  • Hello! I am an AI chatbot trained to assist you with the SignaMax SF-Series Pre-Polished Fiber Optic Connectors Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Field-Installable Pre-Polished Optical Fiber Connectors
www.signamax.com
999 N.W. 159
th
Drive
Miami, FL 33169
800.446.2377
305.944.7710
Fax: 305.949.4483
Copyright 2007 Signamax/AESP, Inc. All rights reserved
Signamax Connectivity Systems is a trademark of AESP, Inc.
Specifications subject to change
Connectivity Solutions
INSTALLATION INSTRUCTIONS
FPC
-
02 Rev.A JAN
-
2016
1
The following installation instructions are intended to be
used when installing the following Signamax optical
Connectors:
FPCxx-SCxx-02
FPCxx-LCxx-02
NOTES:
1. Optical fiber connectors shown in these instructions used for
example purpose only; actual product maybe slightly different in
dimensions and design detail.
2. Picture of tool used for example purpose only; actual tools may
differ from those shown.
3. All illustrations are not to scale
Make sure you have all necessary
tools for the job:
• Cable jacket stripping tool
• Optical fiber stripping tool
• Optical fiber cleaving tool
• Lint-free cloth wipes
• Optical fiber cleaning fluid
• Metric ruler and marker pen
WARNING:
• Wear safety glasses before handling
optical fiber to protect the eyes.
• Never look into the end of a connector or
an optical fiber which may have a laser
coupled to it.
Identify components of the connectors kits:
1: Fiber Connector 2: 900-µm Boot 3: 250-µm Tube
!
3
1
2
Be sure there is no space between
the wedge and connector, if there is,
push the wedge and connector
together to realign.
3
Place the 900-µm boot on the fiber cable, if applicable
then slide 250-µm tube on the fiber. Angle cut first.
Strip 35 mm of 900- and 250-µm
coating off.
2
4
Clean the fiber with a lint-free wipe and
fiber preparation fluid.
5
Strip 35 mm of 250-µm coating off.
Field-Installable Pre-Polished Optical Fiber Connectors
www.signamax.com
999 N.W. 159
th
Drive
Miami, FL 33169
800.446.2377
305.944.7710
Fax: 305.949.4483
Copyright 2007 Signamax/AESP, Inc. All rights reserved
Signamax Connectivity Systems is a trademark of AESP, Inc.
Specifications subject to change
Connectivity Solutions
INSTALLATION INSTRUCTIONS
FPC
-
02 Rev.A JAN
-
2016
Insert the fiber into the connector.
Create a slight bend in the connector
to maintain connection.
2
2
Push the sides tabs to release
and remove the wedge.
2
Slide the boot onto the connector
body.
1
1
Unlock the lever by push out,
being careful not to press the side
tabs
Verify good termination by using a visible
light source.
Good Connection: Bad Connection:
No Light Visible Light
7
By re-inserting the wedge into
the connector, fiber connector
could be re-terminated.
!
8
9
10
Termination of the fiber connector is
complete.
11
12
Set the fiber on the Cleaver and cleave
the fiber to 10.5 mm.
6
/