Quadra-Fire 7100FP-BK-B User manual

Category
Fireplaces
Type
User manual

This manual is also suitable for

R
www.quadrare.com
7014-179D
December 16, 2011
CLASSIC BAY 1200 PELLET STOVE
O-T L
Tested and
Listed by
Portland
Oregon USA
OMNI-Test Laboratories, Inc.
C
US
Owners Manual
Installation and Operation
CB1200M-MBK
Model:
DO NOT DISCARD THIS MANUAL
NOTICE
• Importantoperatingand
maintenance instruc-
tionsincluded.
• Leavethismanualwith
partyresponsibleforuse
andoperation.
• Read,understandand
follow these instruc-
tionsforsafeinstalla-
tionandoperation.
DO NOT
DISCARD
WARNING
Please read this entire manual
before installation and use of this
pellet fuel-burning room heater.
Failure to follow these instructions
could result in property damage,
bodily injury or even death.
• Donotstoreorusegasolineorotheram-
mablevaporsandliquidsinthevicinityofthis
oranyotherappliance.
• Donotoverre-Ifanyexternalpartstartsto
glow,youareoverring.Reducefeedrate.
Overringwillvoidyourwarranty.
• Complywithallminimumclearancestocom-
bustiblesasspecied.Failuretocomplymay
causehousere.
Checkbuildingcodespriortoinstallation.
• InstallationMUSTcomplywithlocal,regional,stateandnational
codesandregulations.
• Consultlocalbuilding,reofcialsorauthoritieshavingjurisdic-
tionaboutrestrictions,installationinspection,andpermits.
CAUTION
Testedandapprovedforwoodpelletsandshelled
eldcornfuelonly.Burningofanyothertypeoffuel
voidsyourwarranty.
CAUTION
WARNING
Hot glass will cause burns.
• Donottouchglassuntilitiscooled
• NEVERallowchildrentotouchglass
• Keepchildrenaway
• CAREFULLYSUPERVISEchildreninsameroomas
replace.
• Alertchildrenandadultstohazardsofhigh
temperatures.
High temperatures may ignite clothing or other
ammable materials.
• Keepclothing,furniture,draperiesandotherammable
materialsaway.
HOT SURFACES!
Glassandothersurfacesare
hotduringoperationAND
cooldown.
ToobtainaFrenchtranslationofthismanual,please
contactyourdealerorvisitwww.quadrare.com
Pourobtenirunetraductionfrançaisedecemanuel,
s’ilvousplaîtcontactervotrerevendeurouvisitez
www.quadrare.com
NOTE
Page2
7014-179D
December 16, 2011
R
CB 1200 Pellet Stove
and Welcome to the Quadra-Fire Family!
Hearth&HomeTechnologieswelcomesyoutoourtraditionof
excellence! In choosing a Quadra-Fire appliance, you have
ourassurance ofcommitment toquality,durability,andperfor-
mance.
This commitment begins with our research of the market,
including ‘Voice of the Customer’contacts, ensuring we make
productsthatwillsatisfyyourneeds.OurResearchandDevel-
opmentfacilitythen employs the world’smost advanced tech-
nologytoachievetheoptimumoperationofourstoves,inserts
and replaces. And yet we are old-fashioned when it comes to
craftsmanship.Eachunitismeticulouslyfabricatedandsurfaces
arehand-nishedforlastingbeautyandenjoyment. Our pledge
toqualityiscompletedaseachmodelundergoesaqualitycontrol
inspectionfromdesign,tofabrication,toshipping.
We wish you and your family many years of enjoyment in the
warmth and comfort of your hearth appliance. Thank you for
choosingQuadra-Fire.
SAMPLE
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS /
ESPACES LIBRES MINIMUM DES MATÉRIAUX COMBUSTIBLES:
U.S. ENVIRONMENTAL PROTECTION AGENCY
This model is exempt from EPA certification under 40 CFR 60.531 by definition [Wood Heater (A) "Air-to-Fuel Ra
tio"].
7014-079
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L'ÉTIQUETTE
Made in China/Fait Aux Chine
1445 Highway North
Colville, WA 99114
www.quadrafire.com
A Back Wall to stove / Mur Arrière du poêle 2"/51mm
B Side Wall to Cast Top / Mur De Côté du haut 6"/152mm
CORNER INSTALLATION / NSTALLATION DU COIN :
C Side Wall / Mur De Côté
2"/51mm
VERTICAL ADAPTER KIT INSTALLATION:
UN ASSEMBLAGE POUR ADAPTEUR POUR INSTALLATION VERTICALE:
D Back Wall to Flue Pipe / Mur Arrière tuyau rigide
3"/76mm
B Side Wall to Cast Top / Mur De Côté du haut 6"/152mm
CORNER INSTALLATION WITH VERTICAL ADAPTER KIT:
INSTALLATION DU COIN AVEC UN ASSEMBLAGE D'ADAPTEUR VERTICAL:
E Side Wall / Mur De Côté 2"/51mm
ALCOVE INSTALLATION /
INSTALLATION DE L' ALCÔVE:
Max. Alcove Depth: / La profondeur maximum de l'alcôve 36"/914mm
A Back Wall to stove / Mur Arrière du poêle 2"/51mm
B Side Wall to Cast Top / Mur De Côté du haut 6"/152mm
C Unit corner to diagonal wall / 2" (51mm)
F Top of Unit to Combustibles / Du poêle du haut combustibles 12.5"/318mm
Alcove vertical installation / Installation verticale de l'alcôve
D Back Wall to Flue Pipe / Mur Arrière tuyau rigide
3"/76mm
Floor protector must be noncombustible material, extending beneath heater and to the
front/sides/rear as indicated. Measure front distance (I) from the surface of the glass door.
G = 2"/51mm
H* = 2"/51mm
I = 6"/152mm
FLOOR PROTECTION / PROTECTION DU SOL
Note 1:
In residential installations, when using Parts 811-0580, (3" - 3" Top Vent Adapter) and
812-2690 (3" - 6" Top Vent Adapter Collar) 24 gauge 6" single wall flue connector may be used.
Note 1: Dans les installations résidentielles, lorsque les pièces 811-0580, (dessus de l'adapteur de
ventilation 3" - 3") et 812-2690 (collier de l'adapteur de ventilation 3" - 6"), un tuyau connecteur de 6"
pour mur simple de calibre 24 peut être utilisé.
