Channel Plus H612 User manual

Type
User manual
110D-4
J8
Blu
110D-4
J7
Blu
RJ-45
J9
RJ-45
J10
110D-4
J1
110D-4
J2
110D-4
J3
110D-4
J4
110D-4
J5
110D-4
J6
BluBluBluBluBluBlu
TelephonesExpansion
Ports
In
Out
ChannelPlus model H618
Telephone Expansion Hub (4 lines x 8 phones)
R
T
R
T
R
T
R
T
4
3
2
1
Solid Color
Twisted-Pair Wire
6 position connectors
8 position connectors
T
T
T
T
R
R
R
T
RT
T
R
TR
R
TT
R
RR
1
1
1
12
2
2
23
3
3
34
4
4
45
5
57
56
6
68
6
PR2
PR1
PR3
PR2
PR1
PR2
PR1
PR3
PR4
PR1
RJ-11
Single line telephones,
answering machines &
modems
RJ-14
Dual line telephones &
answering machines
RJ-25
Rare
3lineKSU
RJ-45 (wired to TIA T568A standard)
Ethernet (both 10BaseT and 100BaseT)
Structured wiring of phones and data lines
(There are other wiring standards. For
residential use, w RJ-45
jacks be wired to the T568A standard.)
e recommend that
Follow color code for T568A jacks.
Position first pair to channel closest
to end of jack. (Do not untwist
conductor pairs more than 0.5"
from the termination point.)
Keep sheath
close to jack.
1
Using a 110 punch-down tool,
push wires into channels
Repeat for subsequent pairs.
and trim.
110 punch-
down tool
110 punch-
down
tool
2
When all conductor pairs are
terminated, snap on strain relief caps.
3
Wiring Modular Plug (T568A)
Wiring a Cat-5 jack
Keep sheath close to connector
Untwist .5” max.
110 punch down tool
The 110 is a sophisticated insulation
displacement connection system. To
push the wire between the contact
blades, use only a
a screwdriver or needle
nose pliers may not seat the wire
properly and can damage the contacts.
110 punch down
tool. Using
Note order of colors
From telephone
company exchange
2 lines
H618 telephone
expansion hub
CAT-5 jumper
(included)
Install this jumper for normal
operation. Remove to disconnect
telephone service from the system.
2 lines to telephone
wall plates.
Each line is individually surge protected to 50 Joules and
4000 Amps. Some surges contain sufficient energy that
although your system has been protected, the surge
circuit will be unable to provide additional protection.
When this happens, the red light for that line will turn on
and the module needs to be returned for service.
CAT-5, 4 UTP RG-6 coax
Telephone
(in house)
Telephone
(from telco)
Data
Security
Downstream/External
(to TVs)
Upstream/Internal
(from modulators)
Insert wires in this order:
White/Green
Green
White/Orange
Blue
White/Blue
Orange
White/Brown
Brown
ChannelPlus model H612
Telephone Entry Module (surge,disconnect)
4
3
2
1
From NTE
1
2
Disconnect
In Out
Expansion
Output
Surge
Warning
Line 2
Line 1
5
6
3
2
1
4
5
6
5
Line 2
2
3
5
Line 1
2
3
Telephone
Output
H612
ChannelPlus model H612
Telephone Entry Module (surge,disconnect)
4
3
2
1
From NTE
1
2
Disconnect
In Out
Expansion
Output
Surge
Warning
Line 2
Line 1
5
6
3
2
1
4
5
6
5
Line 2
2
3
5
Line 1
2
3
Telephone
Output
Line 1
Line 2
2
3
5
2
3
5
Modular connectors
Wiring a 110 connector
Wire Color Codes
Colors of OpenHouse wiring
tm
green
black
white
red
yellow
blue
TIP
TIP
TIP
TIP
RING
RING
RING
RING
Cat5
4 pair UTP
blue/white
blue
orange/white
orange
green/white
green
brown/white
brown
pair 1
pair 2
pair 3
pair 4
pair 1
pair 2
pair 3
ChannelPlus Telephone Entry Module
The provides a superior method
of telephone connection to your system. Each unit provides
surge suppression for two lines and a master disconnect. Also,
each line has an LED
status indicator to warn
you of a surge event.
H612 Telephone Entry Module
Typical Installation
IMPORTANT INSTRUCTIONS
When using your telephone equipment, basic precautions should
always be followed to reduce the risk of fire, electric shock and
injury to persons, including the following:
1. Read and understand all instructions
2. Do not use this product near water, for example, near a bath
tub, wash bowl, kitchen sink, or laundry tub, in a wet
basement, or near a swimming pool.
3. Never push objects of any kind into this product through
cabinet slots as they may touch dangerous voltages.
4.
SAVE THESE INSTRUCTIONS
1
2
3
1) Hook from the top
2) Swing into place
3) Push button to lock
OpenHouse modules
attach from the top
tm
ChannelPlus model H616
Telephone Master Hub (4 lines x 6 phones)
Telephone Master Hub (4 lines x 6 phones)
TelephonesTelephones
From
Telco
From
Telco
RJ31X
Out
Expansion
Ports
Expansion
Ports
R
T
R
T
4
R
T
R
T
3
R
T
R
T
2
R
T
R
T
1
SAFETY INFORMATION:
a) Never install telephone wiring
during a lighting storm.
b) Never install telephone jacks in wet
locations.
c) Never touch uninsulated telephone
wires or terminals unless the
telephone line has been disconnected
at the network interface.
d) Use caution when installing or
modifying telephone lines.
Use self adhesive
sticker provided to
label the output I.D.
Use CAT-3 or CAT-5
wires, 2 lines to 8
telephone wall
3
4
5
6
1
2
3
4
5
6
1
2
ChannelPlus Enclosures, Modules,
Accessories & Wall Plates
ChannelPlus model H628
Data Hub (8 cables, TIA-568A) Category 5 Compliant
OUT
IN
532-230 5MHz to 1000MHz
OUT
IN
OUT
IN
OUT
IN
OUT
IN
SPLITTER
COMBINER
R
TelephonesFrom
Telco
ChannelPlus model H801
Combo Hub (2 lines x 6 phones, 1input x 4 televisions)
R
T
2
R
T
1
ChannelPlus model H616
Telephone Master Hub (4 lines x 6 phones)
Telephones
From
Telco
RJ31X
Out
Expansion
Ports
R
T
4
R
T
3
R
T
2
R
T
1
Starter systems
RF splitters and telephone punch
downs. When it is time to upgrade,
just snap this module out and
replace with one of more of the
more sophisticated units.
Data hubs
Termination blocks for the CAT-5 cables,
Ethernet hubs. Bring the Internet to any
room in the home. Or create a home data
network.
Telephone hubs
Connections for 1-4 phone lines to
every room. Starter hub adds RJ-
31X jack for security system dialer.
Coax panels
Distribute antenna or cable TV to every
room of the house. Some models include
bi-directional amplifiers for interactive cable
systems. Some models include
IR engines.
modulator
inputs and
AV modulators
(for service center)
Create a new TV channel for a front
door camera. Some models feature
Cat-5 input connections.
TM
Compatible
Service center
enclosures
A full line of OpenHouse compatible
enclosures, from simple, inexpensive
mounting plates to high capacity in-wall
cabinets. AC outlets can be mounted
inside the cabinets using a UL listed
accessory.
AV modulators
(for media center)
Create new TV channels for DVD, VCR,
or a satellite receiver. These modulators
sit in the media center. Some offer true
MTS stereo.
®
model 5445 quad digital modulator
pll frequency control
D
C
BA
program
select
Wall plates
Wall plate systems for all rooms. The typical room gets TV
and telephone. The Home office wall plate adds data ports.
The media center wall plate adds satellite feeds.
IR Accessories
Control video devices from any room.
New OpenHouse products are added all the time.
Visit our website to learn more:
www.openhousesystems.com
Wiring a house for OpenHouse
Typical Room
Media Center
Home Office
Good
Better
Best
1 Cat-5
1 RG-6
1 Cat-5
3 RG-6
1 Cat-5
2 RG-6
2 Cat-5
1 RG-6
2 Cat-5
2 RG-6
2 Cat-5
3 RG-6
3 Cat-5
3 RG-6
2 Cat-5
2 RG-6
3 Cat-5
3 RG-6
Good ...
Typical room - phone, TV
Media center - phone, satellite receiver, AV modulators
Home office - phone, TV,
Better …
Typical room - phone, TV, ethernet
Media center - phone, TV, satellite receiver, AV modulators
Home office -
Best …
cable modem
ethernet,
phone, TV, ethernet, cable modem
Typical room - phone, TV, ethernet, satellite receiver
Media center - phone, TV, ethernet, satellite receiver, AV modulators, hi-speed data
Home office - phone, TV, ethernet, satellite receiver, cable modem, hi-speed data
The cables in an OpenHouse run from the various rooms of the house
directly to the service center location.(This is known as ‘home run’
wiring.) Two types of wire are used for communication and
entertainment: Cat-5, 4-UTP (4 nshielded wisted airs) wire handles
data or 1 to 4 telephone lines. RG-6 coax handles television (antenna or
cable), satellite dish, cable modem, or AV modulator signals. (An AV
modulator creates new TV channels for front door camera, DVD player, a
VCR or a satellite receiver.)
We recommend the following pre-wire schemes . Run these wires from
the service center to the rooms indicated.
UTP
Multiplex Technology, Inc., Brea, CA 92821Multiplex Technology, Inc., Brea, CA 92821
600-210 Rev. A600-210 Rev. A
multiplex
technology, inc.
®
*
*
*
3001 Enterprise Street, Brea, CA 92821-6213, U.S.A.
714-996-4100 800-999-5225 FAX 714-996-4900 www.openhousesystems.com
TM
ChannelPlus
Telephone Entry Module
Model H612
Warranty
Multiplex Technology, Inc. warrants this product to be free from defects in materials and workmanship
for a period of one year from the date of purchase or MTI will repair, or at its option, replace the
defective product. To obtain warranty service, call MTI for a return material authorization (RMA)
number and return the product prepaid to Multiplex Technology, Inc., 3001 Enterprise Street, Brea, CA
92821, Attention: Customer Service. Please put the RMA number on the outside of the carton.
Any implied warranty arising from the sale of the product including implied warranties of
merchantability and fitness for purpose are limited to the warranty stated above. MTI shall not be
responsible for losses or damages or expenses, whether direct, consequential or incidental arising
from the use of or the inability to use this product. Some states do not allow limitations on how long the
implied warranty lasts or the exclusion or limitation or incidental or consequential damages, so the
above limitations and exclusions may not apply to you. This warranty gives you specific legal rights,
and you may have other rights which may vary from state to state.
  • Page 1 1
  • Page 2 2

Channel Plus H612 User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI