  • Hello! I am an AI chatbot trained to assist you with the Quadrafire Mt. Vernon AE Pellet Insert Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
R
7014-190B March 22, 2017 Page 1 of 3
1445 North Highway
Colville, WA 99114
www.quadrare.com
NOTE: This vent adapter can be installed with 3 or 4 inch
(76 or 102mm) pellet venting. You can attach the adapter
before or after the installation of the venting into the ue
or chase.
Included in Kit:
C1
X1
Tools Required:
Electric drill, #26 drill bit (included), #2 Phillips screw-
driver, and high temp silicone (500° F).
C3
X1
C2
X3
Attaching the Vent Adapter (C1) to the Venting:
1. Apply high temperature silicone sealant to the outside
of the appropriate size connector at the top of the Vent
Adapter (C1) (Figure 1 & 2).
Figure 1
Figure 2
Do not apply sealant to the inside of the
venting or to the inside of the Vent Adapt-
er, this can slow down the exhaust ow
and make servicing more difcult.
DO NOT
SILICONE
INSIDE VENTING
OR ADAPTER
SILICONE
OUTER EDGE
OF INNER
PIPE
3 INCH (76MM)
CONNECTION
3 INCH (76MM)
CONNECTION
DO NOT
SILICONE
INSIDE VENTING
OR ADAPTER
SILICONE
OUTER EDGE
OF OUTER
PIPE
4 INCH (102MM)
CONNECTION
4 INCH (102MM)
CONNECTION
TOP VENT ADAPTER INSTALLATION INSTRUCTIONS
Vertical centering adapter and clean-out.
Part: TPVNT-4
For Insert Pellet Appliance:
Mount Vernon AE Insert
7014-190B March 22, 2017 Page 2 of 3
Installing the Mt. Vernon Insert using the Vent Adapt-
er (C1):
3. Open the 2 latches that hold the original vent connector
to the blower outlet. Remove and discard the original
vent connector (Figure 5).
Figure 4
DO NOT THROW AWAY THE GASKET!
If the gasket is stuck to the blower leave
in place. If the gasket is stuck to the orig-
inal vent connector, remove it and re-in-
stall it on the blower outlet.
2. Insert venting into Vent Adapter (C1) into the pipe vent-
ing. Using the electric drill and #26 drill bit (C3), drill 3
holes through the venting and the Vent Adapter. Se-
cure the venting to the Vent Adapter with the 3 screws
(C2) (Figure 3 & 4).
Inspect the joint closely and add sealant if
needed. This is the most common area for
a venting leak.
Figure 3
4 INCH (102MM)
CONNECTION
4 INCH (102MM)
CONNECTION
3 INCH (76MM)
CONNECTION
3 INCH (76MM)
CONNECTION
Open 2 latches and
remove original vent
adapter; leaving gasket
Open 2 latches and
remove original vent
adapter; leaving gasket
Figure 5
7014-190B March 22, 2017 Page 3 of 3
4.
Suspend or otherwise support the venting in such a way
that the bottom of the Vent Adapter (C1) is approximately
14-1/2 inches (368mm) from the oor of the cavity and
the clean-out opening is pointing to the right (Figure 6).
5. Slide the insert into place and place the bottom plate
of the Vent Adapter (C1) onto the blower outlet making
sure the gasket is still in place. Secure Vent Adapter in
place with the latches in same manner as the original
vent connector. (Figure 7 & 8).
Figure 7
NOTICE!
The clean-out door of the Vent Adapter must
be closed at all times except when the appli-
ance is being serviced.
14-1/2
(368mm)
Floor of Cavity
Figure 6
Slide Vent Adapter
(C1) onto gasket,
secure with 2 latches
Slide Vent Adapter
(C1) onto gasket,
secure with 2 latches
Figure 8
Vent Adapter
(C1)
Vent Adapter
(C1)
/