Note 2: In manufactured home installation, when using Part 811-0580, (3" - 3" Top Vent Adapter) and
812-2690 (3' - 6" Top Vent Adapter Collar), use listed double wall flue connector. An Outside Air Kit
(Part 811-0560 rear or 811-0570 floor), must be used with manufactured home installation.
Note 2: Pour l'installation dans les maisons préfabriquées, lorsque les pièces 811-0580 (dessus de
l'adapteur de ventilation 3" - 3") et 812-2690 (collier de l'adapteur de ventilation 3" - 6"), utilisez un
tuyau connecteur enregistré pour mur double. Un assemblage d'air extérieur (pièce 811-0560 arrière
au 811-0570 la plancer), doit être utilisé pour l'installation dans les maisons préfabriquées.
*Non-combustible floor protection must extend beneath the flue pipe when installed with
horizontal venting or under the Top Vent Adapter with vertical installation.
RECOMMENDED IN USA; REQUIRED IN CANADA
Le poêle doit être placé sur une assise non combustible s’étendant tout autour de lui, comme les
schémas l’indiquent. Mesurez la distance du devant (I) de la surface de la porte vitrée.
*Un protecteur incombustible de plancher doit s'étendre sous le conduit de cheminée pour une
installation de ventilation horizontale ou sous un adapteur de ventilation de dessus pour une
installation verticale. ÉTATS-UNIS - RECOMMANDÉ; CANADA - REQUIRENT
D
B
C
C
E
E
A
B
H*
G
G
I
A
B
C
C
F
A
D
2010 2011 2012 JAN FEB MAR APR MAY JUNE JULY AUG SEPT OCT NOV DEC
Listed Solid Fuel Room Heater/Pellet Type Insert. Also suitable for Mobile Home Installation. This appliance has
been tested and listed for use in Manufactured Homes in accordance with OAR 814-23-9000 through 814-23-909.
Tested to: ASTM E1509-95, ULC/ORD-C-1482-M1990, ULC S627-M93 Room Heating Pellet Burning Type,
APFI, (UM) 84-HUD FOR USE
ONLY WITH PELLETIZED WOOD OR SHELLED FIELD CORN FUEL.
Input Rating: 40,000 Btu's/hr
Electrical Rating:
115 VAC, 60 Hz, Start 4.6 Amps, Run 1.6 AMPS.
Route power cord away from unit. Do not route cord under or in front of appliance.
DANGER:
Risk of electrical shock. Disconnect power supply before servicing. Replace glass only with 5mm
ceramic available from your dealer. To start, set thermostat above room temperature, the stove will light
automatically. To shutdown, set thermostat to below room temperature. For further instruction refer to owner's
manual.
Keep viewing and ash removal doors tightly closed during operation.
Testé à: ASTM E1509-95, ULC/ORD-C 1482-M1990, ULC S627-M93 Room Heating. Pellet Burning Type, APFI, (UM)
84-HUD POUR USAGE AVEC LES BOULETTES DE BOIS OU DE COMBUSTIBLE DE MAIS ÉCOSSÉ DES CHAMPS.
Puissance de Rendement: 40,000 Btu's/hr
Puissance Électrique: 115 VAC, 60 Hz, Début 4.6 Amps, Courir 1.6 Amps,
Éloignez le fil électrique de l'appareil. Ne pas faire passer le fil électrique au dessus ou en dessous de l'appareil.
DANGER: Il y a risque de décharge électrique. Déconnectez le fil électrique de la prise de contact avant le service.
Remplacez la vitre seulement avec une vitre céramique de 5 mm disponible chez votre fournisseur.
Pour allumer, monter la température du thermostat au dessus de la température de la pièce, le poêle s'allumera
automatiquement. Pour éteindre, descendre la température du thermostat en dessous de la température de la pièce. Pour des
instructions supplémentaires, référez vous au manuel du propriétaire. Gardez la porte d'ouverture et la porte des cendres
fermées hermétiquement durant l'opération.
Appareil de chauffage inséré de combustible solide/de type de boulettes. Accepté dans l'installation dans les maisons mobiles. Cet
appareil a été testé et enregistré pour l'usage dans les Maisons Mobiles en accord avec OAR 814-23-9000 jusqu'à 814-23-
909.
R
Report / Rapport
061-S-21-4
CB 1200 Pellet Stove
SERIAL NO.
/ NUMÉRO DU
CAUTION:
HOT WHILE IN OPERATION DO NOT TOUCH. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE
SKIN BURNS. SEE NAMEPLATE AND INSTRUCTIONS. Operate this unit with fuel hopper lid closed. Failure to do so may result in emissions
products' combustion from the hopper under certain conditions. Maintain hopper seal in good condition. Do no over fill the hopper.
ATTENTION:
CHAUD LORS DE L'OPÉRATION. NE PAS TOUCHER. GARDEZ LES ENFANTS ET LES VÊTEMENTS LOIN DE L'ESPACE DÉSIGNÉ DE L'INSTALLATION. LE
CONTACT PEUT CAUSER DES BRÛLURES À LA PEAU. VOIR L'ÉTIQUETTE ET LES INSTRUCTIONS. Opérez cet appareil avec le couvercle de la trémie fermé. Le défaut de ne
pas suivre les instructions peut résulter, sous certaines conditions, en une combustion des émissions des produits venant de la trémie. Ne pas remplir la trémie trop pleine.
007C
O-T L
Tested and
Listed by
Portland
Oregon USA
OMNI-Test Laboratories, Inc.
C
US
SAMPLE SERIAL NUMBER / SAFETY LABEL LOCATION:
Behind left side curtain on outside of hopper wall.
Testing Lab &
Report Number
Serial Number
Model
Mfg Date
NOTE: Consult insurance carrier, local building inspector, re ofcials
or authorities having jurisdiction over restrictions, installation inspection
and permits.
R
December 16, 2011
7014-179D
Page3
CB 1200 Pellet Stove
Section 1: Listing and Code Approvals
A. ApplianceCertications......................4
B. MobileHomeApproved......................4
C. GlassSpecications............................4
D. ElectricalRating..................................4
E. BTU&EfciencySpecications..........4
Section 2: Getting Started
A. Design,Installation&Location
Considerations....................................5
B. LocatingYourAppliance&Chinmey. . 6
C. ThermostatLocation...........................6
D. Draft....................................................6
E. NegativePressure..............................6
F. FireSafety..........................................7
G. Tools&SuppliesNeeded...................7
H. InspectAppliance&Components.......7
Section 3: Dimensions & Clearances
A. ApplianceDimensions........................8
B. ClearancestoCombustibles...............9
C. HearthRequirements..........................10
Section 4: Vent Information
A. Chimney&ExhaustConnection.........11
B. VentingTerminationRequirements....11
C. EquivalentFeetofPipe.......................12
D. PipeSelectionChart............................12
Section 5: Venting Systems
A. Alcove.................................................13
B. ThroughtheWall.................................14
C. Vertical................................................15
D. ThroughtheWall&Vertical-Exterior. 15
E. Vertial-Internal...................................16
E. Masonry..............................................16
F. AlternateMasonry...............................16
Section 6: Mobile Home..................................17
Section 7: Appliance Set-Up
A. OutsideAirKit,Rear&Floor..............18
B. TopVentAdapter...............................19
C.
RearVent&ReartoTopVentAdapter
. 19
D. BrickSet.............................................20
E. BrickClip............................................20
F. LogSetPlacement..............................21
G. GrilleAssembly...................................21
H. LogoInstallation..................................21
I. DoorInstallation..................................22
J. ThermostatInstallation........................22
Section 8: Operating Instructions
A. FuelSize&Material............................23
B. GeneralOperationInformation...........23
C. BeforeYourFirstFire.........................24
D. StartingYourFirstFire........................24
E. FireCharacteristics.............................24
F. FeedRateAdjustment.......................24
G. IgnitionCycles....................................25
H. FrequentlyAskedQuestions...............25
Section 9: Troubleshooting............................26-28
Section 10: Maintaining & Servicing Appliance
A. ProperShutdownProcedures.............29
B. QuickReferenceMaintenanceChart. . 29
C. GeneralMaintenance&Cleaning.......29-32
D. HighAshFuelContentMaintenance.. 33
E. BlowerReplacement...........................33-34
F. BafeRemoval....................................34
G. IgniterReplacement............................34
 H. GlassReplacement.............................35

Section 11: Reference Material
A. ComponentFunctions&Locations.....36-37
B. ComponentLocations(Drawings)......38
C. ExplodedDrawings.............................39-40
D. ServiceParts&Accessories...............41-45
E. WarrantyPolicy...................................46-47
F. ContactInformation.............................48
TABLE OF CONTENTS
Safety Alert Key:
• DANGER! Indicatesahazardoussituationwhich,ifnotavoidedwillresultindeathorseriousinjury.
• WARNING!Indicatesahazardoussituationwhich,ifnotavoidedcouldresultindeathorseriousinjury.
• CAUTION! Indicatesahazardoussituationwhich,ifnotavoided,couldresultinminorormoderateinjury.
• NOTICE:Indicatespracticeswhichmaycausedamagetothereplaceortoproperty.
Page4
7014-179D
December 16, 2011
R
CB 1200 Pellet Stove
1
Listing and Code Approvals
A. Appliance Certication
C. Glass Specications
E. BTU & Efciency Specications
Thisapplianceisequippedwith5mmceramicglass.Replace
glass only with 5mm ceramic glass. Please contact your
dealerforreplacementglass.
B. Mobile Home Approved
NOTE: Thisinstallationmustconformwithlocalcodes.
Intheabsenceoflocalcodesyoumustcomplywiththe
ASTM E1509-95, ULC S627-M93, ULC/ORD-C-1482-
M1990, (UM) 84-HUD
D. Electrical Rating
115VAC,60Hz,Start4.1Amps,Run1.1Amps
*BTUoutputwillvary,dependingonthebrandoffuelyou
use in your stove. Consult your Quadra-Fire dealer for
bestresults.
NOTE: Hearth&HomeTechnologies,manufacturerof
thisappliance,reservestherighttoalteritsproducts,
theirspecicationsand/orpricewithoutnotice.
Emissions Rating 0.
.
9grams/hr
*BTU Output 14,000-40,000/hr
Heating Capacity upto2,500sq.ft.depending
onclimatezone
Hopper Capacity 80lbs
Fuel WoodPelletsorShelledCorn
Shipping Weight 349lbs
Model CB1200PelletStove
Laboratory OMNITestLaboratories,Inc.
Report No. 061-S-21-4
Type SolidFuelRoomHeater/PelletFuel
BurningType
Standard ASTME1509-95,ULCS627-M93and
ULC/ORD-C1482-M1990RoomHeater
PelletFuelBurningtypeand(UM)84-
HUD,MobileHomeApproved.
State Listing Colorado,Listed09-13-05
NOTE: Some generator or battery back-up systems
may not be compatable with the micro-processor elec-
tronics on this appliance. Please consult the power
supply manufacturer for compatable systems.
WARNING! Risk of Fire! Hearth & Home Technologies
disclaimsanyresponsibilityfor,andthewarrantyandagency
listingwillbevoidedbytheaboveactions.
DO NOT:
• Installoroperatedamagedappliance
• Modifyappliance
• Install other than as instructed by Hearth & Home
Technologies
• Operate the appliance without fully assembling all
components
• Overre
• Install any component not approved by Hearth &
HomeTechnologies
• InstallpartsorcomponentsnotListedorapproved.
Improper installation, adjustment, alteration, service or
maintenancecancauseinjuryorpropertydamage.
Forassistanceoradditionalinformation,consultaqualied
installer,serviceagencyoryourdealer.
Quadra-FireisaregisteredtrademarkofHearth&Home
Technologies.
This appliance is approved for mobile home installations
whennotinstalledinasleepingroomandwhenanoutside
combustionairinletisused.
Thestructuralintegrityofthemobilehomeoor,ceiling,and
wallsmustbemaintained.
Theappliance mustbeproperlygroundedtotheframeof
themobilehomeanduseonlyListedpelletventClass“L”
or“PL”connectorpipe.
AQuadra-FireOutsideAirKitmustbeinstalledinamobile
homeinstallation.YoumustordertheOutsideAirKitsepa-
rately.
Note: The appliance is also approved for installation
into a shop.
R
December 16, 2011
7014-179D
Page5
CB 1200 Pellet Stove
A
.
Design, Installation & Location Consider-
ations
Warning! Risk of Fire Damagedpartscouldimpairsafe
operation.DoNOTinstalldamaged,incompleteorsubstitute
components.
1. Appliance Location
NOTICE: Checkbuildingcodespriortoinstallation.
• InstallationMUSTcomplywithlocal,regional,stateand
nationalcodesandregulations.
