BEA EYE-TECH User guide

  • Hello! I am an AI chatbot trained to assist you with the BEA EYE-TECH User guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
MASTER
Technology : Active infrared
  •1mastermodule
  •9slavemodules(standardversion)
  •8slavemodules(monitoredversion)
Detectiondistance: 0.7mto2.5m
  (adjustablebylinearmovementswivellingcam)
Moduleinclinationangle: 0°-5°-10°-15°-20°-25°
Diameteroftheinfraredbeamat2m: 0.13m
Detectionmode: Presence(andmovement)
Detectionduration(presence): Infinite
Responsetime: <50ms
Specialinputs: •systeminhibition
  •optional:surveillance
Supplyvoltage
  •relayoutputoption:12to24VAC/DC±10%
  •transistoroutputoption:12to30VDC±10%
Mainsfrequency: 50to60Hz
Powerconsumption
•MasterON: 60mAmaximum
•SlaveON: 40mAmaximum
•MasterOFF: 30mAmaximum
•SlaveOFF: 30mAmaximum
Standardoutput: Switch-overrelay(voltagefreecontact)
•relaycontactratings(maxvoltage): 60VDC/125VAC
•relaycontactratings(maxcurrent): 1A(resistive)
•max.switchingpower: 30W(DC)/60VA(AC)
Optionaloutput: Opencollectortransistor
•max.voltage: 30VDC
•max.current: 100mA(protectionagainstshort-circuits)
Outputholdingtime: 0.1sto4.5s(adjustable)
Adjustments: •detectiondistance(byswivellingcam)
  •holdingtime(bypotentiometer)
  •normal/antimaskingconfiguration(byjumper)
  •darkON/lightONconfiguration(byjumper)
Temperaturerange: –20°Cto+50°C
Immunity: Electromagneticcompatibility(EMC)89/336/EECand92/31/EEC
Dimensions: 340-700-900mm(L)x43.5mm(H)x47.5mm(D)
Mass: •0.330Kg(length340mm,1Master)
  •0.620Kg(length700mm,1Master+1Slave)
  •0.740Kg(length900mm,1Master+2Slaves)
Material: Aluminium,ABSandPlexiglas
Colourofthebox: Naturalaluminium(blackorchromeoptional)
  blackfrontside
Connectionsheath: 0.5m
SAFETYSENSORFORSWINGINGDOORSANDREVOLVINGDOORS
EYE-TECHUSER’SGUIDE
TECHNICAL
CHARACTERISTICS
DESCRIPTION
OF THE SENSOR
Connectionsheath
+wallfixationfastener
Linkcable
Aluminiumsection
Sidecaps
Modulefixationsupports
Frontcover
Receiveroptics
Antimaskingjumper
Linkconnector(OUTPUT)
Transmitteroptics
RedLED
Linkconnector(INPUT)
SLAVE MODULE
OVER VIEW
MASTER MODULE
GreenLED
Receiveroptics
Antimaskingjumper
Holdtimeadjustment
JumperDARKON-LIGHTON
Linkconnector(OUTPUT)
Transmitteroptics
RedLED
Adjustmentscrewfordetectiondistance
Removableterminalblock
TIPS FOR USE
Noobjectsshallbewithin
thedetectionzone.
Preferably,exposuretoheavy
rainmustbeavoided.
•Removethefrontcoverby
oneofthesides.
•Unscrewsidecaps. •Removetheplasticmodule
supportsusingascrewdriver
afterdisconnectingthe
SLAVES.
•RemovetheMASTER’s
removableterminalblock.
OPENING AND
DISASSEMBLY
OF THE SENSOR
DISASSEMBLED
MATERIAL
HOUSING
MASTER
(AND)
SLAVE
FRONTCOVER
CONNECTIONSHEATH
ANTIMASKING
TESTPAPER
WALL
FIXATION
FASTENER
+2SCREWS
2SIDECAPS
2SCREWS
•Thesensorisopen(withoutfrontcover).
•Theanti-maskingfunctionisactivated(see:adjustmentofthe
functions)bothinMASTERandSLAVES.
•Makesurethereisnotargetinfrontofthesensor.
•Placetheholeofthetestpaperinfrontofthereceptionlensof
eachmodule.
•TheredLEDdoesnotlightup,otherwisetheconfigurationmust
notbeusedforthistypeofenvironment.
III. ANTI-MASKING
TEST
FOR MONITORED VERSION ONLY :
•Inputs1and2ofthe
terminalareproperlywired
andsupplied.
•Ifthesurveillanceoption
cannotbeused,movethe
end-of-loopjumperonthe
surveillancecancellation
jumper.
Terminals1and2arethen
unnecessary.
•Theend-of-loopjumperis
mountedonthelastSLAVEor
MASTERmodule,ifthereare
noSLAVES.
MONITORED
VERSION
•Theinhibitioninputisused
tostopthedetectionprocess
whenthedoormustfacea
fixedobstacleattheendof
itsswingangle.
•Adjusttheoperator
«camswitch».Cablethe
inhibitioninputtoinhibitthe
sensorbeforedetectingthe
obstacle.
Placetheconnectionsheathin
thecap’sgroove.
•Fastenthesecondsidecap.
•Screwthewallfixation
fastenerontothefixedbox,
insertingtheconnection
sheathinit.
END OF
INSTALLATION
TROUBLESHOOTING
SYMPTOMS : CORRECTIVE ACTIONS :
Thedoordoesnotopen. a)Checkpowersupply.
TheredLEDdoesnotlightupintheabsenceofatarget. b)Checkrelaycabling(NOorNC).
Thedoordoesnotopen. a)Checkthatthesurveillanceinputisdeactivated.
TheredLEDlightsup. b)Decreasethedetectiondistance.
Thedetectordetectserraticly. a)Makeanotherantimaskingtest.
b)Decreasedetectiondistance.
Youhaveproblemsinsertingthemoduleintothealuminiumsection. Checkthemoduleorientation.
Thedooropenswithouttakingdetectionintoaccount. Checkrelaycabling.
TheredLEDlightsup.
END-OF-LOOP
JUMPER
SURVEILLANCE
CANCELLATION JUMPER
•Reinsertthefrontpart
1.Insertintheupperrail.
2.Tightenthefrontpartprogressively.
WARNING : this sensor is designed exclusively to make automatic doors safer.
BEA SA LIEGE Science Park Allée des Noisetiers, 5 ‑‑ B‑4031Angleur Tel. +32 4 36 65 65 Fax +32 4 361 28 58 inf[email protected] www.bea.be
42.0552-V1 05/07
II. CONFIGURING
THE INHIBITION
INPUT
A
1
2
4,5s
MASTER: SLAVE:
DARK ON LIGHT ON
10mm
Ø4mm
4 5 6 7 8
DARK ON (DO) DARK ON (DO)
LIGHT ON (LO) LIGHT ON (LO)
30cm
< > < >
10mm
1 2 3
INITIAL ADJUSTMENT
NOTACTIVATED
DARK-ON
0.1s
Jumpersupplied
withthemaster
Eachmodule(MASTERandSLAVE)isequippedwithjumpers
allowingconfiguration.
MASTER + SLAVE
Anti-masking
function
The sensor is put in detection
mode when one of the optics
is masked.
DO: the relay is released
on detection
LO : the relay is activated
on detection
Increased holding time.
ACTIVATED NOT ACTIVATED
MASTER
Operating
mode
MASTER
Holding time
potentiometer
FOR CONTROLLED VERSION
End-of-loop jumper to be placed on the last
slave of the link
(or on the MASTER if no SLAVES).
FUNCTION
ADJUSTMENT
AND
CONFIGURATION
0.1s
•Breakthepartofthecap
(hingeside)toallow
passagefortheconnection
sheath.
I. INIITAL STEPS
•Screwthecaponthe
sectionfromthedoorhinge
side.
FIXING
THE PROFILE
ON
THE LEAF
Choosethepositionofmodulesinthehousingsfromtheavailablepositionsdescribedabove.
Recommendedangle:20°
Overviewof
thesensing
fieldsasa
functionof
module
placement
angles.
ORIENTATION
OF THE
MODULES
II. INSTALLATION
ON SWINGING
DOORS AND
REVOLVING
DOORS
III. APPLICATION
TO INCREASE
SAFETY
OF SLIDING
DOORS OR
SPECIAL USES
•Screwthescrews. •Exampleofuseona
slidingdoor.
•Exampleofuseon
swingingdoors.
•Exampleofuseon
revolvingdoors.
•Drilltwoholesintheupper
partofthesection.
•Drilltwoholesintheback
ofthealuminiumsection
andinthedoorleaf.
(Usethegroovetoposition
theholes).
•Screwthefixingscrews.
WARNING :
donotpositionthescrews
inthesameplaceascard
fixingsupport.
Detectiondistance
SENSOR TEST
•Takethecardboardbox
oftheEYE-TECH.
•Adjusttheholdingtime
potentiometeroftheinput
toitsminimumvalue.
•Placetheboxat30cm
fromthefloorandata
distancefromthedoor
determinedbythemodule
inclinationangle.
•Movetheboxupand
downandfromlefttoright
toestimatethedeadzone.
•Usingascrewdriver,rotate
thedistancedetection
adjustmentscrewtoobtain
thedetectionat±30cm
(andviceversa).
•Clockwiserotationby
onenotchincreasesthe
detectiondistanceby
±10cm(andinversely).
•Forcethedoortoopen.
•Ifdetectionisobserved
intheabsenceofan
obstacle,rotatethescrew
counterclockwise.
•Whentheadjustmentis
correct,settheholding
potentiometertothedesired
value(recommended
value:2s).
I. DETECTION
DISTANCE
ADJUSTMENT :
Surveillance input
(Master rel. Ctrl or Master tra. Ctrl.)
End-of-travel inhibitor input
+12 to 18 V DC
+12 to 24 V AC/DC
± 10%
Ground
OPTIONALINPUTS TRANSISTORVERSIONSRELAYVERSIONS
Powersupply:12to24VAC/DC±10% Powersupply:12to30VDC±10%
Powersupply:12to24VAC/DC±10% Powersupply:12to30VDC±10%
•Connectthecablesofthe
operatortotheremovable
terminal.
REMARK :Ifaninductiveloadisconnected(operatorrelay),putaprotectivediode.
CABLING
THE SENSOR
•connectthedifferentmodulestogether.
WARNING:makesurethataninputisconnectedtoanoutput.
REMARK:placethelastSLAVEmodule(orthesingleMASTER)ascloseaspossiblefrom
thesharpedgeofthedoor.
•Drillaholeinthefixedpartofthedoorforthepassage
ofwires.
•Drilltwo4mmholesoneachsideoftheholeforthe
passageofthewires(tofixthewallfixationfastener).
INSERTING
AND
CONNECTING
THE MODULES
PREPARING
THE CONNECTION
CABLE
•Reinsertthemodule(s)andmakesurethattheMASTERis
onthehingeside.
•Passthewirethroughthe
connectionsheath.
•Connecttotheremovable
terminalstripoftheMASTER.
LEFT
DOOR
RIGHT
DOOR
/