Comtech EF Data LBC-4000 Operating instructions

Type
Operating instructions
IMPORTANT NOTE: The information contained in this document supersedes all previously published
information regarding this product. Product specifications are subject to change without prior notice.
Part Number MN/LBC4000.IOM Revision 4
LBC-4000
L-Band Up/Down Converter System
Installation and Operation Manual
Copyright © 2012 Comtech EF Data. All rights reserved. Printed in the USA.
Comtech EF Data, 2114 West 7th Street, Tempe, Arizona 85281 USA, 480.333.2200, FAX: 480.333.2161
LBC-4000
L-Band Up/Down Converter System
Installation and Operation Manual
Part Number MN/LBC4000.IOM
Revision 4
ii
Thispageisintentionallyblank.
iii
TABLE OF CONTENTS
TABLE OF CONTENTS .............................................................................................................. III
TABLES ..................................................................................................................................... VII
FIGURES ................................................................................................................................... VII
PREFACE ................................................................................................................................... IX
AboutthisMa
n
ual..............................................................................................................................ix
ReportingCommentsorSuggestionsConcerningthisManual...............................................................ix
ConventionsandReferences...............................................................................................................ix
PatentsandTrademarks..........................................................................................................................ix
Warnings,Cautions,andNotes................................................................................................................ix
ExamplesofMultiHazard Notices............................................................................................................x
RecommendedStandardDesignations.....................................................................................................x
MetricConversion.....................................................................................................................................x
SafetyandCompliance.........................................................................................................................x
ElectricalSafetyandCompliance..............................................................................................................x
ElectricalInstallation.................................................................................................................................x
OperatingEnvironment...........................................................................................................................xi
European Union RadioEqui pme ntandTelecommunicatio nsTerminalEquipment(R&TTE)
Directive(1999/5/EC )andEN 3014891..............................................................................................xi
European Union Electromagn etic Compatibility(EMC )Directive(2004/ 108/EC) .........................xi
EuropeanUnionLowVoltageDirective(LVD)(2006/9
5/EC)..............................................................xii
EuropeanUn
ionRoHSDire ctive(2002/95/EC)...................................................................................xii
EuropeanUnionTelecommunicationsTerminalEquipmentDirective(91/263/EEC)........................xii
CEMark...............................................................................................................................................xiii
WarrantyPolicy.................................................................................................................................xiii
LimitationsofWarranty..........................................................................................................................xiii
ExclusiveRemedies.................................................................................................................................xiv
GettingHelp.......................................................................................................................................xv
ContactingComtechEFData..................................................................................................................xv
ReturningaProductforUpgradeorRep
a
ir............................................................................................xvi
CHAPTER 1. INTRODUCTION ............................................................................................. 1–1
1.1 Overview..............................................................................................................................1–1
1.2 Features...............................................................................................................................1–1
LBC-4000 L-Band Up/Down Converter System Revision 4
Table of Contents MN/LBC4000.IOM
iv
1.2.1 DimensionalEnvelope...........................................................................................................1–3
1.3 FunctionalDescription..........................................................................................................1–4
1.4 SummaryofSpecifications....................................................................................................1–5
1.4.1 Physical&Environmental.....................................................................................................1–5
1.4.2 PrimePower..........................................................................................................................1–5
1.4.3 ExternalReference................................................................................................................1–5
1.4.4 Monitor&Control.................................................................................................................1–5
1.4.5 LBC4000LBandDownconverterIDU..................................................................................1–6
1.4.6 LBC4000LBandUpconve
r
terIDU.......................................................................................1–7
CHAPTER 2. INSTALLATION .............................................................................................. 2–1
2.1 UnpackingandInspectingtheShipment...............................................................................2–1
2.2 InstallingIntoaRackEnclosure.............................................................................................2–2
2.2.1 InstallingtheOptionalRearMountingSupportBracketsKit...............................................2–4
2.2.2 InstallingtheOptionalSideMountingBearinglessRackSlideSet.......................................2–6
2.3 ConnectingthePrimePower................................................................................................2–7
2.4 ConnectingExt
ernalCables................................................................................................... 2–7
2.5 RemovingorInstallingConverterModules...........................................................................2–7
CHAPTER 3. REAR PANEL CONNECTIONS ...................................................................... 3–1
3.1 CablingConnectionTypes.....................................................................................................3–1
3.1.1 CoaxialCableConnections....................................................................................................3–1
3.1.1.1Type‘BNC’.........................................................................................................................3–2
3.1.1.2Type‘TNC’.........................................................................................................................3–2
3.1.1.3Type‘N’.............................................................................................................................3–2
3.1.1.4Type‘F’..............................................................................................................................3–3
3.1.1.5Type‘SMA’(SubminiatureVersion‘A’).............................................................................3–3
3.1.2 DSubmi
n
iatureCableConnections......................................................................................3–3
3.1.3 CircularCableConnections...................................................................................................3–4
3.1.4 RJ45,RJ48CableConnections............................................................................................3–4
3.2 LBC4000CablingConnections.............................................................................................3–5
3.2.1 RF/IFConnectors...................................................................................................................3–6
3.2.1.1J4|RFOUT/INUnitBConnector(Type‘N’Female)........................................................3–6
3.2.1.2J5|IFIN
/OUTUnitBConnector(Type‘BNC’Female)....................................................3–6
3.2.1.3J6|RFOUT/INUnitAConnector(Type‘N’Female)........................................................3–6
3.2.1.4J7|IFIN/OUTUnitAConnector(Type‘BNC’Female) .....................................................3–6
3.2.2 UtilityConnectors.................................................................................................................3–7
3.2.2.1J2|EXTREF(ExternalRefe
rence)InputConnector(Type‘BNC’Female)........................3–7
3.2.2.2P1|RELAY(SummaryFaultOutput)Connector(DB9F)..................................................3–7
LBC-4000 L-Band Up/Down Converter System Revision 4
Table of Contents MN/LBC4000.IOM
v
3.2.2.3J1|COM1(EIA485/232Interface)Connector(DB9F)....................................................3–8
3.2.3 Optional1:1RedundancyConnectors..................................................................................3–9
3.2.3.1OptionalIFConnectors(Type‘BNC’Female)....................................................................3–9
3.2.3.2OptionalRFConnectors(Type‘SMA’Female)..................................................................3–9
3.3 LBC4000GroundandPowerConnections............................................................................3–9
3.3.1 ChassisGroundInterface....................................................................................................3–10
3.3.2 ChassisPowerInterfa
ces....................................................................................................3–10
3.3.2.1ACPrimePowerConnector.............................................................................................3–10
3.3.2.2DCFilterInputModule....................................................................................................3–10
3.3.2.3ApplyingPowertotheLBC4000....................................................................................3–11
CHAPTER 4. UPDATING FIRMWARE ................................................................................. 4–1
4.1 UpdatingFirmwareviatheInternet......................................................................................4–1
4.2 GettingStarted:PreparingfortheFirmwareDownload........................................................4–2
4.3 Do
wnloadingan
dExtractingtheFirmwareUpdate...............................................................4–5
4.4 PerformingtheFTPUploadProcedure..................................................................................4–7
CHAPTER 5. FRONT PANEL OPERATION ......................................................................... 5–1
5.1 Introduction.........................................................................................................................5–1
5.1.1 EnergizingtheLBC4000.......................................................................................................5–2
5.1.2 CONVAandCONVBLEDIndicators.....................................................................................5–2
5.1.3 Keypad...................................................................................................................................5–3
5.1.4 VacuumFluorescentDisplay(VFD).......................................................................................5–4
5.1.4.1OpeningScre
en.................................................................................................................5–4
5.1.4.2ScreenSaver......................................................................................................................5–4
5.2 SELECT:(Main)Menu............................................................................................................5–5
5.2.1 SELECT:Config(Configuration)Menus.................................................................................5–6
5.2.1.1Config:ConvAorConvB(ConverterUnitAorUnitB)....................................................5–7
5.2.1.2CONFIGRemote(RemoteControl)...................................................................................5–8
5.2.1.3Config:Redund(Redundancy)..........................................................................................5–9
5.2.1.4Config:RefAd
j(ReferenceOscillatorAdjustment)............................................................5–9
5.2.2 SELECT:Monitor..................................................................................................................5–10
5.2.3 SELECT:Faults.....................................................................................................................5–11
5.2.3.1 FAULTSÆStored........................................................................................................5–11
5.2.4 SELECT:Util(Utility)............................................................................................................5–12
5.2.4.1UTIL:Clock.......................................................................................................................5–13
5.2.4.2UTIL:LEDtst(FrontPanelLEDTest)................................................................................5–13
5.2.4.3UTIL:Relay.......................................................................................................................5–13
5.2.4.4UTIL:VFD(Va
c
uumFluorescentDisplayBrightnessAdjustment)..................................5–14
5.2.4.5UTIL:ScrSaver..................................................................................................................5–14
5.2.4.6UTIL:FWinfo....................................................................................................................5–15
LBC-4000 L-Band Up/Down Converter System Revision 4
Table of Contents MN/LBC4000.IOM
vi
5.2.4.7UTILÆApID(ApplicationID)..........................................................................................5–16
CHAPTER 6. SERIAL-BASED REMOTE PRODUCT MANAGEMENT ................................ 6–1
6.1 Introduction.........................................................................................................................6–1
6.1.1 EIA485..................................................................................................................................6–2
6.1.2 EIA232..................................................................................................................................6–2
6.2 RemoteCommandsandQueriesOverview........................................................................... 6–3
6.2.1 BasicProtocol........................................................................................................................6–3
6.2.2 PacketStructure....................................................................................................................6–3
6.2.2.1StartofPacket...................................................................................................................6–4
6.2.2.2TargetAddress..................................................................................................................6–5
6.2.2.3AddressDeli
miter..............................................................................................................6–5
6.2.2.4InstructionCode................................................................................................................6–5
6.2.2.5InstructionCodeQualifier.................................................................................................6–6
6.2.2.6OptionalMessageArguments...........................................................................................6–7
6.2.2.7EndofPacket....................................................................................................................6–7
6.3 RemoteCommandsandQueries...........................................................................................6–8
APPENDIX A. UP/DOWNCONVERTER IDU MODULE REMOVAL/RE-INSTALLATION . A–1
A.1 Introduction.........................................................................................................................A–1
A.2 IDUModuleRemovalProcedure...........................................................................................A–2
A.3 IDUModuleI
n
stallationProcedure.......................................................................................A–5
APPENDIX B. LBC-4000 REDUNDANCY OPERATION ..................................................... B–1
B.1 Introduction.........................................................................................................................B–1
B.2 RedundancyOperationsOverview........................................................................................B–1
B.3 RedundancyOperationsviatheLBC4000FrontPanel..........................................................B–3
B.3.1 MainMenu............................................................................................................................B–4
B.3.2 CONFIG(Configuration)Menu..............................................................................................B–5
B.3.3 CONFIG:Redund(Redundancy)............................................................................................B–6
B.3.4 GainOffsetforRedundan
tOperations.................................................................................B–7
B.4 RedundancyOperationsviaSerialRemoteControl...............................................................B–8
LBC-4000 L-Band Up/Down Converter System Revision 4
Table of Contents MN/LBC4000.IOM
vii
TABLES
Table31.LBC4000Connectors...............................................................................................................3–5
Table32.P1|RELAYConnectorPinouts.................................................................................................3–7
Table33.J1|COM12WireEIA485InterfaceConnectorPinouts.........................................................3–8
Table34.J1|COM14WireEIA485InterfaceConnectorPinouts.........................................................3–8
Table35.J1|COM1EIA232Interfac
eConnectorPinouts.....................................................................3–8
Table36.DCInputFilterModulePinouts..............................................................................................3–10
FIGURES
Figure11.ComtechEFDataLBC4000LBandUp/DownConverter.......................................................1–1
Figure12.LBC4000FrontandRearPanels(RedundantUnitShown)....................................................1–2
Figure13.LBC4000DimensionalEnvelo pe............................................................................................1–3
Figure14.LBC4000TypicalApplicationBlockDiagram.........................................................................1–4
Figure21.Unpackingan
dInspectingtheLBC4000................................................................................2–1
Figure22.InstallingintoaRackEnclosure..............................................................................................2–3
Figure23.InstallingtheOptionalRearMountingSupportBracketsKit................................................2–4
Figure24.InstallingtheOptionalSideMountingBearinglessRackSlideSet.........................................2–6
Figure31.CoaxialConnectorExamples...................................................................................................3–1
Figure32.DSubmin
iatureConnectorExamples.....................................................................................3–3
Figure33.LBC4000RearPanelConnectors(RedundancyUnitShown)................................................3–5
Figure34.LBC4000GroundandPowerInterfaces................................................................................3–9
Figure51.LBC4000FrontPanel.............................................................................................................5–1
Figure52.LBC4000FrontPanelMenuTree ...........................................................................................5–5
FigureA1.LBC4000ChassisIDUMo
duleBays....................................................................................A–1
FigureB1.LBC4000RedundancyFunctionalSch ematic......................................................................B–2
FigureB2.LBC4000RedundancyCablingSchematic..............................................................................B–2
FigureB3.LBC4000FrontPanel.............................................................................................................B–3
LBC-4000 L-Band Up/Down Converter System Revision 4
Table of Contents MN/LBC4000.IOM
viii
Thispageisintentionallyblank.
ix
PREFACE
About this Manual
ThismanualprovidesinstallationandoperationinformationfortheComtechEFDataLBC4000
LBandUp/DownConverterSystem.Thisisaninformationaldocumentintendedforthepersons
responsiblefortheoperationandmaintenanceoftheLBC4000.
Reporting Comments or Suggestions Concerning this Manual
ComtechEFDatawelcomescommentsandsuggestionsregardingthecontentanddesignofthis
manual.ContacttheComtechEFDataTechnicalPublicationsDepartment:
Conventions and References
Patents and Trademarks
SeeallofComtechEFData'sPatentsandPatentsPendingathttp://patents.comtechefdata.com.
ComtechEFDataacknowledgesthatalltrademarksarethepropertyofthetrademarkowners.
Warnings, Cautions, and Notes
A WARNING
gives information about a possible hazard that MAY CAUSE DEATH
or SERIOUS INJURY.
A CAUTION
gives information about a possible hazard that MAY CAUSE INJURY
or PROPERTY DAMAGE.
A NOTE
gives important information about a task or the equipment.
A REFERENCE
directs the user to additional information about a task or the
equipment.
LBC-4000 L-Band Up/Down Converter System Revision 4
Preface MN/LBC4000.IOM
x
Examples of Multi-Hazard Notices
Recommended Standard Designations
Recommended Standard (RS)Designati onshavebeen superseded by the new designation of the
Electronic Industries Association (EIA). References to the old RS designation (e.g., RS232) may
appear when depicting actual text on the serial interface or the physical unit (e.g., front panel
menusorrearpanellabe lin g).Allotherreferencesinthemanu
alspec if ytheEIAdesignation s .
Metric Conversion
ComtechEFDataprovidesnonMetric toMetricconversionstables on the insidebackcoverof
thismanualtoassisttheoperatorincrossreferencingsuchinformation.

The user should carefully review the following information:
Safety and Compliance
Electrical Safety and Compliance
TheunitcomplieswiththeEN60950SafetyofInformationTechnologyEquipment(Including
ElectricalBusinessMachines)safetystandard.
IFTHEUNITISOPERATEDINAVEHICLEORMOVABLEINSTALLATION,MAKESURE
THEUNITISSTABLE.OTHERWISE,EN60950SAFETYISNOTGUARANTEED.
Electrical Installation
CONNECTTHEUNITTOAPOWERSYSTEMTHATHASSEPARATEGROUND,LINEAND
NEUTRAL CONDUCTORS. DO NOT CONNECT THE UNIT WITHOUT A DIRECT
CONNECTIONTOGROUND.
LBC-4000 L-Band Up/Down Converter System Revision 4
Preface MN/LBC4000.IOM
xi
Sect3.3LBC4000GroundandPowerConnections
Operating Environment
DONOTOPERATETHEUNITINANYOFTHESEEXTREMEOPERATINGCONDITIONS:
AMBIENT TEMPERATURES LESS THAN C (32° F) OR MORE THAN 50° C
(122°F).
PRECIPITATION, CONDENSATION, OR HUMID ATMOSPHERES OF MORE
THAN95%RELATIVEHUMIDITY.
UNPRESSURIZEDALTITUDESOFMORETHAN2000METRES(6561.7FEET).
EXCESSIVEDUST.
FLAMMABLEGASES.
CORROSIVEOREXPLOSIVEATMOSPHERES.
European Union Radio Equipment and Telecommunications Terminal
Equipment (R&TTE) Directive (1999/5/EC) and EN 301 489-1
IndependenttestingverifiesthattheunitcomplieswiththeEuropeanUnionR&TTEDirective,its
reference to EN301 4891 (Electromagnetic compatibility and Radio spectrum Matters [ERM];
ElectroMagnetic Compatibility [EMC] standard for radio equipment and services, Part 1:
Common technical requirements), and the Declarations of Conformity for the applicable
directives,standards,andpracticesthatfollow:
European Union Electromagnetic Compatibility (EMC) Directive
(2004/108/EC)
Emissions: EN 55022 Class B Limits and Methods of Measurement of Radio
InterferenceCharacteristicsofInformationTe chnologyEquipment.
Immunity: EN 55024 Information Technology Equipment: Immunity Characteristics,
Limits,andMethodsofMeasurement.
EN6100032HarmonicCurrentsEmission
EN6100033VoltageFl
uctuationsandFlicker.
FederalCommunicationsCommissionFeder
alCodeofRegulationFCCPart15,SubpartB.
LBC-4000 L-Band Up/Down Converter System Revision 4
Preface MN/LBC4000.IOM
xii
TOENSURETHATTHEUNITCOMPLIESWITHTHESESTANDARDS,OBEYTHESE
INSTRUCTIONS:
Use coaxial cable that is of good quality for connections to the LBand Type ‘N’ Rx
(receive)femaleconnector.
UseType'D'connectorsthathavebackshellswithcontinuousmetallicshielding.
Type‘D’cablingmusthaveaconti
nuou
soutershield(eitherfoilorbraid,orboth).The
shieldmustbebondedtothebackshell.
Operatetheunitwithitscoveronatalltimes.
European Union Low Voltage Directive (LVD) (2006/95/EC)
Symbol Description
<HAR> TypeofpowercordrequiredforuseintheEuropeanCommunity.
CAUTION:Doublepole/NeutralFusing
ACHTUNG: Zweipoligebzw.NeutralleiterSicherung

InternationalSymbols
Symbol Definition Symbol Definition
AlternatingCurrent ProtectiveEarth
Fuse
ChassisGround
Foradditionalsymbols,refertoWarnings,CautionsandNoteslistedearlierinthis
Preface.
European Union RoHS Directive (2002/95/EC)
Thisunitsatisfies(withexemptions)therequirementsspecifiedintheEuropeanUnionDirective
on the Restriction of Hazardous Substances in Electrical and Electronic Equipment (EU RoHS,
Directive2002/95/EC).
European Union Telecommunications Te
rminal Equipment Directive
(91/263/EEC)
In accordance with the European Union Telecommunications Terminal Equipment Directive
91/263/EEC, the unit should not be directly connected to the Public Telecommunications
Network.
!
LBC-4000 L-Band Up/Down Converter System Revision 4
Preface MN/LBC4000.IOM
xiii
CE Mark
ComtechEFDatadeclaresthattheunitmeetsthenecessaryrequirementsfortheCEMark.
Warranty Policy
ComtechEFData productsarewarranted againstdefectsinmaterialandworkmanship
for a specific period from the date of shipment, and this period varies by product.In
mostcases, the warrantyperiodis two years. During thewarranty period, ComtechEF
Datawill,atitsoption,repairorreplaceproductsthatprovetobedefective.Repairsare
warranted for the remainder of the original warranty or a 90 day extended warranty,
whichever is longer. Contact Comtech EF Data for the warranty period specific to the
productpurchased.
Forequipment underwarranty,the owner isresponsibleforfreightto ComtechEFData
andallrelatedcustoms,taxes,tariffs,insurance,etc.ComtechEFDataisresponsiblefor
the freight charges only for return of the equipment from the factory to the owner.
Comtech EF Data will return the equipment by the same method (i.e., Air, Express,
Surface)asthe equipmentwassenttoComt echEFData.
Allequipmentreturnedforwarrantyrepairmusthavea validRMAnumberissuedprior
to return and be marked clearly on the return packaging.Comtech EF Data strongly
recommendsallequipmentbereturnedinitsoriginalpackaging.
ComtechEFDataCorporation’s obligationsunder thiswarrantyare limitedtorepair or
replacement of failed parts, and the return shipment to the buyer of the repaired or
replacedparts.
Limitations of Warranty
The warranty does notapply to any part of aproduct thathas beeninstalled, altered,
repaired, or misused in any way that, in the opinion of Comtech EF Data Corporation,
wouldaffectthe reliabilityordetractsfromtheperformanceofanypartoftheproduct,
or is damaged as the result of use in a way or with equipment that had not been
previouslyapprovedbyComtechEFDataCorporation.
Thewarrant ydo esnotapplytoanyproductorpartsthereofwheretheserialnumberorthe
serialnumberofan yofitspartshasbeenaltered,defaced,orremoved.
Thewarr
antydoesnotcoverdamageorlossincurredintransportationoftheproduct.The
warrantydoesnotcoverreplacementorrepairnecessitatedbylossordamagefromany
cause beyond the control of Comtech EF Data Corporation, such as lightning or other
naturalandweatherrelatedeventsorwartimeenvironments.
LBC-4000 L-Band Up/Down Converter System Revision 4
Preface MN/LBC4000.IOM
xiv
Thewarranty doesnot cover anylaborinvolved inthe removal andorreinstallation of
warrantedequipment or parts on site, or any labor required to diagnose the necessity
forrepairorreplacement.
Thewarrantyexclud esanyrespons ibilitybyComtechEFDataCorporationforincidentalor
consequential damages arising from the use of the equipment or products, or for any
inabilitytousethemeitherseparatefromorincombinationwithanyotherequipmentor
products.
Afixedchargeestablishedforeachproductwillbeimposedforallequipmentreturned
forwarrantyrepairwhereComtechEFDataCorporationcannotidentifythecauseofthe
reportedfailure.
Exclusive Remedies
Comtech EF Data Corporation’s wa rr anty , as stated is in lieu of all oth e r warranties,
expressed, implied, or statutory, including those of merchantability and fitness for a
particularpurpose.The buyershallpassontoanypurchaser,lessee,orotheruserof
Comtech EF Data Corporation’s products, the aforementioned warranty, and shall
indemnifyandhold harmlessComtechEFDataCorporationfromanyclaimsor liability
ofsuchpurchaser,lessee , oruserbaseduponallegationsthatthebuyer,itsagents,or
employees have made additional warranties or representations as to product
preferenceoruse.
Theremediesprovidedhereinarethebuyer’ssoleandexclusiveremedies.ComtechEF
Data shall not be liable for any direct, indirect, special, incidental, or consequential
damages,whetherbasedoncontract,tort,oranyotherlegaltheory.
LBC-4000 L-Band Up/Down Converter System Revision 4
Preface MN/LBC4000.IOM
xv
Getting Help
Contacting Comtech EF Data
ContactComtechEFDatafor:
TechnicalSupportProductsupportortraining.
CustomerServiceInformationonreturninganinwarrantyoroutofwarrantyproductfor
upgrade or repair. Be prepared to provide the product model number and its serial
number.
ContactComtechEFDataCustomer&TechnicalS
upportduringnormalbusinesshours(Monday
throughFriday,8A.M.to5P.MMountainStandardTime(MST)):
For: Contact:
LBC4000
Technical
Supportand
Service
Telephone +1.480.333.4357
Email [email protected]
Fax +1.480.333.2500
ComtechEF
DataWebSite
MainPage http://www.comtechefdata.com
Customerand
TechnicalSupport
http://www.comtechefdata.com/supp ort.asp
RMA
(ReturnMaterial
Authorization)
http://www.comtechefdata.com/rmaform.asp
ComtechEFDataMai nNumber +1.480.333.2200
MailingAddress
2114West7thStreet
Tempe,Arizona85281USA

Review the Warranty Policy before contacting Comtech EF Data Technical Support or
Customer Service.
LBC-4000 L-Band Up/Down Converter System Revision 4
Preface MN/LBC4000.IOM
xvi
Returning a Product for Upgrade or Repair
Step Task
1
GototheComtechEFDataHomepage(http://www.comtechefdata.com).From
theSUPPORT columnatthebottomofthepage,selecttheServicehyperlink,and
readtheReturnMaterialAuthorizationsectioninitsentirety.
2 RequestaReturnMaterialAuthorizationNumber:
OntheComtechEFDataHomepage:FromtheSUPPORTcolumnatthe
bottomofthepage,selecttheRMARequesthyperlink;
OR
OntheComtechEFDataSupportpage:Click[SendRMARequest];
OR
OntheComtechEFDataSer
v
icepage:SelecttheReturnMaterial
Authorizaionhyperlink;
FillouttheRMAformcompletely;
Click[SendEmail].
Alternately:
SendanemailprovidingthissamedetailedinformationtoComtechEFData
CustomerService([email protected]).
ContactComtechEFDataCustomer&Te
chnicalS
upportbyphoneorfax.
3 Packtheproductinitsoriginalshippingcartonandprotectivepackaging.
4 ShiptheproductbacktoComtechEFData.Shippingchargesshouldbeprepaid.
1–1
Chapter 1. INTRODUCTION
1.1 Overview
ComtechEFData’sLBC4000LBandUp/DownConverterSystem(Figure11)isdesignedto
interfacelegacy70MHzor140MHzequipmenttotribandorquadbandblockconverters.
Figure 1-1. Comtech EF Data LBC-4000 L-Band Up/Down Converter
1.2 Features
Figure12showsthefrontandrearpanelsoftheLBC4000.TheLBC4000isa1RUhigh,19inch
widechassis(Figure13)thatisdesignedformountingintoastandard19
inchequipmentrack.
The front panel handles allow quick installation into and removal of the unitfrom the
equipmentrack.Theunitmayalsobefreestandingifdesired.
The LBC4000 dropdown front panel provides access to the ON/OFF switch and bays for two
upconverter
modules,ortwodownconvertermodules,oroneofeach.
Alloperatorcontrols,indicatorsanddisplaysarelocatedontheLBC4000frontpanel.
External interface connectors, including those intended for serial remote Monitor and Control
(M&C),arelocatedontheLBC4000rearpanel.
LBC-4000 L-Band Up/Down Converter System Revision 4
Introduction MN/LBC4000.IOM
1–2
Feature Description
1 Rack Handles
2 On/Off Switch
3 LED Indicator Groups
4 Keypad
5 Vacuum Fluorescent Display (VFD)
6 Converter ‘A’ IDU Module Bay
7 Converter ‘B’ IDU Module Bay
Top:FrontPanelinOperatingandServicePositions
Bottom:RearPanel
Figure 1-2. LBC-4000 Front and Rear Panels (Redundant Unit Shown)
.
LBC4000feature(s):
MeetorexceedMILSTD188164A Lowphasenoise
1kHzstepsize Nospectralinversion
50dBgainadjustment Autobandsensingcapability
EIA485/232MonitorandControl
(M&C)
70MHz±18MHzIF(140MHz±36
MHzoptional)
Flexibleconfiguration 1:1redundancyavailability
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108

Comtech EF Data LBC-4000 Operating instructions

Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI