Technical specs
Mechanical features
Format 3½” standard
Size 88 x 102 x 54 mm
Weight
212 g
Protocol interfaces
Pulse, modifiable CCTALK
Electrical features
Supply voltage min. 12 VDC (8 VDC min)
Supply voltage max.
24 VDC (28 VDC max)
Acceptance
350 mA(30 ms)/100 mA
Measuring
≤25 mA
Stand by ≤30 mA
Standard enegy save ≤5 mA
Self- wake up ≤7,5 mA
Output voltage max. 50 V (OC, active low)
Output current max. 250 mA
Input trigger voltage min. 3 V (OC, active high)
Input voltage max 50 V (OC, active high)
Input impedance ≈55 kΩ
Coin acceptance
Coin channels number 16
Coin diametre min. 16 mm
Coin diametre max. 32 mm
Coin thickness 1 to 3,4 mm
Speed 3 coins/sec (V) – 4 coins/sec (S, K, I)
Timing data
Power-up recovery time ≤200 ms
Wake-up recovery time ≤50 ms
Pulse or time out tolerance ± 2%
Ambient conditions
Working ambient temperature 0°C to 60°C
Storage temperature -30°C to 70°C
Humidity up to 75% (non condensing) for standard
up to 95% for tropicalized version
EMC performance
This product is compliant with EN55014-1 and EN55014-2 test specification
> 8-bit top-performing CPU microcontroller with 32 KB Flash-memory, highly
immune to magnetic interference and to environmental conditions.
> 13 discriminating parameters.
> 6 magnetic sensors and 2 optic detectors combine to guarantee the most
accurate capacity of discrimination. Data-digitizer interface designed to cope
at best with bi-metal and magnetized coins. The system sharpens selectivity
and security, and makes the programming process easy and fast.
> 1 wire-clipper and 2 wire-tearers in version V provide mechanical shielding
against fishing-fraud. Coin-Guard anti-cheat system, based on the synergy of
3 suitably positioned optic sensors.
QUICK
GUIDE
AL66
FG
MOD
.
CCTALK
,
1 of 6
AL66 FG
modifiable ccTalk
COIN ACCEPTOR
Quick Guide
Rev. 1.03
Connections
The selectors connects to other peripherals and to the main board by the following connectors:
X1. Power supply and standard interface.
Connector X1 is an IDC 10-p socket, whose pin-out is
shown in grid aside.
It allows connection to the 3-way or 5-way sorter (see
sorters explanation below).
nr. Description
1 Gnd
2 +8-28 Vdc
3 Out 5 / sorter coil B
4 Out 6 / sorter coil A
5 Out 7 (totalizer) / In 2
6 In 1 (inhibit)
7 Out 1
8 Out 2
9 Out 3
10 Out 4 / sorter coil C
X2. SPI / Display.
The 8-p socket X2
permits connection to
various intelligent
periphearl units (i.e.
active sorter, encryption
module, a.s.o.) or to the
display.
Nr. & Description
1 Gnd 5 5 Select
2 +12-24Vdc
6 Data IN
3 Logic GND 7 Data OUT
4 +5 Vdc 8 Clock
The display function must be factory-preset
and/or modified by the Alberici programming
software. The following models are supported:
- MC 14499 (4 digits), compatible with the
RM924S SECI or with G-51.1092 NRI
- MC 14489 (5 digits) compatible with the
G-53.0747 NRI
- MAX 7219 (6 digits)
- M643 (8 digits) LCD
- AD01 (2 x 16 digits)
X3. CCTALK. The X3 4-p socket is for serial ccTalk® communication
with the main board. The protocol is preset for “slave mode”
operation, and is described in AL66 technical manual, Chapter 6.
This socket can be used on standard selectors and on modifiable
ccTalk selectors to change the programme of the selector by PC (USB
port) and Alberici free software.
nr. Descrizione
1 Data
2 Gnd
3 NC
4 +12 Vdc
X4. USB Mini-B (option). The USB port allows to drive the acceptor directly
from the USB port of a PC Mother Board. The USB port provides only the
communication channel: the communciation itself will run by serial ccTalk®
protocol, that must therefore be implemented in the Motherboard software.
TAKE CARE! The coin selector must be installed 90°-95° with respect to level plane. Because of the built-in advanced
security system, it is essential that the whole coin path gets not hindered.
Alberici is not responsible for any malfunctioning due to lack of compliance with such recommendations.
TO INHIBIT 50 €c, 1 € and/or 2 € COINS, MOVE THE
CORRESPONDING DIP-SWITCH TO OFF END (see grid aside).
THEN SWITCH OFF AND ON AGAIN.
dip-switch nr. in
row SW1
corresponding coin
1 2,00 €
2 1,00 €
3 0,50 €
THE DISCRIMINATIONG CAPACITY OF THE ACCEPTOR
CAN BE INCREASED BY MOVING THE DIP-SWITCH 6 OF
ROW SW2 TO POSITION ‘OFF’.
Position of
dip-switch 6
(row SW2)
Discrimination
capacity
ON
Normal acceptancy
OFF
Tight acceptancy
(anti-fakes)
QUICK
GUIDE
AL66
FG
MOD
.
CCTALK
,
2 of 6
HOW TO SET THE ACCEPTANCE RATE LEVEL
INHIBITION OF PROGRAMMED COINS
Dimensions
Driving the NL3, NS3 and VARIANT sorters
To attribute the cctalk sorting commands, please refer to the output paths shown below for our sorters:
Implementing the Cctalk commands
The complete description with examples of ccTalk commands is given in our AL66 Technical
manual (download it from our web site
www.alberici.net ). The following page shows a
summary table of the implemented commands.
QUICK
GUIDE
AL66
FG
MOD
.
CCTALK
,
3 of 6
SORTING COMMANDS
CCTALK SORTERS (PULSE SORTERS)
Dir 1 = cctalk 01 activates Dir 1 = no OUT
Dir 2 = cctalk 02 activates Dir 2 = OUT 5
Dir 3 = cctalk 03 activates Dir 3 = OUT 6
Dir 4 = cctalk 06 activates Dir 4 = OUT 4 + OUT 5
Dir 5 = cctalk 07 activates Dir 5 = OUT 4 + OUT 6
VARIANT
3-5 way
NS3 NL3
Code Command header Note
255
FF Factory specific test Supported
254 FE Simple poll Return ACK
253 FD Address poll MDCES support
252 FC Address clash MDCES support
251 FB Address change MDCES support, non volatile
250 FA Address random MDCES support, non volatile
249 F9 Request polling priority [02][32] 100x50=500 ms
248
F8 Request status [00] Ok
246 F6 Request manufacturer id 'Alberici'
245 F5 Request equipment category id 'Coin Acceptor'
244 F4 Request product code 'ALNNxn' NN=55/66, x=V/I/K, n=1-3
243 F3 Request database version [01] remote file programming
242 F2 Request serial number From 0 to 16.777.215
241 F1 Request software revision 'u3.n p3.m' n=0..9, m=0..9
240 F0 Test solenoids Coil on for 100 ms
238
EE Test output lines Supported
237 ED Read input lines [In1=MSb,DIP-sw1][In2=MSb,DIP-sw2]
236 EC Read opto states bit0=opto1, bit1=opto2
233
E9 Latch output lines Supported
232 E8 Perform self test Supported
231 E7 Modify inhibit status [inhibit 1][inhibit 2] total 16 position, volat.
230 E6 Request inhibit status Supported
229 *
E5 Read buffered cred. or error c. Five two byte event buffer
228 E4 Modify master inhibit status bit0=0 inhibited ..1=enable, volatile
227 E3 Request master inhibit status Supported
226 E2 Request insertion counter [Rjct1-MSB][ Rjct2][ Rjct3-LSB]
225 E1 Request acceptance counter [Rjct1-MSB][ Rjct2][ Rjct3-LSB]
221
DD Request sorter override status [FF] Normal sorting
219 DB Enter new PIN number Supported, non volatile
218 DA Enter PIN number ACK return if PIN is correct
216 D8 Request data storage availability [00][00][00][00][00], not available
215
D7 Read data block For encrypted data exchange!
214
D6 Write data block For encrypted data exchange!
213 D5 Request option flags bit0=0 cred. code format position
210 D2 Modify sorter paths [coin pos][path], volatile
209 D1 Request sorter paths Supported
202
CA Teach mode control Supported
201
C9 Request teach status Supported
197 C5 Calculate ROM checksum [ROM-H][ROM-L][EEPR-H][EEPR-L]
196 C4 Request creation date Supported
195 C3 Request last modification date Supported
194 C2 Request reject counter [Rjct1-MSB][ Rjct2][ Rjct3-LSB]
193 C1 Request fraud counter [Frd1-MSB][ Frd2][ Frd3-LSB]
192 C0 Request build code 'AL55 V1.0' (modifiable version)
188
BC Request default sorter path [01] No sorting
185
B9 Modify coin id Supported
184 B8 Request coin id Supported
176 B0 Request alarm counter Supported, one byte cumulative count
173
AD Request thermistor reading If thermistor is mounted
170 AA Request base year '2000'
169 A9 Request address mode [84] addr. change non volatile(FLASH)
4 04 Request comms revision [02][04][02] ,level2, isue4.2
3 03 Clear comms status variables Supported
2 02 Request comms status variables [Rx timeout][ Rx b. ignored][ Rx bad chks.]
1 01 Reset device Software reset
(*) The error codes are not supplied by default. It is possible to preset the acceptor to transmit error codes, only
IF REQUESTED WHEN PLACING YOUR ORDER FOR THE ACCEPTOR. See page 6 for Error codes listing .
QUICK
GUIDE
AL66
FG
MOD
.
CCTALK
,
4 of 6
LISTING of ERROR CODES
(AVAILABLE FROM THE ACCEPTOR UPON REQUEST WHEN PLACING YOUR ORDER)
INSTRUCTIONS TO MODIFY THE AL66 “OPEN” CCTALK ACCEPTOR
(only for Countries other than ITALY, where restricted CCTALK protocol applies)
- Modify the existing programme by PC through our K-P1C-000009 interface kit,
connected to the PC USB serial port.
1 Download the package including the drivers for the programming interface tool and
the application “AlbericiCoinSelector.exe” (from our web site http://www.alberici.it,
“Downloads” section). Install the drivers into your PC, then install the
application; the icon here aside will be shown on your PC Desktop: .
2 Make use of the programming-testing-power tool K-P1C-000009.
3 Make sure that voltage supply is off.
4 Connect the USB port of the PC to the USB A port of the interface.
5 Connect the 4pin cable between the ccTalk output
of the interface and the 4-pin socket (X3) of the acceptor.
6 Connect the 10pin flat cable between the STD output of
the interface and the 10pin socket (X1) of the acceptor:
7 Turn the power supply to selector on (green pushbutton on the interface tool).
8 Launch the application and modify the acceptor’s data appearing on the screen
according to your needs. The software interface is very simple and user-friendly; in
case, its Instruction Manual is also available on the same page of our web site.
9 Download the new configuration to the coin acceptor, switch power supply to selector
off and then on again.
10 Test that operation corresponds to the new configuration programmed.
11 Switch power off and disconnect the selector from the PC USB port.
QUICK
GUIDE
AL66
FG
MOD
.
CCTALK
,
5 of 6
QUICK
GUIDE
AL66
FG
MOD
.
CCTALK
,
6 of 6
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Alberici AL66 FG modifiable ccTalk Quick Manual

Type
Quick Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI