Maintenance and Troubleshooting:
Calibration with a PC
Calibrate the scanner wh
en colors appear in areas that should be white, or colors of the scanned
image and the original vary, or degraded image quality. Calibration allows you to compensate for
normal variations that can occur in the optical components over time.
Note: If you lose the calibration sheet or the calibration sheet is damaged, contact Ambir support.
1. Use the included calibration sheet to calibrate th
e scanner. The calibration sheet is marked with
arrows on the long edges and is specifically designed for calibrating your scanner.
2. Insert the special calibration sheet into the ADF, with the one of the arrows pointing into the ADF.
3. Click Start > All Programs > Ambir ImageScan Pro
scanner > Calibration Wizard.
4. Click Next from the Calibration Wizard that pops up, then click
Calibrate Now.
5. Click Start to begin the calibration process.
click OK and then click Finish.
Cleaning the ADF
Use th
e following cleaning materials to clean the scanner:
• Non-abrasive cleaning fluid: Isopropyl rubbing alcohol (95%)
Important: Do not use water to clean the ADF.
1. Open the ADF cover by pulling the cover lever.
2. Gently wipe the following areas with the cloth
dampened with cleaner. Be careful
NOT to scratch their surfaces.
Cleaning the Feed Roller:
Wipe the Feed Roller from side to side and then rotate it.
Repeat until then entire roller is cleaned.
Cleaning the Pad Module:
Wipe the Pad Module from top to bottom (in the direction of
arrow shown in below picture). Be careful not to damage the
pick springs of the pad.
Wait for cleaned areas to dry completely.
8