REED DM-01 User manual

Type
User manual

REED DM-01 is a measuring tool with many uses for both professionals and DIY enthusiasts. It has functions to help you measure lengths, areas, and volumes. It uses ultrasonic technology for accurate range finding and can take continuous measurements if you hold the button. It is also equipped with helpful measurement modes such as the start point selection and the sum of lengths. REED DM-01 is compact and lightweight and is powered by a single 9V alkaline battery that will last long thanks to the automatic shut-off feature.

REED DM-01 is a measuring tool with many uses for both professionals and DIY enthusiasts. It has functions to help you measure lengths, areas, and volumes. It uses ultrasonic technology for accurate range finding and can take continuous measurements if you hold the button. It is also equipped with helpful measurement modes such as the start point selection and the sum of lengths. REED DM-01 is compact and lightweight and is powered by a single 9V alkaline battery that will last long thanks to the automatic shut-off feature.

reedinstruments
www
com
Model
DM-01
Ultrasonic
Distance Meter
Instruction
Manual
reedinstruments
www
com
2
Table of Contents
Safety .........................................................................................2-3
Features ......................................................................................... 3
Specications ................................................................................ 3
Instrument Description .................................................................. 4
Operating Instructions ................................................................... 5
Additional Functions ...................................................................6-7
Battery Replacement ..................................................................... 8
Important Product Information ...................................................8-9
Safety
Read the safety and operation instructions before using this thermometer.
Warnings
This Unit emits a laser beam which projects a
visible red spot on the target. Do not point laser
directly at eyes or indirectly off of a reective surface.
The laser beam’s emission power is less than 1mW
in class 2. Do not remove the label from this unit
630-670nm
continued ...
reedinstruments
www
com
3
Cautions
This unit is a precision instrument and must be handled with care
Avoid dust, water, shock, vibrations and extreme heat
Wipe the unit clean and dry with a soft cloth
Check the battery regularly to avoid deterioration
Turn off the unit when it is not in use
Remove the battery if unit is to be stored for a long period of time
Features
Specifications
Settings: Fm / Bm: switch measures
from front or rear of unit
M / FT: Switch measures in metric/imperial
(inside the battery compartment)
Measuring Range: 0.4m ~ 16m (20 in ~ 52 ft)
Accuracy: ± 0.4 within 6 m (20 ft) and ± 0.8 above 6m
Conditions: 0 ~ 40°C, 45% ~ 90%RH
Current Consumption: Stand-by current: ≤ 2 Ua;
Operating Current: 20 ~ 50mA
Auto Shut-off: 120 seconds
Response Time: 2 seconds
Power Supply: 9V alkaline battery
LCD Backlight: Active for 7 sec (approx)
Operation Environment: Temperature: 0 - 40°C
Humidity: 45% - 90%RH
Store Temperature: -10 - 60°C
Dimensions: 154mm x 61mm x 46mm
Weight: 190 g
Measures in imperial & metric
Start point selection
Data store/recall
Computes areas and volumes
5 groups of value in memory
Sum of lengths
Auto/Manual shut off
LCD backlight
Beeps for wrong reading nding
and reading conrmation
Laser point accuracy
reedinstruments
www
com
4
Instrument Description
1. Ultrasonic Sensor Aperture
2. Laser Point
3. Front Measurement
4. LCD
5. (FM) Front /
(BM) Base Measurement
6. Feet/Meter Conversion
7. READ Button
8. Volume Button
9. Area Button
10. Sum Button
11. Escape/Clear
12. Memory Recall
13. Memory Store
14. Power On/Off
15. Base Measurement
16. Hook
17. Battery Cover
reedinstruments
www
com
5
Operating Instructions
1. Properly insert a 9V alkaline battery in the battery compartment.
2. Turn the meter on. The default graphic on the screen will be 0.00m.
3. Select your unit of measure (metric or imperial) by pressing the
“FT / M” button.
4. Select a measurement starting point (the front or back of the unit).
Press the “Fm / Bm” button to change start point. The icon
will
display your starting point. The default of the unit is Fm.
5. After selecting your unit of measure and starting point,
point the Meter perpendicularly to the surface of which
you wish to measure. Press the “READ” button and after 1 second the
value will be shown on the LCD screen. If you keep holding the “READ”
button and start to move, dynamic readings will show.
reedinstruments
www
com
6
Additional Functions
Calculating Area
Press the “Area” button. Press the “READ” button to measure the value
of length. Aim in the next desired location and press the “READ” button
again to measure the width. The value of area will be displayed on the
LCD display screen.
Calculating Volume
Press the “Volume” button. Press the “READ” button to measure the value
of length. Aim in the next location and press the “READ” button again
to measure the width. Then aim in the nal measurement location and
press the “READ” button to measure Height. The value of volume will be
displayed on the LCD.
Calculating the Sum of Lengths
Take the rst reading of the length that you wish to be summed up by
pointing it at the surface you wish to measure and pressing the “READ”
button. Press the “Sum” button to begin the sum mode. Make another
measurement by pointing and pushing the “READ” button. Press the
“READ” button again and the sum will be displayed on the LCD. The SUM
function can only be use for length values operations. In metric the maxi-
mum sum is 100m, in imperial the maximum is 100ft.
Storage of Readings
This device has 10 memory slots. 5 memory slots are available for
different length and volume areas and 5 memory units are for sum data
storage. That data will be stored until the “ECS/CLEAR” button is pushed
or if the battery is replaced. Stored data stays stored in the unit’s memory
accordingly. When all of the unit’s memory is full, further storage
operation will not be implemented unless the “ECS/CLEAR” button is
pressed to delete one of unit’s stored data.
continued ...
reedinstruments
www
com
7
Change Reading when Measuring
If a reading needs to be conrmed for a changed start point, before
pressing “STORE” you may repress Read for measuring the linear
distance again.
Recall Function
When data is stored the LCD screen will display an “M” icon. In normal
status, press the Recall button to call for memorized lengths/areas/volumes.
The memorized data will display as follows:
For linear measurements, the LCD will only display the length
For area measurements, the LCD will display length, width and area
For volume measurements, the LCD will display length, width, height,
and volume
Recall Sum Data
After turning the unit on, press the Recall button to display SUM1 to SUM5.
The Sum data will be showed in order. When the memory unit is empty or
the data has been deleted the LCD will display 0.00m.
ESC/CLEAR Function
To clear your current measurement, after you press the Read button,
press the ESC/CLEAR button to clear the reading on LCD
To clear memorized data, press and hold the ESC/CLEAR button for more
than 3 seconds and all the data in the units memory will be cleared
When you are in other modes (Area, Volume, Sum), press the ESC/CLEAR
button and you will default back to Length measuring
Continuous Measurement Mode
Hold the READ button and work in the “dynamic reading” mode.
reedinstruments
www
com
8
Battery Replacement
1. When the LCD display shows low battery “ ”, it indicates the
battery output is either empty or has dropped below the operating
voltage require. Replacement of the batteries is now needed.
2. Turn off the meter and remove the battery cover with a screwdriver
to remove the battery.
3. Replace with a new 9V battery and reinstall the cover.
Important Product Information
For accurate results, choose a target surface that is large, at and hard.
Place a sufciently sized piece of cardboard in front of targets that are
too small.
The unit cannot measure through glass even though the laser beam
can pass through.
Choose the units and don’t change the units when you have chosen
the measure mode.
A strong wind could affect the units accuracy if the measuring distance
is greater than 12m.
The LCD backlight is active for 7 seconds and the device will
automatically shut off after 100 seconds of inactivity.
When the LCD screen indicates “low battery” power, replace the battery
to prevent a wrong measurement.
When accuracy is critical it is highly recommended that unit only be
used in these environments: indoors or windless within 0°C to 30°C,
45% RH to 90%RH. Temperature and humidity in different
environments affects the accuracy of the measurements.
This unit is using ultrasonic technology therefore the unit should be held
at a rectangular angle towards the surface of the subject being
measured. To assure the accuracy the rectangular angle should result in
less than +/- 5° deviations. For rough surface subjects, this unit can’t
reach the precise measures stated in this manual.
continued ...
reedinstruments
www
com
9
• When the device is out of range, not getting a return signal or no there is no
valid reading an “-ERROR-“ symbol will appear on the display with an alarm.
It is important to pay attention to the weather conditions to ensure the
best accuracy of your measurements.
When the target distance is more than 5 meters, the target must be
approximately 1.5 meters; when the target distance is more than 10
meters, the target must be approximately 2.5 meters.
See diagram below.
For service on this or any other REED product or information on other
REED products, contact REED Instruments at [email protected]
Distance
Target
reedinstruments
www
com
10
Notes _________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10

REED DM-01 User manual

Type
User manual

REED DM-01 is a measuring tool with many uses for both professionals and DIY enthusiasts. It has functions to help you measure lengths, areas, and volumes. It uses ultrasonic technology for accurate range finding and can take continuous measurements if you hold the button. It is also equipped with helpful measurement modes such as the start point selection and the sum of lengths. REED DM-01 is compact and lightweight and is powered by a single 9V alkaline battery that will last long thanks to the automatic shut-off feature.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI