ALGE-Timing 929 User guide

Type
User guide
ALGE-TIMING GmbH
2012-02-07 Page 1
Adapter 929
2 times adjustible monostabile Inverting Device
Connection to impulse device Adapter 928 Plug to timing device
How does it work:
With a rising or falling impulse you can start or stop an ALGE-timing device
Delay Time and Dip-Switch Adjustment:
The factory setup of the delay time is about 750 ms.
By rotating with a small screw driver it is possible to adjust the delay time between 18 ms and 1.5 s
1on off rising impulse (when opening the contact)
2on off falling impulse (when closing the contact)
3on off start impulse
4on off stop impulse
Delay time of falling impulse
Delay time of rising impulse
1 2 3 4
Tmin = 18 msec
Tmax = 1,5 sec
ON OFF
ALGE-TIMING GmbH
2012-02-07 Page 2
Function: e.g. with a contact mat
Technical Data:
Power Supply: from timing device
Output: NPN Transistor, Open Collector, active low
Impulse Length: 18 to 1500 ms adjustable
Measurements: 65 x 50 x 45 mm
Weight: 0.2 kg
Pin Assignment - Output:
1 impulse output (Start )
2 impulse output (Stop ) 5 1
3 0 Volt ( GND ) 6
4 empty 4 2
5 + 5V stabilized (supply) 3
6 empty
Pin Assignment - Input:
Banana Socket Green: Signal
Banana Socket Black: Masse
Dip Switch Action Reaction
1234Contact Output (timing device)
on off on off closing no reaction
opening timer stops
off on on off closing timer stops
opening no reaction
on on on off closing timer stops
opening timer stops
on off off on closing no reaction
opening timer starts
off on off on closing timer starts
opening no reaction
on on off on closing timer starts
opening timer starts
  • Page 1 1