• Consult insurance carrier, local building inspector, re
ofcialsorauthoritieshavingjurisdictionoverrestrictions,
installationinspectionandpermits.
Itis a good idea toplan your installation on paper, using
exact measurements for clearances and oor protection,
beforeactuallybeginningtheinstallation
Considerationmustbegivento:
• Safety,convenience,trafcow
• Placementofthechimneyandchimneyconnector.
• Ifyouarenotusinganexistingchimney,placetheappli-
ancewheretherewillbeaclearpassageforafactory-
builtlistedchimneythroughtheceilingandroof.
• Installinganoptionaloutsideairkitwouldaffecttheloca-
tionoftheventtermination.
CAUTION! Ifburning shelledeldcorn,youmustuseap-
provedventingspecicallydesignedforcorntopreventcorro-
sionordegradation.Followtheinstructionsfromtheventing
manufacturer.
Sincepelletexhaustcan contain ash, soot or sparks,you
mustconsiderthelocationof:
• Windows
• AirIntakes
• AirConditioner
• Overhang,softs,porchroofs,adjacentwalls
• Landscaping,vegetation
Whenlocatingventandventingtermination,ventaboveroof
linewhenpossible.
Marginal Location:
• Below peak
Location NOT recommended:
• Not the highest point of the roof
• Wind loading possible
Multi-level Roofs
Windward
Leeward
Recommended:
Outside Air Intake
on windward side
NOT recommended:
Outside Air Intake
on leeward side
Recommended Location:
• Above peak
Recommended:
• Insulated exterior chase
in cooler climates
Recommended Location:
• Above peak
• Inside heated space
Location NOT recommended:
• Too close to tree
• Below adjacent structure
• Lower roof line
• Avoid outside wall
Marginal Location:
Wind loading possible
NOTICE: Locating the appliance in a location of
considerableairmovementcancauseintermittentsmoke
spillagefromappliance.Donotlocateappliancenear:
• Frequentlyopendoors
• Centralheatoutletsorreturns
Figure 5.1
2
Getting Started
Page6
7014-179D
December 16, 2011
R
CB 1200 Pellet Stove
C. Thermostat Location
The thermostat’s location will have some effect on the
appliance’soperation.Whenthethermostatislocatedclose
totheappliance,itmayrequireaslightlyhighertemperature
setting to keep the rest of the house comfortable. If the
thermostatlocationisinanadjacentroomoronadifferent
oor level, you will notice higher temperatures near the
appliance.
FireHazard.
WARNING
• Donotoperateappliancebeforereading
andunderstandingoperatinginstructions.
• Failuretooperateapplianceproperlymay
causeahousere.
B. Locating Your Appliance & Chimney
D. Draft
Draftisthepressuredifferenceneededtoventappliances
successfully.Whenanapplianceisdraftingsuccessfully,all
combustion byproducts are exiting the home through the
chimney.
Considerationsforsuccessfuldraftinclude:
• Preventingnegativepressure
• Locationofapplianceandchimney
NOTICE: Hearth & Home Technologies assumes no
responsibilityfortheimproperperformanceofthechimney
systemcausedby:
• Inadequatedraftduetoenvironmentalconditions
• Downdrafts
• Tightsealingconstructionofthestructure
• Mechanicalexhaustingdevices
E. Negative Pressure
WARNING! Risk of Asphyxiation! Negativepressurecan
causespillageofcombustionfumesandsoot.
Negativepressureresultsfromtheimbalanceofairavail-
ablefortheappliancetooperateproperly.Itcanbestron-
gestinlowerlevelsofthehouse.
Causesinclude:
• Exhaustfans(kitchen,bath,etc.)
• Rangehoods
• Combustionairrequirementsforfurnaces,waterheaters
andothercombustionappliances
• Clothesdryers
•
Locationofreturn-airventstofurnaceorairconditioning
• ImbalancesoftheHVACairhandlingsystem
• Upperlevelairleakssuchas:
- Recessedlighting
- Attichatch
- Ductleaks
Tominimizetheeffectsofnegativeairpressure:
• Installtheoutsideairkitwiththeintakefacingprevailing
windsduringtheheatingseason
• Ensureadequateoutdoorairforallcombustionappliances
andexhaustequipment
• Ensurefurnaceandairconditioningreturnventsarenot
locatedintheimmediatevicinityoftheappliance
• Avoidinstallingtheapplianceneardoors,walkwaysor
smallisolatedspaces
• Recessedlightingshouldbea“sealedcan”design
• Attichatchesweatherstrippedorsealed
• Atticmountedductworkandairhandlerjointsandseams
tapedorsealed
Location of the appliance and chimney will affect
performance.
• Installthroughthewarmairspaceenclosedbythebuilding
envelope.This helps to producemoredraft,especially
duringlightinganddie-downofthere.
• Penetratethehighestpartoftheroof.Thisminimizesthe
effectsofwindloading.
Locate termination cap away from trees, adjacent
structures,unevenrooflinesandotherobstructions.
• Minimizetheuseofchimneyoffsets.
• Considertheappliancelocationrelativetooorandceiling
andatticjoists.
• Takeintoconsiderationtheterminationrequirementson
Page 11.
CAUTION
• DONOTCONNECTTHISUNITTOACHIMNEYFLUE
SERVICINGANOTHERAPPLIANCE.
• DONOTCONNECTTOANYAIRDISTRIBUTONDUCT
ORSYSTEM.
• Mayallowuegasestoenterthehouse.
R
December 16, 2011
7014-179D
Page7
CB 1200 Pellet Stove
H. Inspect Appliance & Components and
Pre-Burn Check List
ReciprocatingSaw
ChannelLocks
Hammer
PhillipsScrewdriver
TapeMeausre
PlumbLine
Level
FramingMaterial
Hi-tempCaulkingMaterial
Gloves
SafetyGlasses
FramingSquare
ElectricDrill&Bits(1/4”)
1/4”Self-TappingScrews
Mayalsoneed:
VentSupportStraps
VentingPaint
Tools and building supplies normally required
for installation, unless installing into an existing
masonry replace:
G. Tools And Supplies Needed
Inspectapplianceandcomponentsfor
damage.Damagedpartsmayimpairsafe
operation.
WARNING
• DoNOTinstalldamagedcomponents.
• DoNOTinstallincompletecomponents.
• DoNOTinstallsubstitutecomponents.
Reportdamagedpartstodealer.
1. Placetheapplianceinalocationnearthe
nalinstallationareaandfollowtheproce-
duresbelow:
2. Opentheapplianceandremovealltheparts
and articles packed inside the Component
Pack.Inspectallthepartsandglassforship-
pingdamage.Contactyourdealerifanyirregu-
laritiesarenoticed.
3. All safety warnings have been read and fol-
lowed.
4. ThisOwner’sManualhasbeenread.
5. Floorprotectionrequirementshavebeenmet.
6. Ventingisproperlyinstalled.
7. Theproperclearancesfromtheapplianceand
chimney to combustible materials have been
met.
8. Themasonrychimneyisinspectedbyaprofes-
sionalandis clean, or thefactorybuilt metal
chimneyisinstalledaccordingtothemanufac-
turer’sinstructionsandclearances.
9. The chimney meets the required minimum
height.
10.
All labels have been removed from the glass
door.
11. Plated surfaces have been wiped clean, if
applicable.
12. Thermostatorremotehasbeeninstalled.
13. Apoweroutletisavailablenearby.
• Installationanduseofanydamagedappliance.
• Modicationoftheappliance.
• Installation other than as instructed by Hearth & Home
Technologies.
• Installationand/oruseofanycomponentpartnotapproved
byHearth&HomeTechnologies.
Operating appliance without fully assembling all
components.
• Operatingappliancewithoutlegsattached(ifsuppliedwith
unit).
• DoNOTOverre
Or any such action that may cause a re hazard.
WARNING
Hearth&HomeTechnologiesdisclaimsany
responsibilityfor,andthewarrantywillbe
voidedby,thefollowingactions:
FireRisk.
F. Fire Safety
To provide reasonable re safety, the following should be
givenseriousconsideration:
• Installatleastonesmokedetectoroneachoorofyour
home.
• Locatesmokedetectorawayfromtheheatingappliance
andclosetothesleepingareas.
• Followthesmokedetectormanufacturer’splacementand
installationinstructionsandmaintainregularly.
• ConvenientlylocateaClassAreextinguishertocontend
withsmallres.
• Intheeventofahopperre:
• Evacutethehouseimmediately.
• Notifyredepartment.
Page8
7014-179D
December 16, 2011
R
CB 1200 Pellet Stove
3
Dimensions and Clearances
A. Appliance Dimensions
5.0 in
(127mm)
4-5/8 in
(118mm)
12-3/8 in
(314mm)
14-1/4 in
(362mm)
2-1/2 in
(64mm)
C
L
8-1/6 in.
(205mm)
20- 7/16 in.
(519mm)
28-1/2 in. (724mm)
27-5/8 in.
(692mm)
25-3/4 in.
(654mm)
C
L
10-3/4 in.
(273mm)
24-3/4 in.
(629mm)
25-3/4 in.
(629mm)
8-1/16 in.
(205mm)
C
L
28-1/2 in.
(724mm)
26-1/2 in.
(673mm)
31-5/8 in.
(803mm)
Figure 8.4 - Front View
Figure 8.1 - Top View
Figure 8.3 - Side View
Figure 8.2 - Top View with Top Vent Adapter
R
December 16, 2011
7014-179D
Page9
CB 1200 Pellet Stove
Straight Back Against
Wall
Inches Millimeters
A
BackWalltoAppliance 2 51
B
SideWalltoAppliance 6 152
Corner Installation
Inches Millimeters
C
WallstoAppliance 2 51
Vertical Installation
Inches Millimeters
D
BackWalltoFluePipe 3 76
E
SideWalltoTop 6 152
F
BackWalltoAppliance 7.5 191
Installations with:
3 to 3 inch Top Vent Adapter and
3 to 6 inch Offset Adapter Kit
Corner Installation
Inches Millimeters
G
WallstoAppliance 2 51
B. Clearances to Combustibles (UL and ULC)
D
E
F
A
B
FireRisk.
Complywithallminimumclearancesto
combustiblesasspecied.
WARNING
Failuretocomplymaycausehousere.
NOTE:
IllustrationsreecttypicalinstallationsandareFOR
DESIGNPURPOSESONLY.
Illustrations/diagramsarenotdrawntoscale.
Actualinstallationmayvaryduetoindividualdesign
preference.
C
C
G
G
Alcove Installation
Inches Millimeters
MinimumAlcoveHeight 44 1117
MinimumAlcoveWidth 40-1/2 1029
MaximumAlcoveDepth 36 915
MinimumAlcoveSideWall 6 152
TopofUnittoCombustibles 12-1/2 318
Page10
7014-179D
December 16, 2011
R
CB 1200 Pellet Stove
*L Exception for Horizontal Installations:
USA INSTALLATIONS:A
non-combustibleoorprotec-
tion is recommended extending beneath the ue pipe
when installed with horizontal venting or under the top
ventadapterwithverticalinstallation.
CANADA INSTALLATIONS:A
non-combustible oor
protection extending beneath the ue pipe is required
withhorizontalventingorunderthetopventadapterwith
verticalinstallation.
Must extend 2 inches (51mm) beyond each
side of pipe (shaded area)
C. Hearth Pad Requirements (UL and ULC)
L*
K
K
M
Useanon-combustibleoorprotector,extendingbeneath
appliance and to the front, sides and rear as indicated.
Measurefrontdistance“M”fromthesurfaceoftheglass
door.
Hearth Pad Requirements
Inches Millimeters
K
Sides 2 51
L*
Back 2 51
M
Front 6 152
Figure 10.1
Figure 10.2
R
December 16, 2011
7014-179D
Page11
CB 1200 Pellet Stove
Do not terminate ventinanyenclosedorsemi-enclosed
areasuchasacarport,garage,attic,crawlspace,undera
sundeckorporch,narrowwalkwayorcloselyfencedarea,
oranylocationthatcanbuildupaconcentrationoffumes
suchasastairwell,coveredbreezeway,etc.
CAUTION
A. Chimney and Exhaust Connection
1. Chimney & Connector: Use 3or4 inch (76-102mm)
diametertype"L"or"PL"ventingsystem.Itcanbevented
verticallyorhorizontally.
2. Mobile Home: ApprovedforallListedpelletvent.Ifusing
the3inch(76mm)verticaltopventadapterkitorthe3
to6inch(76-152mm)topventoffsetadapter,useListed
doublewallueconnector.AQuadra-Fireoutsideairkit
mustbeusedwithmanufacturedhomeinstallations.
3. Residential: The3inch(76mm)verticaltopventadapter
kitandthe3to6inch(76-152mm)topventoffsetadapter
aretestedtouse24gaugesinglewallueconnectoror
ListeddoublewallueconnectortoClassAListedmetal
chimneys,ormasonrychimneysmeetingnationaland/or
localcodesforsolidfuelappliances.
4. INSTALL VENT AT CLEARANCES SPECIFIED BY THE
VENT MANUFACTURER.
5. Secureexhaustventingsystemtotheappliancewithatleast
3screws.Alsosecureallconnectorpipejointswithatleast
3screwsthrougheachjoint.
6. DO NOT INSTALLA FLUE DAMPER IN THE EXHAUST
VENTINGSYSTEMOFTHISUNIT.
7. DO NOT CONNECTTHIS UNIT TOA CHIMNEY FLUE
SERVINGANOTHERAPPLIANCE.
NOTE: All pipe must be welded seam pipe whenever pos-
sible. Seal pipe joints with high temperature silicone (500°F
[260°C] minimum rated only). Do not put silicone inside
of pipe.
NOTE: If burning shelled eld corn, you must use approved
venting specically designed for corn. Follow the instruc-
tions from the venting manufacturer.
FireHazard.
• Only LISTED venting components may be
used.
• NOOTHERventcomponentsmaybeused.
Substituteordamagedventcomponentsmay
impairsafeoperation.
WARNING
B. Venting Termination Requirements
1. Terminationmustexhaustaboveairinletelevation.Itis
recommendedthatatleast60inches(1524mm)ofverti-
calpipebeinstalledwhenapplianceisventeddirectly
throughawall.Thiswillcreateanaturaldraft,which
willhelppreventthepossibilityofsmokeorodorventing
intothehomeduringapoweroutage.Itwillalsokeep
exhaustfromcausinganuisanceorhazardbyexposing
peopleorshrubstohightemperatures.Thesafestand
preferredventingmethodistoextendtheventvertically
throughtheroof.
2. Distancefrom doorsandopeningwindows,orgravityor
ventilationairinletsintobuilding:
a. Notlessthan48inches(1.2m)below;
b. Notlessthan48inches(1.2m)horizontallyfrom;
c. Notlessthan12inches(305mm)above.
3. Distancefrompermanentlyclosedwindows:
a. Notlessthan12inches(305mm)below,horizontally
fromorabove.
4. Distance between bottom of termination and grade
shouldbe12inches(305mm)minimum.Thisiscon-
ditional upon plants in the area, and nature of grade
surface.Thegradesurfacemustbeanon-combustible
material(i.e.,rock,dirt).Thegradesurfacemustnotbe
lawn.Distancebetweenbottomofterminationandpublic
walkwayshouldbe84inches(2134mm)minimum.
5. Distance to combustible materials must be 24 inches
(610mm)minimum. Thisincludesadjacentbuildings,
fences,protrudingpartsofthestructure,roofoverhang,
plantsandshrubs,etc.
6. TerminationCapLocation(HomeElectricalService)
• Side-to-sideclearanceistobethesameasminimum
clearancetovinylinsidecorners.
•
Clearanceofaterminationcapbelowelectricalservice
shallbethesameasminimumclearancetovinylsofts.
• Clearanceofaterminationcapaboveelectricalservice
willbe12inches(305mm)minimum.
• Locationoftheventterminationmustnotobstructor
interferewithaccesstotheelectricalservice.
4
Vent Information
VentsurfacesgetHOT,cancauseburnsif
touched.Noncombustibleshieldingorguards
mayberequired.
WARNING
Page12
7014-179D
December 16, 2011
R
CB 1200 Pellet Stove
Improperinstallation,adjustment,alteration,serviceor
maintenancecancauseinjuryorpropertydamage.Refer
totheowner’sinformationmanualprovidedwiththisappli-
ance.Forassistanceoradditionalinformationconsulta
qualiedinstaller,serviceagencyoryourdealer.
WARNING
The chart will help you in determining proper
ventingsizeaccordingtotheequivalentfeetof
pipecalculatedaboveandthealtitudeabovesea
levelofthisinstallation.Figure 12.2.
Locatethecalculatedequivalentfeetofpipeon
theverticalleftsideof thechart. Movetothe
right horizontally on the chart until you reach
youraltitudeabovesealevel.
Ifyoufallbelowthediagonalline,3or4inch(76
to102mm)pipemaybeused.Ifitisanywhere
abovethediagonalline,a4inch(102mm)diam-
eterpipeisrequired.
Thechartrevealsthata90°elbowis5timesas
restrictive to the ow of exhaust gases under
positivepressureas1footofhorizontalpipe,and
afootofhorizontalpipeistwiceasrestrictiveas
afootofverticalpipe.
D. Pipe Selection Chart
Thetablebelowcanhelpyoucalculatetheequivalentfeet
ofpipewhichisamethodusedtodeterminepelletventsize.
Figure 12.1.
C. Equivalent Feet of Pipe
Example of 3 Elbow-Rear Vent Termination Calculaton
Figure 12.1
FireRisk.
DoNOTpackinsulationorother
combustiblesbetweenrestops.
• ALWAYS maintain specied clearances
aroundventingandrestopsystems.
• Installrestopsasspecied.
Failuretokeepinsulationorothermaterial
awayfromventpipemaycausere.
WARNING
3 in. or 4 in. (76mm or 102mm) Diameter Pipe
Equivalent Pipe
Length In Feet
ALTITUDE IN THOUSANDS OF FEET
0
20
30
1 2 3 4 5 6 7 8 9 10
4 in. (102mm) Diameter Pipe Only
10
Example 1
Example 2
Figure 12.2
3 ft
(914mm)
2 ft (609mm)
2 ft (609mm)
2 ft (609mm)
Pellet Venting
Component
# of
Elbows
Feet of
Pipe
Multipled
By
Equivalent
Feet
Components
Equivalent Feet
90
o
ElboworTee
3 X 5 15
45
o
Elbow
X 3
HorizontalPipe
7 X 1 7
VerticalPipe
2 X 0.5 1
TotalEquivalentFeet 23
Note:Thisisagenericexampleandisnot
intendedtorepresentanyspecicfueltype.
Example 1:Iftheequivalentlengthofpipeis23feet
(7m)withaltitudeof8,000feet(2438m)youmustuse
4inch(102mm)diametertype“L”or“PL”vent.
Example 2:Iftheequivalentlengthofpipeis12feet
(3.7m)withaltitudeof6,000feet(1829m) you may
use3or4inch(76to102mm)diametertype“L”or
“PL”vent
R
December 16, 2011
7014-179D
Page13
CB 1200 Pellet Stove
5
Venting Systems
NOTE:
IllustrationsreecttypicalinstallationsandareFOR
DESIGNPURPOSESONLY.
Illustrations/diagramsarenotdrawntoscale.
Actualinstallationmayvaryduetoindividualdesign
preference.
A. Alcove
Figure 13.1
Allminimumslistedaretoacombustiblesurface.
A
C
B
D
Alcove Installation
Inches Millimeters
A
MinimumAlcoveHeight 44 1117
B
MinimumAlcoveWidth 40-1/2 1029
C
MaximumAlcoveDepth 36 915
D
MinimumAlcoveSideWall 6 152
notshown TopofUnittoCombustibles 12-1/2 318
Page14
7014-179D
December 16, 2011
R
CB 1200 Pellet Stove
6 in.
(152mm)
Minimum
Non-combustible Hearth Pad
W all
Thimble
Horizontal
T ermination
Cap
2 in.
(51mm)
Minimum
6 in.
(152mm)
Minimum
From Glass
Straight Out
B. Through The Wall
Horizontalterminationcapmustbeaminimumof12inches.
(305mm)fromthewall.Approvedformobilehomeinstal-
lations.Mustuse3or4inch(76-102mm)“L”or“PL”listed
pelletventingorlisteddoublewallpipeandaQuadra-Fire
outsideairkitinmobilehomes.
NOTE:
InCanada, where passage through awallor partition of
combustible construction is desired, the installation shall
conformtoCAN/CSA-B365
Figure 14.1
Figure 14.2
Wall
Thimble
Illustration shows venting going in both directions.
Choose which one is best for your installation.
2 in. (51mm)
Minimum
2 in. (51mm)
6 in.
(152mm)
Minimum
6 in. (152mm)
Minimum
45 Degree
NOTICE:
Please note that while the minimum
clearancefortheterminationcapis6
inches(152mm)thereisthepossibly
of soot buildup around the termina-
tion area. If this occurs we suggest
tomovetheterminationfurtheraway
fromthehousetopreventit.
R
December 16, 2011
7014-179D
Page15
CB 1200 Pellet Stove
Werecommend a minimumof60in. (1.5m) vertical,
howeverabovetheeaveispreferred.
Bothinstallationsareapprovedformobilehomeinstal-
lations. Must use 3 or 4 inch (76 to 102mm) “L” or
“PL”Listedpelletventingorlisteddoublewallpipeand
Quadra-Fireoutsideairkitinmobilehomes.Single
wallpipeisapprovedforresidentialinstallationsonly.
C. Vertical into Existing Class A Chimney
D. Through The Wall & Vertical - External
Firestop
Flashing
Rain Cap
6 in.
(152mm)
Min.
Non-combustible Hearth Pad
3 in. (76mm)
Min.
Clean-out
Cover
24 in. (610mm)
minimum
Ceiling Support
Class A Chimney
Connector Adapter
Top Vent Kit
Non-combustible Hearth Pad
Clean-out Cover
Tee
Wall Thimble
Support Bracket
every 60 in. (1524mm)
24 in. (610mm)
Minimum
Rain Cap
Flashing
2 in. (51mm) Minimum
6 in. (152mm)
Minimum
Figure 15.1
Figure 15.2
E. Vertical - Internal - Typical Installation
Firestop
Flashing
Rain Cap
6 in.
(152mm)
Min.
Non-combustible Hearth Pad
3 in. (76mm) Min.
24 in.
(610mm)
Minimum
3 in. to 3 in.
(76-76mm)
Top Vent Kit
Clean-out Cover
Figure 15.3
Page16
7014-179D
December 16, 2011
R
CB 1200 Pellet Stove
FireHazard
InspectionofChimney:
• Masonrychimneymustbeingoodcondition.
• MeetsminimumstandardofNFPA211
• Factory-builtchimneymustbeminimum6in.(152mm)
UL103HT.
WARNING
E. Masonry
F. Alternate Masonry
Non-Combustible Hearth Pad
Airtight
Clean-out Door
Cleanout Cover
Sheathing
3 in. (76mm) Minimum
1 in. (25mm) Clearance
Flashing
Fireclay Flue
Liner with Airspace
Concrete Cap
1 in. (25mm) Clearance
with Firestop
6 in. (152mm)
Minimum
Non-Combustible Hearth Pad
Sheathing
2 in. (51mm) Minimum
1 in. (25mm)
Clearance
Flashing
Fireclay Flue Liner
with Airspace
Concrete Cap
6 in. (152mm)
Minimum
Airtight Clean-out Door
1 in. (25mm) Clearance
with Firestop
Figure 16.1
Figure 16.2
R
December 16, 2011
7014-179D
Page17
CB 1200 Pellet Stove
6
Mobile Home
1. Anoutsideairinletmustbeprovidedforthecombustion
airandmustremainclearofleaves,debris,iceand/or
snow.Itmustbeunrestrictedwhiletheapplianceis
in use to prevent room air starvation which causes
smokespillage.Smokespillagecanalsosetoffsmoke
alarms.
2. The combustion air duct system must be made of
metal.Itmustpermitzeroclearancetocombustible
constructionandpreventmaterialfromdroppinginto
the inlet or into the area beneath the dwelling and
containarodentscreen.
3. Theappliancemustbesecuredtothemobilehome
structurebyboltingittotheoor(usinglagbolts)intwo
places.Usethesameholesthatsecuredtheappliance
totheshippingpallet.
4. Theappliancemustbegroundedwith#8solidcopper
groundingwireorequivalent,terminatedateachend
withanNECapprovedgroundingdevice.
5. Referto Clearances to Combustibles and oor pro-
tectionrequirementsonpages 9& 10forlistingsto
combustiblesandappropriatechimneysystems.
6. Use silicone to create an effective vapor barrier at
thelocationwherethechimney or other component
penetratestothetheexteriorofthestructure.
7. Followthechimneymanufacturer’sinstructionswhen
installingtheventsystemforuseinamobilehome.
8. InstallationshallbeinaccordancewiththeManufactur-
ersHome&SafetyStandard(HUD)CFR3280,Part
24.
CAUTION
THE STRUCTURAL INTEGRITY OF THE MANUFAC-
TURED HOME FLOOR, WALL AND CEILING/ROOF MUST
BE MAINTAINED.
DoNOTcutthrough:
• Floorjoist,wall,studsorceilingtrusses.
• Anysupportingmaterialthatwouldaffectthestructural
integrity.
NEVER INSTALL IN A SLEEPING ROOM.
WARNING
InstallationmustcomplywithManufacturedHomeand
SafetyStandard(HUD),CFR3280,Part24.
WARNING
You must use a Quadra-Fire Outside Air Kit
for installation in a mobile home.
A. Mobile Home Installation
Figure 17.1
CAUTION
Neverdrawoutsidecombustionairfrom:
• Wall,oororceilingcavity
• Enclosedspacesuchasanatticorgarage
Spark Arrestor Cap
Roof Flashing
Storm Collar
Joist Shield/Firestop
Approved Class “L” or
“PL” Pellet Vent
Page18
7014-179D
December 16, 2011
R
CB 1200 Pellet Stove
7
Appliance Set-Up
A. Outside Air Kit Instructions
Flex Hose
Hose Clamp
Collar Assembly
Trim Ring
Termination
Cap Assembly
Hose Clamp
Included in Kit:1pieceof2inchx3footexhose,2hose
clamps,1collarassembly,terminationcapassembly,1
trimring,12screws.
a. Measuredistancefromoortoairventopeninginappli-
anceandmarklocationonwall.
Usesawto cut opening inwall.Cuta 2-1/2 to 3inch
(64-76mm)openingoninsidewallanda3to3-1/2inch
(76-89mm)openingonoutsideofhouse.
b. Usehoseclamptosecureexpipetocollarassembly.
c. Slidetrimringoverexpipeandrunpipethroughwall.
d. Attach hose to outside termination cap with second
hoseclamp.
e. Secureterminationcaptooutsidesurface.
f. Securetrimringtointeriorwall.
g. Snipcornersandremoveplate.Figure 18.1.
h. Alignandsecurecollarassemblywith2ofthe4holes
asshown.Figure 18.2.
Tools Needed:Phillipsheadscrewdriver;wirecutters;
holesaworjigsaw.
CAUTION
Neverdrawoutsidecombustionairfrom:
• Wall,oororceilingcavity
• Enclosedspacesuchasanatticorgarage
Figure 18.1
1. Rear Installation
Snip Corners
and remove
plate
Figure 18.2
Figure 18.3
a. Removerearscreenandsetaside.
b. Installcoverplateoverholeinrightrearoor.
c. Cuta2inchminimumholeintheoortoaccommodate
exhose.
d. Attachhosetoterminationcap.
e. Placeropeunderpedestaltocloseoffairleaks.
Screen
Install Cover Plate
Seal Pedestal with 26 in. Rope
Figure 18.4
2. Floor Installation
NO
NO
Secure Collar
R
December 16, 2011
7014-179D
Page19
CB 1200 Pellet Stove
3 to 3 inch Top Vent Adapter
3 to 6 inch Top Vent Offset Adapter
1. Putalayerofhightemperaturesiliconeonthe3inch
(76mm)exhaustoutlet.
2. Slidethetopventadapterontotherearexhaustoutlet
andadjusttheassemblytoaverticalposition.
3. Drill4holeswith#26drillbit(provided)intothebackof
theapplianceusingtheoutershieldasapattern(make
suretheassemblyisvertical).Figure 19.1
4. Installthe4mountingscrews.
5. Installtheventpipeintothetopventadapter(besure
tosiliconealljoints).
6 Tocleanthetopventadapter,opentheclean-outcover.
See Figure 19.1
B. Top Vent Adapter Installation
Installing the Top Vent Adapter
3" - 6"
Offset
Adapter
3" - 3"
Top Vent
Adapter
Drill holes in back of
stove and secure with 4
screws, 2 on each side.
Clean Out
Cover
Figure 19.1
C. Rear Vent and Rear Vent to Top Vent
Adapter Installation
Clean-Out Cover
Clean-Out Cover
Figure 19.2 - Rear Vent Adapter
Figure 19.3 - Rear to Top Vent Adapter - 90
o
1. Putalayerofhightemperaturesiliconeonthe3inch
(76mm)exhaustoutlet.
2. Slidetheadapterontotherearexhaustoutletandadjust
theassemblytotheappropriateposition.
3. Installtheventpipeintotheadapter(besuretosilicone
alljoints)
Page20
7014-179D
December 16, 2011
R
CB 1200 Pellet Stove
D. Optional Brick Set Installation
1. Removethebaferst,followinstructionsonpage 34.
2. Slide bottom of left rear brick in rst; rotate top edge
toward rear of appliance and then rotate outer edge
toward rear of appliance, until brick slides into place.
Figure 20.1.
3. Repeatwithrightrearbrick.
4. Placeleftsidebrickalongleftsideofrebox,makingsure
chamfered(beveled)backedgeofbricktssnuglynext
torearbrick.Figure 20.2.
5. Repeatwithrightsidepanel.
6. Completebrickset,correctlyinstalled.Figure 20.3.
1
2
3
1
2
3
4
Figure 20.1
Figure 20.2
Figure 20.3
1. Afterthebricksethasbeeninstalled,2brickclipsneed
tobeinstalledontheouteredgeofeachbafetohold
thebricksetinplace.
2. Remove2bafesfromtheappliance.Slidethebafeup
andthebottomedgeshouldfalldownandthenliftthe
bafeout.
3. Usingpliers,bendthebrickclipslightlypast90°inthe
directionshowninFigure 20.4.
4. PositionthebrickclipasshowninFigure 20.4anduse
plierstocrimparoundtheoutsideedgeofthebafeas
showninFigure 20.5.
Note: Figure 20.5 shows the nished shape of the brick
clip, after being bent around the outside edge of
the bafe.
5. Slidethebafebackintoplacemakingsurethatthebrick
clipholdsthesidebricktowardthewalloftherebox.
Pushbackonthesidessotheywillkeeptherearbricks
inplace.Repeatforoppositeside.
Approximately
1 inch from corner
Top outside
corner of Baffle
Outside edge
of Baffle
Use pliers to crimp
Brick Clip around edge
Installed Clip
E. Brick Clip Installation
• Brickmayhavesmallwiresprotrudingfrom
thebackofbrick.
WARNING
RiskofInjury.
Figure 20.4
Figure 20.5
1
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48

Quadra-Fire 7100FP-BK-B User manual

Category
Fireplaces
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI