIEW
Gas Connection/Electrical connections
if using optional Hardwire Kit.
Regency Plateau
®
PTO50 Outdoor Gas Fireplace | 7
7
|
dimensions
PTO100 (2 X PTO50 JOINED END TO END)
CHK
PROCESS :
SCALE:
DWN
BLANK SIZE :
SIGN
C.N.
DATE
THIS DRAWING IS THE PROPERTY OF FPI LTD., IT MAY NOT BE COPIED IN WHOLE OR IN PART, OR DISCLOSED TO A THIRD PARTY WITHOUT OUR PRIOR WRITTEN CONSENT.
CURRENT REVISION
PREVIOUS REVISION
PART :
MAT'L :
ANGULAR =
INSIDE BEND RADII =
UNITS IN INCHES
DIMENSIONS =
TOLERANCES UNLESS
OTHERWISE STATED
SCALE
DO NOT
PROJECTION
3RD ANGLE
MODEL #
QTY.
REV.
±1°
±0.031
PART
NO.
FIREPLACE PRODUCTS INTERNATIONAL
FEB 6 2017
SEE ABOVE
ASSEMBLY
-
646-515
ANDY MAH
646-515
WAYNE THURBER
PTO50 BURNER HOUSING
-
1:16
10 3/8"
263mm
8 1/4"
210mm
ADJUSTABLE
1/2" [13mm] TO 2-3/8" [60mm]
1 3/16"
OUTSIDE
OF UNIT TO
MOUNTING
HOLES
30mm
106 7/16"
2703mm
10 1/2"
267mm
MOUNTING HOLES
14"
356mm
TOP VIEW
SIDE VIEW END VIEW
Gas Connection/Electrical connections
if using optional Hardwire Kit.
8 | Regency Plateau
®
PTO50 Outdoor Gas Fireplace
|
8
installation
IMPORTANT MESSAGE
SAVE THESE
INSTRUCTIONS
The PTO50 Outdoor Decorative Gas Appliance must
be installed in accordance with these instructions.
Carefully read all the instructions in this manual
first. Consult the "authority having jurisdiction" to
determine the need for a permit prior to starting the
installation. It is the responsibility of the installer to
ensure this decorative gas appliance is installed in
compliance with manufacturers instructions and all
applicable codes.
BEFORE YOU START
Safe installation and operation of this appliance
requires common sense, however, we are required
by the Canadian Safety Standards and ANSI
Standards to make you aware of the following:
GENERAL SAFETY
INFORMATION
1. The installation must conform with local codes
or, in the absence of local codes, with CAN/CSA-
B149.1, Natural Gas and Propane Installation
Code or CAN/CSA-B149.2, Propane installation
code the Natural Gas Fuel Code, ANSI Z223.1/
NFPA 54.
2. See general construction and assembly instruc-
tions. The appliance should be enclosed.
3. Inspect the burner before each use of the appli-
ance for blockage and any signs of deterioration
CHILDREN AND ADULTS SHOULD BE
ALERTED TO THE HAZARDS OF HIGH
SURFACE TEMPERATURES, ESPE-
CIALLY THE DECORATIVE GAS APPLI-
ANCE GLASS AND FACEPLATE, AND
SHOULD STAY AWAY TO AVOID BURNS
OR CLOTHING IGNITION.
THIS APPLIANCE SHALL BE USED
ONLY OUTDOORS IN A WELL-VENTI-
LATED SPACE AND SHALL NOT BE
USED IN A BUILDING, GARAGE OR ANY
OTHER ENCLOSED AREA.
INSTALLATION AND REPAIR SHOULD
BE DONE BY AN AUTHORIZED
SERVICE PERSON. THE APPLIANCE
SHOULD BE INSPECTED BEFORE
USE AND AT LEAST ANNUALLY BY A
PROFESSIONAL SERVICE PERSON.
MORE FREQUENT CLEANING MAY
BE REQUIRED DUE TO EXCESSIVE
LINT FROM CARPETING, BEDDING
MATERIAL, ETC. IT IS IMPERATIVE THAT
CONTROL COMPARTMENTS, BURNERS
AND CIRCULATING AIR PASSAGEWAYS
OF THE APPLIANCE BE KEPT CLEAN.
ANY GUARD OR OTHER PROTECTIVE
DEVICE REMOVED FOR SERVICING
THE APPLIANCE MUST BE REPLACED
PRIOR TO OPERATING THE APPLIANCE
WARNING: FAILURE TO INSTALL THIS
APPLIANCE CORRECTLY WILL VOID
YOUR WARRANTY AND MAY CAUSE A
SERIOUS FIRE.
CLOTHING OR OTHER FLAMMABLE
MATERIAL SHOULD NOT BE PLACED
ON OR NEAR THE APPLIANCE.
DO NOT SIT OR STAND ON
DECORATIVE GAS APPLIANCE.
SOLID FUELS SHALL NOT BE BURNED
IN THIS APPLIANCE.
DO NOT USE THIS APPLIANCE IF
ANY PART HAS BEEN UNDER WATER.
IMMEDIATELY CALL A QUALIFIED
SERVICE TECHNICIAN TO INSPECT
THE APPLIANCE AND TO REPLACE
ANY PART OF THE CONTROL SYSTEM
AND ANY GAS CONTROL WHICH HAS
BEEN UNDER WATER.
YOUNG CHILDREN SHOULD BE CARE-
FULLY SUPERVISED WHEN THEY ARE
IN THE SAME AREA AS THE APPLI-
ANCE. TODDLERS, YOUNG CHILDREN
AND OTHERS MAY BE SUSCEPTIBLE
TO ACCIDENTAL CONTACT BURNS. A
PHYSICAL BARRIERS IS RECOMMEND-
ED IF THERE ARE AT RISK INDIVIDUAL
IN THE HOUSE. TO RESTRICT ACCESS
TO A DECORATIVE GAS APPLIANCE
OR STOVE, INSTALL AN ADJUSTABLE
SAFETY GATE TO KEEP TODDLERS,
YOUNG CHILDREN AND OTHER AT RISK
INDIVIDUALS OUT OF THE ROOM AND
AWAY FROM HOT SURFACES.
4. To prevent injury, do not allow anyone who is
unfamiliar with the operation to use the decora-
tive gas appliance.
5. Wear gloves and safety glasses for protection
while doing required maintenance.
6. Maximum gas inlet pressure = 1/2 psig.
7. Under no circumstances should this appliance
be modified. Parts that have to be removed for
servicing should be replaced prior to operating
this appliance.
8. Installation and any repairs to this appliance
should be done by a qualified service person.
A professional service person should be called
to inspect this appliance annually. Make it a
practice to have all of your gas appliances
checked annually.
9. Under no circumstances should any solid fuels
(wood, paper, cardboard, coal, etc.) be burned
in this appliance.
10. The appliance and its individual shutoff valve
must be disconnected from the gas supply
piping system during any pressure testing of
that system at test pressures in excess of 1/2
psi (3.5kPa).
11. The appliance area must be kept clear and free
of combustible materials, gasoline, and other
flammable vapors and liquids.
It is highly recommended to protect the interior
from moisture (rain, snow). Cover the enclosure
opening when not in use. This decorative gas
appliance is only for use with the type of gas
indicated on the rating plate. This decorative gas
appliance is not convertible for use with other
gases, unless a certified kit is used.
12. When not using appliance for extended periods
of time - turn off gas supply.
13. Do not operate this appliance with a remote
control. Only use the ON/OFF switch supplied
with this appliance. The ON/OFF switch must
be placed within line of sight of the appliance.
Regency Plateau
®
PTO50 Outdoor Gas Fireplace | 9
9
|
installation
LOCATING YOUR
OUTDOOR DECORATIVE GAS APPLIANCE
1. When selecting a location for your decorative gas appliance, ensure that the clearances are met.
2. This appliance must be installed in an open-air situation with natural ventilation, without stagnant
areas, where gas leakage and products of combustion are rapidly dispersed by wind and natural
convection.
3. Certain materials or items, when placed under or near the appliance, will be subjected to radiant
heat and could become damaged.
4. Typically an outdoor space is not enclosed but, any enclosure in which the appliance is used shall
comply with one of the following:
An enclosure with walls on all sides, but at least one permanent opening at ground level and no
overhead cover.
Within a partial enclosure that includes an overhead cover and no more that two walls.
Within a partial enclosure that includes an overhead cover and more than two walls, the following
shall apply:
At least 25% of the total wall area is completely open, and
At least 30% of the remaining wall area is open and unrestricted
INSTALLATION
CHECKLIST
If installing a PTO100 or a PTO80, you must
repeat steps 2 - 5 for both units.
1. Locate appliance:
a) Refer to "Locating Your Outdoor decorative
gas appliance" section
b) Clearances to Combustibles (Refer to
"Clearances" section)
c) Framing & Finishing Requirements (Refer
to "Framing & Finishing" section)
2. Drain Installation (recommended).
3. Install ON/OFF switch - ensure it is in the OFF
position.
4. Make gas connections - test for leaks.
5. Install 4 "AA" batteries into each battery pack.
This unit will not operate without AA batteries
in place. An optional hard wire kit can also be
installed which eliminates the need for the 4 AA
batteries. Batteries would only be used as back
up if power was lost.
6. Install standard and optional features. Refer to
the following sections:
a. Glass Crystals
b. Volcanic Stone Installation (optional)
c. Log Installation (optional)
d. Glass Surround Installation (optional)
e. Hardwire kit (optional)
f. LP conversion kit (optional)
g. Burner cover (optional)
h. Inner stainless trim (optional)
7. Final check.
This includes:
1. Clocking the appliance to ensure the correct
firing rate (rate noted on label), after burning
appliance for 15 minutes.
2. If required, adjusting the primary air to ensure
that the flame does not carbon. First allow the
unit to burn for 15-20 min. to stabilize.
CAUTION: Any alteration to the product that
causes sooting or carboning that results in dam-
age is not the responsibility of the manufacturer.
30% or more in total of the remaining wall
area is open and unrestricted.
Open side at least 25% of total wall area
*SEE IMPORTANT INSTALLATION NOTES NEXT PAGE
10 | Regency Plateau
®
PTO50 Outdoor Gas Fireplace
|
10
installation
Never insulate around the body of the unit
Excessive heat retention in the firebox will lead to component failure
and fireplace malfunction
Excessive heat retention will also increase the risk of fire inside the
chase
Heat retention can cause “Oil-canning” and damage the fireplace due
to overheating
Do not build up a wall of any type in front or to the sides of the appli-
ance, higher than the firebox opening. This will create a pressure zone
at the firebox and will prevent the unit from venting
This is an outdoor appliance with a built-in drain. This drain should be
installed and connected in all applications as per the instructions in
this manual
Inadequate drainage will cause rust and reduce the life of your appli-
ance, this is not protected by warranty
Outdoor units use the same consistent, reliable Electronic components
used in most Regency “E” units
Installed correctly, these components will be subjected to far lower
temperatures than indoor units, which have been certified as safe from
heat etc
Working gas pressures are as critical in outdoor products as they are
in indoor products, even more important in Electronic systems
Unit shutting down intermittently
Overheating of components leading to failure
Lifting flame
Poor flame package (i.e. all to one side, lazy flame)
Failure to ignite
Excess carbon
Safety issues and concerns created from the byproducts of combus-
tion
Outdoor appliances must be installed in: open-air situations with natu-
ral ventilation and without stagnant areas
Any gas leakage and products of combustion need to be rapidly dis-
persed by wind and natural convection
Typically outdoor spaces are not enclosed, however, failure to adhere
to installation guidelines, may cause the outdoor fireplace to be af-
fected by wind or air pressure inside the enclosure
ANY enclosure in which the appliance is used shall comply with one of
the diagrams on the previous page.
All walls + overhead cover = 100% total area
One of four walls or full overhead area must be totally open, plus—one
of remaining walls must have a fixed opening
All outdoor fireplaces/fire tables require total natural ventilation of 50%
open space
Correct Working Gas pressure is critical on “E” units
Wherever possible avoid locating on a flat wall in a tight corner
Floor space doesn’t count as “open area”
Install to the manual specs for framing and do not insulate unit or
enclosure
Framing enclosure must at least meet minimum dimensional specs as
per the installation manual
Only Regency approved media should be used in the firebox (i.e.
stones/glass)
Be aware of pressure zones due to location (i.e. facing the ocean)
Open walls and doorways to outside air are beneficial to the perfor-
mance of an outdoor appliance
Fixed roof/ceiling open areas count towards the total open area overall
requirement
Screens create 40% or more air restriction
Screened areas are restrictions and reduce open air space, calculate
area based on a closed screen
The biggest problems are created by lack of airflow for the appliance
Outdoor fireplaces are often built-in systems and incorrect installation
can result in high repair costs
Units must not be modified or altered in any way
There is a common misconception that being outdoors, an Outdoor
Fireplace will function, regardless of circumstances,
Outdoor fireplaces require the same amount of ventilation as indoor
units, often more
Outdoor units require adequate ventilation to the atmosphere, which in
turn provides ongoing circulatory combustion air
This type of Appliance Vents.
All Outdoor Fireplace Products have the same need for Air/Oxygen,
and an ability to Vent
Even though the appliance is outdoors, this doesn’t mean it is getting
adequate air
Requirements are not specific to Regency units
Read and follow critical location guidelines in this manual
Don’t overlook the obvious
Widen your margin for error
Combustion always requires the same three elements
Only the quantities and volumes change
IMPORTANT INFORMATION FOR OUTDOOR FIREPLACE INSTALLATIONS
IMPORTANT THINGS TO REMEMBER
ANTICIPATED ISSUES CAUSED BY
INCORRECT LOCATION OR INSTALLATION
OUTDOOR APPLIANCES REQUIRE VENTING
COMPONENTS IN OUTDOOR APPLIANCES
COMMON MISCONCEPTIONS REGARDING
OUTDOOR FIREPLACES
UNDERSTANDING OUTDOOR APPLIANCE
REQUIREMENTS
OUTDOOR APPLIANCE INSTALLATION SUMMARY
Regency Plateau
®
PTO50 Outdoor Gas Fireplace | 11
11
|
installation
Caution Requirements
The top, back and sides of the decorative gas appliance
are defined by standoffs. The metal ends of the
standoff may NOT be recessed into combustible
construction.
WARNING
Fire hazard is an extreme risk
if these clearances (air space) to combustible materials are not
adhered to. It is of greatest importance that this decorative gas
appliance be installed only in accordance with these instructions.
MINIMUM CLEARANCES TO COMBUSTIBLES
The clearances listed below are minimum distances unless otherwise stated.
A major cause of fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this
decorative gas appliance be installed only in accordance with these instructions.
PTO50, PTO80 or PTO100 Clearance Requirements
Alcove
C
A
B
D
E1
B
D
C
A
E2 or E3
Clearances Dimension Measured From:
A: Back wall
18" (457mm) Burner to back wall
B: Sidewall
17" (432mm) Burner to sidewall
C: Ceiling
45" (1143mm) Burner to Ceiling
D: Unit Base
1"(25mm) Unit Base to Combustible
E1: Alcove Width
E2: Alcove Width (PTO80)
E3: Alcove Width (PTO100)
91"(2311mm)
121" (3074mm)
141" (3581mm)
Wall to Wall (Minimum)
F: Alcove Depth
60" (1524mm) Front to Back Wall (Maximum)
Notes:
0" No Hearth Required
Clearances shown are to both combustible/non combustible material.
E / E1 / E2
F
12 | Regency Plateau
®
PTO50 Outdoor Gas Fireplace
|
12
installation
INNER FRAMING DIMENSIONS (REQUIRED)
NOTE:FRAMING MATERIAL NOT SUPPLIED
56 3 4 1441-/" ( mm)
TOP VIEW
SIDE VIEW
END VIEW
81 216-/" (2 mm)
8 1 2 16- / " (2 mm)
11 3 89- /8" (2 mm)
56 3 4 1441-/" ( mm)
NOTE: Framing materials must be non-combusti-
ble when used within 5" of the unit.
Combustible framing materials may be
used outside the 5" clearance range.
Note: The PTO30 non combustible clearance
is 4", although when combining it with a
PTO50 to make a PTO80 the clearance
will be 5".
Finishing materials MUST be non-combustible.
Consideration should be given to weather /
elements when choosing framing materials (ie.
treated lumber, steel stud).
PTO80
PTO50
NOTE: PTO50 - Two (2) ventilation grills are required for all enclosures. The ventilation grill(s) must be placed at either end as shown to allow the air to
circulate from one end to the other.
This is to alleviate moisture and allow for air to circulate. Minimum recommended size 20" sq (508 mm²) ea.
The ventilation grills must be located at the ends of the burner as shown.
NOTE: PTO80 - Four (4) ventilation grills are required for all enclosures. The ventilation grill(s) must be placed at either end as shown to allow the air to
circulate from one end to the other.
This is to alleviate moisture and allow for air to circulate. Minimum recommended size 20" sq (508 mm²) ea.
The ventilation grills must be located at the ends of the burner as shown.
Vent Grill
Location
Vent Grill
Location
Vent Grill
Location
Vent Grill
Location
END VIEW
81 216-/" (2 mm)
11 3 89- /8" (2 mm)
90 2286" ( mm)
8 1 2 16- / " (2 mm)
90 2286" ( mm)
TOP VIEW
SIDE VIEW
Vent Grill Location
Vent Grill
Location
Vent Grill
Location
Vent Grill
Location
Vent Grill Location
Vent Grill
Location
Regency Plateau
®
PTO50 Outdoor Gas Fireplace | 13
13
|
installation
106 34 2711-/" ( mm)
END VIEW
8- / " (2 mm)1 2 16
SIDE VIEW
11 3 89- /8" (2 mm)
TOP VIEW
106 34 2711-/" ( mm)
81 216-/" (2 mm)
PTO100
NOTE: PTO100 - Four (4) ventilation grills are required for all enclosures. The ventilation grill(s) must be placed at either end as shown to
allow the air to circulate from one end to the other.
This is to alleviate moisture and allow for air to circulate. Minimum recommended size 20" sq (508 mm²) ea.
The ventilation grills must be located at the ends of the burner as shown.
Vent Grill
Location
Vent Grill Location
Vent Grill Location
Vent Grill Location
Vent Grill Location
Vent Grill Location
14 | Regency Plateau
®
PTO50 Outdoor Gas Fireplace
|
14
installation
1
PTO30/PTO50 OUTDOOR SERIES
920-390 04.09.21
PTO30/PTO50 - Two (2) ventilation grills are required for all enclosures. The ventilation grill(s) must be placed at either end as shown to allow the air
to circulate from one end to the other. This is to alleviate moisture and allow for air to circulate. Minimum recommended size 20" sq (508 mm²) ea.
PTO60/PTO80/PTO100 - Four (4) ventilation grills are required for all enclosures. Two (2) upper and two (2) lower ventilation grills are required for
all enclosures.
This is to alleviate moisture and allow for air to circulate. Minimum recommended size: 20" sq. (508 mm²) ea.
If using the grills offered by Regency (supplied), follow the instructions noted below:
Frame the opening for the upper vent at 16" x 1-1/4" - secure the upper vent to the framing with 6 screws.
Frame the opening for the lower vent at 8" x 2-7/8" - secure the lower vent with 10 screws.
We highly recommend installing these upper (PTO60/PTO80/PTO100) and lower grills (PTO30/PTO50/PTO60/PTO80/PTO100) at either end of the
framed structure to allow the air to circulate from one end to the other.
Note: If purchasing grills elsewhere, ensure the minimum recommended size of 20"sq. (508 mm²) each is met.
PTO30/PTO50 Optional grills Includes 2 x 377-061 Lower vent (Kit part # 377-946)
PTO60/PTO80/PTO100 Optional grills Includes 2 x 377-061 Lower vent & 2 x 377-060 Upper Vent (Kit part # 377-948)
PTO30/PTO50 ENCLOSURE VENT INSTALLATION
Upper vent
# 377-060
Lower vent
# 377-061
Flange
Flange
Note: Finishing material can be brought over the flange of the ventilation grills to ensure a clean look.
Upper Vent
Grill
Lower Vent
Grill
Upper Vent
Grill
Lower
Vent Grill
ENCLOSURE VENT INSTALLATION
Regency Plateau
®
PTO50 Outdoor Gas Fireplace | 15
15
|
installation
FINISHING
Side nailing strips are adjustable for material from a minimum of 1/2" thick
up to a maximum of 2-3/8" thick.
The finishing materials cannot extend beyond the height of the burner.
Optional finishing trim is not supplied with the PTO50 - if purchased, place finishing trim on unit between unit and finishing material.
Note: Optional trim is not available for the PTO80 and PTO100.
Side nailing strips are adjustable in 1/4" or 1/8" increments. Each hole on
the inside line is 1/8", each hole on the outside line is 1/4"
Determine the thickness of the finishing material before adjusting the nailing
strips.
OPTIONAL FINISHING TRIM
1/2"
1/4" Increments
1/8" Increments
2-3/8"
Nailing strip
FINISHING MATERIALS:
This burner is designed to be finished with non-combustible materials (ie.
tile, granite, marble, brick, etc.) with a minimum thickness of 1/2" to a maxi-
mum thickness of 2-3/8".
Burner Opening Size
PTO0 6- " x 8- "557/8 5/8
80 90-1/8 5/8PTO" x 8- "
PTO0 6- " x 8- "10 10 7/8 5/8
Min. 1/2"
Max. 2-3/8"
Important Note: Two (2) ventilation grills, (PTO50), Four (4) ventilation
grills (PTO80 & PTO100) are highly recommended for all enclosures.
This is to alleviate moisture and allow for air to circulate.
Minimum recommended size : 20" sq (508 mm ²) each.
The ventilation grills must be located at the ends of the burner.
16 | Regency Plateau
®
PTO50 Outdoor Gas Fireplace
|
16
installation
GAS PIPE PRESSURE
TESTING
The appliance must be isolated from the gas sup-
ply piping system by closing its individual manual
shut-off valve during any pressure testing of the
gas supply piping system at test pressures equal
to or less than 1/2 psig. (3.45 kPa). Disconnect
piping from valve at pressures over 1/2 psig.
The manifold pressure is controlled by a regulator
built into the gas control, and should be checked
at the pressure test point.
Note: To properly check gas pressure, both
inlet and manifold pressures should be
checked using the valve pressure ports
on the valve.
1. Make sure the valve is in the "OFF" position.
2. Loosen the "IN" and/or "OUT" pressure tap(s),
turning counterclockwise with a
1/8" wide flat screwdriver.
3. Attach manometer to "IN" and/or "OUT" pressure
tap(s) using a 5/16" ID hose.
4. Light the pilot and turn the valve to "ON" position.
5. The pressure check should be carried out with
the unit burning and the setting should be within
the limits specified on the safety label.
6. When finished reading manometer, turn off the
gas valve, disconnect the hose and tighten the
screw (clockwise) with a 1/8" flat screwdriver.
Note: Screw should be snug, but do not over
tighten.
AERATION ADJUSTMENT
The burner aeration is factory set but may need
adjusting due to either the local gas supply or
altitude. Open the air shutter for a blue flame or
close for a more yellow flame.
Minimum Air Shutter Opening:
Fully Closed NG
1/4" LP
See LP conversion instructions (Steps 1-3 & 8) in
this manual for aeration adjustment instructions.
Note: Any damage due to carboning resulting
from improperly setting the aeration
controls is NOT covered under warranty.
HIGH ELEVATION
This unit is approved for altitude 0 to 4500 ft. (CAN/
CGA 2.17-M91).
GAS LINE
INSTALLATION
Since some municipalities have additional local
codes it is always best to consult with your local
authorities and the CAN/CGA B149 installation
code.
For USA installations follow local codes and/or the
current National Fuel Gas Code, ANSI Z223.1.
When using copper or flex connectors use only
approved fittings. Always provide a union so that
gas lines can be easily disconnected for servicing.
Flare nuts for copper lines and flex connectors are
usually considered to meet this requirement.
NOTE: A shutoff / dante valve should be sup-
plied in or near the unit (or as per local codes)
for ease of servicing this appliance.
IMPORTANT: Always check for gas leaks with
a soap and water solution or gas leak detector.
Do not use open flame for leak testing.
PTO50-NG11 SYSTEM DATA
Max. Supply Pressure 14" WC (3.49 kPa)
Min. Supply Pressure 5" WC (1.25 kPa)
Manifold Pressure 3.5" WC (0.87 kPa)
Manifold Pressure -Low 1.6" WC (0.40 kPa)
Orifice Size #11 DMS
Minimum Input 42,000 Btu/h
(12.31 kW)
Maximum Input 64,000 Btu/h
(18.76 kW)
PTO50-LP11 SYSTEM DATA
Max. Supply Pressure 14" WC (3.49 kPa)
Min. Supply Pressure 11" WC (2.73 kPa)
Manifold Pressure 10" WC (2.49 kPa)
Manifold Pressure-Low 6.4" WC (1.59 kPa)
Orifice Size #42 DMS
Minimum Input 49,000 Btu/h
(14.36 kW)
Maximum Input 62,000 Btu/h
(18.17 kW)
Note: If you have an incorrect flame pattern,
contact your Regency
®
dealer for further
instructions.
Incorrect flame pattern will have small, probably
yellow flames, not coming into proper contact
with the rear burner or flame sensor.
Burner
Flame Sensor
Pilot
Ignitor
PILOT ADJUSTMENT
Periodically check the pilot flames. Correct flame
pattern has two strong blue flames: 1 flowing
around the flame sensor and 1 flowing across
the burner (it does not have to be touching the
burner).
886 S.I.T. VALVE
DESCRIPTION
1) Manual high/low adjustment
2) Pilot adjustment
3) Outlet Pressure Tap
4) Inlet Pressure Tap
5) Pilot Outlet
6) Main Gas Outlet
7) Main Gas Inlet
1
3
2
4
5
6
7
1
3
2
4
5
6
7
NOTE:
The two PTO50s have a combined minimum input
of 84,000 Btu - NG/ 98,000 Btu - LP and max.
input of 128,000 Btu - NG / 124,000 Btu - LP. Care
should be taken when sizing the gas pipe due to
the extremely high Btu of this unit.
Regency Plateau
®
PTO50 Outdoor Gas Fireplace | 17
17
|
installation
JOINING TWO UNITS END TO END
NOTE: Two PTO50s or a PTO50 and PTO30 can be assembled end to
end. You must purchase the two units individually.
1 Remove the large stand off on the end of the unit from both PTO50s
units - by removing 2 screws per side.
4. Line the two units up end to end. Screw fireboxes together (one from
each side).
5. Reinstall burner trays.
6. Install units together into framing (refer to framing section). Secure in
place with nailing strips.
Large standoff
PTO30
3. Lift burner tray off-burner tube can remain in place.
2. Remove 22 screws (PTO50) or 9 screws (PTO30) in locations shown
below to remove burner tray (remove from both units).
PTO50
Note: To balance the flame, the PTO30 manifold pressure will
need to be adjusted to the following:
PTO30-NG Natural Gas - 1.6"WC
PTO30-LP Propane - 8"WC
Refer to "Valve Assembly Replacement" in the PTO30 manu-
al to access valve regulator.
18 | Regency Plateau
®
PTO50 Outdoor Gas Fireplace
|
18
installation
CONVERSION FROM NG TO LP
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
IF IN DOUBT DO NOT DO THIS CONVERSION !!
1
OUTDOOR SERIES
919-767
04.08.21
CONVERSION FROM NG TO LP
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
IF IN DOUBT DO NOT DO THIS CONVERSION !!
Each Kit #646-969 contains one LP Conversion Kit
Conversion Kit Contains:
Qty. Part # Description
1 904-430 Burner Orifice #42
1 904-529 5/32" Allen Key
1 908-528 Red "LP" label
1 911-009 Hi/Lo conversion LP For 886
1 910-101 Pilot Orifice LP
1 918-590 Decal "Converted to LP"
1 919-767 Instruction Sheet
1. Remove glass crystals and log set, if installed.
2a. Locate and remove 22 screws to remove the burner tray.
Turn the unit off and allow to cool to room temperature.
Turn off gas supply.
Pilot Cap
Burner orifice
3. Remove 2 screws and slide burner tube to the left (away from the orifice)
to remove.
4. Remove burner orifice with a 1/2" wrench. Use another wrench to
hold on to the elbow behind the orifice. Discard orifice.
Install new LP #42 burner orifice supplied with kit.
6. Pull off the pilot cap to expose the pilot orifice. Using a 5/32" allen
key, remove pilot orifice and replace with LP pilot orifice.
5. Remove the wire clip below the pilot cap.
2b. Remove 2 screws to remove the burner end (see below).
Pilot retainer clip
Regency Plateau
®
PTO50 Outdoor Gas Fireplace | 19
19
|
installation
OUTDOOR SERIES
919-767
04.08.21
11. Attach the label “This unit has been converted to LP” near or on top
of the serial # decal.
12. Replace yellow “NG” label with red “LP” label.
Make appropriate gas connections.
10. Remove Hi/Lo pressure regulator by removing 2 screws as shown below.
Reverse steps to install LP pressure regulator. (Be sure diaphragm
and spring are removed from the original regulator.)
13. Reverse Steps 1-6
14. Check all gas connections under normal operating pressure, for leaks,
with soapy water.
NOTE: If soap bubbles, this would indicate a gas leak.
15. Check inlet and outlet pressures.
16. Check operation of flame control.
HI/LO Pressure
Regulator
7. Re-install pilot cap.
8. Adjust air shutter to 1/4 inch open by loosening the screw on the air shutter.
Retighten screw after adjustment.
9. Remove 8 screws on valve access cover.
20 | Regency Plateau
®
PTO50 Outdoor Gas Fireplace
|
20
installation
WALL SWITCH AND BATTERY INSTALLATION
(INCLUDED WITH UNIT)
919-776
08/15/11
1
OUTDOOR SERIES
WALL SWITCH INSTALLATION
(INCLUDED WITH UNIT)
The unit comes with low voltage wire and a battery extension wire installed.
1. Run supplied wire to desired location - to a maximum of 9 feet.
2. Install supplied electrical box in desired location.
3. Remove center knock out from electrical box and install strain relief (strain
relief nut not required).
4. Route low voltage wire and battery extension wire through the strain relief.
5. Connect low voltage wire to supplied switch, fasten switch to right side of
electrical box (polarity not important).
7. Using silicone, completely seal strain relief to protect from water or moisture.
8. Place supplied gasket on top of electrical box.
9. Fasten cover to electrical box using supplied screws.
10. Place switch in <OFF> position until nal installation is complete.
Center knock out
Strain Relief
6. Install supplied 4-AA batteries into the battery holder. Using velcro install
battery holder to the backside of the battery compartment door. Connect
battery terminal.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56

Regency Fireplace Products Plateau PTO50 Owner's manual

Category
Fireplaces
Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI