HOW TO OPERATE THE COOKTOP
USING THE GAS BURNERS
The following symbols are given near each knob on the front panel:
The minimum position is when the knob is turned fully anticlockwise. All the operating positions must be chosen
between the min. and max. positions, and never between max. and off.
AUTOMATIC ELECTRIC IGNITION
To light one of the burners, press the knob corresponding to the burner and turn it anticlockwise to Max. Keep the
knob pressed for automatic lighting of the burner. In case of a power failure or no current, the burner can also be lit
with a match.
APPLIANCES WITH SAFETY VALVE
To light the burners, carry out the same operations given above. In this case, however, once the knobs are turned to
the opening position they must be kept pressed for about 10 seconds.
If for any reason the burner flame goes out, the safety valve automatically cuts in, shutting off the gas to the relevant
burner.
INJECTOR TABLE CATEGORY II2H3B/P
ELECTRICAL POWER SUPPLY: 230 V
~ 50 Hz
Tu r n s p i t
For utilizzation of the turnspit follow the instructions
described.
Put the food in spit L (see fig. 4), paying attention to block
it within the two forks F and to balance it, in order to
avoid any unnecessary effort in motor R.
Put the spit on support G, after having put its opposite
end into hole P of motor R.
Place the drip-tray with a little water under the spit.
To remote the spit, operate in the opposite direction using
protecting glove in isolating wool.
The turnspit can be operated turning the knob clockwise
on position .
Disk full Tap closed
Large flame Max. opening
Small flame Min. opening
Type of gas used Type of
burner
Injector
marking
Rated heat
capacity
kW
Rated
consumption
Reduced heat
capacity kW
Gas pressure mbar
min. rated max.
NATURAL GAS
(Methane) G20
triple ring
rapid
semirapid
auxiliary
oven
grill
130
115
97
72
150
145
3.60
3.00
1.75
1.00
4.30
3.80
343 l/h
286 l/h
167 l/h
95 l/h
410 l/h
363 l/h
1.30
0.75
0.48
0.33
1.40
-
17 20 25
G.P.L
BUTANE GAS G30
PROPANE GAS G31
(cylinder)
triple ring
rapid
semirapid
auxiliary
oven
grill
96
85
65
50
1.00
0.95
3.60
3.00
1.75
1.00
4.30
3.80
262 g/h
219 g/h
128 g/h
73 g/h
313 g/h
277 g/h
1.30
0.75
0.48
0.33
1.40
-
25 28-30 37
Type of gas used Appliance model Total rated heat
capacity kW
Total rated
consumption
Air required for
burning m
3
/h
G20 20 mbar 1 TC - 1R - 2SR - 1 AUX + oven 19.20 1831 l/h 21.6
G30/31 28-30 mbar 1 TC - 1R - 2SR - 1 AUX + oven 19.20 1400 g/h 21.6
1
2
3
4
5
Number of shelves
fig. 4