American Standard 775B103.002 Installation guide

Category
Sanitary ware
Type
Installation guide
1
M965754 Rev. 1.7 (7/18)
© 2018 AS America Inc.
Installation Instructions
Certied to comply with ASME A112.18.1
© 2018 AS America, Inc.
NOTE TO INSTALLER: Please give this manual to the customer after installation.
To learn more about American Standard Selectronic
®
Products visit our website at: www.americanstandard-us.com
or e-mail us at: CRTTEAM@lixilamericas.com
For Parts, Service, Warranty or other Assistance,
please call (844) CRT-TEAM / (844) 278-8326 (In Canada: 1-800-387-0369)
(In Toronto Area only: 1-905-306-1093)
NextGen Selectronic
®
Integrated Faucet with Optional Above-Deck
Mixing & SmarTherm
®
Temperature Limiter
MODEL NUMBERS
7755.1xx 775B.1xx
7755.2xx 775B.2xx
7755.3xx 775B.3xx
CAUTION: Use only American Standard supplied
transformers and cable sets. Using non-AS supplied
cables, or cutting, splicing or modifying any components
will void the warranty.
Product No’.s & Options 2
Specications 3
Faucet Installation 3
Electrical Installation 4-5
FAQ’s / Troubleshooting 9
Parts 10
Start-up / Maintenance 6-8
2
M965754 Rev. 1.7 (7/18)
Thank you for selecting American-Standard...the benchmark of ne quality for over 100 years. To ensure that your
installation proceeds smoothly--please read these instructions carefully before you begin.
Remove the tting and loose items from the carton. The illustration below shows all the ttings and loose items after they
have been removed from the carton. Some items may be packaged partially assembled to other items.
UNPACKING
All American Standard Products Are Water Tested At Our Factory.
Some Residual Water May Remain In The Valve During Shipping.
1. Installation Instructions
2. Spout Assembly (less mixing)
2a. Spout Assembly (mixing)
3. Mounting Kit
4. 4" and 8" Deck plate (optional,
must be ordered separately)
5. Thermostatic Mixing Valve (optional, must be ordered separately)
6. Inline Filter/Check Valve Assembly
7. Assembly Parts
8. Battery Back-Up Unit (optional, must be ordered separately)
775P.400 775P.800
4
Deck Plate
Plug-In AC
Power Kit
Hard-Wired AC
Power Kit
Multi-AC
Power Kit
PWRX
Power Kit
PK00.PACPK00.WRK
PK00.HAC PK00.MAC
PK00.BBU
Battery
Back-Up
Kit
8
POWER KITS SOLD SEPARATELY
605XTMV1070
5
Mixing Valve
3
2
6
6
2a
DO NOT REMOVE
PROTECTIVE
FILM FROM
SENSOR EYE UNTIL
INSTALLATION IS
COMPLETE.
DO NOT REMOVE
PROTECTIVE
FILM FROM
SENSOR EYE UNTIL
INSTALLATION IS
COMPLETE.
7
1
1
© 2016 AS America Inc.
Inst a lla t io n Inst r u ctions
© 2016 AS America, Inc.
NOTE TO INSTALLER: Please give this manual to the customer after installation.
To learn more about American Standard Selectronic
®
Products visit our website at: www.americanstandard-us.com
or e-mail us at: CRTTEAM@americanstandard.com
For Parts, Service, Warranty or other Assistance,
please call (844) CRT-TEAM / (844) 278-8326 (In Canada: 1-800-387-0369)
(In Toronto Area only: 1-905-306-1093)
NextGen Selectronic
®
Integrated Faucet with Optional Above-Deck
Mixing & Temperature Limiter
MODEL NUMBERS
7755.1xx 775B.1xx
7755.2xx 775B.2xx
7755.3xx 775B.3xx
M965754 (8/16)
CAUTION: Use only American Standard supplied
transformers and cable sets. Using non-AS supplied
cables, or cutting, splicing or modifying any components
will void the warranty.
Product No’.s & Options 2
3
Faucet Installation 3
Electrical Installation 4-5
FAQ’s / Troubleshooting 9
Parts 10
Start-up / Maintenance 6-8
3
M965754 Rev. 1.7 (7/18)
1
SPOUT ASSEMBLY
INSTALLATION; Fig. 1
1. Make sure O-RING (1) is installed in spout base.
IMPORTANT: Do not use putty when installing faucet
without escutcheon.
2. If installing DECK PLATE (2) (optional): Apply a bead
of putty to bottom edge of PUTTY PLATE (2). Install
SCREW (11) into the MOUNTING BASE OF THE
FAUCET (13) and allign SCREW (11) with HOLE (12).
3. Insert SUPPLY HOSES (3), SHANK (4) and SENSOR
CABLE (5) (only included in base model) through hole
in DECK PLATE with PUTTY PLATE (2) and mounting
surface.
4. Assemble RUBBER WASHER (7), BRASS WASHER (8)
and THREADED LOCKNUT (9) onto SHANK (4) from
underside of sink or mounting surface. Hand tighten
LOCKNUT (9).
5. Use a screwdriver to tighten SCREWS (10) on
LOCKNUT (9). Work your way around LOCKNUT (9),
tightening the screws slightly each time until all are
snug to ensure even pressure.
Roughing-in Dimensions
1. 2.5 mm Hex Wrench
(Included)
2. Adjustable Wrench
3. Plumbers Putty or Caulking
4. Flat Blade Screwdriver
5. Tape Measure
6. 2.0 mm Hex Wrench
(Included)
RECOMENDED CONTROL BOX OR
EQUIVALENT BY OTHERS
4" (102mm) SQ. X 2-1/2" (64mm) DEEP 2-GANG ELECTRICAL
BOX Appleton #4SD1 OR EQUAL (BY OTHERS).
(Used with Hard-Wired AC Transformer)
CLEARANCE
25 mm (min)
(1" min)
FINISHED WALL
OR BACKSPLASH
126 mm
(5")
146 mm
(5-3/4")
48 mm
(1-7/8")
28 mm
(1-1/8")
3/8" COMPRESSION
CONNECTORS
174 mm
(6-7/8")
125 mm
(4-15/16")
38 mm
(1-1/2")
597 mm
(23-1/2")
39 mm
(1-1/2")
61 mm
(2-7/16")
Note: All plumbing and electrical wiring must be installed in
accordance with applicable codes, regulations and standards.
CAUTION: Use only American Standard
supplied transformers and cable sets.
Using non-AS supplied cables, or cutting,
splicing or modifying any components
will void the warranty.
RECOMMENDED TOOLS
CAUTION
Turn off hot and cold water
supplies before beginning
Fig. 2
1
2
3
4
5
10'
6
Fig. 1
10
PUTTY
(If required)
MOUNTING
SURFACE
(OPTIONAL)
TIGHTEN
SPIN NUTS
2
1
4
12
13
3
7
8
9
5
I
MPORTANT: Do not
use putty when installing
faucet without escutcheon.
IMPORTANT: Do not
use sealent on threads
11
M965754 Rev. 1.7 (7/18)
4
ELECTRICAL INSTALLATION
Product Page
PWRX Power Kit
(PK00.WRK)
4
Plug-In AC Power Kit (PK00.PAC)
5
Hard-Wired AC Power Kit (PK00.HAC)
5
Multi-AC Power Kit (PK00.MAC)
5
Important: All product with standard battery come
with electrical connections preaseambled at the
factory. No further action necessary.
A
PWRX 10 YEAR BATTERY
SYSTEM; Fig. 1
PWRK
VERSION;
1. Connect PWRX BATTERY PACK (1) to SENSOR
CABLE (2).
2. Secure the connections by installing into CONNECTOR
LOCKING DEVICE (3) as shown. Rotate the END CAPS
(4) to secure the connection within the CONNECTOR
LOCKING DEVICE (3).
3. Determine the mounting location of the PWRX BATTERY
PACK (1) by marking center lines as shown.
4. Place the BRACKET (5) on the horizontal center line
and mark the location of the mounting holes to be drilled.
5. Using 1/4" diameter drill bit, drill two mounting holes
aproximately 1" deep.
6. Install the two ANCHORS (6) provided into the mounting
holes.
7. Place the BRACKET (5) over the ANCHORS (6)
and secure with the SCREWS (7) provided.
Do not overtighten.
8. Insert PWRX BATTERY PACK (1) into BRACKET (5).
7
6
5
VERTICAL
C/L
HORIZONTAL
C/L
1
BRACKET INSTALLATION
Fig. 1
1
3
2
3
4
4
M965754 Rev. 1.7 (7/18)
5
CAUTION: Use only American Standard supplied transformers
and cable sets. Using non-AS supplied cables, or cutting,
splicing or modifying any components will void the warranty.
B
AC VERSIONS (HARD-WIRED /
PLUG-IN POWER SUPPLY); Fig. 2
Important: Turn off power to outlet or electrical box.
FOR PLUG-IN VERSION;
1. Connect PLUG-IN AC POWER SUPPLY (2) to one end of
the SINGLE AC ADAPTER (6).
2. Connect SENSOR CABLE (4) to the other end of the
SINGLE AC ADAPTER (6).
3. Connect PLUG-IN AC POWER SUPPLY (2) to wall outlet.
FOR HARD-WIRED VERSION;
1. Connect HARD-WIRED AC TRANSFORMER (3) to
AC-DC CONVERTER (7).
2. Connect 10’ EXTENSION CABLE (1) to AC-DC
CONVERTER (7).
3. Connect SENSOR CABLE (4) to the other end of the
10' EXTENSION CABLE (1).
4. Make Black and White power line connections to
HARD-WIRED AC TRANSFORMER (3) and mount on
ELECTRICAL BOX (5).
Fig. 2
6
4
2
3
5
1
1
WALL
OUTLET
4" CONTROL BOX
OR EQUIVALENT BY
OTHERS (6)
BLACK & WHITE
POWER
CONNECTIONS
10' EXTENSION
7
AC-DC
CONVERTER
Unit #1
(Already Installed)
Fig. 3
Unit #2 Unit #3 Unit #4
1
2
4
3
MAXIMUM OF 15 UNITS PER TRANSFORMER.
10' MAXIMUM CABLE LENGTH BETWEEN UNITS.
BLACK & WHITE
POWER
CONNECTIONS
C
MULTI-AC VERSION (DAISY-CHAIN); Fig. 3
Important: Disconnect the rst units Multi-AC Adapter from power supply before making daisy-chain connections.
Note: For Unit #1 electrical instructions, refer to Figure 2 (above).
For subsequent Units, refer to instructions below...
1. Connect one end of the 10' EXTENSION (1) to the available terminal of the previous unit’s MULTI-AC ADAPTER (2), and
the other end to the single terminal of the current unit’s MULTI-AC ADAPTER (3).
2. Connect SENSOR CABLE (4) to either of the two available terminals of MULTI-AC ADAPTER (3).
3. Repeat Steps above for each additional Unit, for a Max. of 15 Units on one AC POWER SUPPLY.
Do not connect power to transformer
until installation of faucet is complete.
Recommended Electrical Box or Equivalent
by others 4” (102mm) SQ. X 2-1/2” (64mm)
DEEP 2-GANG ELECTRICAL BOX Appleton
#4SD1 OR EQUAL (BY OTHERS).
6
M965754 Rev. 1.7 (7/18)
D
MAKE WATER SUPPLY
CONNECTIONS; Fig. 4
1. Turn off hot and cold water supplies before beginning.
2. Install INLINE FILTER (3) on each wall supply outlet. Be sure that
INLINE FILTER (3) is inserted in the correct direction.
(See Illustration)
3. Connect HOT FLEXIBLE SUPPLY (marked with red stripe) (1) to
INLINE FILTER (3) on hot water control stop (4). Connect COLD
FLEXIBLE SUPPLY (marked with blue stripe) (2) to INLINE FILTER
(3) on cold water control stop (5). Use adjustable wrench to tighten
connections. Do not over tighten.
4. Faucet supplies are 24" long from faucet base.
Note; If additional supply length is required, installer must
purchase those parts separately.
Important; If SUPPLY HOSES (1, 2) are too long, loop as
illustrated to avoid kinking.
Fig. 4
Fig. 5
DETECTION
ZONE
PROTECTIVE FILM
IMPORTANT: Do not
use sealent on threads
1
2
3
COLD
HOT
(3) INLINE
FILTER
Fig. 1
Installation Instructions
(In Toronto Area only: 1-905-3061093)
SELECTRONIC™
Thermostatic Mixing Valve
Certified to comply with ASME A112.18.1M
© 2005 American Standard
M968808
To learn more about American Standard Faucets visit our website at: www.us.amstd.com or U.S.
customer's e-mail us at: [email protected]
For Parts, Service, Warranty or other Assistance,
please call
1-800-442-1902 (In Canada: 1-800-387-0369)
NOTE TO INSTALLER: Please give this manual to the customer after installation.
(In Toronto Area only: 1-905-3061093)
605XTMV
Specifications
Installation
Adjust Temperature
Service
Replacement Parts
1
2
3
3
4
No. M968808
HOT
SUPPLY
COLD
SUPPLY
TEE
FITTING
Optional Mixing Valve
(Sold Separately)
TEMPERED
WATER SUPPLY
COLD
WATER
5
4
Fig. 6
1
9
8
7
5
3
E
INSTALL OPTIONAL MIXING VALVE; Fig. 5
Note: An optional Thermostatic Mixing Valve (sold separately) may
be installed on faucets 775X.1XX & 775X.2XX in addition to Above
Deck Mixing valve. See setup diagram Fig. 5.
Te e tting is not supplied with Faucet or Thermostatic Mixing valve and
must be purchased separately. If faucet inlet hoses will not reach water
supplies, longer hoses must be purchased separately.
For complete detailed installation and operating instructions, see
installations instructions (No. M968808) supplied with Thermostatic
Mixing Valve.
F
REMOVE MIXING HANDLE
FOR FAUCETS PURCHASED AFTER OCTOBER 2019 (FIG. 6)
Note: Before removing the handle, preset the desired water temperature
and while disassembling make sure to keep the SHAFT EXTENSION (8)
in place.
1. Unthread SET SCREW (3) and remove HANDLE (5).
2. Remove LIMIT STOP (1).
3. Using a Slotted screwdriver unthread SCREW (7) and remove
SHAFT EXTENSION (8).
Note: Hold the extension in place while unthreading the screw.
4. Install CAP (9) onto the Body and press until you hear a click.
Note: Sharper side faces towards the back of the body.
MAINTENANCE
A
HAND WASH SENSOR OPERATION; Fig. 1
REMOVE PROTECTIVE FILM FROM SENSOR EYE WHEN
INSTALLATION IS COMPLETE.
When the Sensor detects a user, the water immediately starts to ow.
Water ow will stop 1.5 seconds after user is out of sensor range. This
Comfort delay allows the user to comfortably move their hands without
the water turning off.
As a precaution, a Safety Timer will turn off the water, after the sensor
has been blocked for 59 seconds. The water will stay off until the
blockage is removed from the detection zone.
The Comfort and Safety time settings can be adjusted using the
Optional Remote Control (605XRCT).
7
M965754 Rev. 1.7 (7/18)
B
REPLACE BATTERY; Fig. 5, 6
1. Remove COVER SCREW (1) and lift COVER (15) off.
2. Disconnect SENSOR CABLES (6) and (7) from the
BATTERY and SOLENOID VALVE. (Fig. 6)
3. Push BATTERY (17) forward and Pull it out. (Fig. 5)
4. Replace the new battery with the same placement.
(Insert terminal side rst)
C
CHANGE SENSOR RANGE;
Fig. 5, 6
1. Remove the COVER SCREW (1).
2. Remove the COVER (15).
3. Disconnect the BLACK POWER SUPPLY CONNECTOR
(7) and reconnect. Fig. 6.
4. While the SENSOR CONTROL LED (9) is blinking slowly,
place your hand 1 - 2 in. (25.4-50.8mm) in front of the
sensor.
5. When the LED stops blinking and stays “ON”, move your
hand to the desired position and hold in place until the
LED begins to blink again.
6. Once the SENSOR CONTROL LED (9) begins to blink
again,
remove your hand from the detection zone. When the
ashing stops, the detection distance is set.
7. Reassemble the COVER (15) and secure it with COVER
SCREW (1).
D
ADJUST HOT LIMIT STOP;
Fig. 7, 9
To reduce the amount of hot water that can mix with cold, the
installer can adjust hot limit stop (Four different settings).
1. Rotate LEVER HANDLE (3) counter-clockwise to its stop
position (100% cold).
2. Remove LEVER SCREW (5) and pull off the LEVER
HANDLE (3).
3. Pull out LIMIT STOP (1) from the VALVE STEM (5).
4. Rotate LIMIT STOP (1) between the shaded area and
insert back onto VALVE STEM (5).
5. Each notch on the LIMIT STOP (1) will reduce the amount
of hot water by approximately 3%. For example, the 2nd
notch will have 97% of maximum temp, the 3rd notch will
have 94% and the fourth will be 91%.
6. Replace LEVER HANDLE (3), LEVER HANDLE SCREW
(5) and tighten.
15
16
2
1
4
9
14
7
Fig. 5
Fig. 6
6
12
17
1
2
Fig. 7
8
M965754 Rev. 1.7 (7/18)
E
ADJUST OR REPLACE MAXIMUM
OUTLET TEMPERATURE; Fig. 8
1. With the COVER off, the installer can reduce the maximum mixed
water temperature by turning the THERMO VALVE (4) clockwise
with a screwdriver.
2. Remove SCREW (6) and unthread THERMO VALVE (4).
Replace with new THERMO VALVE (4).
WARNING
Do not turn the THERMO VALVE (4) More than 1 turn.
The maximum mixed water temperature can not be
increased due to ASSE 1070 requirements.
F
GENERAL CLEANING
1. Only use a damp, soft cloth to clean the spout and the sensor.
2. For tougher dirt, use a soft cloth with diluted dish washing
detergent. Wipe the area using a wet cloth and dry using a
soft cloth.
CAUTION
Do not scratch the sensor when cleaning. Avoid using
any abrasives or harsh detergents or chemicals.
Fig. 12
4
1
2
3
6
5
Fig. 8
Fig. 9
9
M965754 Rev. 1.7 (7/18)
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
(844) CRT-TEAM / (844) 278-8326
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
IN MEXICO 01-800-839-1200
Product names listed herein are trademarks of AS America, Inc. © 2018
To learn more about American Standard Selectronic
®
Products visit our website at:
www.americanstandard-us.com or e-mail us at: CRTTEAM@
lixilamericas.com
Mon. - Fri. 8:00 a.m. to 8:00 p.m. EST Saturday 10:00 a.m. to 4:00 p.m. EST
TROUBLESHOOTING FLOW CHARTS
UNIT DOES NOT FUNCTION
1 1
2 2
YES
YES
NO
NO
YES
NO
OPEN EXTERNAL SUPPLY STOPS.
CRITICALLY LOW BATTERY.
INSTALL NEW BATTERY.
DEAD BATTERY. INSTALL
NEW BATTERY. REPEAT.
NO
CHECK FOR DAMAGE TO SENSOR WIRE INSULATION.
REPLACE SENSOR.
ARE EXTERNAL SUPPLY
STOPS OPEN?
REPEATED DOUBLE FLASH
ON SENSOR?
RECONNECT BATTERY TO SENSOR.
DOES SENSOR FLASH FOR 5 SECONDS?
REPLACE SOLENOID
YES
YES
NO
CHECK FOR DAMAGE TO SENSOR WIRE INSULATION.
REPLACE SENSOR.
RECONNECT BATTERY TO SENSOR.
DOES SENSOR FLASH FOR 5 SECONDS?
NO
FULLY OPEN EXTERNAL SUPPLY STOPS BY
TURNING COUNTER CLOCKWISE.
INSPECT FILTER ASSEMBLY, AERATOR AND
SOLENOID VALVE. REMOVE, CLEAN AND INSERT
BACK TO ORIGINAL POSITION.
CHECK FOR BLOCKAGE
ARE EXTERNAL SUPPLY STOPS FULLY
OPEN?
REPLACE SOLENOID
WATER IS CONTINUOUSLY RUNNING
LOW FLOW ISSUES
10
M965754 Rev. 1.7 (7/18)
M903704-0070A
SHAFT
M954480-0070A
SOLENOID VALVE
M910297-0070A
0.35 GPM AERATOR
M964172-0070A
0.5 GPM AERATOR
M964171-0070A
1.5 GPM AERATOR
M962061-0070A
MOUNTING KIT
775P400.XXX
4" ESCUTCHEON
775P800.XXX
8" ESCUTCHEON
M950023-0070A
INLINE FILTER FOR
7755.1XX & 775B.1XX
REQUIRES (1)
M950019-0070A
INLINE FILTER FOR
7755.2XX & 775B.2XX
7755.3XX & 775B.3XX
REQUIRES (2)
M970151-YYY0A
LEVER HANDLE
M907288-YYY0A
PLUG BUTTON
M950384-0070A
SENSOR
(FOR 7755 SKUS)
M924107-0070A
SENSOR
(FOR 775B SKUS)
M950338-0070A
POWER SUPPLY
M950511-0070A
10' EXTENSION
M950511-0070A
10' EXTENSION
M950361-0070A
PWRX BATTERY PACK
M964455-0070A
BRACKET
A923654-0070A
BATTERY 6V CR-P2
M950512-0070A
MULTI-AC ADAPTER
PWRX Power Kit
PK00.WRK
Plug-In AC
Power Kit
PK00.PAC
Hard-Wired AC
Power Kit
PK00.HAC
Multi-AC
Power Kit
PK00.MAC
CR-P2 Lithium Battery
7755. Series
A912746-0070A
SPOUT O-RING
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
(844) CRT-TEAM / (844) 278-8326
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
IN MEXICO 01-800-839-1200
Product names listed herein are trademarks of AS America, Inc. © 2018
To learn more about American Standard Selectronic
®
Products visit our website at:
www.americanstandard-us.com or e-mail us at: CRTTEAM@lixilamericas.com
Mon. - Fri. 8:00 a.m. to 8:00 p.m. EST Saturday 10:00 a.m. to 4:00 p.m. EST
M970210-0070A
SCREW
M970556-0070A
HANDLE ADAPTER
M923155-0070A
HOT LIMIT STOP
M970354-0070A
THERMOSTATIC VALVE
ASSEMBLY
M950399-0070A
SINGLE AC ADAPTER
M950360-0070A
CONNECTOR
LOCKING
DEVICE
M950360-0070A
CONNECTOR
LOCKING DEVICE
M950360-0070A
CONNECTOR
LOCKING DEVICE
M923290-0070A
HOT/COLD
SUPPLY HOSES
M950527-0070A
POWER SUPPLY
MODEL NUMBERS
7755.1xx 775B.1xx
7755.2xx 775B.2xx
7755.3xx 775B.3xx
NextGen Selectronic
®
Integrated Faucet with Optional Above-Deck
Mixing & SmarTherm
®
Temperature Limiter
Appropriate finish code
POLISHED CHROME 002
BRUSHED NICKEL 295
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10

American Standard 775B103.002 Installation guide

Category
Sanitary ware
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI