6.5 Connecting the device to the gas supply
!
I
Observe the following instructions for the connection:
• Observe the national requirements.
• Use gas pipes made of steel Ø 8x1 mm (welded, seamless or stainless steel),
which are flush-mounted with a cutting ring screw assembly.
• Fasten the pipes on the side or rear wall of the surrounding furniture parts so that
no loads are exerted on the actuators.
• The connection must be executed in a way that it can only be released with tools.
Observe the technical regulations contained in the DVGW worksheets G607
and G608.
• The entire pipe system must be free from stress.
➤ Connect the pipes as shown (fig. c, page 7).
WARNING! Risk of serious injury
• This device may only be connected to the gas supply by a specialist
in accordance with the applicable guidelines and standards.
• A hose connection is not permitted.
• Use a metal-sealed screw connection.
• The gas line must not be twisted, pulled or subjected to any other
stress during the installation and connection work.
• The gas filter (white) in the oven gas connection must not be
removed.
• Only use cylinders of propane or butane gas (not natural gas or city
gas) with an approved pressure reduction valve and suitable head.
Compare the pressure information on the type plate with the pres-
sure information on the pressure regulator on the propane or butane
gas cylinder.
• Only operate the oven at the pressure shown on the type plate.
• Only operate the oven with the type of gas shown on the type plate.
• Note the pressures which are permitted in your country. Only use
pressure controllers with a fixed setting which comply with the
national regulations.
• It must be possible to disconnect the oven from the gas supply by
means of a main shut-off valve. The shut-off valve must be easily
accessible.
NOTE
Optionally, you can use the Dometic flexible gas connection pipe to
keep the installation tensionless.